Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

CORRELATION OF SUPERNOVA REMNANT MASERS AND GAMMA-RAY SOURCES

Supernova remnants (SNRs) interacting with molecular clouds are potentially exciting systems in which to detect evidence of cosmic ray acceleration. Prominent gamma-ray emission is produced via the decay of neutral pions when cosmic rays encounter nearby dense clouds. In many of the SNRs coincident with gamma-ray sources, the presence of OH (1720 MHz) masers is used to identify interaction with dense gas and to provide a kinematic distance to the system. In this Letter we use statistical tests to demonstrate that there is a correlation between these masers and a class of GeV- to TeV-energy gamma-ray sources coincident with interacting remnants. For pion decay the gamma-ray luminosity provides a direct estimate of the local cosmic ray density. We find the cosmic ray density is enhanced by one to two orders of magnitude over the local solar value, comparable to X-ray-induced ionization in these remnants. The inferred ionization rates are sufficient to explain non-equilibrium chemistry in the post-shock gas, where high columns of hydroxyl are observed.

79 ASTRONOMY AND ASTROPHYSICS↗

FIRST-YEAR SLOAN DIGITAL SKY SURVEY-II (SDSS-II) SUPERNOVA RESULTS: CONSTRAINTS ON NONSTANDARD COSMOLOGICAL MODELS

We use the new Type Ia supernovae discovered by the Sloan Digital Sky Survey-II supernova survey, together with additional supernova data sets as well as observations of the cosmic microwave background and baryon acoustic oscillations to constrain cosmological models. This complements the standard cosmology analysis presented by Kessler et al. in that we discuss and rank a number of the most popular nonstandard cosmology scenarios. When this combined data set is analyzed using the MLCS2k2 light-curve fitter, we find that more exotic models for cosmic acceleration provide a better fit to the data than the LAMBDACDM model. For example, the flat Dvali-Gabadadze-Porrati model is ranked higher by our information-criteria (IC) tests than the standard model with a flat universe and a cosmological constant. When the supernova data set is instead analyzed using the SALT-II light-curve fitter, the standard cosmological-constant model fares best. This investigation of how sensitive cosmological model selection is to assumptions about, and within, the light-curve fitters thereby highlights the need for an improved understanding of these unresolved systematic effects. Our investigation also includes inhomogeneous LemaItre-Tolman-Bondi (LTB) models. While our LTB models can be made to fit the supernova data as well as any other model, the extra parameters they require are not supported by our IC analysis. Finally, we explore more model-independent ways to investigate the cosmic expansion based on this new data set.

79 ASTRONOMY AND ASTROPHYSICS↗

K-shell internal conversion coefficient for M4 decay of the 30.8 keV isomer in 93 Nb

The 30.8 keV (1/2) – isomeric state in $^{93}_{41}$Nb decays by an M4 transition to the (9/2) + ground state. Here, we have measured the K-shell internal conversion coefficient α K for this transition in order to test the validity of current methods of calculation for a case with relatively low atomic number, low transition energy, and a high value of α K . Taking the fluorescence yield of niobium to be 0.751(4), we obtain α K = 2.56(9) × 10 4 , a result that agrees with the Dirac-Fock calculations that take into account the presence of a K vacancy in the final state, and disagrees by 1.7 standard deviations with calculations that ignore the vacancy. We also determine the energy of the isomeric state to be 30.760(5) keV, a fourfold improvement in precision over the currently accepted value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray phase-contrast imaging with an Inverse Compton Scattering source

Single-shot in-line phase-contrast imaging with the Inverse Compton Scattering X-ray source available at ATF (Accelerator Test Facility) at Brookhaven National Laboratory is experimentally demonstrated. Phase-contrast images of polymer wires are obtained with a single X-ray pulse whose time length is about 1 picosecond. The edge-enhancement effect is clearly visible in the images and simulations show a quantitative agreement with experimental data. A phase-retrieval step in the image processing leads to a accurate estimation of the projected thickness of our samples. Finally, a single-shot image of a wasp is presented as an example of a biological sample.

