Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Liquid Metal Propellant Feed System for Plasma Propulsion

High-power plasma thrusters that utilize molten metallic propellants (e.g., the Lithium Lorentz Force Accelerator) are currently being investigated as a primary propulsion option for in-space nuclear-electric systems. A critical component of the thruster is the propellant feed system, which must reliably and accurately pump liquid metal into the thruster discharge chamber. We present design details and calibration results for a compact liquid metal propellant feed system that contains no moving parts, for use in laboratory testing of plasma thrusters. Feed line pressure is maintained using an MHD flow coupler, and the flow rate is monitored using a simple voltage divider, which is submerged in the propellant reservoir. Results for lithium and gallium propellants show capability to meter propellant at flow rates up to 10 +/- 0.1 mg/s.

Markusic, T. E.↗

Scenarios of Nuclear Energy Use in the United States for the 21st Century

The uncertainty in the cost of nuclear energy coinciding with efforts to address climate change are contributing to the uncertainty in the future role of nuclear energy in the US electricity system and the response to addressing global climate change. Sensitivity cases of alternative nuclear capital costs, ranging from 2600 to 6600 $\$ $/kW, were investigated with scenarios of alternative carbon mitigation policies, including 50, 100, and 150 $\$ $/tCO 2 carbon tax cases and economy-wide net-zero goals by 2050, 2060, and 2070 for the US. The resulting US nuclear power capacity ranged from 130 to 240 GW in 2050 and 90 to 450 GW in 2100 from nuclear cost sensitivity cases without carbon mitigation policies. Imposing policies to achieve the decarbonization of electricity and net-zero emission goals increased the range of nuclear power capacity from 190 to 460 GW in 2050 and 210 to 850 GW by 2100, where the range is from the low and high nuclear cost cases. Carbon penalties beyond 100 $\$ $/tCO 2 had a diminishing role on the expansion of nuclear power as the electricity sector becomes fully decarbonized. The 50 $\$ $/tCO 2 tax had the nuclear capital cost equivalency of 1000 $\$ $/kW reduction, while the 100 $\$ $/tCO 2 tax had the equivalency of 2000 $\$ $/kW reduction. Net-zero goals increased the contribution of nuclear power due to the increase in total electricity demand, but the delay in the timing of net-zero did not significantly affect the role of nuclear in the long-term. All net-zero goals were similar in their energy system impact with resulting carbon tax levels reaching 300 $\$ $/tCO 2 . Electricity is fully decarbonized in the net-zero scenarios and carbon pricing beyond 100 to 150 $\$ $/tCO 2 had little influence on the additional deployment of nuclear power. Regardless of the carbon policy, however, nuclear capital cost reductions had a clear and pronounced impact on the expanded deployment of nuclear power under all scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗

Opportunities for Industry to Provide Flexibility While Increasing Profitability

Supply and demand flexibility will both be needed to ensure the electricity system functions properly as the share from variable renewable generation continues to grow. Industrial manufacturing currently consumes about a third of primary energy worldwide, and electricity is projected to supply an increasing share of this demand as the global economy decarbonizes. Therefore, the ability for industry to flex demand poses an enticing opportunity to enable grid flexibility. However, large capital outlays prevent industry from voluntarily altering demand. Here we show that as battery costs continue to fall, industry will soon be able to profitably alter demand in accordance with electricity price variations. Focusing on two established industries– chlor-alkali and electric arc furnaces – and two industries with large future potential – methane pyrolysis and atmospheric CO 2 capture, we use a linear program (LP) optimization to assess the technoeconomic feasibility of flexible industrial demand across both historical and future-looking wholesale day-ahead marginal prices for the Electricity Reliability Council of Texas (ERCOT). We find positive net present values (NPV) from $\$$400K to $\$$50M using projected 2050 battery prices for industrial purchase of behind-the-meter batteries, using only arbitrage as a source of value. These results indicate that, with projected battery prices, profit-seeking industrial players could voluntarily play a future role in stabilizing a high-renewables grid where electricity prices act as accurate signals of grid needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of component size on PHEV energy consumption using global optimization.

