Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Three-dimensional FIB/EBSD characterization of irradiated HfAl{sub 3}-Al composite

A thermal neutron-absorbing composite comprised of 28.4 vol.% HfAl{sub 3} intermetallic particles in an Al matrix, developed for use in a conduction-cooled thermal neutron filter, will enable fast flux irradiation of materials and fuels in an existing pressurized water test reactor. In this paper, an EBSD-FIB characterization approach is used to observe the microstructural changes of the HfAl{sub 3}-Al composite in response to simulated long-term neutron irradiation. Using a focused ion beam (FIB), the sample was fabricated to 25 μm x 25 μm x 20 μm and mounted on a transmission electron microscopy (TEM) grid. A series of operations were carried out repeatedly on the sample's top surface to prepare it for scanning electron microscopy (SEM). First, a ∼ 100-nm layer was removed by high voltage FIB milling. Then, several cleaning passes were performed on the newly exposed surface using low voltage FIB milling to improve the SEM image quality. The surface was then scanned by Electron Backscattering Diffraction (EBSD) to obtain a two-dimensional image. After 50 to 100 two-dimensional images were collected, the images were stacked to reconstruct a three-dimensional model using DREAM.3D software. Two such reconstructed three dimensional models were obtained from samples of the original and post-irradiation HfAl{sub 3}-Al composite, from which the most significant microstructural change caused by neutron irradiation appears to be the size reduction of both HfAl{sub 3} and Al grains. Possible causes include thermal expansion and related thermal strain from thermal neutron capture. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design, fabrication and testing of a CFA for use in the solar power satellite

A crossed field amplifier was designed to meet the performance objectives of high signal to noise ratio, an efficiency of 85%, a CW microwave power output of 5-8 kW, and a frequency of 2450 MHz. The signal to noise ratio achieved was better than 69 db/MHz in a 2000 MHz band centered on the carrier. High circuit efficiency of 97% and a sharp knee on voltage current characteristic were achieved. The basic problem of maintaining good transfer of heat to the external radiator while providing for adequate connections to input and output was solved. Maximum efficiency achieved was 70.5% and gain and power level were below objectives. An investigation of causes of reduced performance indicated the poor field pattern in the cathode anode interaction area of the tube was a major cause.

Brown, W. C.↗

A Three–Dimensional Nanoscale View of Electrocatalyst Degradation in Hydrogen Fuel Cells

The loss of platinum (Pt) electrochemically active surface area (ECSA) is a critical degradation mode that often becomes a limiting factor for heavy-duty proton exchange membrane fuel cell vehicles. High surface area carbon supports have been shown to improve Pt dispersion and limit detrimental ionomer-electrocatalyst interactions due to their large interior pore volume. Here, in this work, using automated scanning transmission electron tomography, the degradation of nanoparticles located on the interior versus exterior surfaces of the carbon support is compared following a catalyst-specific accelerated stress test (AST) of 90,000 voltage cycles between 0.6 V to 0.95 V. The results reveal a notable increase in median particle size for both interior and exterior Pt catalyst particles, with a slightly higher increase in particle size distribution and loss of specific surface area for the particles located on the exterior carbon surface. The fraction of Pt nanoparticles that reside within the interior of the carbon support also increased following the AST test, accompanied by evidence of an increase in average carbon mesopore size. Here, the results shed light on the degradation mechanisms affecting electrochemical properties and the enhanced particle accessibility at lower relative humidity.

08 HYDROGEN↗

Impedance of an intense plasma-cathode electron source for tokamak startup

In this study, an impedance model is formulated and tested for the ~1kV, ~1kA/cm 2 , arc-plasma cathode electron source used for local helicity injection tokamak startup. A double layer sheath is established between the high-density arc plasma (n arc ≈ 10 21 m -3 ) within the electron source, and the less dense external tokamak edge plasma (n edge ≈ 10 18 m -3 ) into which current is injected at the applied injector voltage, V inj . Experiments on the Pegasus spherical tokamak show the injected current, I inj , increases with V inj according to the standard double layer scaling I inj ~ V inj 3/2 at low current and transitions to I inj ~ V inj 1/2 at high currents. In this high current regime, sheath expansion and/or space charge neutralization impose limits on the beam density n b ~ I inj /V inj 1/2 . For low tokamak edge density n edge and high I inj , the inferred beam density n b is consistent with the requirement n b ≤ n edge imposed by space-charge neutralization of the beam in the tokamak edge plasma. At sufficient edge density, n b ~ n arc is observed, consistent with a limit to n b imposed by expansion of the double layer sheath. These results suggest that n arc is a viable control actuator for the source impedance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed fiber-optic sensing in a subscale high-temperature superconducting dipole magnet