07 ISOTOPE AND RADIATION SOURCES↗

DISSIPATION WAVENUMBERS FOR TURBULENCE IN ELECTRON-POSITRON PLASMAS

Many astrophysical systems involve turbulent electron-positron plasmas. Linear kinetic theory of electromagnetic fluctuations in homogeneous, magnetized, collisionless, non-relativistic electron-positron plasmas predicts that two lightly damped modes propagate at relatively long wavelengths: an Alfven-like mode with dispersion {omega}{sub r}=k{sub ||}v-tilde{sub A} and a magnetosonic-like mode with dispersion {omega}{sub r}{approx_equal}kv-tilde{sub A} if {beta} {sub e} << 1. Here, v-tilde{sub A} is the Alfven speed in an electron-positron plasma and || refers to the direction parallel to the background magnetic field B{sub o}. The dissipation wavenumber k{sub d} is defined as the value of k at which the damping rate equals the rate of energy transfer by the turbulent cascade. Using linear theory and a basic turbulent cascade model, k{sub d} is predicted for turbulence at propagation quasi parallel to B{sub o}, for quasi-perpendicular magnetosonic-like turbulence, and for quasi-perpendicular Alfven-like turbulence. In the latter case, the model predicts that an increase in the turbulent energy should correspond to an increase in k{sub d} . The assumptions and predictions of the model may be tested by particle-in-cell simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive linear predictor FIR filter based on the Cyclone V FPGA with HPS to reduce narrow band RFI in AERA radio detection of cosmic rays

We present the new approach to a filtering of radio frequency interferences (RFI) in the Auger Engineering Radio Array (AERA) which study the electromagnetic part of the Extensive Air Showers. The radio stations can observe radio signals caused by coherent emissions due to geomagnetic radiation and charge excess processes. AERA observes frequency band from 30 to 80 MHz. This range is highly contaminated by human-made RFI. In order to improve the signal to noise ratio RFI filters are used in AERA to suppress this contamination. The first kind of filter used by AERA was the Median one, based on the Fast Fourier Transform (FFT) technique. The second one, which is currently in use, is the infinite impulse response (IIR) notch filter. The proposed new filter is a finite impulse response (FIR) filter based on a linear prediction (LP). A periodic contamination hidden in a registered signal (digitized in the ADC) can be extracted and next subtracted to make signal cleaner. The FIR filter requires a calculation of n=32, 64 or even 128 coefficients (dependent on a required speed or accuracy) by solving of n linear equations with coefficients built from the covariance Toeplitz matrix. This matrix can be solved by the Levinson recursion, which is much faster than the Gauss procedure. The filter has been already tested in the real AERA radio stations on Argentinean pampas with a very successful results. The linear equations were solved either in the virtual soft-core NIOSR processor (implemented in the FPGA chip as a net of logic elements) or in the external Voipac PXA270M ARM processor. The NIOS processor is relatively slow (50 MHz internal clock), calculations performed in an external processor consume a significant amount of time for data exchange between the FPGA and the processor. Test showed a very good efficiency of the RFI suppression for stationary (long-term) contaminations. However, we observed a short-time contaminations, which could not be suppressed either by the IIR-notch filter or by the FIR filter based on the linear predictions. For the LP FIR filter the refreshment time of the filter coefficients was to long and filter did not keep up with the changes of a contamination structure, mainly due to a long calculation time in a slow processors. We propose to use the Cyclone V SE chip with embedded micro-controller operating with 925 MHz internal clock to significantly reduce a refreshment time of the FIR coefficients. The lab results are promising. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Breakup of the aligned H{sub 2} molecule by xuv laser pulses: A time-dependent treatment in prolate spheroidal coordinates

