Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

DOE published a report in November 2017 (herein referred to as “Part 1”) summarizing the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed (CLTB) in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines published by the American National Standards Institute (ANSI) C137 Lighting Systems Committee in 2017. The guidance offered in ANSI C137.3-2017 was found to be effective in limiting cable energy losses to 5% in PoE lighting applications, provided that the average cable length on a project does not exceed 50 m. This Part 2 report summarizes the results of a continued investigation of the power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the PNNL CLTB in July-August 2018. A test setup comprising a PoE switch, a set of luminaires, and a reference meter was again used to test multiple cable models of varying design. The results were analyzed to explore the impact of cable selection and installation practices (e.g., cable bending, cable bundling, and installation in conduit) on PoE lighting system energy efficiency, as well as the effectiveness of the ANSI C137.3 guidelines. Notably, three cables—two of which were shielded—were previously excluded from the Part 1 study due to compatibility issues. All three cables were included in this Part 2 study, along with a fourth model cable introduced in Part 2. In addition, whereas no patch cords were used in Part 1, patch cords were used in some Part 2 testing. The ANSI C137.3 guidance was again shown to effectively limit power losses to less than 5% in the cables tested (varying in AWG, Category, shielding, fire rating, and manufacturer), and AWG again proved to be the most important cable design variable for energy performance, as expected. However, these findings should not be construed as being representative of all cable models and installation practices. For example, energy losses would be greater when cables are connected to patch cords, bundled in conduit, and loaded with powered devices (PDs) approaching 100 W input power. The other key finding was that with 44 W luminaires as PDs and room ambient temperatures below 30°C, cable energy losses were not substantially increased by cable bending or bundling in uninsulated conduit. However, environments with higher ambient temperatures will have greater energy losses due to increased conductor DCR. In addition, product selection and installation practices will have increased importance as PDs approaching 100 W input power—conveyed by a single Ethernet cable—are introduced following publication of the forthcoming Institute of Electrical and Electronics Engineers (IEEE) Standard 802.3bt. The report also provides recommendations and next steps, which include plans for additional PoE cable energy losses testing with higher-power PDs to more fully explore the potential of PoE lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the Impact of Excluding the Submersion Exposure Route for Existing Superfund Radionuclide Screening Level Calculator Soil and Tap Water Models

The U.S. Environmental Protection Agency (EPA) provides initial data screening guidelines for radionuclide-contaminated Superfund sites using preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs). PRGs and DCCs are target concentration values based on acceptable excess lifetime cancer risk and annual dose limits, respectively. They are calculated for various environmental media that may be encountered by residential and worker land uses. PRGs and DCCs typically consist of multiple exposure routes. One of these routes is submersion, which is exposure to a gaseous or particulate radionuclide that is suspended in air. Currently, submersion is only included in air calculations. This study focused on determining whether factoring submersion into total PRG/DCC calculations for soil and tap water created a significant difference in the target concentrations. New equations for individual submersion PRGs/DCCs for each land use of interest for soil and tap water were developed. A wind-driven particulate emission factor and Andelman’s constant were used to model the amount of soil and vapor in the air from soil and household use of tap water, respectively. The submersion PRG/DCC was then included in the total PRG/DCC for each radionuclide, followed by a percent difference comparison of the old and new totals to quantify the impact of the change. For total soil PRGs/DCCs, with and without submersion, the difference was less than 1 percent; however, many of the tap water radionuclides analyzed – including multiple radon and polonium isotopes – showed as high as a 200 percent difference.This technical memorandum (TM) presents recommendations for updates to current EPA guidelines for initial data screens of radionuclide contaminated tap water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Fuel Cycle Cost Basis Report: Supporting Documents 2 Production Based Costing

