Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Controlled particle transport in a plasma chamber with striped electrode

The controlled transport of micrometer size dust particles in a parallel-plate radio frequency discharge has been investigated. The lower stainless steel electrode consisted of 100 independently controllable electrical metal stripes. The voltage signals on these stripes were modulated, causing traveling plasma sheath distortions. Because the particles trapped in local potential wells moved according to the direction of the distortion, the transport velocity could be actively controlled by adjusting frequencies and phase shifts of the applied periodic voltage signals. To investigate the detailed principle of this transport, molecular dynamic simulations was performed to reproduce the observations with the plasma background conditions calculated by separated particle-in-cell simulations for the experimental parameters. The findings will help develop novel technologies for investigating large-scale complex plasma systems and techniques for achieving clean environments in plasma processing reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mode-locked thulium-fluoride fibre laser with an adjustable pulse width using a nonlinear optical loop mirror

A mode-locked thulium-fluoride fibre laser with a tunable pulse width using a nonlinear optical loop mirror (NOLM) for operation in the S-band region is proposed and demonstrated. Stable dissipative soliton resonance (DSR) mode-locked pulses are obtained at a threshold pump power of 186.8 mW and maintain stability until a maximum pump power of 249.7 mW. Pulse width modulation of between 70.8 ns and 120.3 ns is obtained over the operating pump power range, with a fundamental frequency at 97.4 kHz. A maximum output power of 0.99 mW and a pulse energy of 10.21 nJ are obtained. The output pulse has a signal-to-noise ratio of 69 dB at the maximum pump power, indicating a highly stable output. The variable pulse width will find significant applications as modulated light sources for various optical and optoelectronic systems. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Cryogenic Preamplification of a Single-Electron-Transistor using a Silicon-Germanium Heterojunction-Bipolar-Transistor

We examine a silicon-germanium heterojunction bipolar transistor (HBT) for cryogenic pre-amplification of a single electron transistor (SET). The SET current modulates the base current of the HBT directly. The HBT-SET circuit is immersed in liquid helium, and its frequency response from low frequency to several MHz is measured. The current gain and the noise spectrum with the HBT result in a signal-to-noise-ratio (SNR) that is a factor of 10–100 larger than without the HBT at lower frequencies. Furthermore, the transition frequency defined by SNR = 1 has been extended by as much as a factor of 10 compared to without the HBT amplification. The power dissipated by the HBT cryogenic pre-amplifier is approximately 5 nW to 5 μW for the investigated range of operation. We found that the circuit is also operated in a single electron charge read-out configuration in the time-domain as a proof-of-principle demonstration of the amplification approach for single spin read-out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dispersive Charge Transfer State Electroluminescence in Organic Solar Cells

Abstract The notion of quasi‐equilibrium is central to most solar cells; however, it has been questioned in organic photovoltaics (OPVs) owing to strong energetic disorder that frustrates efficient relaxation of electrons and holes within their respective density of states (DOS). Here, modulation electroluminescence (EL) spectroscopy is applied to OPVs and it is found that the frequency response of charge transfer (CT) state EL on the high energy side of the spectrum differs from that of the low energy side. This observation confirms that static disorder contributes substantially to the linewidth of the steady‐state EL spectrum and is unambiguous proof that the distribution of CT states formed by electrical injection in the dark is not in quasi‐equilibrium. These results emphasize the need for caution when analyzing OPV cells on the basis of reciprocity models that assume quasi‐equilibrium holds, and highlight a new method to study this unusual aspect of OPV operation.

