Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution Grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Investigation of Advanced Counterrotation Blade Configuration Concepts for High Speed Turboprop Systems. Task 3: Advanced Fan Section Grid Generator Final Report and Computer Program User's Manual

A procedure is studied for generating three-dimensional grids for advanced turbofan engine fan section geometries. The procedure constructs a discrete mesh about engine sections containing the fan stage, an arbitrary number of axisymmetric radial flow splitters, a booster stage, and a bifurcated core/bypass flow duct with guide vanes. The mesh is an h-type grid system, the points being distributed with a transfinite interpolation scheme with axial and radial spacing being user specified. Elliptic smoothing of the grid in the meridional plane is a post-process option. The grid generation scheme is consistent with aerodynamic analyses utilizing the average-passage equation system developed by Dr. John Adamczyk of NASA Lewis. This flow solution scheme requires a series of blade specific grids each having a common axisymmetric mesh, but varying in the circumferential direction according to the geometry of the specific blade row.

Crook, Andrew J.↗

Distributed Energy Resource Management Systems: Preserving Customer Privacy through K-Anonymity

The smart grid represents the next generation of electricity distribution systems that utilizes recent technological innovations. It uses digital communication between its components and entities to attain more automation, self-sufficiency, and reliability. One of the many concerns in smart grid digital communication discussions is the possibility of violating customers’ privacy. Violating customers’ privacy imposes a significant barrier as smart grid desirable attributes are tightly tied to customers’ participation. Employing privacy models can address concerns regarding information privacy in smart grid digital communication. In this work, we provide an approach to utilizing K-anonymity to ensure data within the system excludes Personally Identifiable Information. Results suggest that a dynamically generated generalization hierarchy minimizes information loss incurred by the anonymization process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Synchronous Machine Grid-Forming Inverter Model Specification (REGFM_B1)

This report describes a generic virtual synchronous machine (VSM) grid-forming inverter (GFM) model - REGFM_B1. The initial model specification was proposed by Pacific Northwest National Laboratory (PNNL), General Electric (GE), and Electric Power Research Institute (EPRI). Siemens Gamesa Renewable Energy (SGRE) also provided inputs to the specification. The model specification has been revised multiple times based on the discussions between all the contributors listed in this report. This work was funded by the Universal Interoperability for Grid-Forming Inverters (UNIFI) Consortium. This generic model is developed to help the utility industry understand the concept of VSM GFMs. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment mature and improve, generic models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research Roadmap on Grid-Forming Inverters

This research roadmap is intended to fill the knowledge gap by providing a system view of grid-forming inverter-based resource controls and their impact on grid stability, which we believe is central to meeting some of the challenges to operating the future North American electric power system. This includes the roles and requirements of grid-forming inverter-based resources—including solar photovoltaics, wind generators, and energy storage. For this roadmap, we focus on a specific family of grid-forming inverter control approaches that do not rely on an external voltage source (i.e., no phase-locked loop) and that can share load without explicit communications. Although the roadmap is focused narrowly on system challenges for grid-forming controls and power system stability, including interactions with protection, we hope it serves as a foundational element for future system-of-systems roadmapping needed in a broader grid modernization effort with increasing deployments of inverter-based resources. The roadmap first introduces formal definitions for the grid stability topics and then describes the differences between grid-forming and traditional grid-following control approaches for inverter-based resources. The core of the roadmap consists of a review of current research and an outline of research needs related to five grid-forming inverter topics: frequency control, voltage control, system protection, fault ride-through and voltage recovery, and modeling and simulation. The review both delineates contemporary advances and highlights open research questions that must be addressed to enable the widespread adoption of inverter-based resources across the grid. Feedback from industry on these research questions is incorporated, including discussions during the Workshop on Grid-forming Inverters for Low-inertia Power Systems. The workshop included industry presentations and discussion of ongoing research, technology gaps, and piloting needs. This roadmap concludes by offering a multiyear perspective on the gradual field validation of grid-forming inverters. This perspective recognizes that the scale and scope of the types of power systems that inverters will be called on to provide grid-forming services will and should begin modestly. Specifically, this roadmap recognizes that inverter controls today are predominantly grid-following and that future power systems will involve a mix of inverter-based resources with both grid-following and grid-forming control capabilities. Growth over time will depend on how well grid-forming inverters perform and what advantages they bring as penetration levels (instantaneous and average) of inverter-based resources increases. This recognition, in turn, establishes a natural sequence of priorities for the research questions that must be addressed. Following this multiyear perspective, the roadmap offers short descriptions of two specific near-term research priorities: the review of regulatory and technical standards and the development of advanced modeling techniques. These priorities are foundational. We recommend immediate pursuit of them in parallel with and in direct support of the research outlined by our multiyear perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ecosystem-Level Biomimicry for the Built Environment: Adopting Systems Ecology Principles for the Control of Heterogeneous Energy Systems

This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.

biomimicry↗

A Distributed Intelligent Automated Demand Response Building Management System

The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-­based DR controller (dubbed the Central Load-­Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-­cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-­tune the strategies accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oscillatory Power Control and Consensus in Unbalanced Networks Using Grid Forming Inverters