The purpose of this section is to outline a method of cost analysis whereby a significantly better representation of “should achieve” costs may be attained for NOAK systems. Based on economists’ notions of producer theory, and grounded in the cost analysts’ and project managers’ tool called the Work Breakdown Structure (WBS), this section describes best practices in cost estimation. It then illustrates how the Code of Accounts (COA) structure, developed by the Economic Modeling Working Group (EMWG) of the Generation IV International Forum in “Cost Estimating Guidelines for Generation IV Nuclear Energy Systems [EMWG 2007] (hereafter “Gen IV Guidelines Document”), can be used to differentiate “should achieve” versus “did experience” costs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Update on Activities Related to the Library of Graphite Microstructures

This report provides an overview and update of the ongoing efforts to create a comprehensive library of microstructures for nuclear graphite and carbon-based materials under consideration for nuclear applications. The library includes data on microstructural characterization of unirradiated graphite materials, a guide to the techniques used to analyze graphite (which complements the ASME guidelines and ASTM standards), a summary of characterization data for neutron-irradiated or oxidized material, and a compendium of microstructural information for carbon-based materials. These efforts are being conducted at various length scales for the filler and binder phases in graphite to better understand graphite’s local structure and property relationships. This report is a follow-up to the previous milestone report titled Report on initial development of a database of nuclear graphite characteristics based on microstructural characterization, ORNL/TM/-2023/2992, published in July 2023.The effort to develop the library of microstructures supports the US Department of Energy Office of Advanced Reactor Technologies program objectives of aiding the material selection, licensing, management, and core assessments of a graphite core by documenting the unirradiated microstructure of relevant grades or characterizing the microstructure’s evolution under the reactor environment. Additionally, this project aims to provide (1) information and guidelines for the characterizing of graphite and (2) a protocol to assess a nuclear graphite grade.

36 MATERIALS SCIENCE↗

Secure Power Systems Professional Phase III Final Report: Recruiting, Selecting and Developing Secure Power Systems Professionals

With significant numbers of power system experts retiring and a continuing trend of increasing complexity in modern power systems, there is a need throughout the power industry for cybersecurity awareness and competence in tasks that previously had no cyber components. To address these challenges, the U.S. Department of Energy established the Secure Power Systems Professional (SPSP) project to develop resources for job definition and competency analysis along with tools to guide assessment and curriculum design and to help identify and develop required knowledge, skills, and abilities in technical and operational power systems cybersecurity. The major accomplishments in Phase III of the project, which were built upon foundations laid in the first two phases, were (a) development and fielding of a Recruitment Guide for Human Resources and Hiring Managers and a Guide to Developing SPSPs; (b) development of psychometrically validated job profiles for identified SPSP job roles; (c) development of behavioral interview guidelines that list competencies necessary to perform each job role; and (d) development of guidelines that aid in evaluating individual and team performance and that inform strategic planning for organizations in selection, development and retention of SPSP professionals. The outcomes of the project can be immediately applied by human resources professionals, recruiters and hiring managers to assist in the recruitment, selection, and training of SPSPs, as well as to identify needed skills to grow existing employees into SPSPs.

97 MATHEMATICS AND COMPUTING↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C

Drainage structures are used to capture stormwater runoff in streets and highways in urban environments. These drainage structures, which typically consist of catch basins with grates, inlets, or combination grates/inlets, collect stormwater runoff and discharge through buried conveyance systems. They are strategically placed for public safety in curb and gutter systems to provide efficient drainage of water from roadways and thus reduce the risk of hydroplaning. The performance of drainage structures is measured in terms of hydraulic efficiency, which is defined as the percentage of flow captured by the basin as compared to the total flow drainage to the structure. Understanding of the performance of these drainage structures helps designers properly space inlets to promote an economic design that ensures the safety of the traveling public. The current design methodology used to determine drainage structure follows guidelines established in the current Michigan Department of Transportation (MDOT) Drainage Manual (2006). The guidelines in the MDOT Drainage Manual were modeled after the Federal Highway Administration’s (FHWA) Hydraulic Engineering Circular 22 “Urban Drainage Design” (HEC-22). HEC-22 includes empirically derived equations to calculate the interception capacity of drainage structures for several commonly used grate configurations, such as the parallel bar, curved vane and tilt bar grates, which are based on a research study performed by Burgi et al. in the 1970s. MDOT uses several drainage structures to capture runoff that are detailed as Standard Plans. Many of these drainage structures utilize sinusoidal type grates that are not described in HEC-22. Physical modeling of these structures has been limited, posing the need to have them analyzed to verify their capture efficiency. Current MDOT practice is to assume a similar sized reticuline grate, as described in HEC-22, for capture efficiencies. Until recently, evaluating the hydraulic performance of drainage structures was limited to physical modeling in a hydraulics laboratory. With advances in engineering software and computing power, computational fluid dynamics (CFD) modeling has become a more cost-effective alternative. The Federal Highway Administration (FHWA) provides states the option to evaluate their drainage structures using CFD through the Transportation Pooled Fund Program. This study, “Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C,” was carried out using the pooled fund. MDOT’s Cover C was chosen as the first test candidate, given its similar sinusoidal pattern to other MDOT grates, but it is typically used for high-volume, higher speed applications. A similar version, Cover CX, is used on interstate highways but does not have traverse bars for bicycle safety. Additional grates may be considered for evaluation in the future.