14 SOLAR ENERGY↗

Intensive and extensive margins of the peak load: Measuring adaptation with mixed frequency panel data

In this work we investigate the response of daily electricity peak load to daily maximum temperatures across states in Europe and India. We propose a method that decomposes short- from medium/long-run effects, retains the high frequency nature of the load-weather covariation and treats economic growth as a modulating factor. By simultaneously exploiting variation in unexpected daily weather anomalies and decade-long climatic changes in each location we decompose transitory - intensive margin - adjustments from permanent - extensive margin - adjustments. We find that the shocks over the long-run differ substantially from the short-run dynamics. Furthermore, we find evidence that per capita income modulates the adjustments over the short- and long-run. We project that in response to climate change around 2050 the peak load may increase by up to 20%-30% in Southern Europe and in several states in India, depending on the degree of warming and the evolution of socio-economic conditions. Even with a limited scope to two world regions, we identify that the structure of the economy and differences in future income growth matter in shaping the adaptation to climate change. Our decomposition allows to identify how future weather anomalies can further amplify the relative increase associated to the shift in the climate norm. Assuming that the interannual variability of maximum temperatures follows the distribution observed in the past, we find a doubling of the impacts of climate change during the summer in Europe. Uncertainty around the distribution of future weather anomalies may lead to further unexpected peak load amplifications. Our results have important policy implications for power systems’ generation capacity, transmission and storage, as we show that the challenges to accommodate the peak load in days with extreme temperatures may substantially increase already around mid-century.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of Body Mass Index on Magnitude of Setup Errors in Patients Treated With Adjuvant Radiotherapy for Endometrial Cancer With Daily Image Guidance

Purpose: To determine the impact of body mass index (BMI) on daily setup variations and frequency of imaging necessary for patients with endometrial cancer treated with adjuvant intensity-modulated radiotherapy (IMRT) with daily image guidance. Methods and Materials: The daily shifts from a total of 782 orthogonal kilovoltage images from 30 patients who received pelvic IMRT between July 2008 and August 2010 were analyzed. The BMI, mean daily shifts, and random and systematic errors in each translational and rotational direction were calculated for each patient. Margin recipes were generated based on BMI. Linear regression and spearman rank correlation analysis were performed. To simulate a less-than-daily IGRT protocol, the average shift of the first five fractions was applied to subsequent setups without IGRT for assessing the impact on setup error and margin requirements. Results: Median BMI was 32.9 (range, 23-62). Of the 30 patients, 16.7% (n = 5) were normal weight (BMI <25); 23.3% (n = 7) were overweight (BMI {>=}25 to <30); 26.7% (n = 8) were mildly obese (BMI {>=}30 to <35); and 33.3% (n = 10) were moderately to severely obese (BMI {>=} 35). On linear regression, mean absolute vertical, longitudinal, and lateral shifts positively correlated with BMI (p = 0.0127, p = 0.0037, and p < 0.0001, respectively). Systematic errors in the longitudinal and vertical direction were found to be positively correlated with BMI category (p < 0.0001 for both). IGRT for the first five fractions, followed by correction of the mean error for all subsequent fractions, led to a substantial reduction in setup error and resultant margin requirement overall compared with no IGRT. Conclusions: Daily shifts, systematic errors, and margin requirements were greatest in obese patients. For women who are normal or overweight, a planning target margin margin of 7 to 10 mm may be sufficient without IGRT, but for patients who are moderately or severely obese, this is insufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oceanic fronts shape hemispheric contrasts in polar stratospheric extremes

Sudden Stratospheric Warmings (SSWs) and Polar Stratospheric Clouds (PSCs) exhibit striking inter-hemispheric asymmetries: SSWs are frequent in the Arctic but rare in the Antarctic, while PSCs are more persistent in the Antarctic. Although land–sea thermal contrast and orography (LSCO) have been traditionally invoked to explain these asymmetries, here we show using semi-idealized model experiments that even though LSCO strongly impacts the mean state of SSWs and PSCs, it alone cannot fully account for the observed differences. Using model experiments, we reveal that midlatitude oceanic sea surface temperature (SST) fronts represent a crucial supporting additional driver of the hemispheric stratospheric differences. Like LSCO, SST fronts enhance stratospheric convergence of resolved waves, strengthening the Brewer–Dobson Circulation and inducing high-latitude adiabatic warming. This warming significantly enhances Arctic SSW frequency and strongly suppresses PSC formation. Sub-grid-scale non–resolved wave forcing modulates the stratospheric resolved waves effect. The oceanic impact is dominated by North Pacific SST fronts. Our results highlight the indispensable role of SST fronts in shaping Arctic–Antarctic asymmetries in stratospheric dynamics and associated extremes.

