Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Charliecloud: Unprivileged containers for user-defined software stacks in HPC

Supercomputing centers are seeing increasing demand for user-defined software stacks (UDSS), instead of or in addition to the stack provided by the center. These UDSS support user needs such as complex dependencies or build requirements, externally required configurations, portability, and consistency. The challenge for centers is to provide these services in a usable manner while minimizing the risks: security, support burden, missing functionality, and performance. We present Charliecloud, which uses the Linux user and mount namespaces to run industry-standard Docker containers with no privileged operations or daemons on center resources. Our simple approach avoids most security risks while maintaining access to the performance and functionality already on offer, doing so in less than 500 lines of code. Charliecloud promises to bring an industry-standard UDSS user workflow to existing, minimally altered HPC resources.

97 MATHEMATICS AND COMPUTING↗

Developing and testing capabilities for simulating cases with heterogeneous land/water surfaces in a novel atmospheric large eddy simulation code

Large eddy simulations (LES) are the primary computational tool used to simulate high Reynolds number three-dimensional turbulent flows. In the context of earth system sciences, particularly atmospheric science, LES are uniquely able to resolve the scales of atmospheric motion that are key for building process-level understanding of boundary layer turbulence, atmosphere-surface interaction, clouds, and cloud-aerosol-chemistry interaction, and are a core limited-area modeling capability. Increasing demands are being placed on LES code bases as growing high performance computing resources allow LES to address a wider range of scientific problems. In addition, LES are emerging as a source of high-quality machine learning training data. These demands necessitate an agile and extensible code base that allows the model to quickly adapt to emergent needs. However, LES have largely relied on legacy Fortran code bases that lack flexibility. A new, Python-based LES capability called Predicting INteractions of Aerosol and Clouds in Large Eddy Simulation (PINACLES) has been developed as part of the Department of Energy’s Earth System Model Development (ESMD) program area’s Enabling Aerosol-cloud interactions at Global convection-permitting scalES (EAGLES) project. PINACLES was developed from the ground up with a philosophy of maximizing scientific throughput, by attempting to optimize for both model throughput and software extensibility. The initial development of PINACLES delivered a state-of-the-art idealized LES capability solving the non-hydrostatic anelastic equations of motion with doubly periodic boundary conditions and idealized homogenous surface boundary conditions. Here we provide a final report on the outcomes of a fiscal year 2021 Seed Laboratory Directed Research Project that extended PINACLES in two key ways. First, PINACLES was coupled to a state-of-the-art land surface model enabling it to simulate spatially inhomogeneous land-atmosphere interactions that are known to control key atmospheric processes. Second, the dynamical core of PINACLES was modified to permit non-periodic boundary conditions. This model enhancement enables simulation of realistic cases with boundary conditions prescribed from atmospheric reanalysis and enables nested simulations conducted on a hierarchy of computational domains with increasing resolution. Together, these extensions to PINACLES make it a formidable modeling capability and expand its potential application to diverse components of DOE’s atmospheric science portfolio.

42 ENGINEERING↗

Geologic Seawater Air Conditioning (GeoSWAC) System: Resource Assessment and Techno-Economic Evaluation in Puerto Rico

Puerto Rico's hot, humid climate drives a high and persistent demand for cooling, straining an aging and fuel-dependent energy grid while increasing peak electricity loads. Much of this challenge stems from inefficient air-conditioning systems operating in buildings without passive cooling design, making cooling both costly and vulnerable to disruption - especially during hurricanes. To address these issues, researchers evaluated a new alternative called Geologic Seawater Air Conditioning (GeoSWAC), which uses inland wells connected to naturally cold, deep seawater. By avoiding long offshore pipelines and energy-intensive refrigeration cycles, GeoSWAC can cut electricity use by 75-90%, reduce environmental impacts, and operate more reliably during power outages. A case study at the University of Puerto Rico's Rio Piedras campus found that GeoSWAC could deliver significantly lower levelized costs of cooling, reduced operational expenses, and improved water conservation compared to the campus's existing chilled-water plant. The system offers key advantages - including access to a constant cold heat sink, low pumping requirements, and enhanced resilience - for coastal regions such as Puerto Rico, the broader Caribbean, and Florida. However, its effectiveness depends heavily on site-specific geological conditions, such as subsurface connectivity and aquifer characteristics, which require detailed investigation. Future research should refine hydrogeological models, conduct performance and economic analyses, and address regulatory and permitting frameworks to support broader adoption of this promising technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The CMIP6 Data Request (DREQ, version 01.00.31)