42 ENGINEERING↗

Understanding and Tailoring Diffusion and Co-Adsorption Inside the Confined Pores of Metal-Organic Frameworks (Final Scientific/Technical Report for Award DE-SC0019902)

The aim of this program was to gain a fundamental understanding of the behavior of various guest molecules in nano-confined environments, such as metal organic frameworks (MOFs), using a combination of novel synthesis, ab initio modeling, and in situ characterization. Through this project, we developed a concise understanding of the mechanisms that control adsorption/desorption of gaseous molecules and their mixtures, leading to design/synthesis guidelines for MOFs with desired functionality. We further developed methods to disentangle kinetic from thermodynamic effects during adsorption, as well as to characterize the interactions at play. In the first funding cycle, the focus was on the unambiguously characterization of co-adsorption and diffusion of gasses/vapors and their mixtures. In the second funding cycle, the focus was on characterizing the effects of the nano-confinement on the kinetics and thermodynamics of adsorption processes inside MOFs, again with an emphasis on mixtures of gasses and vapors. The nano-confinement can tip the thermodynamic vs. kinetic balance, and current understanding and theory based on single-component analysis can lead to incorrect predictions for mixtures. This is of particular interest in real-world applications, where gasses/vapors are typically mixed, contain impurities, or are often exposed to humid conditions. Our main findings were: (i) within confined environments the adsorption behavior of mixed gasses/vapors can be drastically different from the “sum” of the corresponding single phases; (ii) co-adsorption is often competitive and detrimental to performance, but it can also be cooperative and beneficial; (iii) in some co-adsorbed gasses/vapors, molecules that are strongly bound in the single-component phase can be replaced by molecules that are nominally weaker bound (molecular exchange) due to guest-guest interactions that lower the kinetic barriers and favor the final adsorption state; (iv) kinetic and thermodynamic effects can be precisely controlled through pore-size engineering and synthesis; and, (v) kinetic effects can be identified and disentangled from thermodynamic effects during adsorption through a series of sequential and simultaneous gas loading measurements. The short-term goal of this program was the controlling and understanding of common MOF systems in real-world situations where gasses/vapors are mixed, which will have an important impact on industrial processes and applications from gas storage and sequestration to catalysis and sensors. The long-term goals include the development of theoretical and experimental methods for gaining a fundamental understanding of adsorption/reaction processes within MOFs, as well as new guidelines for synthesizing MOFs with tailored physical and chemical properties.

