Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Structure of dark matter halos in warm dark matter models and in models with long-lived charged massive particles

We study the formation of non-linear structures in warm dark matter (WDM) models and in a long-lived charged massive particle (CHAMP) model. CHAMPs with a decay lifetime of about 1 yr induce characteristic suppression in the matter power spectrum at subgalactic scales through acoustic oscillations in the thermal background. We explore structure formation in such a model. We also study three WDM models, where the dark matter particles are produced through the following mechanisms: i) WDM particles are produced in the thermal background and then kinematically decoupled; ii) WDM particles are fermions produced by the decay of thermal heavy bosons; and iii) WDM particles are produced by the decay of non-relativistic heavy particles. We show that the linear matter power spectra for the three models are all characterised by the comoving Jeans scale at the matter-radiation equality. Furthermore, we can also describe the linear matter power spectrum for the long-lived CHAMP model in terms of a suitably defined characteristic cut-off scale k{sub Ch}, similarly to the WDM models. We perform large cosmological N-body simulations to study the non-linear growth of structures in these four models. We compare the halo mass functions, the subhalo mass functions, and the radial distributions of subhalos in simulated Milky Way-size halos. For the characteristic cut-off scale k{sub cut} = 51 h Mpc{sup −1}, the subhalo abundance ( ∼ 10{sup 9}M{sub sun}) is suppressed by a factor of ∼ 10 compared with the standard ΛCDM model. We then study the models with k{sub cut} ≅ 51, 410, 820 h Mpc{sup −1}, and confirm that the halo and the subhalo abundances and the radial distributions of subhalos are indeed similar between the different WDM models and the long-lived CHAMP model. The result suggests that the cut-off scale k{sub cut} not only characterises the linear power spectra but also can be used to predict the non-linear clustering properties. The radial distribution of subhalos in Milky Way-size halos is consistent with the observed distribution for k{sub cut} ∼ 50−800 h Mpc{sup −1}; such models resolve the so-called ''missing satellite problem''.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation and beamline experiments for the superconducting electron cyclotron resonance ion source VENUS

The particle-in-cell code WARP has been enhanced to incorporate both two- and three-dimensional sheath extraction models giving WARP the capability of simulating entire ion beam transport systems including the extraction of beams from plasma sources. In this article, we describe a method of producing initial ion distributions for plasma extraction simulations in electron cyclotron resonance (ECR) ion sources based on experimentally measured sputtering on the source biased disk. Using this initialization method, we present preliminary results for extraction and transport simulations of an oxygen beam and compare them with experimental beam imaging on a quartz viewing plate for the superconducting ECR ion source VENUS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric characterization of a dedicated breast computed tomography clinical prototype

Purpose: To investigate the glandular dose magnitudes and characteristics resulting from image acquisition using a dedicated breast computed tomography (BCT) clinical prototype imaging system. Methods: The x-ray spectrum and output characteristics of a BCT clinical prototype (Koning Corporation, West Henrietta, NY) were determined using empirical measurements, breast phantoms, and an established spectrum model. The geometry of the BCT system was replicated in a Monte Carlo-based computer simulation using the GEANT4 toolkit and was validated by comparing the simulated results for exposure distribution in a standard 16 cm CT head phantom with those empirically determined using a 10 cm CT pencil ionization chamber and dosimeter. The computer simulation was further validated by replicating the results of a previous BCT dosimetry study. Upon validation, the computer simulation was modified to include breasts of varying sizes and homogeneous compositions spanning those encountered clinically, and the normalized mean glandular dose resulting from BCT was determined. Using the system's measured exposure output determined automatically for breasts of different size and density, the mean glandular dose for these breasts was computed and compared to the glandular dose resulting from mammography. Finally, additional Monte Carlo simulations were performed to study how the glandular dose values vary within the breast tissue during acquisition with both this BCT prototype and a typical craniocaudal (CC) mammographic acquisition. Results: This BCT prototype uses an x-ray spectrum with a first half-value layer of 1.39 mm Al and a mean x-ray energy of 30.3 keV. The normalized mean glandular dose for breasts of varying size and composition during BCT acquisition with this system ranges from 0.278 to 0.582 mGy/mGy air kerma with the reference air kerma measured in air at the center of rotation. Using the measured exposure outputs for the tube currents automatically selected by the system for the breasts of different sizes and densities, the mean glandular dose for a BCT acquisition with this prototype system varies from 5.6 to 17.5 mGy, with the value for a breast of mean size and composition being 17.06 mGy. The glandular dose throughout the breast tissue of this mean breast varies by up to {+-}50% of the mean value. During a typical CC view mammographic acquisition of an equivalent mean breast, which typically results in a mean glandular dose of 2.0-2.5 mGy, the glandular dose throughout the breast tissue varies from {approx}15% to {approx}400% of the mean value. Conclusions: Acquisition of a BCT image with the automated tube output settings for a mean breast with the Koning Corp. clinical prototype results in mean glandular dose values approximately equivalent to three to five two-view mammographic examinations for a similar breast. For all breast sizes and compositions studied, this glandular dose ratio between acquisition with this BCT prototype and two-view mammography ranges from 1.4 to 7.2. In mammography, portions of the mean-sized breast receive a considerably higher dose than the mean value for the whole breast. However, only a small portion of a breast undergoing mammography would receive a glandular dose similar to that from BCT.