In this paper, a state-space nonlinear control previously designed for balanced operation of grid-forming (GFM) inverters is extended to unbalanced operations. Unbalanced voltages and currents are analyzed, and their time-varying direct, quadrature, and zero components are parameterized in terms of six constant parameters. These parameters provide primary control design choices for not only an inverter’s terminal voltage but also its injections of both real and oscillatory power. It is shown that the proposed GFM control can precisely achieve a desired balanced terminal voltage under unbalanced loads. It is also shown that, by allowing the terminal voltage to be slightly unbalanced, oscillatory power can be adaptively minimized. Lastly, it is illustrated that oscillatory power can also be shared among multiple GFM inverters. Case studies and their simulations demonstrate that the proposed GFM control is effective in meeting the aforementioned objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

On the Low Risk of SSR in Type III Wind Turbines Operating with Grid-Forming Control

We have shown in previous work that the risk of subsynchronous resonance between wind power plants with Type III wind turbines and series-compensated transmission lines is low when the wind turbines are operated in grid-forming (GFM) mode instead of the standard grid-following mode. This paper explains the fundamental mechanism behind the improved damping characteristics by modeling the positive- and negative-sequence impedances of Type III wind turbines in GFM control mode. Here it is discovered that the GFM control naturally acts against the negative resistance behavior of Type III wind turbines at subsynchronous frequencies that results from an interaction between the rotor-side converter current controller and negative slip. The developed impedance models in the sequence domain and the improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the impedance response of a 2.5-MW Type III wind turbine in GFM mode.

17 WIND ENERGY↗

Evaluating Subgrid-Scale Properties of Low Clouds over the Beaufort Sea in Arctic System Reanalysis using ARISE Airborne In Situ Observations

Arctic low clouds influence the evolution of the Arctic system through their effects on radiative fluxes, boundary layer mixing, stability, turbulence, humidity, and precipitation. Unfortunately, atmospheric models and retrospective analysis (reanalysis) products struggle to accurately simulate the occurrence and properties of low clouds in the Arctic. To better understand the magnitude and possible causes of this problem, we analyze the disagreements between the Arctic System Reanalysis version 2 (ASR) and data taken during the September 2014 Arctic Radiation-IceBridge Sea and Ice Experiment (ARISE) airborne campaign conducted over the Beaufort Sea. Previous analysis of grid scale-averaged meteorological variables revealed a lack of cloud water produced in ASR, related to warm/dry biases, a failure to produce sufficient cloud water in conditions that are observed to be favorable for large cloud water values, and sampling issues with the ARISE flight paths. However, ARISE collected meteorological observations at one second intervals, offering spatial data resolution comparable to the subgrid scale of ASR. Subgrid scale properties and processes must be parameterized in conventional atmospheric models and reanalyses such as ASR, and often rely on assumed distributions of meteorological variables about the grid box mean state. To enable an examination of the realism of ASR’s subgrid scale properties, we use high resolution data from ARISE determine the “subgrid scale” distributions of cloud water and thermodynamic variables in the real atmosphere. Preliminary results show that the subgrid scale distribution of thermodynamic variables about the grid scale mean resembles the triangular distribution assumed in many bulk microphysical parameterization schemes, but also with tails resembling Gaussian distributions. The main goal is to understand the partitioning of the total available atmospheric water into water vapor and cloud water. Models typically covert some percentage of total water in a grid box to cloud water based on the estimated amount of supersaturation from the assumed vapor distribution. The ARISE measurements can reveal the relationship between subgrid scale supersaturation and the partition between cloud water and water vapor.

Jason Brant Dodson↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Paths to Sustainable Distributed Generation through 2050: Matching Local Waste Biomass Resources with Grid, Industrial, and Community Needs

This project identifies and evaluates current and future organic waste fuel types and matches these wastes with local grid, industrial, building power, and thermal energy needs. The team developed data on organic waste streams and thermal energy needs, and then constructed a techno-economic analysis model that can process the data and compute viable production of electricity, waste heat, biogas, and/or biomethane for a range of energy price points. Scenarios generated by the model include allocation of local organic waste streams to existing or new conversion infrastructure and are evaluated in a life-cycle assessment model to determine local and global environmental impacts. The project’s webbased tool provides rapid evaluation of potential waste-to-energy sites, including retrofits/expansions of existing facilities or entirely new construction, on the basis of resource availability, potential for waste heat use, and economic and environmental metrics.