The data request of the Coupled Model Intercomparison Project Phase 6 (CMIP6) defines all the quantities from CMIP6 simulations that should be archived. This includes both quantities of general interest needed from most of the CMIP6-endorsed model intercomparison projects (MIPs) and quantities that are more specialized and only of interest to a single endorsed MIP.The complexity of the data request has increased from the early days of model intercomparisons, as has the data volume.In contrast with CMIP5, CMIP6 requires distinct sets of highly tailored variables to be saved from each of the more than 200 experiments.This places new demands on the data request information base and leads to a new requirement for development of software that facilitates automated interrogation of the request and retrieval of its technical specifications.The building blocks and structure of the CMIP6 Data Request (DREQ), which have been constructed to meet these challenges, are described in this paper.

54 ENVIRONMENTAL SCIENCES↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources: Preprint

Integration of a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problem requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs) including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperformed other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Challenges of Maintaining Institutional Controls: Maintenance of an Alternate Water Supply- A Case Study - 19583

The US Department of Energy (DOE) cofunded an alternate water-supply system (AWSS) with the Indian Health Service that was installed in the vicinity of the former uranium mill site near Riverton, Wyoming, as one of the institutional controls (ICs) at the site. The AWSS was constructed in 1998 to supply drinking water to residents within the IC boundary in lieu of drinking untreated groundwater that could potentially be impacted by the contaminated shallow aquifer. The AWSS derives water from three source wells that pump groundwater from the sandstones of the Wind River Formation to a 3.8 x 106 liter (1,000,000 gallon) storage tank. Water from the storage tank is distributed throughout the AWSS service area by approximately 18 kilometers (11 miles) of PVC pipeline. The AWSS currently serves 103 residential customers and 1 commercial customer. DOE and the Northern Arapaho tribe (owner of the AWSS) have partnered over the years to address numerous challenges with the AWSS that included engineering assessments, scientific investigations, sampling support, a hydrant flushing program, and funding. Challenges with the AWSS have included the following: (1) Transmission pipe installed during initial construction did not have a pressure rating high enough to account for system pressure surges. (2) AWSS appurtenances were initially installed without accounting for the effects of corrosive soils on metal components. (3) Natural radium from the Wind River Formation groundwater builds up in the AWSS transmission pipes to levels above the primary drinking water standard because of the lack of a flushing program, dead-end lines, and low system demand. A 2-year study showed that a unidirectional hydrant-flushing program will control the radium buildup. (4) Aging system components including hydrants, valves, and pumps are nearing their effective lifespan and are in need of replacement. (5) With the addition of large commercial customers, demand on the system has increased since the initial installation of the system, and future growth in the area will continue to increase demand. (6) Additional connections and integration of the AWSS with an areawide water system in the near future will require changes to the current flushing plan and add additional complexity regarding areas of responsibility. (7) A well-organized financial and administrative infrastructure is not in place, and additional revenue is needed to operate, maintain, and improve the AWSS. To be a viable IC, the AWSS will require management, maintenance, and upgrades to provide safe drinking water until groundwater meets drinking water standards. Responsibilities and funding for maintaining the AWSS as a viable IC are the focus of current discussions, and decisions regarding responsibilities and funding will be formalized in future cooperative agreements and memoranda of understanding with the owners. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Exploration of Impacts of Wide-Scale Implementation of Net Zero-Energy Homes on the Western Grid

Pacific Northwest National Laboratory conducted a study on the impact of wide-scale implementation of net zero-energy homes (ZEHs) in the western grid. Although minimized via utilization of advanced building technologies, ZEHs still consume energy that must be balanced on an annual basis via self-generation of electricity, which is commonly assumed to be from rooftop photovoltaics (PV). This results in a ZEH having a significantly different electricity demand profile than a conventional home. Widespread implementation of ZEHs will cause absolute demand levels to fall compared to continued use of more conventional facilities; however, the shape of the demand profile will also change significantly. Demand profile changes will lead to changes in the hourly value of electric generation. With significant penetration of ZEHs, it can be expected that ZEHs will face time-of-day rates or real-time pricing that reflect the value of generation and use. This will impact the economics of ZEHs and the optimal design of PV systems for subsequent ZEHs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel PCM Integration with Electrical Heat Pump for Demand Response