60 APPLIED LIFE SCIENCES↗

Assessing North Atlantic Tropical Cyclone Rainfall Hazard Using Engineered-Synthetic Storms and a Physics-Based Tropical Cyclone Rainfall Model

In this study, we design a statistical method to couple observations with a physics-based tropical cyclone (TC) rainfall model (TCR) and engineered-synthetic storms for assessing TC rainfall hazard. We first propose a bias-correction method to minimize the errors induced by TCR via matching the probability distribution of TCR-simulated historical TC rainfall with gauge observations. Then we assign occurrence probabilities to engineered-synthetic storms to reflect local climatology, through a resampling method that matches the probability distribution of a newly proposed storm parameter named rainfall potential (POT) in the synthetic dataset with that in the observation. POT is constructed to include several important storm parameters for TC rainfall such as TC intensity, duration, and distance and environmental humidity near landfall, and it is shown to be correlated with TCR-simulated rainfall. The proposed method has a satisfactory performance in reproducing the rainfall hazard curve in various locations in the continental United States; it is an improvement over the traditional joint probability method (JPM) for TC rainfall hazard assessment.

54 ENVIRONMENTAL SCIENCES↗

Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system

Purpose: To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). Methods: An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior–inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. Results: (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in static and dynamic conditions. No statistically significant differences were found between static and dynamic cases, confirming the high degree of accuracy of the Synchrony RTS. Conclusions: The presented methods and measurements verified the mechanical and dosimetric accuracy of the Synchrony RTS. Their method confirms the fact that the RTS, if used properly, is able to treat a moving target with great precision. By combining PinPoint ion chamber, EBT3 films, and gamma evaluation of dose distributions, their DQA method robustly validated the effectiveness of CyberKnife and Synchrony system.

60 APPLIED LIFE SCIENCES↗

External-Beam Accelerated Partial Breast Irradiation Using Multiple Proton Beam Configurations

Purpose: To explore multiple proton beam configurations for optimizing dosimetry and minimizing uncertainties for accelerated partial breast irradiation (APBI) and to compare the dosimetry of proton with that of photon radiotherapy for treatment of the same clinical volumes. Methods and Materials: Proton treatment plans were created for 11 sequential patients treated with three-dimensional radiotherapy (3DCRT) photon APBI using passive scattering proton beams (PSPB) and were compared with clinically treated 3DCRT photon plans. Monte Carlo calculations were used to verify the accuracy of the proton dose calculation from the treatment planning system. The impact of range, motion, and setup uncertainty was evaluated with tangential vs. en face beams. Results: Compared with 3DCRT photons, the absolute reduction of the mean of V100 (the volume receiving 100% of prescription dose), V90, V75, V50, and V20 for normal breast using protons are 3.4%, 8.6%, 11.8%, 17.9%, and 23.6%, respectively. For breast skin, with the similar V90 as 3DCRT photons, the proton plan significantly reduced V75, V50, V30, and V10. The proton plan also significantly reduced the dose to the lung and heart. Dose distributions from Monte Carlo simulations demonstrated minimal deviation from the treatment planning system. The tangential beam configuration showed significantly less dose fluctuation in the chest wall region but was more vulnerable to respiratory motion than that for the en face beams. Worst-case analysis demonstrated the robustness of designed proton beams with range and patient setup uncertainties. Conclusions: APBI using multiple proton beams spares significantly more normal tissue, including nontarget breast and breast skin, than 3DCRT using photons. It is robust, considering the range and patient setup uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sequentially coupled flow and geomechanical simulation with a discrete fracture model for analyzing fracturing fluid recovery and distribution in fractured ultra-low permeability gas reservoirs