High-temperature superconductors, such as REBa2Cu3O7−x (REBCO, RE = rare earth), are becoming pivotal for high-field magnet technology for future circular colliders and compact fusion reactors. The U.S. Magnet Development Program, in collaboration with industry, is developing REBCO magnet technology using round conductors consisting of multiple REBCO tapes. For these multi-tape cables, traditional instrumentation, such as voltage taps and resistive strain gauges, become insufficient to help measure and understand the performance-limiting factors in these model magnets. Distributed fiber-optic sensing (DFOS) is a potential solution to address this challenge. Although DFOS is well established for various applications, measuring temperature and strain in high-temperature superconducting magnets is in its infancy. Here we report the detailed implementation and test results of DFOS based on Rayleigh scattering in a subscale canted cosθ (CCT) dipole magnet using high-temperature superconducting CORC® wires. We co-wound optical fibers in each layer of the CCT magnet and compared different types of commercial fibers and mold-release agents to reduce the power attenuation in the fibers. The DFOS allowed us to measure mechanical deformation and temperature along the conductor during tests at 77 and 4.2 K. The measured strain agreed quantitively with a finite-element mechanical model of the subscale magnet. Our results indicate that DFOS can effectively identify locations of strain and temperature changes, offering unique insight into magnet performance that can advance our understanding and development of the REBCO magnet technology for high-energy physics and fusion applications.

Luo, Linqing↗

Model predictive control of KSTAR equilibrium parameters enabled by TRANSP

Due to the complex behavior of tokamak plasmas and the importance of optimizing performance while avoiding instabilities and machine limits, plasma control algorithms are becoming increasingly dependent on sophisticated model-based control approaches. It is anticipated that the use of integrated modeling codes in the model-based control design process will reduce the amount of experimental time needed to implement new control algorithms by facilitating development of control-oriented models and enabling higher-fidelity closed-loop simulations. In this work, a reduced model is developed from a series of TRANSP simulations and is used to develop a model predictive control (MPC) algorithm for controlling important equilibrium parameters in KSTAR [1] discharges. The control algorithm uses the KSTAR neutral beam injection system and the target plasma current and plasma boundary as actuators, and optimizes the plasma stored energy, loop voltage, and internal inductance while avoiding constraints that could lead to disruptions. Higher fidelity testing of the control algorithm is performed using a flexible framework for enabling external processes to actively control plasma parameters in TRANSP simulations. Furthermore, closed-loop simulations demonstrate the ability of the control algorithm to respond to disturbances in density and confinement, handle actuator failures, and move the discharge to high non-inductive fraction conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

Comparative Investigation of Current-Source Inverters using SiC Discrete Devices and Power Modules

The purpose of this paper is to investigate the impact of the SiC device packages on the commutation performance characteristics of current-source inverters (CSIs). The parasitic components in the CSI current commutation loop between the two-phase legs and output capacitors have a significant impact on the high-frequency performance of the SiC devices. To meet the elevated current requirements of high-power CSIs, it is often necessary to connect multiple discrete devices in parallel which increases the current commutation loop length. The selection of compact high-power SiC MOSFET and Schottky diode modules instead of discrete devices can be highly desirable to reduce the loop inductance and improve the system performance and power density. Two CSI benchtop prototype units, one with SiC discrete devices and the other with power modules, have been designed and tested, and the performances of the two CSIs are compared. The CSI with SiC power modules significantly reduces the inverter volume and lowers the parasitic inductance by 60% and the voltage ripple amplitude by 20% compared to the CSI unit with discrete devices.

42 ENGINEERING↗

Effect of Aluminum Oxide on the Performance of Ionic Liquid-Based Aluminum–Air Battery

The aluminum–air (or oxygen) battery has received intense attention in the past because of its excellent benefits such as low cost and high energy density, but due to the challenging issues such as hydrogen evolution and inactive oxide film formation on the Al surface, it could not be fully applied. In this study, 1-Ethyl 3-Methyl Imidazolium Chloride ([EmIm]Cl) and aluminum chloride (AlCl3) are applied to resolve the aforementioned issues. Ex situ component-level and in situ cell-level open circuit voltage (OCV) tests combined with the physics-based model analyses were conducted to investigate the electrochemical reaction behaviors of the Al–air cell. Especially, the effect of aluminum oxide formation on the anode- and cathode-side reactions were analyzed in detail. The oxide film formed at the Al surface strongly was found to significantly impede the electrochemical reaction at the surface, and the film growth was controlled by decreasing the surface tension by aggressive anions. In the cathode side, the aluminum oxide precipitated in the porous cathode electrode was found to decrease the porous reaction area and block reactant access into the reaction sites. The effects of O2 solubility in the electrolyte, initial porosity and thickness of the porous electrode are compared in detailed, and optimal thickness is suggested.

