Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

The Mu2e experiment — Searching for charged lepton flavor violation

The Mu2e experiment will search for a Standard Model violating rate of neutrinoless conversion of a muon into an electron in the presence of an aluminum nucleus. Observation of this charged lepton flavor violating process would be an unambiguous sign of new physics. Mu2e will improve upon previous searches for this process by four orders of magnitude. This requires the world’s highest-intensity muon beam, a detector system capable of efficiently reconstructing the 105 MeV/c conversion electron signal, and minimizing sensitivity to background events. A pulsed 8 GeV proton beam strikes a target, producing pions that decay into muons. Beam outside the pulse must be suppressed to < 1 0 – 10 to reduce beam-related backgrounds. The muon beam is guided from the production target along the transport system and onto the aluminum stopping target. Conversion electrons leave the stopping target and propagate inside a solenoidal magnetic field to the tracker and electromagnetic calorimeter. The tracker is a system of straw tube panels filled with Ar/CO 2 at 1 atm that tracks particles inside of a solenoidal B-field and measures their momenta with ~ 100 keV/c resolution to resolve signal events from decay-in-orbit backgrounds. The CsI calorimeter provides E / p and is used to seed the track reconstruction algorithm with σ E / E ~ 10 % and σ t < 500 ps . Additionally, a novel cosmic ray veto with greater than 99.99% efficiency brings the expected number of background events to fewer than one over three years of running. Finally, to normalize the experiment, the stopping target monitor measures the rate of capture photons from muons incident on the stopping target by using a system of high-purity germanium and lanthanum bromide scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral characterization by CVD diamond detectors of energetic protons from high-repetition rate laser for aneutronic nuclear fusion experiments

This work describes the results of experiments performed at the femtosecond ECLIPSE laser facility at CELIA in Bordeaux. Targets constituted by aluminium foils of various thicknesses were irradiated with accelerated protons with energies in the range of interest for p+ 11 B nuclear fusion. Plasma formed in the laser-target interaction were detected using high temperature high radiation resistant diamonds. Time-of-flight measurements were performed by using Chemical Vapor Deposition (CVD) monocrystalline diamonds detectors, which are specifically designed to operate in harsh environments where large ElectroMagnetic Pulses (EMPs) are generated during laser-target interaction. The 1 Hz high repetition rate used for the ECLIPSE laser allowed the collection of a large number of similar shots, giving therefore a large statistics to accurately characterize the energy spectrum of the laser-plasma accelerated protons. As a result, the laser repetitivity at a relatively small intensity permits to improve the signal-to-noise ratio of the detection of the products of low cross-section reactions, such as the p+ 11 B one, by their collection over a large number of similar shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A source of high-power pulses of elliptically polarized ultrawideband radiation

Here, we describe a source of high-power ultrawideband radiation with elliptical polarization. The source consisting of a monopolar pulse generator, a bipolar pulse former, and a helical antenna placed into a radioparent container may be used in tests for electromagnetic compatibility. In the source, the helical antenna with the number of turns N = 4 is excited with a high-voltage bipolar pulse. Preliminary, we examined helical antennas at a low-voltage source aiming to select an optimal N and to estimate a radiation center position and boundary of a far-field zone. Finally, characteristics of the source in the operating mode at a pulse repetition rate of 100 Hz are presented in the paper as well. Energy efficiency of the antenna is 0.75 at the axial ratio equal to 1.3. The effective potential of radiation of the source at the voltage amplitudes of the bipolar pulse generator equal to -175/+200 kV reaches 280 kV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic resolution limits of monolithic organic scintillators for use in rep-rated proton imaging

Rep-rated diagnostics are a necessity for present and future laser facilities focused on the study of high-energy-density (HED) phenomena. Electromagnetic fields in HED systems are of particular interest to the community, but are inherently difficult to diagnose due to the high mass-densities involved. By utilizing high-energy protons that penetrate through dense plasmas, fields may be visualized by detecting variations in proton fluence caused by the Lorenz interaction of the protons with the field. Typical detecting media used for proton imaging are single-use and do not scale well to rep-rated operation. We propose the use of a scintillator-based detector and characterize the energy and spatial responses to demonstrate its feasibility as a viable option for rep-rated proton imaging and other diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel facility for 3D micro-irradiation of living cells in a controlled environment by MeV ions