In this paper, we examine the potential for using phase change material (PCM) as a thermal storage medium for improving the efficiency as well as enabling grid-responsive control of heat pump (HP) systems. Previous research in PCM integration in buildings has primarily been focused on integration with building envelopes. An objective of our research is to design a novel and practical PCM integration with existing HP systems. High-fidelity models for building, HP and PCM are developed to facilitate the model-based predictive control (MPC) design. To optimize the operation of HP and PCM, we introduce an optimization problem considering various constraints for both comfort and hardware constraints. We include experimental results in which a house fleet are optimized to minimize their power consumption or electricity cost. We numerically demonstrate the designs potential for reducing power consumption or electricity cost by 13% or 19%, respectively.

Dong, Jin↗

CRADA Number NFE-19-07846 with Grid Fruit, LLC (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07846 between Oak Ridge National Laboratory (ORNL) and Grid Fruit, LLC (Grid Fruit) focused on simulating, monitoring, and adjusting controls of commercial refrigerator and freezer systems to provide load flexibility and demand response services from these machines. Viewing these medium and low-temp coolers as thermal masses, the volumes of chilled air in these coolers make them time-shiftable loads ripe for deployment at optimal times. Grid Fruit is a startup company developing methods to schedule the chilling cycles (e.g., in “build load” and “shed load” grid events) to provide energy efficiency, peak shifting, and other benefits both to the grid and the broader environment. These benefits can be magnified by coordinating chillers with HVAC, lights, computers, and other loads. Grid Fruit completed simulations and then selected and ordered controls hardware to prove the technology were successful, but the diversity of chiller models in the field without digital controls, as well as limited market demand at present, make further exploration necessary before commercialization.

42 ENGINEERING↗

Maturing Rational Design Methodologies and Industry Consensus Engineering Standards: Critical Fastened Joints - Solar PV Industry

Critical structural joints can be seen throughout a solar array and are called upon to secure modules and keep racking assembled and able to resist large demands from winds and snow loads. In the relatively new and fast-growing solar PV industry, the important role these hardware assemblies (e.g. clips, clamps, bolts, nuts, washers) play is not well understood by product designers. Failures with critical structural joints are surprisingly common and point to the need for maturing the engineering and assembly of these joints. The wide variety of design concepts (Figure 2&2) demonstrate interesting and innovative ideas but are lacking the basics of fastener engineering seen in matured industries (e.g. transportation, buildings). Complicating the maturing process for critical structural joints is that they are one component in rack supporting structures that exhibits a systems behavior; each component will affect the other and play a key role in maintaining structural integrity. When wind loads the surface of a module, the underlying racking members deflect and twist which in turn imparts forces back into the joints and into the mounted modules. Often, these supporting rack structures exhibit high deflections and low natural frequencies which amplify the demands placed into the joints even in moderate winds. Current engineering practices and associated structural conventions view solar racking support structures as they would a high mass building that exhibit more static behaviors in wind events. Solar structures are unique from high mass buildings and require the development of solar specific industry engineering consensus standards.