Plug-in hybrid electric vehicles are a promising alternative to gas-only vehicles and offer the potential to greatly reduce fuel use in transportation. Their potential energy consumption is highly linked to the size of components. This study focuses on the impact of the electric system energy and power on control and energy consumption. Based on a parallel pre-transmission architecture, several vehicles were modeled, with an all-electric range from 5 to 40 miles on the UDDS, to illustrate various levels of available electric energy. Five others vehicles were created, with various levels of power and same battery energy. The vehicles were then simulated under optimal control on multiple combinations of cycle and distance by using a global optimization algorithm. The global optimization algorithm, based on the Bellman principle, ensures a fair comparison between different vehicles by making each vehicle operate at its maximal potential. The results from each optimization are thoroughly analyzed to highlight control patterns. The potential minimal fuel consumption that can be achieved by each of them is presented. The results can also be used to find the potential minimal greenhouse gases emissions.

54 ENVIRONMENTAL SCIENCES↗

Grid Planning Impacts of Hydropower Growth and Decline

Hydropower and pumped storage hydropower (PSH) have a complex and uncertain future in the U.S. electricity system. On one hand, existing assets have the potential for an expanded role in integrating variable renewable energy while new deployment, particularly of PSH, can help meet growing needs for grid flexibility and improved reliability. On the other hand, challenging environmental and cost considerations could limit the extent of new investments in hydropower and PSH capacity and flexibility. This technical presentation demonstrates the use of a high-fidelity capacity expansion model of the U.S. electric grid (the National Renewable Energy Laboratory's Regional Energy Deployment System) to understand the impacts of alternative futures for the hydropower and PSH fleet, including scenarios of both growth and decline. Growth scenarios include new PSH deployment or improved hydropower flexibility, while scenarios of decline reduce the capacity or energy production potential of hydropower and PSH. Economic, environmental, and performance outcomes of the grid are compared across these scenarios to reveal the potential contributions of hydropower and PSH in the U.S. electric sector over the next several decades, focusing on changes to the grid technology mix, electric sector costs, electricity prices, and air emissions. This broad scenario approach demonstrates how flexible hydropower and PSH can help reduce air emissions and cost by complementing variable renewables, but the opposite can occur with reduced hydropower availability, particularly in the next decade. It is important to consider a wide range of scenarios and metrics to gain a national and regional understanding of hydropower's future in the United States.

capacity expansion↗

Where the champsaur commission's critics Have got it wrong

In order to be constructive, the debate on markets versus electrical system regulation must be based on experience in real operating markets and regulated environments. If dogmatism prevails, it can fall into the contradiction of economical rationality. Unlike the U.S., where evolution has been driven by practice, the European Union wants to impose uniformity - electricity regulation regardless of individual countries' special circumstances. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of road load simulator test results with track tests on electric vehicle propulsion system

A special-purpose dynamometer, the road load simulator (RLS), is being used at NASA's Lewis Research Center to test and evaluate electric vehicle propulsion systems developed under DOE's Electric and Hybrid Vehicle Program. To improve correlation between system tests on the RLS and track tests, similar tests were conducted on the same propulsion system on the RLS and on a test track. These tests are compared in this report. Battery current to maintain a constant vehicle speed with a fixed throttle was used for the comparison. Scatter in the data was greater in the track test results. This is attributable to variations in tire rolling resistance and wind effects in the track data. It also appeared that the RLS road load, determined by coastdown tests on the track, was lower than that of the vehicle on the track. These differences may be due to differences in tire temperature.

Dustin, M. O.↗

Energetic Potential for Demand Response in Detached Single Family Homes in Austin, TX

This study builds a generalized tool to quantify the maximum peak load reduction achievable with residential demand response and distributed energy resources (DERs). The tool is demonstrated by using empirical energy usage data from detached single family households within the service territory of Austin Energy - the local municipal utility in Austin, TX. The demand response optimization algorithm shifts energy usage of four controllable, high-consumption residential devices to off-peak hours: HVAC (heating, ventilation, and air conditioning) systems, electric water heaters, electric vehicles, and pool pumps. In addition, rooftop solar generation on individual residences is considered to reduce net load to the utility, and an energy storage system optimization model performing energy arbitrage further reduces peak demand. Results from the aggregate demand response and battery optimization study indicate that peak demand for the 2017 summer peak in Austin Energy could have been reduced by 26 MW or 2.9%. Here, by considering the combined effect of controllable consumer loads, solar generation, and energy storage systems, this study highlights the potential of strategic demand response and energy arbitrage to reduce peak demand at the distribution level.

