Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

MR-Guided Freehand Biopsy of Liver Lesions With Fast Continuous Imaging Using a 1.0-T Open MRI Scanner: Experience in 50 Patients

The purpose of this study was to assess a new open system with a field-strength of 1.0 T for the feasibility of liver biopsy using the freehand technique with fast continuous imaging. Fifty patients with focal liver lesions measuring 5 to 30 mm in diameter were included in the study. Guidance and monitoring was performed using a 1.0-T open magnetic resonance (MR) scanner (Panorama HFO; Philips Healthcare, Best, The Netherlands). With fast continuous imaging using a T1-weighted (T1W) gradient echo (GRE) sequence after administration of gadolinium (Gd)-EOB-DTPA, the needle was placed into the lesion. An interface for interactive dynamic viewing in two perpendicular planes prevented needle deviations T2-weighted turbo spin echo (TSE) fat-suppressed sequence was added to rule out postinterventional hematoma or biloma. All lesions were visible on the interventional images. Biopsy was technically successful, and solid specimens were obtained in all cases. Forty-six patients showed a histopathologic pattern other than native liver tissue, thus confirming correct position of the needle. Time between determination of the lesion and performance of the control scan was on average 18 min. No major complications were recorded. MR guidance with the new 1-T open system must be considered an attractive alternative for liver punction. An interface for dynamic imaging of needle guidance and T1W-GRE imaging with administration of Gd-EOB-DTPA for contrast enhancement allows the pinpoint puncture of liver lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Fast Spectral Galerkin Method for Hypersingular Boundary Integral Equations in Potential Theory

This research is focused on the development of a fast spectral method to accelerate the solution of three-dimensional hypersingular boundary integral equations of potential theory. Based on a Galerkin approximation, the Fast Fourier Transform and local interpolation operators, the proposed method is a generalization of the Precorrected-FFT technique to deal with double-layer potential kernels, hypersingular kernels and higher-order basis functions. Numerical examples utilizing piecewise linear shape functions are included to illustrate the performance of the method.

97 MATHEMATICS AND COMPUTING↗

Fast Algorithm for Evaluating Critical Current of High-Temperature Superconducting Pancake Coil

Second-generation (2G) high-temperature superconducting (HTS) tapes are now capable of carrying very high transport current and promising for a wide range of applications. The critical current of HTS coils is important for applications, such as superconducting electric machines, superconducting magnetic energy storage, and superconducting magnets. Therefore, precisely and quickly calculating critical current of HTS coils is very important for designing HTS devices. This paper provides a fast algorithm for evaluating critical current of HTS pancake coil. The fast algorithm is realized through a stationary model, which is based on finite element method (FEM) software. The stationary model means that the model is solved by stationary study instead of time-dependent study. To validate this method, a pancake HTS coil was wound and its critical current was measured. Meanwhile, an axial symmetric stationary model was built according to the geometry of the measured HTS coil. By comparing measured and calculated results, the effectiveness of the stationary model was demonstrated. Moreover, the stationary model is compared with H formulation model. The calculated results by the two models are nearly the same. However, by using stationary calculation, the stationary model can remarkably speed up the computational process. Due to the advantage of calculating speed, the stationary model can be used to characterize and design large-scale HTS applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stopping of Fast Structural Ions in a Substance by Means of Excitation of Their Own Electrons

The paper considers the theory of stopping of fast structural ions in a substance. Within the eikonal approximation, it develops a non-perturbative method for calculation of effective stopping of fast structural ions by means of excitation of their own electrons during collision with atoms. It shows that taking into account the interaction of atoms with the ion nucleus can make a considerable contribution into the value of the abovementioned effective stopping. It also examines the dependence of this contribution on the charge of the ion nucleus.

