Comparison of Two Forward Topologies as the Front End Converter for a Space-Qualified Distributed Power System.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
As energy companies and governments attempt to get more from the existing power grid and other critical infrastructures, more automatic control systems are being applied 1-2. With this greater reliance on network-based, digital automation and the stresses of pressing existing infrastructure for greater performance, the power grid and underlying systems have become more susceptible to both malicious attacks and unexpected, natural threats. Governments and other stakeholders have chosen to address infrastructure issues by the implementation of a smarter grid. In the smart grid, operators and control systems supervise power generation, distribution, transmission, and loads to utilize these assets most efficiently3. Such extensive monitoring and control over a distributed system cause complexity that challenge systems designers and human operators in new ways. In addition, cyber vulnerability of these systems has been illustrated in many recent articles on malicious attacks to electric power systems and other similar infrastructure for natural gas, water and communications4. It is therefore critical in the next generation of control systems that resilience plays a large and critical role in the grid design and development. Resilient control systems is a field of research that seeks solutions to the complexity through a holistic approach that combines cognitive science, computer security, communications, and control systems. To enable future researchers and practitioners to assist with designing more resilient systems, science, technology, engineering and mathematics education needs to incorporate interdisciplinary topics. While electrical engineering and computer science programs in the nation include a cyber-security perspective, few if any have focused on the unique control system aspects. Human cognitive aspects are most definitely not addressed in technology education discourse. To this end, a class and education tools in resilient control systems have been created.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A solar light distribution system includes a solar light concentrator that is affixed externally to a light transfer tube. Solar light waves are processed by the concentrator into a collimated beam of light, which is then transferred through a light receiving port and into the light transfer tube. A reflector redirects the collimated beam of light through the tube to a light distribution port. The interior surface of the light transfer tube is highly reflective so that the light transfers through the tube with minimal losses. An interchangeable luminaire is attached to the light distribution port and provides light inside of a structure. A sun tracking device rotates the concentrator and the light transfer tube to optimize the receiving of solar light by the concentrator throughout the day. The system provides interior lighting that uses only renewable energy sources, and releases no carbon dioxide emissions into the atmosphere.
Distribution system operators (DSOs) world-wide foresee a rapid roll-out of distributed energy resources. From the system perspective, their reliable and cost effective integration requires accounting for their physical properties in operating tools used by the DSO. This work describes an decomposable approach to leverage the dispatch flexibility of thermostatically controlled loads (TCLs) for operating distribution systems with a high penetration level of photovoltaic resources. Each TCL ensemble is modeled using the Markov Decision Process (MDP). The MDP model is then integrated with a chance constrained optimal power flow that accounts for the uncertainty of PV resources. Since the integrated optimization model cannot be solved efficiently by existing dynamic programming methods or off-the-shelf solvers, this paper proposes an iterative Spatio-Temporal Dual Decomposition algorithm (ST-D2). Finally, we demonstrate the merits of the proposed integrated optimization and ST-D2 algorithm on the IEEE 33-bus test system.
Practical distribution system contains many nodes and short branches. As a result, a more efficient and stable distribution state estimation (DSE) algorithm is needed to properly handle the inverse operation of its large-scale ill-conditioned information matrix. This paper proposed a two-stage DSE algorithm to transform the inverse operation into addition and multiplication operations in a recursive manner. It includes pseudo measurement preprocessing in the offline stage where an approximate linear estimator is adopted to relieve most of computation burdens, and real-time correction in the online stage where a nonlinear estimator is used to update the estimation. Numerical results of the method applied to both IEEE standard test systems and an actual distribution system show the accuracy and effectiveness of the proposed algorithm.
Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.
This poster provides an overview of the performance evaluation of distributed energy resource management via advanced hardware-in-the-loop simulation.