Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Radiometric Calibration and Geocoded Precision Processing of LANDSAT-4 Multispectral Scanner Products by the Canada Centre for Remote Sensing

Inherent in the method used by CCRS for the radiometric calibration of LANDSAT-4 MSS data is the possibility for the user to convert the corrected digital values to the absolute scene radiance of the target under observation. The generation of the constants needed for this final conversion requires both the pre-launch and post-launch radiometric calibration constants as supplied by NASA. Results of some preliminary comparative studies of the radiometric properties of the LANDSAT-4 MSS versus earlier satellites in the LANDSAT series are presented as well as early observations on the stability of the calibration data, within one scene, within one orbit, and over a period of several months. Residual striping in the corrected products is estimated. The method used to perform precision processing of the LANDSAT MSS data for generating geocoded or map compatible LANDSAT MSS products in the Unviersal Transverse Mercator projection is also reviewed. LANDSAT-4 MSS precision processed products are evaluated for geodetic accuracy, and are compared to similar products from the previous LANDSAT satellites to assess the orbit independent registration accuracy.

Murphy, J.↗

Proton reconstruction with the TOTEM Roman pot detectors for high- β * LHC data

The TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β* data-taking period at $\sqrt({s})$ = 13 TeV in 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved dewpoint-probe calibration

Relatively-simple pressure-control apparatus calibrates dewpoint probes considerably faster than conventional methods, with no loss of accuracy. Technique requires only pressure measurement at each calibration point and single absolute-humidity measurement at beginning of run. Several probes can be calibrated simultaneously and points can be checked above room temperature.

Stephenson, J. G.↗

Intercalibration of Meteorological Satellite Imagers Using VIRS, ATSR-2 and MODIS

Global retrievals of surface, cloud and radiative properties from geostationary (GEO) and low-Earth-orbit (LEO) meteorological satellites require accurate calibration of their imagers. An accurate and consistent calibration increases the reliability and effectiveness of long-term monitoring of climate changes. More emphasis has been placed on calibrating the thermal infrared (IR) channel. The lack of on-board calibration in the visible (VIS) channel has prompted efforts to characterize the degradation of the VIS sensor using vicarious post-launch calibration techniques that measure bright stable desert targets from space and aircraft or using satellite-to-satellite normalizations. While such inter-calibrations are valuable and widely used, the lack of a well-characterized calibration reference source and the lengthy time delay between updates have minimized their effectiveness in climate monitoring. To address these shortcomings, this paper examines the use of research satellite imagers to provide stable calibration references for the visible (VIS, approximately 0.65 micrometers) channels and develops a method for rapid intercalibration of existing satellites. Calibration coefficients are determined for the Geostationary Operational Environmental Satellites (GOES-8 to GOES-10), Geostationary Meteorological Satellite (GMS-5), Meteosat-7, and the NOAA-14 Advanced Very High Resolution Radiometer (AVHRR). As a reference calibration source, this technique uses the self-calibrating sensors on the Tropical Rainfall Measuring Mission (TRMM) Visible Infrared Radiometers (VIRS) or the ERS-2 Along Track Scanning Radiometer (ATSR-2). GOES-8 is calibrated with VIRS and then its calibration is transferred to other GEO or LEO satellites. The absolute accuracy of this technique relies on the assumption that the on-board calibration is stable and well maintained. Minnis et al. assessed the VIRS calibration using comparisons with other self-calibrated satellite sensors including the broadband Clouds and Earth's Radiant Energy System (CERES) scanners, the ERS-2 Along Track Scanning Radiometer (ATSR-2), and the Terra Moderate-resolution Imaging Spectrometer (MODIS). Thus, the VIRS data can be confidently used as the initial reference source.