74 ATOMIC AND MOLECULAR PHYSICS↗

Differential regulation of apoptosis in slow and fast twitch muscles of aged female F344BN rats

Age-related muscle atrophy is characterized by decreases in muscle mass and is thought be mediated, at least in part, by increases in myocyte apoptosis. Recent data has demonstrated that the degree of muscle loss with aging may differ between males and females while other work has suggested that apoptosis as indicated by DNA fragmentation may be regulated differently in fast- and slow-twitch muscles. Herein, we investigate how aging affects the regulation of muscle apoptosis in the fast-twitch extensor digitorum longus (EDL) and slow-twitch soleus muscles of young (6-month), aged (26-month), and very aged (30-month) female Fischer 344/NNiaHSD × Brown Norway/BiNia (F344BN) rats. Tissue sections were stained with hydroethidium for ROS and protein extract was subjected to immunoblotting for assessing apoptotic markers. Our data suggest that decreases in muscle mass were associated with increased DNA fragmentation (TUNEL positive) and increases in reactive oxygen species (ROS) as determined by hydroethidium staining in both the EDL and soleus. Similar to our previous work using aged male animals, we observed that the time course and magnitude of changes in Bax, Bcl-2, caspase-3, caspase-9, and cleavage of α-fodrin protein were regulated differently between muscles. As a result, These data suggest that aging in the female F344BN rat is associated with decreases in muscle mass, elevations in ROS level, increased muscle cell DNA fragmentation, and alterations in cell membrane integrity and that apoptotic mechanisms may differ between fiber types.

59 BASIC BIOLOGICAL SCIENCES↗

Energetic Ion Irradiation-Induced Disordered Nanochannels for Fast Ion Conduction

We report that atomically disordered oxides are seen as suitable candidate for fast oxygen conduction due to their remarkable enhancement in oxygen diffusivity compared with ordered oxides. In particular, disordered derivatives of pyrochlore-structured oxides (A 2 B 2 O 7 ) are seen as an interesting prospect due to the intrinsic existence of oxygen vacancies in their lattice. Using energetic ion irradiation, we demonstrated fabrication of structurally disordered nanoscale channels in A 2 B 2 O 7 (A = Gd, Yb; B = Ti, Zr) that act as selective pathways for fast oxygen conduction. Atomic-level characterization revealed that the amorphous core and surrounding defect-fluorite phase in the nanochannels exhibited distorted and differently coordinated Ti-O polyhedra, with very similar electronic structure. Lastly, the formation of defect-fluorite structure is facilitated by a decrease in the difference between the ionic radii of A- and B-site cations in the lattice.

36 MATERIALS SCIENCE↗

Fast myocardial perfusion imaging with {sup 99m}Tc in challenging patients using conventional SPECT cameras

Background: We attempted to validate the performance of a fast myocardial perfusion imaging (MPI) protocol in diagnostically challenging patients. Methods: 78 patients with ΒΜΙ > 24.9, LVH or three vessels disease underwent two sequential gated-MPI studies. The first at 15 (Early Imaging, EI) and the second at 45 (Late Imaging, LI) minutes post {sup 99m}Tc-injection, at both stress and rest. Counts over heart (H), liver (Liv) and subdiaphragmatic space (Sub) and image quality, and myocardial perfusion and function parameters were compared between the two protocols. Coronary angiography was performed within 2 months from MPI, and ROC analysis was used to compare the diagnostic accuracy for the detection of ≥50% diameter luminal stenosis. Results: Quality was optimal-good in 93% of EI and 98% of LI studies (P = .12), H/Liv and stress H/Sub ratios were similar, but rest H/Sub ratio was lower in EI (P = .009). SSS [10 (0 to 46) vs 9 (0 to 36), P = .006] and SDS [3 (0 to 35) vs 2 (0 to 34), P = .02] were higher in EI protocol. LVEF, motion and thickening scores did not differ between the two protocols. A highly significant (P < .001) linear relationship with clinically negligible mean differences in Bland-Altman analysis was observed for all perfusion and function-related data. Sensitivity (EI 81%, LI 80%) and specificity (65% for both) did not differ (P = .23) between the two protocols. Conclusion: The fast protocol is technically feasible and diagnostically accurate compared to the established protocol in diagnostically challenging patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis-Specific Fast Simulation at the LHC with Deep Learning

Abstract We present a fast-simulation application based on a deep neural network, designed to create large analysis-specific datasets. Taking as an example the generation of W + jet events produced in $$\sqrt{s}=$$ s = 13 TeV proton–proton collisions, we train a neural network to model detector resolution effects as a transfer function acting on an analysis-specific set of relevant features, computed at generation level, i.e., in absence of detector effects. Based on this model, we propose a novel fast-simulation workflow that starts from a large amount of generator-level events to deliver large analysis-specific samples. The adoption of this approach would result in about an order-of-magnitude reduction in computing and storage requirements for the collision simulation workflow. This strategy could help the high energy physics community to face the computing challenges of the future High-Luminosity LHC.

