SEARCH · Search NASA
Results for “Distribution grid”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Paths to Sustainable Distributed Generation through 2050: Matching Local Waste Biomass Resources with Grid, Industrial, and Community Needs
This project identifies and evaluates current and future organic waste fuel types and matches these wastes with local grid, industrial, building power, and thermal energy needs. The team developed data on organic waste streams and thermal energy needs, and then constructed a techno-economic analysis model that can process the data and compute viable production of electricity, waste heat, biogas, and/or biomethane for a range of energy price points. Scenarios generated by the model include allocation of local organic waste streams to existing or new conversion infrastructure and are evaluated in a life-cycle assessment model to determine local and global environmental impacts. The project’s webbased tool provides rapid evaluation of potential waste-to-energy sites, including retrofits/expansions of existing facilities or entirely new construction, on the basis of resource availability, potential for waste heat use, and economic and environmental metrics.
THE SL2S GALAXY-SCALE LENS SAMPLE. III. LENS MODELS, SURFACE PHOTOMETRY, AND STELLAR MASSES FOR THE FINAL SAMPLE
We present Hubble Space Telescope (HST) imaging data and Canada-France-Hawaii Telescope (CFHT) near-infrared ground-based images for the final sample of 56 candidate galaxy-scale lenses uncovered in the CFHT Legacy Survey as part of the Strong Lensing in the Legacy Survey project. The new images are used to perform lens modeling, measure surface photometry, and estimate stellar masses of the deflector early-type galaxies (ETGs). Lens modeling is performed on the HST images (or CFHT when HST is not available) by fitting the spatially extended light distribution of the lensed features assuming a singular isothermal ellipsoid mass profile and by reconstructing the intrinsic source light distribution on a pixelized grid. Based on the analysis of systematic uncertainties and comparison with inference based on different methods, we estimate that our Einstein radii are accurate to ∼3%. HST imaging provides a much higher success rate in confirming gravitational lenses and measuring their Einstein radii than CFHT imaging does. Lens modeling with ground-based images, however, when successful, yields Einstein radius measurements that are competitive with space-based images. Information from the lens models is used together with spectroscopic information from companion Paper IV to classify the systems, resulting in a final sample of 39 confirmed (grade A) lenses and 17 promising candidates (grade B,C). This represents an increase of half an order of magnitude in sample size with respect to the sample of confirmed lenses studied in Papers I and II. The Einstein radii of the confirmed lenses in our sample span the range 5-15 kpc and are typically larger than those of other surveys, probing the mass in regions where the dark matter contribution is more important. Stellar masses are in the range 10{sup 11}-10{sup 12} M{sub ☉}, covering the range of massive ETGs. The redshifts of the main deflector span a range 0.3 ≤ z{sub d} ≤ 0.8, which nicely complements low-redshift samples like the Sloan Lens ACS survey and thus provides an excellent sample for the study of the cosmic evolution of the mass distribution of ETGs over the second half of the history of the universe.
Evolution of the Distributed Computing Model of the CMS experiment at the LHC
The Computing Model of the CMS experiment was prepared in 2005 and described in detail in the CMS Computing Technical Design Report. With the experience of the first years of LHC data taking and with the evolution of the available technologies, the CMS Collaboration identified areas where improvements were desirable. In this work we describe the most important modifications that have been, or are being implemented in the Distributed Computing Model of CMS. The Worldwide LHC computing Grid (WLCG) project acknowledged that the whole distributed computing infrastructure is impacted by this kind of changes that are happening in most LHC experiments and decided to create several Technical Evolution Groups (TEG) aiming at assessing the situation and at developing a strategy for the future. In this work we describe the CMS view on the TEG activities as well.
In Situ Inference for Earth System Predictability
An understanding of future evolution in precipitation extremes is critical to numerous DOE mission questions. Extreme events are by nature short time-scale events that are difficult to diagnose in available model data. Accurate modeling of extreme events necessarily requires high spatial resolution at the storm scale locally. However, the environment in which storms grow is dependent on global, remote, processes. These complex spatiotemporal relationships are impossible to diagnose at resolutions required to accurately model storms responsible for extreme precipitation. At exascale, climate simulations will produce results at fine enough resolution to investigate these relationships. However, the resulting data from these simulations will be far too large to save for post-simulation analysis. We advocate for fitting statistical models inside the simulations as they run, a context known as in situ, which will facilitate scientific investigations using the full fine-scale data stream. Figure 1 shows an example of the type of model we could consider, a Bayesian hierarchical spatial regression model. Precipitation extremes at each grid cell are modeled using extreme value distributions. Since extremes are rare, fitting models to individual grid cells can result in high variance and poor estimates. Instead, the model can be made more robust by smoothing the parameters of the extreme value model across space. Additionally, the parameters themselves can be functionally linked to other variables elsewhere in the simulation. Thus, we can use the fine-scale data to build more robust models for extremes that link extreme behavior to other climate patterns.