14 SOLAR ENERGY↗

Design, Test and Demonstration of Fault Current Limiting HTS Transformer

The project developed new technology that enables the creation of a high temperature superconductor-based FCL power transformer. SuperPower’s research and development created new methods to bond HTS conductor to a supporting substrate, test, and insulate the resulting bonded conductor, reduce winding ac losses, ensure FCL functionality during a transformer fault and build firm superconducting joints in the transformer harnesses and cabling. The bonded conductor in this program was shown to meet the critical operating parameters of providing the superconducting transformer operation while being able to meet the target normal state resistance required for FCL operation. The bonded conductor was also shown to be able to handle the fabrication stresses associated with the manufacture of the FCL transformer while also being able to handle the high hoop stresses and axial forces during a fault transient. Much of the technology developed here is applicable to the broader applied superconductivity community. The ability to tailor the clad conductors performance characteristics gives the designer of devices utilizing HTS a broader capability to address the particular needs of an given application. SuperPower worked with its sub-recipients Waukesha Electric Systems, ORNL, Southern California Edison and University of Houston to develop the design, fabrication, installation and operational aspects of a fault current limiting transformer on the electrical grid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Best Practices in Integrated Resource Planning: A guide for planners developing the electricity resource mix of the future

Most states today require regulated electric utilities to file an IRP every 1 to 5 years, and some utilities voluntarily prepare these plans. Planning needs have changed in recent years due to emerging load growth, plant retirements, rising costs, and more extreme weather events – among other factors. In response, Synapse Energy Economics and Lawrence Berkeley National Laboratory produced a joint report, Best Practices in Integrated Resource Planning: A guide for planners developing the electricity resource mix of the future. The guide offers best planning practices for electricity systems undergoing a major transition, but also contains a wealth of practical guidance to develop technically sophisticated, clearer, more effective, and state-of-the-art electric utility resource plans. The guide is for resource planning professionals and stakeholders involved in resource planning processes. This diverse group includes utility personnel tasked with conducting resource planning and making investment decisions, state regulatory commissions that develop planning guidance and oversee the resource planning process, and stakeholders that represent a wide range of interests—utility consumer advocates, environmental groups, industrial customers, local governments, independent power producers, and many other

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulation of an Electromechanical Spin Motor System of a Control Moment Gyroscope

A two-phase brushless DC motor (BDCM) with pulse-width modulated (PWM) voltage drive is simulated to control the flywheel speed of a control moment gyroscope (CMG). An overview of a double-gimballed control moment gyroscope (DGCMG) assembly is presented along with the CMG torque effects on the spacecraft. The operating principles of a two-phase brushless DC motor are presented and the system's electro-mechanical equations of motion are developed for the root-mean-square (RMS) currents and wheel speed. It is shown that the system is an extremely "stiff" set of first-order equations for which an implicit Euler integrator is required for a stable solution. An adaptive proportional voltage controller is presented which adjusts the PWM voltages depending on several control modes for speed, current, and torque. The simulation results illustrate the interaction between the electrical system and the load dynamics and how these influence the overall performance of the system. As will be shown, the CMG spin motor model can directly provide electrical power use and thermal power output to spacecraft subsystems for effective (average) calculations of CMG power consumption.

Inampudi, Ravi↗

AC propulsion system for an electric vehicle, phase 2

A second-generation prototype ac propulsion system for a passenger electric vehicle was designed, fabricated, tested, installed in a modified Mercury Lynx vehicle and track tested at the Contractor's site. The system consisted of a Phase 2, 18.7 kw rated ac induction traction motor, a 192-volt, battery powered, pulse-width-modulated, transistorized inverter packaged for under rear seat installation, a 2-axis, 2-speed, automatically-shifted mechanical transaxle and a microprocessor-based powertrain/vehicle controller. A diagnostics computer to assist tuning and fault finding was fabricated. Dc-to-mechanical-system efficiency varied from 78% to 82% as axle speed/torque ranged from 159 rpm/788 nm to 65 rpm/328 nm. Track test efficiency results suggest that the ac system will be equal or superior to dc systems when driving urban cycles. Additional short-term work is being performed under a third contract phase (AC-3) to raise transaxle efficiency to predicted levels, and to improve starting and shifting characteristics. However, the long-term challenge to the system's viability remains inverter cost. A final report on the Phase 2 system, describing Phase 3 modifications, will be issued at the conclusion of AC-3.

