Voyager high gain antenna calibration and pointing

A mathematical description of the data reduction technique used in analyzing Voyager calibration data is presented. To achieve the required telecommunication link performance, highly accurate pointing of the Voyager high gain antenna boresight relative to earth is necessary. To provide the optimum pointing, in-flight calibrations of the high gain antenna pointing mechanism are regularly made, and the design of the calibration and the antenna error models is delineated. It is shown that due to the use of wide angle sun sensors for celestial attitude control, the Voyager antenna error model differs from those of previous missions. Results of the in-flight calibrations and their implementation in improving the antenna pointing are also presented.

Jahanshahi, M. H.↗

Fast calibration of gas flowmeters

Digital unit automates calibration sequence using calculator IC and programmable read-only memory to solve calibration equations. Infrared sensors start and stop calibration sequence. Instrument calibrates mass flowmeters or rotameters where flow measurement is based on mass or volume. This automatic control reduces operator time by 80 percent. Solid-state components are very reliable, and digital character allows system accuracy to be determined primarily by accuracy of transducers.

Lisle, R. V.↗

Low-speed airspeed calibration data for a single-engine research-support aircraft

A standard service airspeed system on a single engine research support airplane was calibrated by the trailing anemometer method. The effects of flaps, power, sideslip, and lag were evaluated. The factory supplied airspeed calibrations were not sufficiently accurate for high accuracy flight research applications. The trailing anemometer airspeed calibration was conducted to provide the capability to use the research support airplane to perform pace aircraft airspeed calibrations.

Holmes, B. J.↗

Calibration validation for the GEOS-3 altimeter

The absolute bias calibration for the GEOS-3 intensive mode altimeter was measured using two satellite passes whose groundtracks were within 1 km of the Bermuda laser station. The Bermuda laser tracked on the two passes, and was supported by two other NASA lasers on one pass and by the NASA Spacecraft Tracking and Data Network on the other pass. For each pass, the altimeter data around Bermuda was smoothed and extrapolated to the point closest to overhead at the laser site. After correcting for tide heights and sea state effects, the two passes give calibration biases which are in agreement to within 26 cm and have a weighted mean of -5.69 + or - 0.16m for correcting altimeter measurements to the center-of-mass of the spacecraft (i.e., including the antenna tracking point correction). It was found impossible to reconcile the two calibration passes, as well as a set of altimeter crossovers in the middle of the GEOS-3 calibration area, without allowing for a data time tag error. On the bias of a selected set of four crossovers, and an assessment of probable sources of timing error, it was concluded that one interpulse period (10.24 msec) should be added to the data time tags.

Martin, C. F.↗

Calibration validation for the GEOS 3 altimeter

An absolute calibration of the altitude data is needed for some applications of the large quantity of altimeter data taken by the GEOS 3 intensive mode altimeter. The considered calibration technique is based on the use of a gravimetric geoid model and satellite passes which are nearly overhead at island laser tracking sites. Near overhead passes of GEOS 3 were achieved at Bermuda. Two of these passes were tracked by the Bermuda laser. The reported investigation has the objective to obtain a best estimate of the GEOS 3 altimeter calibration bias, using the two available passes and reconciling differences between them. Assuming that orbits with accurate altitudes over Bermuda are obtained, discrepancies between the two passes could be due to incorrect time tagging of the altimeter data. To assist in the resolution of the timing question, additional GEOS 3 passes through the calibration area were selected. On the basis of the obtained results, it is recommended to add 10.24 ms to GEOS 3 altimeter time tags before using the data.

Martin, C. F.↗

Simultaneous in-flight calibrations of the Galileo science platform and attitude control subsystems

This paper presents a design metholodology and simulation study results for a combined star scanner-gyro-scan platform in-flight calibration for the dual spin Galileo spacecraft. The design process involves three separate parts: the construction of an error model, development of the calibration model, and the selection of the appropriate estimation technique. The major innovative contribution lies in the development of the first two parts which are unique to the Galileo design. A unified procedure has been developed to allow simultaneous calibration of the three subsystems. However, provisions are also made in the software to calibrate each subsystem separately when the necessary a priori information is available.