We have carried out calculations of the triple-differential cross section for one-photon double ionization of molecular hydrogen for a central photon energy of 75 eV, using a fully ab initio, nonperturbative approach to solve the time-dependent Schroedinger equation in prolate spheroidal coordinates. The spatial coordinates {xi} and {eta} are discretized in a finite-element discrete-variable representation. The wave packet of the laser-driven two-electron system is propagated in time through an effective short iterative Lanczos method to simulate the double ionization of the hydrogen molecule. For both symmetric and asymmetric energy sharing, the present results agree to a satisfactory level with most earlier predictions for the absolute magnitude and the shape of the angular distributions. A notable exception, however, concerns the predictions of the recent time-independent calculations based on the exterior complex scaling method in prolate spheroidal coordinates [L. Tao et al., Phys. Rev. A 82, 023423 (2010)]. Extensive tests of the numerical implementation were performed, including the effect of truncating the Neumann expansion for the dielectronic interaction on the description of the initial bound state and the predicted cross sections. We observe that the dominant escape mode of the two photoelectrons depends dramatically on the energy sharing. In the parallel geometry, when the ejected electrons are collected along the direction of the laser polarization axis, back-to-back escape is the dominant channel for strongly asymmetric energy sharing, while it is completely forbidden if the two electrons share the excess energy equally.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spin Sum Rules and Polarizabilities

The Gerasimov-Drell-Hearn sum rule and related dispersive integrals connect real and virtual Compton scattering to inclusive photo- and electroproduction. Being based on universal principles as causality, unitarity, and gauge invariance, these relations provide a unique testing ground to study the internal degrees of freedom that hold a system together. The present contribution reviews the spin-dependent sum rules and cross sections of the nucleon. At small momentum transfer, the data sample information on the long range phenomena (Goldstone bosons and collective resonances), whereas the primary degrees of freedom (quarks and gluons) become visible at large momentum transfer (short distance). The rich body of new data covers a wide range of phenomena from coherent to incoherent processes, and from the generalized spin polarizabilities on the low-energy side to higher twist effects in deep inelastic scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of X-ray Beam Position Monitors for Superconducting Wiggler

For the development of an X-ray beam position monitor (XBPM) for the superconducting wiggler (SW) at the NSRRC, two XBPM are installed in the SW front end. The blades of the XBPM were manufactured with material of three types; tungsten, Glidcop and aluminium, to test the effect of the material on the performance of the XBPM. These three materials are compared with blades of molybdenum that were previously installed. The vibration and thermal expansion of the pillar of a XBPM affects the position reading of the XBPM. For pillars of XBPM of various designs, each type has a distinct thermal isolating material and is filled with a separate damping material for comparison. The design requirements of these XBPM include high spatial resolution of the monitor and mechanical stability of the structure with a large thermal load. The design, fabrication and measurement results are presented here.

43 PARTICLE ACCELERATORS↗

Photofission of Actinides with Linearly Polarized Photons

Idaho State University and the Idaho Accelerator Center are developing a polarized photon facility in the 10 MeV region using the off axis bremsstrahlung technique. Initial tests have been performed with the aim of using the high analyzing power of the photodisintegration of the deuteron to measure the beam polarization. A program is currently underway to measure the potential angular asymmetries of neutrons arising from the angular distribution of the fission fragments from photofission with linearly polarized photons. In this paper, we describe the Idaho State University Polarized Photon Facility, present results of commissioning runs, and describe potential application of polarized photofission in detecting actinides for homeland security and safeguards applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parasitic signals in the receiving band of the Sub-Harmonic Arc Detection system on JET ICRF Antennas

When testing the SHAD system on JET ICRF antennas, parasitic signals in the detection band (5-20MHz) were detected. We have identified emission from grid breakdown events in the Neutral Beam injectors, and Ion Cyclotron Emission from the plasma. Spurious signals in the band 4-10 MHz are also often observed at the onset of ELM events. Such parasitic signals could complicate the design and operation of SHAD in ICRF systems for fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-AB-202-05: BEST IN PHYSICS (JOINT IMAGING-THERAPY): First Online Ultrasound-Guided MLC Tracking for Real-Time Motion Compensation in Radiotherapy