14 SOLAR ENERGY↗

Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates

Thermal losses and gains from ductwork installed in unconditioned spaces—such as attics, crawl spaces, and garages—can contribute significantly to the overall heating and cooling loads of single-family residential buildings, with estimated duct losses ranging from 10%–45 %. The impact is particularly severe in hot climates where air conditioning dominates and extensive duct systems are typically located in hot attics. The duct system inefficiencies are greatest at peak demand conditions when the attic is hottest and run times are the highest. The thermal losses and gains at the three single-story houses in Florida monitored in this study accounted for 15%–35% of the annual pre-retrofit heating and cooling energy use and 6%–25% of the total pre-retrofit annual utility bill. Even though a number of existing methods can effectively move ducts into the conditioned space, they are not currently being widely implemented. Physically locating the ducts within the conditioned space is most often applicable only to new construction projects and requires planning during design. Attics can be insulated at the roof deck with closed-cell polyurethane foam (ccSPF) to reduce duct losses and infiltration rates, but this method has high up-front costs and the potential to increase loads on the building enclosure. In hot-dry climates, attic duct systems can be buried under loose-fill insulation at a significantly lower cost to reduce thermal loads. In hot-humid climates, however, condensation on the duct jacket can occur when the humidity in the attic is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Utilities (TPU) and the Bonneville Power Administration. The Woods is a Habitat for Humanity (HFH) community of homes certified by ENERGY STAR Homes Northwest (ESHNW); the community is in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report and includes significant billing analysis and cost-effectiveness research from a collaborative and ongoing DHP research effort for TPU and the Bonneville Power Administration. This final BA report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing. The research goal of the U.S. Department of Energy's BA research team Building America Partnership for Improved Residential Construction was to compare a ductless heat pump (DHP) hybrid system (DHP in common area/electric resistance [ER] in bedrooms) to an all-electric zonal ER system in high-performance single-family affordable housing. This effort included assessing the costs and benefits of a DHP/ER hybrid system located in the main living area to offset the primary heating demand of zonal ER heaters in the bedroom zones and comparing these findings to data from of new affordable single-family housing in Washington State. This report includes: (1) Measured indoor and outdoor temperatures and relative humidity (RH) in the homes. (2) Field testing results of heating, ventilating, and air-conditioning equipment; ventilation system airflows; building envelope tightness; lighting, appliance, and other input data required for preliminary Building Energy Optimization (BEopt) modeling; and ENERGY STAR field verification (3) BEopt modeling results compared to measured energy use. (4) A comparison of the space heat energy consumption of a DHP/ER hybrid heating system and a traditional zonal ER heating system installed in the same home. This comparison is made by implementing a series of weekly "flip-flop tests" (referred to here as "switchback" tests per TPU) to compare space heating, temperature, and RH in zonal ER heating mode with a DHP/ER mode as discussed in the Building America Test Plan (Lubliner 2010a). (5) Cost data from HFH and other sources related to building efficiency measures focusing on the DHP/ER hybrid heating system. (6) An evaluation of the thermal performance and cost benefit of DHP/ER hybrid heating systems in these high-performance homes employing life cycle cost analysis for energy code policy and monthly cash flow analysis of HFH homeowners. (7) Post-monitoring occupant survey results. The report also provides the following stakeholder findings and recommendations: (1) DHP single-head systems at The Woods are cost-effective to new homebuyers of these high-performance all-electric homes. (2) Stakeholder education is needed on design, inspection, and commissioning; documentation is needed for heat recovery ventilation (HRV) and from ENERGY STAR builders, verifiers, and inspectors to help ensure that the houses meet the goal of "build tight, ventilate right." (3) A code gap in inspection and enforcement was identified that should be addressed by: (3a) Improving the fire marshal's approach to sprinkler attic piping freeze protection; (3b) Improving the maintenance of ceiling insulation continuity; and (3c) Educating the local building inspector on attic insulation inspection concerns that allow for maximizing design improveme...

affordable housing↗

Supervisory Control of Loads and Energy Storage in Next-Generation Zero Energy Buildings

A zero energy building (ZEB)—also known as a net zero energy or zero net energy building—is a building that exports as much renewable energy as the total energy it imports from other sources on an annual basis (DOE 2015). Large-scale and commercially viable ZEBs are now in the marketplace, and they are expected to become a larger share of the commercial building footprint as government and private sector policies continue to promote the development of buildings that produce more on-site energy than they use. However, the load profiles of ZEBs are currently perceived by electric utilities to be unfavorable and unpredictable. As shown in Figure ES-1, ZEB load profiles can have abrupt changes in magnitude, at times switching rapidly between exporting and importing electricity. This is a challenge for utilities, which are responsible for constantly balancing electricity supply and demand across the grid. Addressing these concerns will require new strategies and tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