More accurate characterization and prediction of the in-situ distribution of fracturing fluid in fractured reservoirs are needed for enhancing well productivity. In this study, an implicit-sequentially coupled flow/geomechanics simulator incorporating an efficient discrete fracture model is developed to model fluid distribution and recovery performance of ultra-low permeability gas reservoirs. The finite-volume and finite-element methods are used for space discretization of the flow and geomechanics equations, respectively, while the backward Euler method is employed for time discretization. The flow and geomechanics equations are solved sequentially based on fixed-stress splitting. An efficient discrete-fracture model is used to explicitly model the fractured system. Flexible unstructured gridding is employed to model arbitrarily-oriented fractures. The interrelations among pore volume, permeability and geomechanical conditions are considered dynamically using two-way coupled flow and geomechanics computations. The geometry of fracture (networks) due to hydraulic fracturing has significant impacts on the fracturing fluid recovery efficiency and ensuing fluid distribution. Under the same injection volume, the fracturing fluid recovery is higher when the fracture geometry is planar. Fluid recovery is relatively lower whenever natural fractures are activated during fracturing treatments; flowback time is also shortened when complex fracture network with enlarged fracture interface is present. Fracturing fluid in hydraulic fractures may leak off into the natural fractures and subsequently imbibes into the surrounding matrix due to capillarity effects. The fracturing fluid recovery and in-situ fluid distribution are sensitive to the shut-in duration and fracture closure behavior. This study analyzes the coupled flow-geomechanical responses of fractured gas reservoirs during the post-fracturing periods. Understanding the fate of the fracturing fluid can provide insights on, to some extent, the stimulated fracture volume, size of the water invasion zone, and efficiency of the fracturing design. The simulation predictions can also provide more accurate initial reservoir conditions (e.g. distributions of different phases and pressure) for long-term well performance estimation.

42 ENGINEERING↗

Numerical simulation of shock initiation of Ni/Al multilayered composites

The initiation of chemical reaction in cold-rolled Ni/Al multilayered composites by shock compression is investigated numerically. A simplified approach is adopted that exploits the disparity between the reaction and shock loading timescales. The impact of shock compression is modeled using CTH simulations that yield pressure, strain, and temperature distributions within the composites due to the shock propagation. The resulting temperature distribution is then used as initial condition to simulate the evolution of the subsequent shock-induced mixing and chemical reaction. To this end, a reduced reaction model is used that expresses the local atomic mixing and heat release rates in terms of an evolution equation for a dimensionless time scale reflecting the age of the mixed layer. The computations are used to assess the effect of bilayer thickness on the reaction, as well as the impact of shock velocity and orientation with respect to the layering. Computed results indicate that initiation and evolution of the reaction are substantially affected by both the shock velocity and the bilayer thickness. In particular, at low impact velocity, Ni/Al multilayered composites with thick bilayers react completely in 100 ms while at high impact velocity and thin bilayers, reaction time was less than 100 μs. Quantitative trends for the dependence of the reaction time on the shock velocity are also determined, for different bilayer thickness and shock orientation.