Nguyen, Louis↗

Sea ice motion measurements from Seasat SAR images

Data from the Seasat synthetic aperture radar (SAR) experiment are analyzed in order to determine the accuracy of this information for mapping the distribution of sea ice and its motion. Data from observations of sea ice in the Beaufort Sea from seven sequential orbits of the satellite were selected to study the capabilities and limitations of spaceborne radar application to sea-ice mapping. Results show that there is no difficulty in identifying homologue ice features on sequential radar images and the accuracy is entirely controlled by the accuracy of the orbit data and the geometric calibration of the sensor. Conventional radargrammetric methods are found to serve well for satellite radar ice mapping, while ground control points can be used to calibrate the ice location and motion measurements in the cases where orbit data and sensor calibration are lacking. The ice motion was determined to be approximately 6.4 + or - 0.5 km/day. In addition, the accuracy of pixel location was found over land areas. The use of one control point in 10,000 sq km produced an accuracy of about + or 150 m, while with a higher density of control points (7 in 1000 sq km) the location accuracy improves to the image resolution of + or - 25 m. This is found to be applicable for both optical and digital data.

Leberl, F.↗

MASS CALIBRATION AND COSMOLOGICAL ANALYSIS OF THE SPT-SZ GALAXY CLUSTER SAMPLE USING VELOCITY DISPERSION σ {sub v} AND X-RAY Y {sub X} MEASUREMENTS

We present a velocity-dispersion-based mass calibration of the South Pole Telescope Sunyaev-Zel'dovich effect survey (SPT-SZ) galaxy cluster sample. Using a homogeneously selected sample of 100 cluster candidates from 720 deg{sup 2} of the survey along with 63 velocity dispersion (σ {sub v}) and 16 X-ray Y {sub X} measurements of sample clusters, we simultaneously calibrate the mass-observable relation and constrain cosmological parameters. Our method accounts for cluster selection, cosmological sensitivity, and uncertainties in the mass calibrators. The calibrations using σ {sub v} and Y {sub X} are consistent at the 0.6σ level, with the σ {sub v} calibration preferring ∼16% higher masses. We use the full SPT{sub CL} data set (SZ clusters+σ {sub v}+Y {sub X}) to measure σ{sub 8}(Ω{sub m}/0.27){sup 0.3} = 0.809 ± 0.036 within a flat ΛCDM model. The SPT cluster abundance is lower than preferred by either the WMAP9 or Planck+WMAP9 polarization (WP) data, but assuming that the sum of the neutrino masses is ∑m {sub ν} = 0.06 eV, we find the data sets to be consistent at the 1.0σ level for WMAP9 and 1.5σ for Planck+WP. Allowing for larger ∑m {sub ν} further reconciles the results. When we combine the SPT{sub CL} and Planck+WP data sets with information from baryon acoustic oscillations and Type Ia supernovae, the preferred cluster masses are 1.9σ higher than the Y {sub X} calibration and 0.8σ higher than the σ {sub v} calibration. Given the scale of these shifts (∼44% and ∼23% in mass, respectively), we execute a goodness-of-fit test; it reveals no tension, indicating that the best-fit model provides an adequate description of the data. Using the multi-probe data set, we measure Ω{sub m} = 0.299 ± 0.009 and σ{sub 8} = 0.829 ± 0.011. Within a νCDM model we find ∑m {sub ν} = 0.148 ± 0.081 eV. We present a consistency test of the cosmic growth rate using SPT clusters. Allowing both the growth index γ and the dark energy equation-of-state parameter w to vary, we find γ = 0.73 ± 0.28 and w = –1.007 ± 0.065, demonstrating that the expansion and the growth histories are consistent with a ΛCDM universe (γ = 0.55; w = –1)

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-575: Novel Quality Assurance Procedure for the Small Animal Radiation Research Platform Using Commercial OSLDs