India Energy Outlook: End Use Demand in India to 2020

Integrated economic models have been used to project both baseline and mitigation greenhouse gas emissions scenarios at the country and the global level. Results of these scenarios are typically presented at the sectoral level such as industry, transport, and buildings without further disaggregation. Recently, a keen interest has emerged on constructing bottom up scenarios where technical energy saving potentials can be displayed in detail (IEA, 2006b; IPCC, 2007; McKinsey, 2007). Analysts interested in particular technologies and policies, require detailed information to understand specific mitigation options in relation to business-as-usual trends. However, the limit of information available for developing countries often poses a problem. In this report, we have focus on analyzing energy use in India in greater detail. Results shown for the residential and transport sectors are taken from a previous report (de la Rue du Can, 2008). A complete picture of energy use with disaggregated levels is drawn to understand how energy is used in India and to offer the possibility to put in perspective the different sources of end use energy consumption. For each sector, drivers of energy and technology are indentified. Trends are then analyzed and used to project future growth. Results of this report provide valuable inputs to the elaboration of realistic energy efficiency scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cradle-to-gate life cycle assessment of advanced composite panels incorporating CO 2 -derived multi-walled carbon nanotubes and hemp fiber for sustainable building applications

Advanced composite panels represent a promising pathway to reducing carbon emissions in the construction industry, yet comprehensive environmental impact assessments remain limited. Here, in this study, we conduct a life cycle assessment (LCA) to evaluate the environmental impacts of innovative composite panels produced from multi-walled carbon nanotubes (MWCNTs), hemp fiber (HF), recycled carbon fiber (rCF), and recycled polypropylene (PP), exploring their potential as baseline structural equivalents to conventional gypsum board. MWCNTs and HF play a critical role in sequestering carbon during raw material production, while the recycling processes for CF and PP generally require less energy compared to virgin material production. The LCA evaluates environmental performance using the TRACI 2.1 method, covering global warming potential (GWP), ozone depletion, smog formation, acidification, eutrophication, carcinogenic and non-carcinogenic effects, respiratory impacts, ecotoxicity, and fossil fuel depletion. Compositional variations—resin type (virgin vs. recycled), rCF content (9–29 wt%), and HF content (10–30 wt%)—are introduced for sensitivity and hotspot analyses. Results demonstrate that, when compared on the basis of preliminary structural equivalence, increasing recycled PP, rCF, and HF content can significantly reduce global warming potential compared to gypsum board. Beyond carbon reduction, the composite panels show trade-offs across other environmental categories. With the growing demand for composite materials in interior panels, ceiling systems, and exterior claddings, these findings highlight the environmental benefits and potential trade-offs of the proposed composites, establishing a foundational framework to support their continued development toward full building-system integration.

Advanced composite manufacturing↗

New York Solar Smart DG Hub-Resilient Solar Project: Economic and Resiliency Impact of PV and Storage on New York Critical Infrastructure

Resilient PV, which is solar paired with storage ('solar-plus-storage'), provides value both during normal grid operation and power outages as opposed to traditional solar PV, which functions only when the electric grid is operating. During normal grid operations, resilient PV systems help host sites generate revenue and/or reduce electricity bill charges. During grid outages, resilient PV provides critical emergency power that can help people in need and ease demand on emergency fuel supplies. The combination of grid interruptions during recent storms, the proliferation of solar PV, and the growing deployment of battery storage technologies has generated significant interest in using these assets for both economic and resiliency benefits. This report analyzes the technical and economic viability for resilient PV on three critical infrastructure sites in New York City (NYC): a school that is part of a coastal storm shelter system, a fire station, and a NYCHA senior center that serves as a cooling center during heat emergencies. This analysis differs from previous solar-plus-storage studies by placing a monetary value on resiliency and thus, in essence, modeling a new revenue stream for the avoided cost of a power outage. Analysis results show that resilient PV is economically viable for NYC's critical infrastructure and that it may be similarly beneficial to other commercial buildings across the city. This report will help city building owners, managers, and policymakers better understand the economic and resiliency benefits of resilient PV. As NYC fortifies its building stock against future storms of increasing severity, resilient PV can play an important role in disaster response and recovery while also supporting city greenhouse gas emission reduction targets and relieving stress to the electric grid from growing power demands.

14 SOLAR ENERGY↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