Chen, C.↗

Modeling a fast spectrum molten salt reactor in a systems dynamics fuel cycles code

Molten salt reactor (MSR) concepts are being actively developed by several private companies, with some touting the fuel cycle benefits of this technology. Simulating the deployment of MSRs and their effect on fuel cycle transitions is the role of a system dynamics fuel cycles tool. However, many current fuel cycles tools have difficulty modeling MSR isotopic variations because they were designed for modeling existing reactors based on discrete fuel elements with batch fueling schemes (i.e., charge and discharge). This work presents ORION fuel cycle modeling results using a specific high power density fast spectrum MSR design. For code verification, a single-stage MSR fuel cycle was set up in ORION and results were compared with the results from the SCALE-based reactor physics model (ChemTriton). A transition scenario was set up in ORION from the current light water reactor fleet to a future fleet of MSRs to study the characteristics of an MSR that affect its performance during transition. Several transition scenarios were set with holds and delays in place that are representative of a sodium fast reactor as modeled in Evaluation Group 23 for the Fuel Cycle Options Campaign Evaluation and Screening Study. Several MSR characteristics lend to its high performance and ease in transition from the current fuel cycle: fissile material is only loaded at initial startup; all fissile material is available as it is bred due to online fuel processing; and fissile material recirculating through the core is briefly held in tanks for processing and has very minimal out-of-core time (on the order of a minutes to a few days). These characteristics are in contrast to a solid-fueled reactor, which requires discharge, cooling, and fabrication of fuel all of which could take a few months to a few years and repeated loading of fresh fuel assemblies. In conclusion, a solid-fueled reactor only discharges a fraction of a core every year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast-regenerable sulfur dioxide absorbents for lean-burn diesel engine emission control

It is known that sulfur oxides contribute significantly and deleteriously to the overall performance of lean-burn diesel engine aftertreatment systems, especially in the case of NOx traps. A Ag-based, fast regenerable SO2 absorbent has been developed and will be described. Over a temperature range of 300oC to 550oC, it absorbs almost all of the SO2 in the simulated exhaust gases during the lean cycles and can be fully regenerated by the short rich cycles at the same temperature. Its composition has been optimized as 1 wt% Pt-5wt%Ag-SiO2, and the preferred silica source for the supporting material has been identified as inert Cabosil fumed silica. The thermal instability of Ag2O under fuel-lean conditions at 230oC and above makes it possible to fast regenerate the sulfur-loaded absorbent during the following fuel-rich cycles. Pt catalyst helps reducing Ag2SO4 during rich cycles at low temperatures. And the chemically inert fumed SiO2 support gives the absorbent long term stability. This absorbent shows great potential to work under the same lean-rich cycling conditions as those imposed on the NOx traps, and thus, can protect the downstream particulate filter and the NOx trap from sulfur poisoning.

33 ADVANCED PROPULSION SYSTEMS↗

Validation of a simple and fast method to quantify in vitro mineralization with fluorescent probes used in molecular imaging of bone