Lai, J. Y.↗

Description and calibration of the Langley unitary plan wind tunnel

The two test sections of the Langley Unitary Plan Wind Tunnel were calibrated over the operating Mach number range from 1.47 to 4.63. The results of the calibration are presented along with a a description of the facility and its operational capability. The calibrations include Mach number and flow angularity distributions in both test sections at selected Mach numbers and tunnel stagnation pressures. Calibration data are also presented on turbulence, test-section boundary layer characteristics, moisture effects, blockage, and stagnation-temperature distributions. The facility is described in detail including dimensions and capacities where appropriate, and example of special test capabilities are presented. The operating parameters are fully defined and the power consumption characteristics are discussed.

Jackson, C. M., Jr.↗

Documentation for the machine-readable version of the Absolute Calibration of Stellar Spectrophotometry

The machine-readable data file of The Absolute Calibration of Stellar Spectrophotometry as distributed by the Astronomical Data Center is described. The data file contains the absolute fluxes for 16 stars published in Tables 1 and 2 of Johnson (1980). The absolute calibrations were accomplished by combining the 13-color photometry calibrations of Johnson and Mitchell (1975) with spectra obtained with a Michelson spectrophotometer and covering the wavelength range 4000 to 10300 A (Johnson 1977). The agreement between this absolute calibration and another recent one based upon data for a Lyr and 109 Vir by Tug, White and Lockwood (1977) is shown by Johnson (1980) to be quite good.

Warren, W. H., Jr.↗

A calibration line list for 807-1167 cm -1 from high resolution Fourier spectroscopy of the 14NH3 nu sub 2 band

A calibration list of 295 lines observed over the 800 to 1170 cm to the -1 power region is presented. This list is intended for use as a calibration reference for calibrating diode laser spectra. The transition frequencies were calibrated against the well established laser frequencies of CO2. The estimated uncertainty in the corrected frequencies is + or - 1x.0001 cm to the -1 power.

Hillman, J. J.↗

A report from the AVS Standards Committee - Comparison of ion gauge calibrations by several standards laboratories

Calibrations by four U.S. laboratories of four hot-cathode ion gauges, in the range 0.07-13 mPa, showed systematic differences among laboratories that were much larger than the expected error of any one calibration. They also suggested that any of the four gauges tested, if properly packaged and shipped, was able to serve as a transfer standard with probable error of 2%. A second comparison was made of the calibrations by two U.S. laboratories of some other gauges that had also been calibrated by the National Physical Laboratory, England. Results did not permit conclusive determination of whether differences were due to the laboratories or to changes in the gauges.

Warshawsky, I.↗

The use of thematic mapper simulator calibration data for assessment of data quality

In flight calibration data collected from the thematic mapper simulator (TMS) were used to assess the quality of Earth scan data. The following results are indicated: (1) based on limited samples, individual TMS channels have noise which varies from channel to channel, but remains constant within a channel; (2) short term variations of more than 5% in the average values of calibration source responses indicate problems; and (3) absolute radiometric calibration is unlikely to be meaningful in a temporal sense due to single point calibration methods used.

Forman, M. L.↗

Phase Calibration for the Block 1 VLBI System

Very Long Baseline Interferometry (VLBI) in the DSN provides support for spacecraft navigation, Earth orientation measurements, and synchronization of network time and frequency standards. An improved method for calibrating instrumental phase shifts has recently been implemented as a computer program in the Block 1 system. The new calibration program, called PRECAL, performs calibrations over intervals as small as 0.4 seconds and greatly reduces the amount of computer processing required to perform phase calibration.

Roth, M. G.↗

Faint Object Spectrograph (FOS) calibration

The Faint Object Spectrograph (FOS) designed for use with The Space Telescope (ST), is currently preparing for instrument assembly, integration, alignment, and calibration. Nearly all optical and detector elements have been completed and calibrated, and selection of flight detectors and all but a few optical elements has been made. Calibration results for the flight detectors and optics are presented, and plans for forthcoming system calibration are briefly described.