Purpose: To support radiobiological research with the Xstrahl small animal radiation research platform (SARRP) by developing a simple and effective method using commercially available optically stimulated luminescent dosimeters (OSLDs) that ensures dose output consistency. Methods: The SARRP output is calibrated according to the vendor standards and TG-61 protocol utilizing an ADCL calibrated ion chamber and electrometer at 2 cm depth of solid water. A cross calibration is performed by replacing the ion chamber with five OSLDs at the 2 cm depth. The OSLDs are irradiated to 500 cGy with 220 keV at 13 mA (78s delivery time) with a copper filter for an uncollimated 17×17 cm{sup 2} aperture. Instead of the absolute dose, the total amount of raw counts are collected from the OSLD reader and used for analysis. This constancy procedure was performed two more times over the course of three weeks with two OLSDs for validity. Results: The average reading for all OSLDs is 494939 with a 1-sigma standard deviation of the 5.8%. With an acceptable dose output range of ±10%, the OSLD readings have a counts range of [445445, 544433]. Conclusion: This method of using nanoDot™ OSLDs to perform output constancy checks for the SARRP ensures the output of the device is within 10% from the time of calibration and is convenient as well as time efficient. Because this, the frequency of output checks can be increased, which can improve the output stability for research with this device. The output trend of the SARRP will continue to be monitored in the future to establish a timeline for constancy checks and recalibration.

60 APPLIED LIFE SCIENCES↗

Energy calibration of germanium detectors for the Majorana Demonstrator

The Majorana Demonstrator was a search for neutrinoless double-beta decay (0νββ) in the 76 Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a 228 Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.

47 OTHER INSTRUMENTATION↗

Efficacy of passive sampler collection for atmospheric NO 2 isotopes under simulated environmental conditions

Rationale Nitrogen oxides or NO x (NO x = NO + NO 2 ) play an important role in air quality, atmospheric chemistry, and climate. The isotopic compositions of anthropogenic and natural NO 2 sources are wide‐ranging, and they can be used to constrain sources of ambient NO 2 and associated atmospheric deposition of nitrogen compounds. While passive sample collection of NO 2 isotopes has been used in field studies to determine NO x source influences on atmospheric deposition, this approach has not been evaluated for accuracy or precision under different environmental conditions. Methods The efficacy of NO 2 passive sampler collection for NO 2 isotopes was evaluated under varied temperature and relative humidity (RH) conditions in a dynamic flux chamber. The precision and accuracy of the filter NO 2 collection as nitrite (NO 2 – ) for isotopic analysis were determined using a reference NO 2 gas tank and through inter‐calibration with a modified EPA Method 7. The bacterial denitrifer method was used to convert 20 μM of collected NO 2 – or nitrate (NO 3 – ) into N 2 O and was carried out on an Isoprime continuous flow isotope ratio mass spectrometer. Results δ 15 N‐NO 2 values determined from passive NO 2 collection, in conditions of 11–34 °C, 1–78% RH, have an overall accuracy and precision of ±2.1 ‰, and individual run precision of ±0.6 ‰. δ 18 O‐NO 2 values obtained from passive NO 2 sampler collection, under the same conditions, have an overall precision of ± 1.3 ‰. Conclusions Suitable conditions for passive sampler collection of NO 2 isotopes are in environments ranging from 11 to 34 °C and 1 to 78% RH. The passive NO 2 isotope measurement technique provides an accurate method to determine variations in atmospheric δ 15 N‐NO 2 values and a precise method for determining atmospheric δ 18 O‐NO 2 values. The ability to measure NO 2 isotopes over spatial gradients at the same temporal resolution provides a unique perspective on the extent and seasonality of fluctuations in atmospheric NO 2 isotopic compositions. Copyright © 2017 John Wiley & Sons, Ltd.