Highlights: •We validate a simple and fast method of quantification of in vitro mineralization. •Fluorescently labeled agents can detect calcium deposits in the mineralized matrix of cell cultures. •Fluorescent signals of the probes correlated with Alizarin Red S staining. -- Abstract: Alizarin Red S staining is the standard method to indicate and quantify matrix mineralization during differentiation of osteoblast cultures. KS483 cells are multipotent mouse mesenchymal progenitor cells that can differentiate into chondrocytes, adipocytes and osteoblasts and are a well-characterized model for the study of bone formation. Matrix mineralization is the last step of differentiation of bone cells and is therefore a very important outcome measure in bone research. Fluorescently labelled calcium chelating agents, e.g. BoneTag and OsteoSense, are currently used for in vivo imaging of bone. The aim of the present study was to validate these probes for fast and simple detection and quantification of in vitro matrix mineralization by KS483 cells and thus enabling high-throughput screening experiments. KS483 cells were cultured under osteogenic conditions in the presence of compounds that either stimulate or inhibit osteoblast differentiation and thereby matrix mineralization. After 21 days of differentiation, fluorescence of stained cultures was quantified with a near-infrared imager and compared to Alizarin Red S quantification. Fluorescence of both probes closely correlated to Alizarin Red S staining in both inhibiting and stimulating conditions. In addition, both compounds displayed specificity for mineralized nodules. We therefore conclude that this method of quantification of bone mineralization using fluorescent compounds is a good alternative for the Alizarin Red S staining.

60 APPLIED LIFE SCIENCES↗

Fast conformational exchange between the sulfur-free and persulfide-bound rhodanese domain of E. coli YgaP

Highlights: • Three dimensional solution NMR structure of YgaP rhodanese domain. • Function validation of YgaP rhodanese domain to substrate Na{sub 2}S{sub 2}O{sub 3}. • Fast exchange between the intact and persulfide-intermediate rhodanese domain. - Abstract: Rhodanese domains are abundant structural modules that catalyze the transfer of a sulfur atom from thiolsulfates to cyanide via formation of a covalent persulfide intermediate that is bound to an essential conserved cysteine residue. In this study, the three-dimensional structure of the rhodanese domain of YgaP from Escherichia coli was determined using solution NMR. A typical rhodanese domain fold was observed, as expected from the high homology with the catalytic domain of other sulfur transferases. The initial sulfur-transfer step and formation of the rhodanese persulfide intermediate were monitored by addition of sodium thiosulfate using two-dimensional {sup 1}H–{sup 15}N correlation spectroscopy. Discrete sharp signals were observed upon substrate addition, indicting fast exchange between sulfur-free and persulfide-intermediate forms. Residues exhibiting pronounced chemical shift changes were mapped to the structure, and included both substrate binding and surrounding residues.

60 APPLIED LIFE SCIENCES↗

Investigating biomass composition and size effects on fast pyrolysis using global sensitivity analysis and CFD simulations

It is notoriously difficult to build an accurate universal model for biomass pyrolysis due to its sensitivity to a wide number of critical material attributes such as chemical species and physical sizes. In this work, a biomass pyrolysis kinetics with 32 heterogeneous reactions and 59 species was implemented in an open-source multiphase computational fluid dynamics (CFD) software MFiX and validated against two different experimental pyrolysis data sets that provided detailed data describing chemical component yields. The reaction scheme was then used to build a surrogate model and assess the sensitivity of pyrolysis yields to feedstock compositions. The sensitivity analysis determined that the yield of bio-char showed a strong positive sensitivity to the carbon-rich lignin and tannin pseudo-species in the reaction scheme while the bio-oil and bio-gas were correlated to oxygen-rich lignin pseudo-species. The reaction scheme was then integrated into a coarse-grained discrete element model to simulate fast pyrolysis in a bubbling fluidized bed over a range of feedstock particle sizes. The reactor simulations showed further sensitivity to particle size and hydrodynamics. Notably, particles under 0.5 mm have small heat transfer limitations but left the reactor before completely converting and thus reduced the bio-oil yield. Results from this study can be used to guide future development of highly accurate models for fast pyrolysis reactors with a variety of feedstock properties and operating conditions.

09 BIOMASS FUELS↗

Multiscale CFD simulation of biomass fast pyrolysis with a machine learning derived intra-particle model and detailed pyrolysis kinetics

Coupling particle and reactor scale models is as essential as reactor fluid dynamics and particle motion for accurate Computational Fluid Dynamic (CFD) simulations of biomass fast pyrolysis reactors due to intraparticle heat transfer and chemical reactions controlling conversion time and product distributions. Direct online coupling of a particle model with a reactor model is computationally expensive, while offline coupling is case-dependent. In this research, solutions from a series of particle pyrolysis simulations were regressed with Artificial Neural Network (ANN). Furthermoer, this machine learning-derived model predicted the same temperature and conversion profiles compared with particle resolved simulation while the isothermal approach overpredicted the temperature by 130 K and underpredicted the conversion time by 30 s. The ANN model was then integrated into CFD simulations of fluidized bed biomass fast pyrolysis with varied feedstocks via coupling PyTorch and MFiX. The averaged error of simulation predicted bio-oil yields with four feedstocks is 6.4%. This multi-scale approach provides an efficient tool for the coupled particle and reactor scale simulations of biomass pyrolysis.