In Situ Inference for Earth System Predictability
Focal Area: Focal Area 3: Insight gleaned from complex simulated data using AI, big data analytics, and other advanced methods, including explainable AI and physics- or knowledge-guided AI. Science Challenge: An understanding of future evolution in precipitation extremes is critical to numerous DOE mission questions. Extreme events are by nature short time-scale events that are difficult to diagnose in available model data. Accurate modeling of extreme events necessarily requires high spatial resolution at the storm scale locally. However, the environment in which storms grow is dependent on global, remote, processes. These complex spatiotemporal relationships are impossible to diagnose at resolutions required to accurately model storms responsible for extreme precipitation. At exascale, climate simulations will produce results at fine enough resolution to investigate these relationships. However, the resulting data from these simulations will be far too large to save for post-simulation analysis. We advocate for fitting statistical models inside the simulations as they run, a context known as in situ, which will facilitate scientific investigations using the full fine-scale data stream. Figure 1 shows an example of the type of model we could consider, a Bayesian hierarchical spatial regression model. Precipitation extremes at each grid cell are modeled using extreme value distributions. Since extremes are rare, fitting models to individual grid cells can result in high variance and poor estimates. Instead, the model can be made more robust by smoothing the parameters of the extreme value model across space. Additionally, the parameters themselves can be functionally linked to other variables elsewhere in the simulation. Thus, we can use the fine-scale data to build more robust models for extremes that link extreme behavior to other climate patterns.
Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources
The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.
Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System
During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.
Anomaly Detection for Power System Generation Control based on Hierarchical DBSCAN
The generation level of a generator in power grid is under control of multiple control loops such as governor action, Automatic Generation Control (AGC), and manual control. These control loops are vulnerable to cyber attacks and could become potential targets for the malicious adversary. In this paper, we investigated the detection of abnormal generation controls induced by cyber attacks. One data-driven anomaly detection methodology is presented based on the behavior conformity of generation units located in the same balancing authority. A semi-supervised clustering algorithm with Hierarchical Density based Spatial Clustering of Application with Noise (HDBSCAN) is proposed for the detection model training. In our previous work, we obtained a synthetic dataset that covers scenarios including normal operation, generation control under ramp attack, switching attack, AGC integrity attacks, etc. and it is used to evaluate the proposed clustering algorithm. Experimental results show that the proposed algorithm provides better detection accuracy than K-means clustering and can distinguish not only between normal and abnormal generation controls but also among various anomaly scenarios.
Interoperability Maturity Model
This document presents the relevant concepts for specifying criteria that support a grid modernization strategic vision for interoperability. It focuses on the ways to assess levels of interoperability. The assessment of interoperability needs to clearly show the relationship to interoperability and provide the necessary data to create a roadmap for how to improve interoperability. A key point to understand is that interoperability has several crucial elements, any of which may have areas for improvement. To measure interoperability, it is helpful to focus on specific areas based on the objectives of the stakeholders that are initiating the desired interoperability advancement. The measurement tool for interoperability allows the measurement tool and the area to which it is being applied to be segmented and applied in various ways. The measurement tool is based on, and developed from, the GridWise® Architecture Council’s (GWAC’s) Beta release of its Interoperability Maturity Model (GWAC 2011). As such, it represents an evolution of that approach, so the working name used in this document is IMM.
Understanding Impacts of Data Integrity Attacks on Transactive Control Systems
With the rapid growth of internet-connected smart devices capable of exchanging energy price information and adaptively controlling energy consumption of connected loads, the role of transactive control is expected to become more prominent in the modern grid. Transactive control systems integrate the wholesale and retail energy markets, and enable active participation of end users, thereby playing a key role in managing the rising number of distributed assets in the smart grid. The use of internet for the communication of data between the controllers at the building, distribution, and transmission levels makes the system susceptible to cyber-attacks. A skilled adversary can potentially manipulate the exchanged data with the intention of inflicting damage to the system. In this paper, four categories of metrics are put forth for evaluating the performance of the system when under data integrity attacks. A model for scaling-based data integrity attack has been described, and co-simulations have been performed on a 240 bus WECC transmission system model with detailed modeling of distribution systems at specific buses. Our results show that scaling-based data integrity attacks can have non-trivial impacts on the operational, financial, and comfort aspects of the transactive control system.
Security Evaluation of Two Intrusion Detection Systems in Smart Grid SCADA Environment
The increased complexity and interconnectivity of SCADA infrastructure in the power system have exposed it to the multitude of vulnerabilities. There is a growing emphasis towards developing an efficient intrusion detection system (IDS) to strengthen the security of the SCADA control system. This is a research-in-progress paper which presents the application of two anomaly-based intrusion detection systems (AIDS) in detecting the stealthy cyber-attack on the SCADA control system. We have applied the IDS tools Snort and Bro, in designing the IDS and later, compared their performances in terms of detection rate and latency in the alert packets with a motive of selecting better IDS for the SCADA security. Specifically, the timing-based rule is applied to identify the malicious packets based on the high temporal frequency in the network traffic. For the case study, we have implemented the SCADA based protection scheme which performs an autonomous protection to mitigate the system disturbances. We first implemented the stealthy cyber-attack which compromised the SCADA controller followed by data integrity attack on the system generator. Next, we perform the impact analysis during the attack followed by performance evaluation of IDS tools. Our experimental results show that the IDS tools are efficient in detecting cyber-attacks within an acceptable time frame for different sizes of network packets.
Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration
Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.
Transient Stability Study of IEEE 2800-2022 Standard Negative-Sequence-Current Compliant GFM IBRs
The primary function of grid-forming (GFM) inverter-based resources (IBRs) is to maintain voltage and fre- quency/phase angle stability; however, during unbalanced grid faults, IEEE Std. 2800-2022 requires IBRs to inject both positive- and negative-sequence reactive current. Enforcing compliance with this standard could compromise the stability of GFM IBRs under such fault conditions. This paper presents a preliminary transient stability study focused on the power angle stability of GFM IBRs operating in compliance with IEEE Std. 2800 during unbalanced faults. The goal is to assess potential stability issues associated with the standard's current injection requirements under fault ride-through conditions. The results show that injecting positive-sequence current with d-axis priority during unbalanced faults better preserves the power angle stability than the q-axis priority while still enabling negative-sequence current injection. These findings suggest that, to ensure stability, GFM IBRs might need to partially comply with IEEE Std. 2800 by prioritizing positive-sequence current injection along the d-axis.
A data-driven sensor placement approach for detecting voltage violations in distribution systems
Stochastic fluctuations in power injections from distributed energy resources (DERs) combined with load variability can cause constraint violations (e.g., exceeded voltage limits) in electric distribution systems. To monitor grid operations, sensors are placed to measure important quantities such as the voltage magnitudes. Here, in this paper, we consider a sensor placement problem which seeks to identify locations for installing sensors that can capture all possible violations of voltage magnitude limits. We formulate a bilevel optimization problem that minimizes the number of sensors and avoids false sensor alarms in the upper level while ensuring detection of any voltage violations in the lower level. This problem is challenging due to the nonlinearity of the power flow equations and the presence of binary variables. Accordingly, we employ recently developed conservative linear approximations of the power flow equations that overestimate or underestimate the voltage magnitudes. By replacing the nonlinear power flow equations with conservative linear approximations, we can ensure that the resulting sensor locations and thresholds are sufficient to identify any constraint violations. Additionally, we apply various problem reformulations to significantly improve computational tractability while simultaneously ensuring an appropriate placement of sensors. Lastly, we improve the quality of the results via an approximate gradient descent method that adjusts the sensor thresholds. We demonstrate the effectiveness of our proposed method for several test cases, including a system with multiple switching configurations.
Inverter Model Validation and Calibration Using Phasor Measurement Unit Data
As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.
Evaluation of Anomaly Detection for Wide-Area Protection Using Cyber Federation Testbed
Cyber physical security research for smart grid is currently one of the nation's top R&D priorities. The existing vulnerabilities in the legacy grid infrastructure make it particularly susceptible to countless cyber-attacks. There is a growing emphasis towards building interconnected, sophisticated federated testbeds to perform realistic experiments by allowing the integration of geographically-dispersed resources in the dynamic cyber-physical environment. In this paper, we present a cyber (network) based federation testbed to validate the performance of an anomaly detector in context of a Wide Area Protection (WAP) security. Specifically, we have utilized the resources available at the Iowa State University Power Cyber (ISU PCL) Laboratory to emulate the substation and local center networks; and the US Army Research Laboratory (ARL); to emulate the regional control center network. Initially, we describe a hardware-in-the loop based experimental setup for implementing data integrity attacks on an IEEE 39 bus system. We then perform network packet analysis focusing on latency and bandwidth as well as evaluate the performance of a decision tree based anomaly detector in measuring its ability to identify different attacks. Our experimental results reveal the computed wide area network latency; bandwidth requirement for minimum packet loss; and successful performance of the anomaly detector. Our studies also highlight the conceptual architecture necessary for developing the federated testbed, inspired by the NASPI network.
Grid Architecture Mapping to Understand Transformation (GAMUT): Methods and Framework Architecture
Grid architecture (GA) is a concept that was developed to address the need for a comprehensive view of power grid challenges. GA can be viewed as a relatively consistent and fixed high-level approach; however, for any instantiation of grid structures, a combinatorial explosion results from each lower-layer expansion. This constitutes the main challenge with GA—it is a grid architect’s view of the system, which might not be very informative at the implementation level. Grid Architecture Mapping to Understand Transformation (GAMUT project) seeks to bridge that gap by integrating subject matter expertise across GA structures, providing users who lack expertise in GA approaches with valuable insights and informational materials. GAMUT seeks to answer feasibility questions for the approach. System-level expectations are that a GA baseline needs to be established in order for GA to be the common framework to which any lower layer approach is tied. This report explores a potential information ingestion and documentation framework to support GAMUT. The main concepts that enable the solution domain of GAMUT are discussed, and examples are provided. The solution domain leverages already-existing technology and concepts related to GA, knowledge management, and other relevant areas. To assess GAMUT building blocks and the overall approach, a feasibility assessment is proposed, rooted in systems engineering and GA architecture evaluation concepts.