Harms, R. J.↗

A technique for dynamically calibrating pressure transducers at cryogenic temperatures

A technique was developed for the calibration of dynamic pressure transducers at cryogenic temperatures. The calibration system utilizes an 8.9 Newton peak thrust shaker which oscillates a helium-filled bellows to generate a sinusoidal dynamic pressure to calibrate transducers immersed in a cryogenic environment. The system has a dynamic pressure measurement uncertainty of approximately 11% and is capable of producing peak-to-peak dynamic pressure amplitudes of 1.4 kPa over a frequency range of 40 to 100 hertz and a temperature range of 100 to 300 K. It provides an unprecedented capability of both static and dynamic calibration of pressure transducers from ambient to cryogenic temperature.

Gibbens, B. V.↗

Recent modifications and calibration of the Langley low-turbulence pressure tunnel

Modifications to the Langley Low-Turbulence Pressure Tunnel are presented and a calibration of the mean flow parameters in the test section is provided. Also included are the operational capability of the tunnel and typical test results for both single-element and multi-element airfoils. Modifications to the facility consisted of the following: replacement of the original cooling coils and antiturbulence screens and addition of a tunnel-shell heating system, a two dimensional model-support and force-balance system, a sidewall boundary layer control system, a remote-controlled survey apparatus, and a new data acquisition system. A calibration of the mean flow parameters in the test section was conducted over the complete operational range of the tunnel. The calibration included dynamic-pressure measurements, Mach number distributions, flow-angularity measurements, boundary-layer characteristics, and total-pressure profiles. In addition, test-section turbulence measurements made after the tunnel modifications have been included with these calibration data to show a comparison of existing turbulence levels with data obtained for the facility in 1941 with the original screen installation.

Mcghee, R. J.↗

Aerosol backscatter lidar calibration and data interpretation

A treatment of the various factors involved in lidar data acquisition and analysis is presented. This treatment highlights sources of fundamental, systematic, modeling, and calibration errors that may affect the accurate interpretation and calibration of lidar aerosol backscatter data. The discussion primarily pertains to ground based, pulsed CO2 lidars that probe the troposphere and are calibrated using large, hard calibration targets. However, a large part of the analysis is relevant to other types of lidar systems such as lidars operating at other wavelengths; continuous wave (CW) lidars; lidars operating in other regions of the atmosphere; lidars measuring nonaerosol elastic or inelastic backscatter; airborne or Earth-orbiting lidar platforms; and lidars employing combinations of the above characteristics.

Kavaya, M. J.↗

Pre-launch Absolute Radiometric Calibration of LANDSAT-4 Protoflight Thematic Mapper

From both scientific and applications perspectives, the usefulness of TM digital imagery is significantly determined by its radiometric characteristics. This includes both the accuracy to which the dynamic range is known and its radiometric reproducibility or precision. Results from several pre-launch tests with a 122-cm Integrating Sphere (IS) used as part of the absolute radiometric calibration experiments for the protoflight TM sensor carried on the LANDSAT-4 satellite are summarized and analyzed. Topics covered include TM radiometric calibration and sensitivity; the TM internal calibrator; and the dynamic range after calibration.

Barker, J. L.↗

LANDSAT-4 Thematic Mapper Calibration and Atmospheric Correction

In order to utilize the quantitative accuracy built into the Thematic Mapper effectively, more attention must be paid to calibration before launch, changes of calibration before launch, changes of calibration with time in orbit, and atmospheric interference with the measurements, especially in the 450 to 520 nanometer band. Recent experience with the Coastal Zone Color Scanner (CZCS) program has led to procedures wherein Rayleigh correction factors can be generated utilizing simultaneous surface truth data that empirically give correct upwelled surface radiances. Instruments, such as the CZCS, have shown that calibration changes first, and to the largest degree, at the shorter wave lengths, with lesser changes as wave length increases. These techniques are utilized to calculate a Rayleigh correction factor that, together with geometric terms, will give an accurate correction for this portion of the atmospheric contribution to the signal.

Hovis, W. A.↗