Purpose: While MLC tracking has been successfully used for motion compensation of moving targets, current real-time target localization methods rely on correlation models with x-ray imaging or implanted electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging yields volumetric data in real-time (4D) without ionizing radiation. We report the first results of online 4D ultrasound-guided MLC tracking in a phantom. Methods: A real-time tracking framework was installed on a 4D ultrasound station (Vivid7 dimension, GE) and used to detect a 2mm spherical lead marker inside a water tank. The volumetric frame rate was 21.3Hz (47ms). The marker was rigidly attached to a motion stage programmed to reproduce nine tumor trajectories (five prostate, four lung). The 3D marker position from ultrasound was used for real-time MLC aperture adaption. The tracking system latency was measured and compensated by prediction for lung trajectories. To measure geometric accuracy, anterior and lateral conformal fields with 10cm circular aperture were delivered for each trajectory. The tracking error was measured as the difference between marker position and MLC aperture in continuous portal imaging. For dosimetric evaluation, 358° VMAT fields were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using a 3%/3 mm γ-test. Results: The tracking system latency was 170ms. The mean root-mean-square tracking error was 1.01mm (0.75mm prostate, 1.33mm lung). Tracking reduced the mean γ-failure rate from 13.9% to 4.6% for prostate and from 21.8% to 0.6% for lung with high-modulation VMAT plans and from 5% (prostate) and 18% (lung) to 0% with low modulation. Conclusion: Real-time ultrasound tracking was successfully integrated with MLC tracking for the first time and showed similar accuracy and latency as other methods while holding the potential to measure target motion non-invasively. SI was supported by the Graduate School for Computing in Medicine and Life Science, German Excellence Initiative [grant DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

ON THE GeV AND TeV DETECTIONS OF THE STARBURST GALAXIES M82 AND NGC 253

The GeV and TeV emission from M82 and NGC 253 observed by Fermi, HESS, and VERITAS constrain the physics of cosmic rays (CRs) in these dense starbursts. We argue that the {gamma}-rays are predominantly hadronic in origin, as expected by previous studies. The measured fluxes imply that pionic losses are efficient for CR protons in both galaxies: we show that a fraction F{sub cal} {approx} 0.2-0.4 of the energy injected in high-energy primary CR protons is lost to inelastic proton-proton collisions (pion production) before escape, producing {gamma}-rays, neutrinos, and secondary electrons and positrons. We discuss the factor of {approx}2 uncertainties in this estimate, including supernova rate and leptonic contributions to the GeV-TeV emission. We argue that {gamma}-ray data on ULIRGs like Arp 220 can test whether M82 and NGC 253 are truly calorimetric, and we present upper limits on Arp 220 from the Fermi data. We show that the observed ratio of the GeV to GHz fluxes of the starbursts suggests that non-synchrotron cooling processes are important for cooling the CR electron/positron population. We briefly reconsider previous predictions in light of the {gamma}-ray detections, including the starburst contribution to the {gamma}-ray background and CR energy densities. Finally, as a guide for future studies, we list the brightest star-forming galaxies on the sky and present updated predictions for their {gamma}-ray and neutrino fluxes.

79 ASTRONOMY AND ASTROPHYSICS↗

Formulation and numerical analysis of a fully-coupled dynamically deforming electromagnetic wire

Here, an electromagnetic beam model is developed for the simulation of actuated electronic textiles. The beam is solved using a nonlinear director-based kinematic description with additional temperature and electric potential fields along its length. The three fields are fully coupled by mutual dependences on the deformation, Lorenz force, back electromotive force, temperature dependent constitutive responses, and the Seebeck effect. Instead of solving Maxwell's equations in full detail, a quasistatic approximation is used to solve the electric potential in the presence of a moving material medium. The current-carrying beam approximation is used to further simplify the solution space for the potential. While this formulation alleviates the spatial and temporal discretization restrictions, the coupled problem is an index-1 semi-explicit Differential Algebraic Equation requiring special treatment. The time dependent problem is solved using different Runge-Kutta methods. Diagonally implicit Runge-Kutta methods and explicit Runge-Kutta methods using implicit solution of the electric potential problem are explored. The finite element model is implemented using the open source package FEniCS, which is able to automatically generate the linearizations of the multiphysics equations required for the implicit solutions. A model problem is constructed with which to test and analyze the physical formulation and numerical solution techniques. The time stepping methods are verified using the convergence orders of the higher-order Runge-Kutta methods. Runtime comparisons show that the explicit methods are generally more computationally efficient than the implicit schemes used for this problem. For the implicit schemes, a staggered solution is significantly faster than a monolithic solution at most time step sizes. However, at very large time steps, such as those that would be used for dynamic relaxation, the monolithic solution can be more efficient than the staggered solution.