36 MATERIALS SCIENCE↗

The multi-scattering model for calculations of positron spatial distribution in the multilayer stacks, useful for conventional positron measurements

The spatial distribution of positrons emitted from radioactive isotopes into stacks or layered samples is a subject of the presented report. It was found that Monte Carlo (MC) simulations using GEANT4 code are not able to describe correctly the experimental data of the positron fractions in stacks. The mathematical model was proposed for calculations of the implantation profile or positron fractions in separated layers or foils being components of a stack. The model takes into account only two processes, i.e., the positron absorption and backscattering at interfaces. The mathematical formulas were applied in the computer program called LYS-1 (layers profile analysis). The theoretical predictions of the model were in the good agreement with the results of the MC simulations for the semi infinite sample. The experimental verifications of the model were performed on the symmetrical and non-symmetrical stacks of different foils. The good agreement between the experimental and calculated fractions of positrons in components of a stack was achieved. Also the experimental implantation profile obtained using the depth scanning of positron implantation technique is very well described by the theoretical profile obtained within the proposed model. The LYS-1 program allows us also to calculate the fraction of positrons which annihilate in the source, which can be useful in the positron spectroscopy.

97 MATHEMATICS AND COMPUTING↗

Alignment of gold nanorods by angular photothermal depletion

In this paper, we demonstrate that a high degree of alignment can be imposed upon randomly oriented gold nanorod films by angular photothermal depletion with linearly polarized laser irradiation. The photothermal reshaping of gold nanorods is observed to follow quadratic melting model rather than the threshold melting model, which distorts the angular and spectral hole created on 2D distribution map of nanorods to be an open crater shape. We have accounted these observations to the alignment procedures and demonstrated good agreement between experiment and simulations. The use of multiple laser depletion wavelengths allowed alignment criteria over a large range of aspect ratios, achieving 80% of the rods in the target angular range. We extend the technique to demonstrate post-alignment in a multilayer of randomly oriented gold nanorod films, with arbitrary control of alignment shown across the layers. Photothermal angular depletion alignment of gold nanorods is a simple, promising post-alignment method for creating future 3D or multilayer plasmonic nanorod based devices and structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A pressure consistent bridge correction of Kovalenko-Hirata closure in Ornstein-Zernike theory for Lennard-Jones fluids by apparently adjusting sigma parameter

Ornstein-Zernike (OZ) integral equation theory is known to overestimate the excess internal energy, U{sup ex}, pressure through the virial route, P{sub v}, and excess chemical potential, μ{sup ex}, for one-component Lennard-Jones (LJ) fluids under hypernetted chain (HNC) and Kovalenko-Hirata (KH) approximatons. As one of the bridge correction methods to improve the precision of these thermodynamic quantities, it was shown in our previous paper that the method to apparently adjust σ parameter in the LJ potential is effective [T. Miyata and Y. Ebato, J. Molec. Liquids. 217, 75 (2016)]. In our previous paper, we evaluated the actual variation in the σ parameter by using a fitting procedure to molecular dynamics (MD) results. In this article, we propose an alternative method to determine the actual variation in the σ parameter. The proposed method utilizes a condition that the virial and compressibility pressures coincide with each other. This method can correct OZ theory without a fitting procedure to MD results, and possesses characteristics of keeping a form of HNC and/or KH closure. We calculate the radial distribution function, pressure, excess internal energy, and excess chemical potential for one-component LJ fluids to check the performance of our proposed bridge function. We discuss the precision of these thermodynamic quantities by comparing with MD results. In addition, we also calculate a corrected gas-liquid coexistence curve based on a corrected KH-type closure and compare it with MD results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward the core-edge coupling of delta-f and total-f gyrokinetic models

The coupling of core reduced delta-f and edge total-f gyrokinetic models could enable a significant speed-up of the whole device modeling simulations. It is thus interesting to compare these models in the core where they will be coupled. The main difference between these models is the presence of the zeroth order term on the right-hand side of the total-f gyrokinetic equation. This term is responsible for driving a radial electric field that is also associated with Geodesic acoustic mode-like oscillations. To investigate the coupling between these models, the subsequent large-scale gyrokinetic 3D turbulence simulations have been performed starting from an already saturated gyrokinetic axisymmetric equilibria (collisions are not included). This work has also been extended to couple different axisymmetric and turbulent models available in XGC. It is shown that the radial electric field and its drive have to be taken care of consistently while coupling different models together.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of the artificial neural network for reconstructing the internal-structure image of a random medium by spatial characteristics of backscattered optical radiation