09 BIOMASS FUELS↗

THE SL2S GALAXY-SCALE LENS SAMPLE. III. LENS MODELS, SURFACE PHOTOMETRY, AND STELLAR MASSES FOR THE FINAL SAMPLE

We present Hubble Space Telescope (HST) imaging data and Canada-France-Hawaii Telescope (CFHT) near-infrared ground-based images for the final sample of 56 candidate galaxy-scale lenses uncovered in the CFHT Legacy Survey as part of the Strong Lensing in the Legacy Survey project. The new images are used to perform lens modeling, measure surface photometry, and estimate stellar masses of the deflector early-type galaxies (ETGs). Lens modeling is performed on the HST images (or CFHT when HST is not available) by fitting the spatially extended light distribution of the lensed features assuming a singular isothermal ellipsoid mass profile and by reconstructing the intrinsic source light distribution on a pixelized grid. Based on the analysis of systematic uncertainties and comparison with inference based on different methods, we estimate that our Einstein radii are accurate to ∼3%. HST imaging provides a much higher success rate in confirming gravitational lenses and measuring their Einstein radii than CFHT imaging does. Lens modeling with ground-based images, however, when successful, yields Einstein radius measurements that are competitive with space-based images. Information from the lens models is used together with spectroscopic information from companion Paper IV to classify the systems, resulting in a final sample of 39 confirmed (grade A) lenses and 17 promising candidates (grade B,C). This represents an increase of half an order of magnitude in sample size with respect to the sample of confirmed lenses studied in Papers I and II. The Einstein radii of the confirmed lenses in our sample span the range 5-15 kpc and are typically larger than those of other surveys, probing the mass in regions where the dark matter contribution is more important. Stellar masses are in the range 10{sup 11}-10{sup 12} M{sub ☉}, covering the range of massive ETGs. The redshifts of the main deflector span a range 0.3 ≤ z{sub d} ≤ 0.8, which nicely complements low-redshift samples like the Sloan Lens ACS survey and thus provides an excellent sample for the study of the cosmic evolution of the mass distribution of ETGs over the second half of the history of the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Evolution of the Distributed Computing Model of the CMS experiment at the LHC

The Computing Model of the CMS experiment was prepared in 2005 and described in detail in the CMS Computing Technical Design Report. With the experience of the first years of LHC data taking and with the evolution of the available technologies, the CMS Collaboration identified areas where improvements were desirable. In this work we describe the most important modifications that have been, or are being implemented in the Distributed Computing Model of CMS. The Worldwide LHC computing Grid (WLCG) project acknowledged that the whole distributed computing infrastructure is impacted by this kind of changes that are happening in most LHC experiments and decided to create several Technical Evolution Groups (TEG) aiming at assessing the situation and at developing a strategy for the future. In this work we describe the CMS view on the TEG activities as well.

Grandi, C.↗

In Situ Inference for Earth System Predictability

An understanding of future evolution in precipitation extremes is critical to numerous DOE mission questions. Extreme events are by nature short time-scale events that are difficult to diagnose in available model data. Accurate modeling of extreme events necessarily requires high spatial resolution at the storm scale locally. However, the environment in which storms grow is dependent on global, remote, processes. These complex spatiotemporal relationships are impossible to diagnose at resolutions required to accurately model storms responsible for extreme precipitation. At exascale, climate simulations will produce results at fine enough resolution to investigate these relationships. However, the resulting data from these simulations will be far too large to save for post-simulation analysis. We advocate for fitting statistical models inside the simulations as they run, a context known as in situ, which will facilitate scientific investigations using the full fine-scale data stream. Figure 1 shows an example of the type of model we could consider, a Bayesian hierarchical spatial regression model. Precipitation extremes at each grid cell are modeled using extreme value distributions. Since extremes are rare, fitting models to individual grid cells can result in high variance and poor estimates. Instead, the model can be made more robust by smoothing the parameters of the extreme value model across space. Additionally, the parameters themselves can be functionally linked to other variables elsewhere in the simulation. Thus, we can use the fine-scale data to build more robust models for extremes that link extreme behavior to other climate patterns.

54 ENVIRONMENTAL SCIENCES↗

In Situ Inference for Earth System Predictability

Focal Area: Focal Area 3: Insight gleaned from complex simulated data using AI, big data analytics, and other advanced methods, including explainable AI and physics- or knowledge-guided AI. Science Challenge: An understanding of future evolution in precipitation extremes is critical to numerous DOE mission questions. Extreme events are by nature short time-scale events that are difficult to diagnose in available model data. Accurate modeling of extreme events necessarily requires high spatial resolution at the storm scale locally. However, the environment in which storms grow is dependent on global, remote, processes. These complex spatiotemporal relationships are impossible to diagnose at resolutions required to accurately model storms responsible for extreme precipitation. At exascale, climate simulations will produce results at fine enough resolution to investigate these relationships. However, the resulting data from these simulations will be far too large to save for post-simulation analysis. We advocate for fitting statistical models inside the simulations as they run, a context known as in situ, which will facilitate scientific investigations using the full fine-scale data stream. Figure 1 shows an example of the type of model we could consider, a Bayesian hierarchical spatial regression model. Precipitation extremes at each grid cell are modeled using extreme value distributions. Since extremes are rare, fitting models to individual grid cells can result in high variance and poor estimates. Instead, the model can be made more robust by smoothing the parameters of the extreme value model across space. Additionally, the parameters themselves can be functionally linked to other variables elsewhere in the simulation. Thus, we can use the fine-scale data to build more robust models for extremes that link extreme behavior to other climate patterns.

54 ENVIRONMENTAL SCIENCES↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