Omrani, Nour-Eddine [Univ. of Bergen (Norway)] (OR↗

Femtosecond time-resolved x-ray diffraction from optical coherent phonons in CdTe(111) crystal

Coherent phonons excited in a CdTe(111) crystal by 70 fs laser irradiation have been investigated by femtosecond time-resolved x-ray diffraction. The longitudinal optical phonon with a frequency of approximately 5 THz near the Brillouin zone center has been detected as modulation in intensities of x-ray diffraction. Atomic displacement in the [111] direction in the coherent longitudinal optical phonon has been estimated.

36 MATERIALS SCIENCE↗

Rotation dependence of a phase delay between plasma edge electron density and temperature fields due to a fast rotating, resonant magnetic perturbation field

Measurements of the plasma edge electron density n{sub e} and temperature T{sub e} fields during application of a fast rotating, resonant magnetic perturbation (RMP) field show a characteristic modulation of both, n{sub e} and T{sub e} coherent to the rotation frequency of the RMP field. A phase delay PHI between the n{sub e}(t) and T{sub e}(t) waveforms is observed and it is demonstrated that this phase delay PHI is a function of the radius with PHI(r) depending on the relative rotation of the RMP field and the toroidal plasma rotation. This provides for the first time direct experimental evidence for a rotation dependent damping of the external RMP field in the edge layer of a resistive high-temperature plasma which breaks down at low rotation and high resonant field amplitudes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

60 APPLIED LIFE SCIENCES↗

Frequency-selective excitation of high-wavevector phonons

We demonstrate here the selective excitation of a narrow frequency band of TA phonons throughout the Brillouin zone of germanium using a sinusoidally modulated picosecond laser pulse. The pulse is produced through the combination of two chirped and delayed pulses using a stabilized interferometer. The phonon excitations are probed by time- and momentum- resolved x-ray diffuse scattering.

36 MATERIALS SCIENCE↗

Toward improved quantum simulations and sensing with trapped two-dimensional ion crystals via parametric amplification

Improving coherence is a fundamental challenge in quantum simulation and sensing experiments with trapped ions. Here we discuss, experimentally demonstrate, and estimate the potential impacts of two different protocols that enhance, through motional parametric excitation, the coherent spin-motion coupling of ions obtained with a spin-dependent force. The experiments are performed on two-dimensional crystal arrays of approximately 100 9 ⁢Be + ions confined in a Penning trap. By modulating the trapping potential at close to twice the center-of-mass mode frequency, we squeeze the motional mode and enhance the spin-motion coupling while maintaining spin coherence. With a stroboscopic protocol, we measure 5.4 ± 0.9 dB of motional squeezing below the ground-state motion, from which theory predicts a 10-dB enhancement in the sensitivity for measuring small displacements using a recently demonstrated protocol [K. A. Gilmore et al., Science 373, 673 (2021)]. With a continuous squeezing protocol, we measure and accurately calibrate the parametric coupling strength. Theory suggests this protocol can be used to improve quantum spin squeezing, limited in our system by off-resonant light scatter. Finally, we illustrate numerically the trade-offs between strong parametric amplification and motional dephasing in the form of center-of-mass frequency fluctuations for improving quantum spin squeezing in our setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-206-06: Task-Specific Optimization of Scintillator Thickness for CMOS-Detector Based Cone-Beam Breast CT