The feasibility of using an artificial neural network (ANN), which is the standard Matlab tool, for non-invasive (based on the data of backscattering) diagnostics of macro-inhomogeneities, localised at subsurface layers of the turbid strongly scattering medium was shown. The spatial and angle distribution of the backscattered optical radiation was calculated by using the Monte-Carlo method combining the modelling of effective optical paths and the use of statistical weights. It was shown that application of the backscattering method together with the ANN allows solving inverse problems for determining the average radius of the scattering particles and for reconstructing the images of structural elements within the medium with a high accuracy. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BULLET CLUSTER: A CHALLENGE TO {Lambda}CDM COSMOLOGY

To quantify how rare the bullet-cluster-like high-velocity merging systems are in the standard {Lambda} cold dark matter (CDM) cosmology, we use a large-volume (27 h {sup -3} Gpc{sup 3}) cosmological N-body MICE simulation to calculate the distribution of infall velocities of subclusters around massive main clusters. The infall velocity distribution is given at (1-3)R{sub 200} of the main cluster (where R{sub 200} is similar to the virial radius), and thus it gives the distribution of realistic initial velocities of subclusters just before collision. These velocities can be compared with the initial velocities used by the non-cosmological hydrodynamical simulations of 1E0657-56 in the literature. The latest parameter search carried out by Mastropietro and Burkert has shown that an initial velocity of 3000 km s{sup -1} at about 2R{sub 200} is required to explain the observed shock velocity, X-ray brightness ratio of the main and subcluster, X-ray morphology of the main cluster, and displacement of the X-ray peaks from the mass peaks. We show that such a high infall velocity at 2R{sub 200} is incompatible with the prediction of a {Lambda}CDM model: the probability of finding 3000 km s{sup -1} in (2-3)R{sub 200} is between 3.3 x 10{sup -11} and 3.6 x 10{sup -9}. A lower velocity, 2000 km s{sup -1} at 2R{sub 200}, is also rare, and moreover, Mastropietro and Burkert have shown that such a low initial velocity does not reproduce the X-ray brightness ratio of the main and subcluster or morphology of the main cluster. Therefore, we conclude that the existence of 1E0657-56 is incompatible with the prediction of a {Lambda}CDM model, unless a lower infall velocity solution for 1E0657-56 with {approx}<1800 km s{sup -1} at 2R{sub 200} is found.

79 ASTRONOMY AND ASTROPHYSICS↗

Formulation of Three-Phase State Estimation Problem Using a Virtual Reference

State Estimation (SE) is the backbone of modern Energy Management System (EMS) due its capability of processing real time measurements and provide reliable information to system operators. Since its introduction to power systems in the 70’s, SE has been widely used in transmission networks. Distribution grids on the other hand lack sufficient number of real time measurements, and for that reason SE has not been widely implemented on these systems. The recent increase in the number of renewable energy sources connected to the grid at lower voltage levels, the advent of Distribution Automation (DA) and Smart Grids necessitate closer monitoring of distribution networks and thus forcing utilities to upgrade their operations and deploy Advanced Distribution Management Sytems (ADMS). Therefore, Distribution System State Estimation (DSE) is paramount to provide real time monitoring of active distribution grids. This papers investigates the formulation of the three-phase distribution state estimation where in the most general case, none of the system buses may have balanced three phase voltages. In such a case, the choice and definition of the slack bus need to be revisited. Most of the existing work arbitrarily assign the root bus of the distribution feeder as the balanced three-phase reference which may not be realistic for today’s active distribution systems. This paper addresses this shortcoming of the existing SE formulations by introducing a virtual reference bus. Here, the proposed approach is effectively validated by simulations carried out on distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Midplane neutral density profiles in the National Spherical Torus Experiment