Slicker, J. M.↗

Power System Protection and Resilient Metrics

During a real-time power system event, a system operator need to conservatively reduce the operating limits while changing system conditions are analyzed. The time it takes to develop new operating limits could affect millions of transmission system users especially if this event is classified by NERC as a Category D type event (extreme events resulting in the loss of two or more bulk electric system elements) . Controls for the future grid must be able to perform real-time analysis, identify new reliability risks, and set new SOLs (System Operating Limit) for real-time operations. In this paper we are inducing “Resilience Metrics” requirements that describe how systems operate at an acceptable level of normalcy despite disturbances or threats. We consider the interdependencies inherent in critical infrastructure systems and discuss some resilience metrics that can be distributed in current supervisory control and data acquisition (SCADA) to provide a level of state awareness. This level of awareness provides knowledge that can be used to characterize and reduce the risk of cascading events. A “resilience power system agent” is proposed that provides attributes to measure and perform this metrics.

42 ENGINEERING↗

ARPA-E PNDIODES "PN Junctions by Ion Implantation" Project (Final Report)

Electricity accounts for nearly 40% of the energy generated in the United States, of which 65% is lost to electrical system inefficiency before reaching end-use sectors. Power electronics will play a growing role in this distribution and end-use, with up to 80% of electricity estimated to pass through power electronics from generation to consumption by 2030. This gives technical improvements in power electronics enormous potential to drive efficiency gains throughout the U.S. economy. Current Si-based power architectures including MOSFETs and IGBTs are limited by high losses, low switching frequency, and poor high-temperature performance. Given the material properties of GaN, devices can exhibit a given turn-on resistance and breakdown voltage with a minute fraction of the area of a Si device—all with higher switching speeds. While n-type doping of III-nitrides has reached a high level of maturity and integration into commercialized products, p-type doping presents distinct challenges that requires continued research. The success of the next generation of GaN-based power devices depends in large part on the ability to form selective-area p-type regions, which can be accomplished by ion implantation of the prevailing acceptor dopant, Mg. This approach is relatively inexpensive and is a fab-ready processing step for creation of current-generation power electronic devices including BJTs, IGBTs, and diode rectifiers. However, ion implantation induces lattice damage and creates point defects within the material, which negatively impacts dopant activation annealing. These forms of damage may be removed by high-temperature annealing, however short annealing time and higher pressures are required to prevent decomposition of the material. We approach this challenge through an innovative combination of approaches toward obtaining high-conductivity p-type GaN. By the novel employment of a gyrotron, a microwave source that can be shaped into a highly localized beam to dissipate very high power in a semiconductor target, a wafer of GaN can be annealed in short (<2 s) ‘pulses’ at temperatures of 1450 °C (2640 °F) to achieve p-type activation without appreciable surface degradation. The p-type activation of Mg-implanted GaN can be further aided by co-implantation with N, believed to enhance the removal of point defects that compensate the acceptors dopant. Elevation to such high temperatures for even a short time induces degradation of GaN-to overcome, we have implemented additional measures to retain high-quality crystalline GaN while removing implant damage and activating Mg dopant. A bilayer cap of AlN is deposited by a combination of chemical and physical vapor deposition to protect the GaN surface. To prevent decomposition of GaN loss of N during annealing, a custom vessel—to contain pressurized N while allowing injection of microwave energy—is employed. By detailed study of the interaction of various measures that are implemented to protect the sample surface (GaN), activate the implanted dopants, and mitigate damage of the lattice heating damage during annealing, we are able to achieve p-type GaN and observe recovery of the crystal and removal of substantial density of defects created during the implantation process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interactions of Wind Energy Project Siting, Wind Resource Potential, and the Evolution of the U.S. Power System

The interactions of wind energy project siting, resource potential, and power system evolution are critical to understand given interest in high renewable energy systems, particularly as wind costs have fallen and grid operators implement solutions to manage variable generation. This study applies an integrative approach that combines spatially-explicit resource potential analysis with high spatial resolution U.S. electricity system modeling. Multiple wind supply curves, representing variations in siting regimes that account for interactions with built infrastructure, regulatory, physical, and social land use factors, are evaluated to determine how siting could influence prospective wind development. Different siting regimes lead to variations in future wind capacity, with the greatest impacts observed under scenarios with high demand for clean energy. With the tightest emissions limit modeled, 2050 onshore wind capacity varied by +7% (49 GW) in the least-restrictive siting regime to a decrease of 37% (270 GW) under the most-constrained case. More-stringent siting restrictions lead to higher electricity prices and emissions that should be weighed with local impacts. Under restrictive siting regimes, wind deployment is also sensitive to transmission availability and wind plant design. Overall, the findings highlight the importance of local land use considerations in regional and national power system planning.

17 WIND ENERGY↗