We present a novel facility for micro-irradiation of living targets with ions from a 1.7 MV tandem accelerator. We show results using 1 MeV protons and 2 MeV He{sup 2+}. In contrast to common micro-irradiation facilities, which use electromagnetic or electrostatic focusing and specially designed vacuum windows, we employ a tapered glass capillary with a thin end window, made from polystyrene with a thickness of 1–2 μm, for ion focusing and extraction. The capillary is connected to a beamline tilted vertically by 45°, which allows for easy immersion of the extracted ions into liquid environment within a standard cell culture dish. An inverted microscope is used for simultaneously observing the samples as well as the capillary tip, while a stage-top incubator provides an appropriate environment for the samples. Furthermore, our setup allows to target volumes in cells within a μm{sup 3} resolution, while monitoring the target in real time during and after irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced infrared detectors using resonant structures combined with thin type-II superlattice absorbers

Here we examined the spectral responsivity of a 1.77μm thick type-II superlattice based long-wave infrared detector in combination with metallic nanoantennas. Coupling between the Fabry-Pérot cavity formed by the semiconductor layer and the resonant nanoantennas on its surface enables spectral selectivity, while also increasing peak quantum efficiency to over 50%. Electromagnetic simulations reveal that this high responsivity is a direct result of field-enhancement in the absorber layer, enabling significant absorption in spite of the absorber’s subwavelength thickness. Notably, thinning of the absorbing material could ultimately yield lower photodetector noise through a reduction in dark current while improving photocarrier collection efficiency. The temperature- and incident-angle-independent spectral response observed in these devices allows for operation over a wide range of temperatures and optical systems. This detector paradigm demonstrates potential benefits to device performance with applications throughout the infrared.

47 OTHER INSTRUMENTATION↗

X-ray microtomography shows pore structure and tortuosity in alkali-activated binders

Durability of alkali-activated binders is of vital importance in their commercial application, and depends strongly on microstructure and pore network characteristics. X-ray microtomography ({mu}CT) offers, for the first time, direct insight into microstructural and pore structure characteristics in three dimensions. Here, {mu}CT is performed on a set of sodium metasilicate-activated fly ash/slag blends, using a synchrotron beamline instrument. Segmentation of the samples into pore and solid regions is then conducted, and pore tortuosity is calculated by a random walker method. Segmented porosity and diffusion tortuosity are correlated, and vary as a function of slag content (slag addition reduces porosity and increases tortuosity), and sample age (extended curing gives lower porosity and higher tortuosity). This is particularly notable for samples with {>=} 50% slag content, where a space-filling calcium (alumino)silicate hydrate gel provides porosity reductions which are not observed for the sodium aluminosilicate ('geopolymer') gels which do not chemically bind water of hydration.

36 MATERIALS SCIENCE↗

Characterization of Avalanche Photodiodes (APDs) for the Electromagnetic Calorimeter in the ALICE Experiment

The Electromagnetic Calorimeter (EMCal) of the ALICE experiment at LHC will extensively make use of avalanche photodiodes (APDs) for the readout of scintillation light. The large sensitive area, high quantum efficiency and low dark current make this type of photosensors well-suited for the EMCal requirements. A testing activity is currently in progress in order to characterize the main properties of these APDs and find the best working conditions. Fundamental tasks are the individual test of all APDs after presetting their nominal gain via the bias control and the study of APD gain coefficients as a function of the applied bias voltage and temperature. An overview of the adopted procedure will be presented, together with a description of preliminary results obtained on a first sample of APDs during the testing activity.

43 PARTICLE ACCELERATORS↗

An ultra-high-energy-neutrino detector using rock salt and ice as detection media for radar method

