Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Quartz Crystal Microbalance (QCM) monitor of contamination for LES-8/9

A Quartz Crystal Microbalance (QCM) was used to monitor condensable contamination during the launching of two Lincoln Laboratory Experimental Satellites--LES-8 and LES-9. The QCM was installed on the dispenser truss and measured contamination by means of a frequency shift of a quartz crystal oscillator. By using a special crystal cut and a second reference quartz crystal, the sensor had extreme sensitivity and remarkable temperature independence. A 1-Hz frequency shift, which corresponds to 3.5 x 10 to the -9th power g/sq cm was resolved by the flight instrumentation.

Lynch, J. T.↗

Filtration effects on ball bearing life and condition in a contaminated lubricant

Ball bearings were fatigue tested with a noncontaminated MIL-L-23699 lubricant and with a contaminated MIL-L-23699 lubricant under four levels of filtration. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns. Aircraft turbine engine contaminants were injected into the filter's supply line at a constant rate of 125 milligrams per bearing hour. Bearing life and running track condition generally improved with finer filtration. The experimental lives of 3- and 30-micron filter bearings were statistically equivalent, approaching those obtained with the noncontaminated lubricant bearings. Compared to these bearings, the lives of the 49-micron bearings were statistically lower. The 105-micron bearings experienced gross wear. The degree of surface distress, weight loss, and probable failure mode were dependent on filtration level, with finer filtration being clearly beneficial.

Loewenthal, S. H.↗

Contamination effects from materials selected for spacecraft instruments

Measurements of the Total Mass Loss (TML) and the Collected Volatile Condensable Materials (CVCM) are used as a guide for selecting those materials being low in outgassing. A contamination modelling method utilizing the data and also the rate at which a material outgasses in a system with a known conductance has been developed and has been applied to the problem encountered with the Very High Resolution Radiometer (VHRR). Recently, the contamination model has been applied to the problem with the 5th band of the Multi-Spectral Scanner on the Landsat-C satellite. In the MSS design, the volumes involved and their respective conductance in a molecular flow field demonstrated that the water vapor adsorbed and absorbed by an epoxy paint was being pumped off and re-ad(b)sorbed, with a resultant very slow loss of water during each degassing temperature cycle of the instrument's cooler. Recommendations for designing improved coolers are presented.

Heslin, T. M.↗

Detecting contaminants by ultraviolet photography

Relatively high ultraviolet absorptivity of most organics as compared to metal is suggested as basis for detecting traces of contamination. By photographing metal surface in ultraviolet light, contaminants that might otherwise interfere with adhesion of surface coatings, or with welding or brazing, could be detected and removed. Real time monitoring of cleaning process is also possible if ultraviolet sensitive television camera is used instead of photographic film.

Neiswander, D. W.↗

Speedy Acquisition of Surface-Contamination Samples

Biological contamination of large-area surfaces can be determined quickly, inexpensively, and accurately with the aid of a polyester bonded cloth. Cloth is highly effective in removing microbes from a surface and releasing them for biological assay. In releasing contaminants, polyester bonded cloth was found to be superior to other commercial cleanroom cloths, including spun-bound polyamid cloths and cellulose cloths.

Puleo, J. R.↗

Detecting Contamination With Photoelectron Emission

Photoelectron emission from aluminum or epoxy-painted aluminum can be used to reveal presence and concentration of surface contaminants. Emission can be used to locate those parts of surface that are excessively contaminated and to which coatings cannot be reliably bonded. Cleaning can then be done on areas that most need it. Probe moves at rate of typically 1 ft/s (30 cm/s), speed slow enough to ensure sensitivity but fast enough to keep scanning time within reasonable limit.

Smith, T.↗

Experiments on the effect of ultraviolet on contamination in vacuum systems

A series of experiments designed to investigate the effect of irradiating a portion of a vacuum system with ultraviolet (UV) light are discussed. Data obtained with the quartz crystal microbalance show that, under ultraviolet irradiation, clean and contaminated mean different things than in situations that do not involve irradiation. The history of the chamber appears to be of paramount importance, not the pumping mechanism. UV irradiation check for contamination is recommended in critical experiments.

Kruger, R.↗

Contamination control of the Infrared Astronomical Satellite

The Infrared Astronomical Satellite, to be launched in August 1981, will perform an all-sky survey in the 8-120 micron wavelength region. High sensitivity to thermal radiation and the low operating temperature of optics and thermal control surfaces make the IRAS telescope extremely vulnerable to contamination. Four special topics of importance are discussed in this paper: (1) deposition of atmospheric gases; (2) sighting of particles released from the satellite; (3) functions of a deployable aperture cover; and (4) degradation of a radiatively cooled sunshade from spacecraft outgassing. These topics demonstrate how mission strategy, ground cleaning and handling, and hardware design are used to avoid contamination which would degrade telescope performance.