Atomic and molecular density data in the outer midplane of NSTX [Ono et al., Nucl. Fusion 40, 557 (2000)] are inferred from tangential camera data via a forward modeling procedure using the DEGAS 2 Monte Carlo neutral transport code. The observed Balmer-b light emission data from 17 shots during the 2010 NSTX campaign display no obvious trends with discharge parameters such as the divertor Balmer-a emission level or edge deuterium ion density. Simulations of 12 time slices in 7 of these discharges produce molecular densities near the vacuum vessel wall of 2–8 x 10 17 m -3 and atomic densities ranging from 1 to 7 x 10 16 m -3 ; neither has a clear correlation with other parameters. Validation of the technique, begun in an earlier publication, is continued with an assessment of the sensitivity of the simulated camera image and neutral densities to uncertainties in the data input to the model. The simulated camera image is sensitive to the plasma profiles and virtually nothing else. The neutral densities at the vessel wall depend most strongly on the spatial distribution of the source; simulations with a localized neutral source yield densities within a factor of two of the baseline, uniform source, case. The uncertainties in the neutral densities associated with other model inputs and assumptions are ≤ 50%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Blockchain for Fault-Tolerant Grid Operations

Radial topology and vast geographic coverage make distribution systems prone to widespread power outages upon the failure of a single (or multiple) upstream component. Fault-handling algorithms depend heavily on correct estimations of the system’s state to effectively isolate the affected area and reduce the number of affected customers while maintaining operational safety. The work described here leverages the core features of distributed, consensus-based decision-making processes and the immutability of blockchain, and demonstrates their value in improving fault-tolerant grid operations. In this work, blockchain was used to create a trusted data-sharing platform that enables independent actors to reconstruct the system state; this enables distributed resources to make intelligent decisions with limited knowledge. Although the process requires data sharing, its algorithms have been designed to limit the amount of private information that is exchanged, which helps preserve business-sensitive data and maintain customer privacy. In addition, by reducing the information that must be shared, the communication requirements are also reduced; (however, an in-depth analysis of the communication requirements is beyond the scope of this project). The proposed use cases are intended to represent a foundational basis for third parties to develop functional solutions that can eventually be deployed in the field. To further provide guidance, the envisioned use cases have incorporated design requirements that consider the blockchain characteristics and a need to limit information from surrounding resources, which preserve the assumption and the possibility that such resources could belong to different entities. This report presents a detailed design of the three use cases with the tools needed to enable the analysis being tested. The implemented gross error detection method can detect mismatches when the error exceeds 3.8 times the sensor’s rated accuracy. Detection of the circuit breaker state successfully identified the correct states across all simulation tests. A distribution-system power-flow solution in the simulator OpenDSS generally possesses a convergency tolerance of 0.01% on the voltage magnitude. The evaluation of possible reconnection using voltage magnitude—preserving the data ownership—has a voltage magnitude difference smaller than 0.001% from the OpenDSS result. The results preserving data ownership have a difference within the expected power flow tolerance with full knowledge of the system, which surpasses expectations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

STATISTICAL PROPERTIES OF GAMMA-RAY BURST POLARIZATION

The emission mechanism and the origin and structure of magnetic fields in gamma-ray burst (GRB) jets are among the most important open questions concerning the nature of the central engine of GRBs. In spite of extensive observational efforts, these questions remain to be answered and are difficult or even impossible to infer with the spectral and light-curve information currently collected. Polarization measurements will lead to unambiguous answers to several of these questions. Recent developments in X-ray and {gamma}-ray polarimetry techniques have demonstrated a significant increase in sensitivity, enabling several new mission concepts, e.g., Polarimeters for Energetic Transients (POET), providing wide field of view and broadband polarimetry measurements. If launched, missions of this kind would finally provide definitive measurements of GRB polarizations. We perform Monte Carlo simulations to derive the distribution of GRB polarizations in three emission models; the synchrotron model with a globally ordered magnetic field (SO model), the synchrotron model with a small-scale random magnetic field (SR model), and the Compton drag model (CD model). The results show that POET, or other polarimeters with similar capabilities, can constrain the GRB emission models by using the statistical properties of GRB polarizations. In particular, the ratio of the number of GRBs for which the polarization degrees can be measured to the number of GRBs that are detected (N{sub m} /N{sub d} ) and the distributions of the polarization degrees ({pi}) can be used as the criteria. If N{sub m} /N{sub d} > 30% and {pi} is clustered between 0.2 and 0.7, the SO model will be favored. If, instead, N{sub m} /N{sub d} < 15%, then the SR or CD model will be favored. If several events with {pi}>0.8 are observed, then the CD model will be favored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