We had found radio-wave-reflection effect in rock salt for detection of an ultra-high energy neutrino (UHE{nu}) which is generated in GZK processes in the universe. When an UHE{nu} interacts with rock salt or ice as a detection medium, the energy converts to a thermal energy. Consequently, a temperature gives rise along an UHE{nu} shower at the interaction location. The permittivity arises with respect to the temperature at ionization processes of the UHE{nu} shower which is composed of hadronic and electromagnetic multiplication processes. The irregularity of the refractive index in the medium for radio wave rises to a reflection. The reflection effect with a long attenuation length of radio wave in rock salt and ice would yield a new method to detect UHE{nu}. They could be used for detection media in which the UHE{nu} interacts with. We could find a huge amount of rock salt or ice over 50 Gt in a natural rock salt formation or Antarctic ice sheet. Radio wave transmitted into the medium generated by a radar system could be reflected by the irregularity of the refractive index at the shower. Receiving the reflected radio wave yields information about the UHE{nu}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GOING THE DISTANCE: MAPPING HOST GALAXIES OF LIGO AND VIRGO SOURCES IN THREE DIMENSIONS USING LOCAL COSMOGRAPHY AND TARGETED FOLLOW-UP

The Advanced Laser Interferometer Gravitational-wave Observatory (LIGO) discovered gravitational waves (GWs) from a binary black hole merger in 2015 September and may soon observe signals from neutron star mergers. There is considerable interest in searching for their faint and rapidly fading electromagnetic (EM) counterparts, though GW position uncertainties are as coarse as hundreds of square degrees. Because LIGO’s sensitivity to binary neutron stars is limited to the local universe, the area on the sky that must be searched could be reduced by weighting positions by mass, luminosity, or star formation in nearby galaxies. Since GW observations provide information about luminosity distance, combining the reconstructed volume with positions and redshifts of galaxies could reduce the area even more dramatically. A key missing ingredient has been a rapid GW parameter estimation algorithm that reconstructs the full distribution of sky location and distance. We demonstrate the first such algorithm, which takes under a minute, fast enough to enable immediate EM follow-up. By combining the three-dimensional posterior with a galaxy catalog, we can reduce the number of galaxies that could conceivably host the event by a factor of 1.4, the total exposure time for the Swift X-ray Telescope by a factor of 2, the total exposure time for a synoptic optical survey by a factor of 2, and the total exposure time for a narrow-field optical telescope by a factor of 3. This encourages us to suggest a new role for small field of view optical instruments in performing targeted searches of the most massive galaxies within the reconstructed volumes.

79 ASTRONOMY AND ASTROPHYSICS↗

Diffractive pion production at COMPASS - First results on 3{pi} final states - neutral mode

The COMPASS experiment at CERN is designed for light hadron spectroscopy with emphasis on the detection of new states, in particular the search for exotic states and glue-balls. After a short pilot run in 2004 (190 GeV/c negative pion beam, lead target) showing significant production strength for an exotic J{sup PC} = 1{sup -+} state at 1.66 GeV/c{sup 2}, we have collected data with a 190 GeV/c negative charged hadron beam on a proton (liquid hydrogen) and nuclear targets in 2008 and 2009. The spectrometer features good coverage by electromagnetic calorimetry, and our data provide excellent opportunity for simultaneous observation of new states in two different decay modes in the same experiment. The diffractively produced (3{pi}){sup -} system for example can be studied in both modes {pi}{sup -}p{yields}{pi}{sup -{pi}+{pi}-}p and {pi}{sup -}p{yields}{pi}{sup -{pi}0{pi}0}p. Charged and neutral mode rely on completely different parts of the spectrometer. Observing a new state in both modes provides important crosscheck. First results of a preliminary PWA performed on the 2008 data are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transmission of broad W/Rh and W/Al (target/filter) x-ray beams operated at 25-49 kVp through common shielding materials

Purpose: To provide transmission data for broad 25-39 kVp (kilovolt peak) W/Rh and 25-49 kVp W/Al (target/filter, W-tungsten, Rh-rhodium, and Al-aluminum) x-ray beams through common shielding materials, such as lead, concrete, gypsum wallboard, wood, steel, and plate glass. Methods: The unfiltered W-target x-ray spectra measured on a Selenia Dimensions system (Hologic Inc., Bedford, MA) set at 20-49 kVp were, respectively, filtered using 50-{mu}m Rh and 700-{mu}m Al, and were subsequently used for Monte Carlo calculations. The transmission of broad x-ray beams through shielding materials was simulated using Geant4 low energy electromagnetic physics package with photon- and electron-processes above 250 eV, including photoelectric effect, Compton scattering, and Rayleigh scattering. The calculated transmission data were fitted using Archer equation with a robust fitting algorithm. Results: The transmission of broad x-ray beams through the above-mentioned shielding materials was calculated down to about 10{sup -5} for 25-39 kVp W/Rh and 25-49 kVp W/Al. The fitted results of {alpha}, {beta}, and {gamma} in Archer equation were provided. The {alpha} values of kVp Greater-Than-Or-Slanted-Equal-To 40 were approximately consistent with those of NCRP Report No. 147. Conclusions: These data provide inputs for the shielding designs of x-ray imaging facilities with W-anode x-ray beams, such as from Selenia Dimensions.