36 MATERIALS SCIENCE↗

Review of Life Cycle Cost Analysis Tools

Life cycle costing (LCC) is a vital aspect of decision-making in building retrofitting. It allows stakeholders to thoroughly assess all expenses involved throughout the lifespan of these retrofits, covering initial costs; ongoing operation, maintenance, and repair costs; and disposal costs of the system. The Federal Energy Management Program of the US Department of Energy has established clear guidelines for conducting LCC analysis, particularly for investments aimed at energy and water conservation, as well as renewable energy projects. These guidelines are detailed in the Code of Federal Regulations, 10 CFR 436, Subpart A, which outlines the methodology and procedure for LCC analysis (Department of Energy 1990). The National Institute of Standards and Technology (NIST) has developed the NIST Handbook 135 (Joshua Kneifel 2022) to standardize the process of LCC analysis within the building industry. Whereas the handbook is tailored to the needs of federal agencies, its principles and methodologies can be valuable for other organizations and industries interested in conducting life cycle costing analyses for their building projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hanford Site Bald Eagle Monitoring Report for Fiscal Year 2014

The Bald Eagle (Haliaeetus leucocephalus) plays an important predatory role in the ecosystem and also serves as a national symbol for the United States of America. In 2007, the U.S. Fish and Wildlife Service (USFWS) determined that the population of bald eagles in the lower 48 States had sufficiently recovered, so the species could be removed from the federal endangered and threatened species list. The State of Washington also down-listed Bald Eagles from threatened to sensitive. Federal laws including the Bald and Golden Eagle Protection Act of 1940 and the Migratory Bird Treaty Act of 1918 still provide protection for eagles, their nest trees, and communal night roosts. The National Bald Eagle Management Guidelines, produced by the U.S. Fish and Wildlife Service, provides monitoring and management guidance for Bald Eagles (USFWS 2007). The Department of Energy (DOE) Richland Operations Office has the Bald Eagle Management Plan for the Hanford Site, South-Central Washington (DOE 2013), which defines appropriate protection measures for nests and roost sites based on federal and state guidelines. Monitoring is essential to maintain current biological information about bald eagle abundance and distribution on the Hanford Site, to ensure compliance with protection regulations, and to inform future protection and management efforts.

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Bald Eagle Monitoring Report for Fiscal Year 2013

The Bald Eagle (Haliaeetus leucocephalus) plays an important predatory role in the ecosystem and also serves as a national symbol for the United States of America. In 2007 the U.S. Fish and Wildlife Service (USFWS) determined that the population of bald eagles in the lower 48 States had sufficiently recovered, so the species could be removed from the federal endangered and threatened species list. The State of Washington also down-listed Bald Eagles from threatened to sensitive. Federal laws including the Bald and Golden Eagle Protection Act of 1940 and the Migratory Bird Treaty Act of 1918 still provide protection for eagles, their nest trees, and communal night roosts. The National Bald Eagle Management Guidelines, produced by the U.S. Fish and Wildlife Service, provides monitoring and management guidance for Bald Eagles (USFWS 2007). The Department of Energy Richland Operations Office (DOE) has the Bald Eagle Management Plan for the Hanford Site, South-Central Washington (DOE 2009) that defines appropriate protection measures for nests and roost sites based on federal and state guidelines. Monitoring is essential to maintain current biological information about bald eagle abundance and distribution on the Hanford Site, to ensure compliance with protection regulations, and to inform future protection and management efforts.

54 ENVIRONMENTAL SCIENCES↗

Bald Eagle Monitoring Report for Fiscal Year 2012

The Bald Eagle (Haliaeetus leucocephalus) plays an important predatory role in the ecosystem and serves as a national symbol for the United States of America. In 2007 the U.S. Fish and Wildlife Service (USFWS) determined that the population of bald eagles in the lower 48 States had sufficiently recovered, so the species could be removed from the federal endangered and threatened species list. The State of Washington also down-listed Bald Eagles from threatened to sensitive. However, Federal laws including the Bald and Golden Eagle Protection Act of 1940 and the Migratory Bird Treaty Act of 1918 still provide protection for eagles, their nest trees, and communal night roosts. The U.S. Fish and Wildlife Service, The National Bald Eagle Management Guidelines (USFWS 2007), provides monitoring and management guidance for Bald Eagles. The U.S. Department of Energy (DOE), Richland Operations Office (RL) has a Hanford Site bald eagle management plan (DOE 2009) that defines appropriate protection measures for nests and roost sites based on federal and state guidelines. Monitoring is essential to maintain current biological information about bald eagle abundance and distribution on the Hanford Site, to ensure compliance with protection regulations, and to inform future protection and management efforts.