Coughlin, Justin G.↗

High-Resolution Imaging of Supraglacial Hydrological Features on the Greenland Ice Sheet with NASA’s Airborne Topographic Mapper (ATM) Instrument Suite

Seasonal meltwater pools on the surface of the Greenland Ice Sheet (GrIS) during late spring and summer in lakes on the surface and transforms the ice sheet's surface into a wet environment in the ablation zone below the equilibrium line. These supraglacial lakes in topographic lows on the ice surface are connected by a dendritic pattern of meandering streams and channels that together form a hydrological system consisting of supra-, en-, and subglacial components. Here, we use lidar data from NASA's Airborne Topographic Mapper (ATM) instrument suite and high-resolution optical imagery collected as part of Operation IceBridge (OIB) in spring 2019 over the GrIS to develop methods for the study of supraglacial hydrological features. While airborne surveys have a limited temporal and spatial coverage compared to imaging spaceborne sensors, their high footprint density and high-resolution imagery reveal a level of detail that is currently not obtainable from spaceborne measurements. The accuracy and resolution of airborne measurements complement spaceborne measurements, can support calibration and validation of spaceborne methods, and provide information necessary for high-resolution process studies of the supraglacial hydrological system on the GrIS that currently cannot be achieved from spaceborne observations alone.

ATM↗

Simultaneous elastic and photoelastic calibration of birefringent orthotropic model materials

Transmission photoelastic analysis of composite models has been shown in recent years to be a viable stress analysis method for composite structures. However, difficulties in the fabrication of the model materials require the development of efficient mechanical and optical calibration procedures. In this paper, the methods for measuring elastic and photoelastic constants of composites are briefly reviewed. Then a new method, utilizing a relatively small calibration specimen, is described. In this method, electrical resistance strain gauges are mounted at selected points of a half-plane model and photoelastic measurements and strain readings are simultaneously taken. The data are processed by a least-squares procedure to yield the elastic and photoelastic constants. Comparison of results obtained by the proposed method with the results from conventional tests shows good agreement.

Prabhakaran, R.↗

Vicarious Calibration of EO-1 Hyperion

The Hyperion imaging spectrometer on the Earth Observing-1 satellite is the first high-spatial resolution imaging spectrometer to routinely acquire science-grade data from orbit. Data gathered with this instrument needs to be quantitative and accurate in order to derive meaningful information about ecosystem properties and processes. Also, comprehensive and long-term ecological studies require these data to be comparable over time, between coexisting sensors and between generations of follow-on sensors. One method to assess the radiometric calibration is the reflectance-based approach, a common technique used for several other earth science sensors covering similar spectral regions. This work presents results of radiometric calibration of Hyperion based on the reflectance-based approach of vicarious calibration implemented by University of Arizona during 2001 2005. These results show repeatability to the 2% level and accuracy on the 3 5% level for spectral regions not affected by strong atmospheric absorption. Knowledge of the stability of the Hyperion calibration from moon observations allows for an average absolute calibration based on the reflectance-based results to be determined and applicable for the lifetime of Hyperion.

McCorkel, Joel↗

Image synthesis for SAR system, calibration and processor design

The Point Scattering Method of simulating radar imagery rigorously models all aspects of the imaging radar phenomena. Its computational algorithms operate on a symbolic representation of the terrain test site to calculate such parameters as range, angle of incidence, resolution cell size, etc. Empirical backscatter data and elevation data are utilized to model the terrain. Additionally, the important geometrical/propagation effects such as shadow, foreshortening, layover, and local angle of incidence are rigorously treated. Applications of radar image simulation to a proposed calibrated SAR system are highlighted: soil moisture detection and vegetation discrimination.

Holtzman, J. C.↗

Machine learning on FPGA for event selection

Real-time data processing is a frontier field in experimental particle physics. The application of FPGAs at the trigger level is used by many current and planned experiments (CMS, LHCb, Belle2, PANDA). Usually they use conventional processing algorithms. LHCb has implemented Machine Learning (ML) elements for real-time data processing with a triggered readout system that runs most of the ML algorithms on a computer farm. The work described in this article aims to test the ML-FPGA algorithms for streaming data acquisition. Herein, there are many experiments working in this area and they have a lot in common, but there are many specific solutions for detector and accelerator parameters that are worth exploring further. This report describes the purpose of the work and progress in evaluating the ML-FPGA application.