36 MATERIALS SCIENCE↗

Photon Reconstruction and Identification with the ATLAS detector

The understanding of the photons reconstruction will be one of the key issues at the start-up of data-taking with the ATLAS experiment at the LHC. Large statistics samples of photons produced in association with jets are expected over a wide range of E{sub T}.The photon reconstruction is based on an electromagnetic-cluster-seeded algorithm which classifies as photons those clusters which have no matching prompt track. These are then subdivided into converted or non-converted photon candidates depending on the presence of one or more tracker-reconstructed electron-positron pairs pointing to it. The precise knowledge of the material upstream the calorimeter and a correct treatment of the converted photons are critical for a correct photon reconstruction and identification.The photon identification is based almost entirely on the analysis of the shower shapes in the calorimeter. The goal is to achieve an efficient photon selection in the range from 20 GeV to several hundreds GeV with a rejection of 10{sup 3}-10{sup 4} against QCD jets in the moderate transverse momentum region of 20 to 100 GeV, which is the relevant one for H->gammagamma searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IMPACT OF THE 1/f NOISE AND THE ASYMMETRIC BEAM ON NON-GAUSSIANITY SEARCHES WITH PLANCK

We study the impact of correlated instrumental noise and non-circular antenna beam patterns on primordial non-Gaussianity analysis. The two systematic effects are reproduced in the case of the Planck mission, using Planck-like realistic simulations. The non-Gaussian analysis is conducted with different approaches. First we adopt a blind approach, using the Spherical Mexican Hat Wavelet and the Minkowski functionals, and then an f {sub NL} estimator. We look respectively for false primordial non-Gaussian detections and for bias or variance increase in the estimated f {sub NL} value. Even if some slight effects are present, we cannot observe any significant impact of the 1/f noise and the asymmetric beam on non-Gaussianity searches in the context of the Planck mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Test beam results of micro channel plates in 'ionisation mode' for the detection of single charged particle and electromagnetic showers

IMCP is an R and D project aimed at the exploitation of secondary emission of electrons from the surface of microchannel plates (MCP) for fast timing of showers in high rate environments. The usage of MCPs in 'ionisation' mode has long been proposed and is used extensively in ion time-of-flight mass spectrometers. What has not been investigated in depth is their use to detect the ionizing component of showers. The fast time resolution of MCPs exceeds anything that has been previously used in calorimeters, and, if exploited effectively, could aid in the event reconstruction at high luminosities. Results from tests with electrons with energies up to 150 GeV of MCP devices with different characteristics will be presented, in particular detection efficiency and time resolution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MARTA: a high-energy cosmic-ray detector concept for high-accuracy muon measurement

A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. Here, the combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive mode control in the recirculating planar magnetron

Preliminary experiments of the recirculating planar magnetron microwave source have demonstrated that the device oscillates but is susceptible to intense mode competition due, in part, to poor coupling of RF fields between the two planar oscillators. A novel method of improving the cross-oscillator coupling has been simulated in the periodically slotted mode control cathode (MCC). The MCC, as opposed to a solid conductor, is designed to electromagnetically couple both planar oscillators by allowing for the propagation of RF fields and electrons through resonantly tuned gaps in the cathode. Using the MCC, a 12-cavity anode block with a simulated 1 GHz and 0.26 c phase velocity (where c is the speed of light) was able to achieve in-phase oscillations between the two sides of the device in as little as 30 ns. An analytic study of the modified resonant structure predicts the MCC's ability to direct the RF fields to provide tunable mode separation in the recirculating planar magnetron. The self-consistent solution is presented for both the degenerate even (in phase) and odd (180 Degree-Sign out of phase) modes that exist due to the twofold symmetry of the planar magnetrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