54 ENVIRONMENTAL SCIENCES↗

DETERMINATION OF CORROSION INHIBITOR CRITERIA FOR TYPE III/IIIA TANKS DURING SALT DISSOLUTION OPERATIONS INTERIM REPORT

Preparation of high level waste for vitrification involves in part the dissolution of salt cake from the carbon steel storage tanks. During dissolution, a point is reached in which the corrosion inhibitors, hydroxide and nitrite, are diluted below established guidelines, and nitrate stress corrosion cracking (SCC) is possible. Because the addition of inhibitors may be counterproductive to process efficiency and waste minimization, corrosion testing was initiated to revisit and possibly revise the guidelines for inhibitor limits. The bases for the work summarized in this status report are results from previously-completed phases of study. In the first two phases of study, several reduced-inhibitor levels were tested in HLW simulants with nitrate concentrations ranging from 4.5 M to 8.5 M. The first two phases of work determined, among other things, the reduced-inhibitor levels and solution chemistries in which heat-treated and non-heat-treated A537 carbon steel is susceptible to SCC, crevice corrosion, and pitting. The work covered in this current task both builds on and verifies the conclusions of the previous work. The current work involves testing of low levels of inhibitors in HLW simulants with 5.5 M to 8.5 M nitrate concentrations. Stressed U-bend specimens, both polarized and non-polarized, were tested. Non-polarized U-bend testing is ongoing, with the U-bends currently in test for 100 days. The purpose of the testing is to determine SCC susceptibility in the vapor space (VS) and liquid air interface (LAI) regions of the HLW tanks under conditions expected during salt dissolution, and also to verify previous accelerated testing. The simulated wastes being tested have nitrate concentrations of 5.5 M and 8.5 M and inhibitor levels of 0.01 M/0.01 M hydroxide/nitrite and 0.1 M/ 0.1 M hydroxide/nitrite. The open circuit potential measurements being monitored and the corrosion morphology of the U-bends are in agreement with results and observations of previous phases of work. No SCC has occurred in the first 100 days of testing. The LAI specimens experienced minor corrosion at the liquid line with corrosion products visible on the weld material and in the heat-affected zones on either side of the welds. The VS specimens are more evenly and slightly more corroded. Polarized U-bend testing is complete after approximately 80 days of testing. No SCC occurred, but the results are inconclusive due to a competing, unexpected galvanic corrosion mechanism that interfered in the last 50 days of testing. No cracking was indicated during the first month. The tests will be repeated in order to satisfy the original objective which was to determine the effect of grinding HLW tank welds and heat treating the tanks had on corrosion. Both the non-polarized and polarized U-bend tests will continue. Additionally, cyclic polarization (CP) testing will be performed to examine the effects of surface oxides on corrosion and the differences in corrosion susceptibility between welded and un-welded areas.

36 MATERIALS SCIENCE↗

Development of a Habitat Suitability Index Model for the Sage Sparrow on the Hanford Site

Mitigation threshold guidelines for the Hanford Site are based on habitat requirements of the sage sparrow (Amphispiza belli) and only apply to areas with a mature sagebrush (Artemisia tridentata) overstory and a native understory. The sage sparrow habitat requirements are based on literature values and are not specific to the Hanford Site. To refine these guidelines for the Site, a multi-year study was undertaken to quantify habitat characteristics of sage sparrow territories. These characteristics were then used to develop a habitat suitability index (HSI) model which can be used to estimate the habitat value of specific locations on the Site.

54 ENVIRONMENTAL SCIENCES↗

Toward a more rigorous application of margins and uncertainties within the nuclear weapons life cycle : a Sandia perspective.