47 OTHER INSTRUMENTATION↗

Wavefront Calibration Testing of the James Webb Space Telescope Primary Mirror Center of Curvature Optical Assembly

The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) consists of a 6.6 meter clear aperture, all-reflective, three-mirror anastigmat!. The 18-segment primary mirror (PM) presents unique and challenging assembly, integration, alignment and testing requirements. A full aperture center of curvature optical test is performed in cryogenic vacuum conditions at the integrated observatory level to verify PM performance requirements. Two wavefront calibration tests are utilized to verify the low and Mid/High spatial frequency performance ofthe test system. In this paper the methods and results of the wavefront calibration tests are presented.

Olczak, Gene↗

Steady Surface Pressure Measurement via the Lifetime Method With High-Speed Cameras in NASA's Unitary Plan Wind Tunnel

High spatial resolution measurement of steady surface pressure via pressure-sensitive paint at NASA Ames has traditionally relied on specialized cameras equipped to accumulate charge over multiple exposures, whereas measurement of the fluctuating component of pressure uses an altogether separate set of high-speed cameras. To reduce complexity of installation, data acquisition, and processing, we have implemented methods to use a single set of commercial off-the-shelf cameras to produce both steady and unsteady pressure measurements. Both imaging systems were installed in the 11-by 11-foot NASA Ames Unitary Plan Wind Tunnel and acquired images of a scaled model of the Space Launch System Block 1B Crew and Cargo configurations over a variety of flow conditions. This work focuses on methods for data acquisition, processing, and calibration to produce steady-state pressure estimates on the surface of the wind tunnel model based on the lifetime method. It will then compare the steady solutions produced by the legacy and high-speed imaging systems.

Pressure Sensitive Paint↗

Analysis and Evaluation of NASA's MK40B Six-Component Task Balance

The MK40B balance is NASA's newest balance of Task design. Its load range was optimized for use in the NASA Ames 11-ft Transonic Wind Tunnel. The balance was calibrated in 2019 in Calspan's Automatic Balance Calibration System. The data analysis was performed at the Ames Balance Calibration Laboratory. First, bi-directional characteristics of the six gage outputs of the balance were assessed by applying a semi-empirical test to the calibration data. These tests indicated that four of the six gages have bi-directional characteristics. Therefore, the use of absolute value terms in the regression models of the calibration data is justified. Then, the machine calibration data was analyzed using both the Non-Iterative and the Iterative Method. Analysis results for the two methods were compared using the percent contributions, the calibration load residuals, the primary sensitivities, and the principle linear terms. These results confirmed that the two methods describe bi-directional characteristics of the balance gages correctly. In addition, it was concluded that the load prediction accuracies of the two methods are the same for all practical purposes.

wind tunnel balance↗

Big Data Mining for Applied Energy Savings in Buildings

Residential and commercial buildings in China, India, the United States (US), United Kingdom (UK), and Italy consume 39-45% of each nation's primary energy (approximately 73% of electricity). Building energy models can be used to automatically optimize the return-on-investment for retrofits to improve a building’s energy efficiency. However, with an average of 3,000 building descriptors necessary to accurately simulate a single building, there is a market need to reduce the transaction cost for creating a simulatable model for every building in a city and calibrate the models to utility data prior to capital expenditures. Oak Ridge National Laboratory has utilized two of the world’s fastest supercomputers, assembled unique datasets, and developed innovative algorithms for big data mining to produce the Automatic detection and creation of Building Energy Models (AutoBEM) technology for urban-scale energy modeling. The project developed the world’s most accurate method for determining building footprints from satellite imagery and the world’s fastest building energy model generator. The team has also leveraged a total of eight supercomputers to analyze the best methods, metrics, and algorithms for calibrating building models to measured data within 4% of hourly electricity use; well beyond current industry standards necessary for private-sector financing. The project developed the world’s fastest buildings simulator, over 8 million simulations totaling over 200TB, and mined this data with over 130,000 parallel artificial intelligence algorithmic instances to develop the world’s best calibration algorithm in terms of accuracy, runtime, and robustness.

New, Joshua↗