Purpose: To optimize the cesium iodide (CsI:Tl) scintillator thickness in a complimentary metal-oxide semiconductor (CMOS)-based detector for use in dedicated cone-beam breast CT. Methods: The imaging task considered was the detection of a microcalcification cluster comprising six 220µm diameter calcium carbonate spheres, arranged in the form of a regular pentagon with 2 mm spacing on its sides and a central calcification, similar to that in ACR-recommended mammography accreditation phantom, at a mean glandular dose of 4.5 mGy. Generalized parallel-cascades based linear systems analysis was used to determine Fourier-domain image quality metrics in reconstructed object space, from which the detectability index inclusive of anatomical noise was determined for a non-prewhitening numerical observer. For 300 projections over 2π, magnification-associated focal-spot blur, Monte Carlo derived x-ray scatter, K-fluorescent emission and reabsorption within CsI:Tl, CsI:Tl quantum efficiency and optical blur, fiberoptic plate transmission efficiency and blur, CMOS quantum efficiency, pixel aperture function and additive noise, and filtered back-projection to isotropic 105µm voxel pitch with bilinear interpolation were modeled. Imaging geometry of a clinical prototype breast CT system, a 60 kV Cu/Al filtered x-ray spectrum from 0.3 mm focal spot incident on a 14 cm diameter semi-ellipsoidal breast were used to determine the detectability index for 300–600 µm thick (75µm increments) CsI:Tl. The CsI:Tl thickness that maximized the detectability index was considered optimal. Results: The limiting resolution (10% modulation transfer function, MTF) progressively decreased with increasing CsI:Tl thickness. The zero-frequency detective quantum efficiency, DQE(0), in projection space increased with increasing CsI:Tl thickness. The maximum detectability index was achieved with 525µm thick CsI:Tl scintillator. Reduced MTF at mid-to-high frequencies for 600µm thick CsI:Tl lowered the detectability index than 525µm CsI:Tl. Conclusion: For the x-ray spectrum and imaging conditions considered, a 525µm thick CsI:Tl scintillator integrated with the CMOS detector is optimal for detecting microcalcification cluster. Funding support: Supported in part by NIH R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI. Disclosures: SV, GV and AK - Research collaboration, Koning Corp., West Henrietta, NY.

60 APPLIED LIFE SCIENCES↗

From broadband biphotons to frequency combs via spectral compression with time-varying cavities

Biphoton frequency combs are promising resources for quantum networking due in large part to their compatibility with the telecommunication infrastructure. Here, in this work, we propose a method to periodically compress broadband frequency-entangled photons into biphoton frequency combs by utilizing time-varying linear cavities. Our approach hinges on rapid modulation of the input cavity coupling, yielding high spectral purity in each output comb line similar to that achieved with narrowband filters, but without the associated loss in flux. We examine the dependence of spectral purity and compression on coupling strength, cavity loss, and switching speed, finding realistic regimes supporting purities in excess of 0.999 and peak enhancement factors of 100× and beyond.

Myilswamy, Karthik V. [Purdue Univ., West Lafayett↗

Spatiotemporal refraction of light in an epsilon-near-zero indium tin oxide layer: frequency shifting effects arising from interfaces

When light travels through a medium in which the refractive index is rapidly changing with time, the light will undergo a shift in its frequency. Significant frequency shifting effects have recently been reported for transparent conductive oxides. These observations have been interpreted as emerging from temporal changes to the propagation phase in a bulk medium resulting from temporal variations in the refractive index. It is an effect referred to as temporal refraction. Here, we show that the frequency shift in an epsilon-near-zero layer made of indium tin oxide originates not only from this bulk response but includes a significant effect resulting from temporal changes to the spatial boundary conditions. This boundary effect can lead to a dominant, opposing shift to the bulk effect for certain angles. Hence, this process gives rise to a frequency shift that can be tailored through the angle, decoupling the amplitude and phase modulation.

Bohn, Justus (ORCID:0000000214376450)↗

Klystron switching power supplies for the Internation Linear Collider

The International Linear Collider is a majestic High Energy Physics particle accelerator that will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. ILC will complement the Large Hadron Collider (LHC), a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, by producing electron-positron collisions at center of mass energy of about 500 GeV. In particular, the subject of this dissertation is the R&D for a solid state Marx Modulator and relative switching power supply for the International Linear Collider Main LINAC Radio Frequency stations.

43 PARTICLE ACCELERATORS↗

TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was funded by ViewRay, Inc., Oakwood, OH.

60 APPLIED LIFE SCIENCES↗