This paper presents the conceptual framework that is being used to define quantification of margins and uncertainties (QMU) for application in the nuclear weapons (NW) work conducted at Sandia National Laboratories. The conceptual framework addresses the margins and uncertainties throughout the NW life cycle and includes the definition of terms related to QMU and to figures of merit. Potential applications of QMU consist of analyses based on physical data and on modeling and simulation. Appendix A provides general guidelines for addressing cases in which significant and relevant physical data are available for QMU analysis. Appendix B gives the specific guidance that was used to conduct QMU analyses in cycle 12 of the annual assessment process. Appendix C offers general guidelines for addressing cases in which appropriate models are available for use in QMU analysis. Appendix D contains an example that highlights the consequences of different treatments of uncertainty in model-based QMU analyses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Oxygen Handling and Cooling Options in High Temperature Electrolysis Plants

Idaho National Laboratory is working on a project to generate hydrogen by high temperature electrolysis (HTE). In such an HTE system, safety precautions need to be taken to handle high temperature oxygen at ~830°C. This report is aimed at addressing oxygen handling in a HTE plant.. Though oxygen itself is not flammable, most engineering material, including many gases and liquids, will burn in the presence of oxygen under some favorable physicochemical conditions. At present, an absolute set of rules does not exist that can cover all aspects of oxygen system design, material selection, and operating practices to avoid subtle hazards related to oxygen. Because most materials, including metals, will burn in an oxygen-enriched environment, hazards are always present when using oxygen. Most materials will ignite in an oxygen-enriched environment at a temperature lower than that in air, and once ignited, combustion rates are greater in the oxygen-enriched environment. Even many metals, if ignited, burn violently in an oxygen-enriched environment. However, these hazards do not preclude the operations and systems involving oxygen. Oxygen can be safely handled and used if all the materials in a system are not flammable in the end-use environment or if ignition sources are identified and controlled. In fact, the incidence of oxygen system fires is reported to be low with a probability of about one in a million. This report is a practical guideline and tutorial for the safe operation and handling of gaseous oxygen in high temperature electrolysis system. The intent is to provide safe, practical guidance that permits the accomplishment of experimental operations at INL, while being restrictive enough to prevent personnel endangerment and to provide reasonable facility protection. Adequate guidelines are provided to govern various aspects of oxygen handling associated with high temperature electrolysis system to generate hydrogen. The intent here is to present acceptable oxygen standards and practices for minimum safety requirements. A summary of operational hazards, along with oxygen safety and emergency procedures, are provided.