36 MATERIALS SCIENCE↗

A deterministic solution of the first order linear Boltzmann transport equation in the presence of external magnetic fields

Purpose: Accurate radiotherapy dose calculation algorithms are essential to any successful radiotherapy program, considering the high level of dose conformity and modulation in many of today’s treatment plans. As technology continues to progress, such as is the case with novel MRI-guided radiotherapy systems, the necessity for dose calculation algorithms to accurately predict delivered dose in increasingly challenging scenarios is vital. To this end, a novel deterministic solution has been developed to the first order linear Boltzmann transport equation which accurately calculates x-ray based radiotherapy doses in the presence of magnetic fields. Methods: The deterministic formalism discussed here with the inclusion of magnetic fields is outlined mathematically using a discrete ordinates angular discretization in an attempt to leverage existing deterministic codes. It is compared against the EGSnrc Monte Carlo code, utilizing the emf-macros addition which calculates the effects of electromagnetic fields. This comparison is performed in an inhomogeneous phantom that was designed to present a challenging calculation for deterministic calculations in 0, 0.6, and 3 T magnetic fields oriented parallel and perpendicular to the radiation beam. The accuracy of the formalism discussed here against Monte Carlo was evaluated with a gamma comparison using a standard 2%/2 mm and a more stringent 1%/1 mm criterion for a standard reference 10 × 10 cm{sup 2} field as well as a smaller 2 × 2 cm{sup 2} field. Results: Greater than 99.8% (94.8%) of all points analyzed passed a 2%/2 mm (1%/1 mm) gamma criterion for all magnetic field strengths and orientations investigated. All dosimetric changes resulting from the inclusion of magnetic fields were accurately calculated using the deterministic formalism. However, despite the algorithm’s high degree of accuracy, it is noticed that this formalism was not unconditionally stable using a discrete ordinate angular discretization. Conclusions: The feasibility of including magnetic field effects in a deterministic solution to the first order linear Boltzmann transport equation is shown. The results show a high degree of accuracy when compared against Monte Carlo calculations in all magnetic field strengths and orientations tested.

60 APPLIED LIFE SCIENCES↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Study of keV radiation properties of Mo and Ti X-pinch plasma sources using a pinhole transmission grating spectrometer

The properties of keV x-ray radiations from Mo and Ti X-pinch plasma sources at the current of 800 kA were investigated by a pinhole transmission grating spectrometer. The spectrometer was characterized by a high linear dispersion rate (2.9 A/mm), and from its time-integrated diffraction images, rich information about the X-pinch sources (e.g., source number, source size, and absolute spectra) could be obtained. Multiple hot spots were produced in all the Mo tests with loads made of two or four 25 mum wires with or without a shunt wire, and obvious increases both in the radiation intensity and in the source size around the spectral region of 2.6 keV were observed. In Ti X-pinch tests, a single keV x-ray burst with a source size of approx200 mum and a time duration of approx200 ps in full width at half maximum was obtained using a load made of two 50 mum wires plus a shunt wire. The intensity of x-rays decreased sharply from approx10{sup 11} photon eV{sup -1} sr{sup -1} at 1 keV to approx10{sup 8} photon eV{sup -1} sr{sup -1} at 4 keV. The energy-dependent source size in the band of 1-4 keV is less than 100 mum and seemed to shrink quickly as x-ray energy increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