Andreozzi, L. C.↗

National Oceanic and Atmospheric Administration /NOAA/ contamination monitoring instrumentation

The JPL has designed and built a plume contamination monitoring package to be installed on a NOAA environmental services satellite. The package is designed to monitor any condensible contamination that occurs during the ignition and burn of a TE-M-364-15 apogee kick motor. The instrumentation and system interface are described, and attention is given to preflight analysis and test.

Maag, C. R.↗

Particle contamination from Martin Optical Black

The design of the barrel baffle of the Infrared Astronomical Satellite (IRAS) Optical Subsystem to minimize production of particulate contamination is described. The configuration of the 50-inch long, 28.5-inch diameter baffle required pop-rivet assembly after coating with Martin Optical Black for stray light suppression. An experiment to determine the contamination produced at assembly led to the modification of the baffle construction to preclude such damage to the coated surfaces.

Young, P. J.↗

Flight evidence of spacecraft surface contamination rate enhancement by spacecraft charging obtained with a quartz crystal microbalance

The significance of the fraction of the mass outgassed by a negatively charged space vehicle which is ionized within the vehicle plasma sheath and electrostatically reattracted to the space vehicle was determined. The ML-12 retarding potential analyzer/temperature controlled quartz crystal microbalances (RPA/TQCMs) distinguishes between charged and neutral molecules and investigates contamination mass transport mechanism. Two long term, quick look flight data sets indicate that on the average a significant fraction of mass arriving at one RPA/TQCM is ionized. It is assumed that vehicle frame charging during these periods was approximately uniformly distributed in degree and frequency. It is shown that electrostatic reattraction of ionized molecules is an important contamination mechanism at and near geosynchronous altitudes.

Clark, D. M.↗

Dye Indicators for Acidic or Basic Surface Contamination

Application of pH-sensitive dye solution serves as test for acidic or basic contamination of critical bonding surface. Aqueous solution of 0.1 percent Direct Red No. 28 capable of indicating acid activating solution down to 10 parts per million on hardware and tooling. Dye did not cause detectable contamination of surface.

Lakin, A.↗

STS-2, -3, -4 Induced Environment Contamination Monitor (ICEM)

The second, third, and fourth space transportation system missions are described including the location of the IECM in the payload bay and the shuttle coordinate systems used. Measurement results from the three flights are given for each instrument with comparisons to original goals for preflight environment and induced environment contamination. These results include very low levels of molecular mass accumulation rates, absence of molecular films on optical samples, outgassing species above 50 amu undetectable generally low levels of on-orbit particulates, and decay rates for early mission water dump particulates. Results of exposure of several optical materials and coatings to atomic oxygen are also presented. From these results, it is concluded that the space shuttle met the established induced environment contamination goals.

Miller, E. R.↗

Results from a 'small box' realtime molecular contamination monitor on STS-3

On the basis of early estimates of the Shuttle induced environment, Scialdone (1979) concluded that in the vicinity of the cargo, the cargo would have the largest influence on the environment. As a contamination control device, realtime monitors can indicate safe operational periods for sensitive attached payloads. It was, therefore, decided to develop the OSS-1/Contamination Monitor Package (CMP) experiment which was seen as a forerunner of an operational monitor. A description of the CMP is provided, taking into account four actively temperature controlled quartz crystal microbalances (TQCM). The TQCM temperatures could be varied from -60 C to +80 C. The sensor consisted of a matched pair of quartz crystals. The crystals were designated as a sensor and reference crystal. Results obtained during the STS-3 mission are discussed. These results show the feasibility and advantages of a small real-time contamination monitor.

Triolo, J.↗

Preparation and cleanliness verifications of a space simulation chamber for contamination sensitive test specimens

Contamination sensitive optical devices were to be evaluated under thermal vacuum conditions. Test specifications called for an extremely clean chamber environment, ambient temperature chamber walls, and optical surface temperatures at approximately - 30 C. Chamber preparation included the replacement of diffusion pumps with cryopumps and the cleaning of the chamber walls to reduce contamination levels. Chamber cleaning using vacuum bake was tried and abandoned as time consuming and ineffective. Chemical cleaning and cleanliness verification methods were developed. Gas chromatograph analysis techniques were used extensively throughout the cleaning process to verify cleanliness levels prior to evacuating the chamber. A chamber cleanliness verification test using a thermoelectric quartz crystal microbalance and witness samples was performed to demonstrate that an appropriate cleanliness level was achieved.

Koch, W. R.↗

Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

Condon, E. P.↗

Internal contamination issues

Issues concerning contaminated spacecraft atmospheres are identified. Contaminants found in the space shuttle orbiter atmospheric samples are listed. Crew physiological reactions are noted.

Rockoff, L. A.↗

Ambient air contamination: Characterization and detection techniques

Techniques to characterize and detect sources of ambient air contamination are described. Chemical techniques to identify indoor contaminants are outlined, they include gas chromatography, or colorimetric detection. Organics generated from indoor materials at ambient conditions and upon combustion are characterized. Piezoelectric quartz crystals are used as precision frequency determining elements in electronic oscillators.

Nulton, C. P.↗