08 HYDROGEN↗

BENCHMARKING ORTEC ISOTOPIC MEASUREMENTS AND CALCULATIONS

This report represents a description of compiled benchmark tests conducted to probe and to demonstrate the extensive utility of the Ortec ISOTOPIC {gamma}-ray analysis computer program. The ISOTOPIC program performs analyses of {gamma}-ray spectra applied to specific acquisition configurations in order to apply finite-geometry correction factors and sample-matrix-container photon absorption correction factors. The analysis program provides an extensive set of preset acquisition configurations to which the user can add relevant parameters in order to build the geometry and absorption correction factors that the program determines from calculus and from nuclear g-ray absorption and scatter data. The Analytical Development Section field nuclear measurement group of the Savannah River National Laboratory uses the Ortec ISOTOPIC analysis program extensively for analyses of solid waste and process holdup applied to passive {gamma}-ray acquisitions. Frequently the results of these {gamma}-ray acquisitions and analyses are to determine compliance with facility criticality safety guidelines. Another use of results is to designate 55-gallon drum solid waste as qualified TRU waste3 or as low-level waste. Other examples of the application of the ISOTOPIC analysis technique to passive {gamma}-ray acquisitions include analyses of standard waste box items and unique solid waste configurations. In many passive {gamma}-ray acquisition circumstances the container and sample have sufficient density that the calculated energy-dependent transmission correction factors have intrinsic uncertainties in the range 15%-100%. This is frequently the case when assaying 55-gallon drums of solid waste with masses of up to 400 kg and when assaying solid waste in extensive unique containers. Often an accurate assay of the transuranic content of these containers is not required, but rather a good defensible designation as >100 nCi/g (TRU waste) or <100 nCi/g (low level solid waste) is required. In these cases the ISOTOPIC analysis program is especially valuable because it allows a rapid, defensible, reproducible analysis of radioactive content without tedious and repetitive experimental measurement of {gamma}-ray transmission through the sample and container at multiple photon energies. The ISOTOPIC analysis technique is also especially valuable in facility holdup measurements where the acquisition configuration does not fit the accepted generalized geometries where detector efficiencies have been solved exactly with good calculus. Generally in facility passive {gamma}-ray holdup measurements the acquisition geometry is only approximately reproducible, and the sample (object) is an extensive glovebox or HEPA filter component. In these cases accuracy of analyses is rarely possible, however demonstrating fissile Pu and U content within criticality safety guidelines yields valuable operating information. Demonstrating such content can be performed with broad assumptions and within broad factors (e.g. 2-8) of conservatism. The ISOTOPIC analysis program yields rapid defensible analyses of content within acceptable uncertainty and within acceptable conservatism without extensive repetitive experimental measurements. In addition to transmission correction determinations based on the mass and composition of objects, the ISOTOPIC program performs finite geometry corrections based on object shape and dimensions. These geometry corrections are based upon finite element summation to approximate exact closed form calculus. In this report we provide several benchmark comparisons to the same technique provided by the Canberra In Situ Object Counting System (ISOCS) and to the finite thickness calculations described by Russo in reference 10. This report describes the benchmark comparisons we have performed to demonstrate and to document that the ISOTOPIC analysis program yields the results we claim to our customers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Insecticide Exposures on Commercial Aircraft: A Literature Review and Screening Level Assessment

The objective of this project was to provide initial estimates of the relationship between insecticide use on passenger aircraft and exposure levels present in the cabin environment. The work was initially divided into three tasks including 1) a review of insecticide application practices in commercial aircraft, 2) exploratory measurements of insecticide concentrations in treated aircraft and 3) screening level exposure modeling. Task 1 gathered information that is needed to assess the time-concentration history of insecticides in the airline cabin. The literature review focused on application practices, information about the cabin environment and existing measurements of exposure concentrations following treatment. Information from the airlines was not available for estimating insecticide application rates in the U.S. domestic fleet or for understanding how frequently equipment rotate into domestic routes following insecticide treatment. However, the World Health Organization (WHO) recommends several methods for treating aircraft with insecticide. Although there is evidence that these WHO guidelines may not always be followed, and that practices vary by airline, destination, and/or applicator company, the guidelines in combination with information related to other indoor environments provides a plausible basis for estimating insecticide loading rates on aircraft. The review also found that while measurements of exposure concentrations following simulated aerosol applications are available, measurements following residual treatment of aircraft or applications in domestic aircraft are lacking. Task 2 focused on developing an approach to monitor exposure concentrations in aircraft using a combination of active and passive sampling methods. An existing active sampling approach was intended to provide data immediately following treatment while a passive sampler was developed to provide wider coverage of the fleet over longer sampling periods. The passive sampler, based on a thin-film polymer-coated glass design, was developed specifically for deployment in the airliner ventilation system for long-term unattended monitoring of insecticide loading in the aircraft. Because access was not available for either treated aircraft or treatment records during the course of this study, the development and calibration of the passive samplers was halted prior to completion. Continued development of a field ready passive sampler for insecticides in aircraft would require collaboration with the airline industry to finalize the method for deployment and calibration conditions for the sampler. The Task 3 screening level modeling assessment used a dynamic two-box mass balance model that includes treated surfaces and air to explore the time-concentration history of insecticides in the cabin. The model was parameterized using information gathered during the literature review and run for several different insecticide use scenarios. Chemical degradation or sequestration in the surface compartment and mass transfer from the surface to the air limit the rate at which insecticides are removed from the system. This rate limiting process can result in an accumulation of insecticide in the airliner cabin following repeated applications. The extent of accumulation is a function of the overall persistence of the chemical in the system and the amount of chemical applied during each treatment.

54 ENVIRONMENTAL SCIENCES↗