09 BIOMASS FUELS↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

High pressure FAST of nanocrystalline barium titanate

Here, this work studies the microstructural evolution of nanocrystalline (<1 µm) barium titanate (BaTiO 3 ), and presents high pressure in field-assisted sintering (FAST) as a robust methodology to obtain >100 nm BaTiO 3 compacts. Using FAST, two commercial ~50 nm powders were consolidated into compacts of varying densities and grain sizes. Microstructural inhomogeneities were investigated for each case, and an interpretation is developed using a modified Monte Carlo Potts (MCP) simulation. Two recurrent microstructural inhomogeneities are highlighted, heterogeneous grain growth and low-density regions, both ubiqutously present in all samples to varying degrees. In the worst cases, HGG presents an area coverage of 52%. Because HGG is sporadic but homogenous throughout a sample, the catalyst (e.g., the local segregation of species) must be, correspondingly, distributed in a homogenous manner. MCP demonstrates that in such a case, a large distance between nucleating abnormal grains is required—otherwise abnormal grains prematurely impinge on each other, and their size is not distinguishable from that of normal grains. Compacts sintered with a pressure of 300 MPa and temperatures of 900 °C, were 99.5% dense and had a grain size of 90±24 nm. These are unprecedented results for commercial BaTiO 3 powders or any starting powder of 50 nm particle size—other authors have used 16 nm lab-produced powder to obtain similar results.

36 MATERIALS SCIENCE↗

Microstructural characterization and assessment of mechanical properties of concrete based on combined elemental analysis techniques and Fast-Fourier transform-based simulations

This paper presents a pixel-based modeling approach of concrete which combines an experimental characterization of concrete and the Fast-Fourier transform simulations. High-resolution phase maps created from experimental characterization by micro X-ray fluorescence, energy dispersive X-ray analysis, and X-ray diffraction contain 9 different phases, including 22.17 vol.% of hydrated cement paste, 54.21 vol.% of minerals, and 23.62 vol.% of interfaces. These phases provide the input for determining the effective elastic properties, coupled with Fast-Fourier transform-based simulation. The simulation results show that the effective range of Young’s modulus of concrete is comparable with the range of experimental values ~ 37 ± 4 GPa with the assumption of realistic properties of interfaces.

36 MATERIALS SCIENCE↗

Piecewise linear approximation with minimum number of linear segments and minimum error: A fast approach to tighten and warm start the hierarchical mixed integer formulation

In several areas of economics and engineering, it is often necessary to fit discrete data points or approximate nonlinear functions with continuous functions. Piecewise linear (PWL) functions are a convenient way to achieve this. PWL functions can be modeled in mathematical problems using only linear and integer variables. Moreover, there is a computational benefit in using PWL functions that have the least possible number of segments. This work proposes a novel hierarchical mixed integer linear programming (MILP) formulation that identifies a continuous PWL approximation with minimum number of linear segments for a given target maximum error. The proposed MILP formulation also identifies the solution with the least maximum error among the solutions with minimum number of segments. Then, this work proposes a fast iterative algorithm that identifies non necessarily continuous PWL approximations by solving O(S log N) linear programming (LP) problems, where N is the number of data points and S is the minimum number of segments in the non necessarily continuous case. This work demonstrates that tight bounds for the MILP problem can be derived from these approximations. Next, a fast algorithm is introduced to transform a non necessarily continuous PWL approximation into a continuous one. Finally, the tight bounds and the continuous PWL approximations are used to tighten and warm start the MILP problem. The tightened formulation is shown in experimental results to be more efficient, especially for large data sets, with a solution time that is up to two orders of magnitude less than the existing literature.

97 MATHEMATICS AND COMPUTING↗