25 ENERGY STORAGE↗

DC responsivity of proximity effect bridges to high frequency radiation

The effect of microwave radiation on the dc current-voltage characteristic of proximity effect bridges has been studied at frequencies of 10, 35, and 90 GHz. The properties of bridges fabricated in layered films of Nb and Ta are reported. The fraction, epsilon, of the incident radiant power absorbed by the bridge is measured calorimetrically, permitting determination of the intrinsic responsivity (volts per watt of power absorbed when operated in a current-biased mode). In the test geometry employed, epsilon is typically about .0001 for a 0.1 ohm Nb-Ta bridge, and increases roughly linearly with dc junction resistance. Broad-band responsivity is generally independent of incident power, increases with increasing critical current (decreasing temperature), and decreases with increasing frequency. Peak responsivities achieved to date are about 100,000 V/W (absorbed) at 10 GHz and about 100 V/W (absorbed) at 90 GHz.

Hauser, M. G.↗

A Geophysical Flow Experiment in a Compressible Critical Fluid

The first objective of this experiment is to build an experimental system in which, in analogy to a geophysical system, a compressible fluid in a spherical annulus becomes radially stratified in density through an A.C. electric field. When this density gradient is demonstrated, the system will be augmented so that the fluid can be driven by heating and rotation and tested in preparation for a microgravity experiment. This apparatus consists of a spherical capacitor filled with critical fluid in a temperature controlled environment. To make the fluid critical, the apparatus will be operated near the critical pressure, critical density, and critical temperature of the fluid. This will result in a highly compressible fluid because of the properties of the fluid near its critical point. A high voltage A.C. source applied across the capacitor will create a spherically symmetric central force because of the dielectric properties of the fluid in an electric field gradient. This central force will induce a spherically symmetric density gradient that is analogous to a geophysical fluid system. To generate such a density gradient the system must be small (approx. 1 inch diameter). This small cell will also be capable of driving the critical fluid by heating and rotation. Since a spherically symmetric density gradient can only be made in microgravity, another small cell, of the same geometry, will be built that uses incompressible fluid. The driving of the fluid by rotation and heating in these small cells will be developed. The resulting instabilities from the driving in these two systems will then be studied. The second objective is to study the pattern forming instabilities (bifurcations) resulting from the well controlled experimental conditions in the critical fluid cell. This experiment will come close to producing conditions that are geophysically similar and will be studied as the driving parameters are changed.

Hegseth, John↗

A VSC-HVDC-Assisted Black-Start Strategy in Bulk Power Systems a Case Study in San Diego

With the worldwide growth in deploying high-voltage direct current (HVDC) transmission systems, their ability to facilitate black-start (BS) restoration has been a research topic of interest. In this context, voltage source converter (VSC)-HVDC is regarded as a BS resource, and this paper proposes a VSC-HVDC-assisted parallel BS restoration strategy in bulk power systems. The proposed strategy consists of two stages: 1) determination of the VSC and generator startup sequence and 2) load restoration simulation. In the first stage, the entire blackout system is sectionalized into multiple subsystems. Each subsystem includes a VSC-HVDC station or traditional BS unit, it independently determines its generator startup timeline and the energization timelines for buses and lines. The second stage involves load restoration, conceptualized as a modified unit commitment problem, with the timelines established in the first stage work as critical inputs. The proposed BS restoration strategy is tested on the San Diego power system to simulate the 2011 Southwest blackout. The simulation results validate the effectiveness of using VSC-HVDC links as a BS resource which not only speeds up the restoration process but also reduces both energy and economic losses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]↗

Atomic-scale constituting stable interface for improved LiNi 0.6 Mn 0.2 Co 0.2 O 2 cathodes of lithium-ion batteries

Ascribed to their higher capacity and lower cost compared to conventional LiCoO 2 , the Ni-rich layered LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) is now considered as one promising cathode for lithium-ion batteries (LIBs). However, it still suffers from some evident performance degradation, especially under high cutoff voltages (i.e., >4.3 V versus Li/Li + ). The performance degradation typically is exhibited as capacity fading and voltage drop, mainly originating from an instable interface between the NMC622 and electrolyte as well as the evolution of the NMC structure. To improve the interfacial and structural stability of NMC cathodes, herein we deposited an ultrathin layer of Al 2 O 3 coatings (<5 nm) conformally over NMC622 composite electrodes directly using atomic layer deposition (ALD). It was found that, under different upper cutoff voltages (4.3, 4.5, and 4.7 V), the ALD Al 2 O 3 coatings enable enhanced performance of NMC622 cathodes with better cyclability and higher capacity. Particularly, the beneficial effects of the ALD Al 2 O 3 coatings are more remarkable at higher upper cutoff voltages (4.5 and 4.7 V). Furthermore, the ALD coatings can significantly improve the rate capability of NMC622. To this end, we utilized a suite of characterization tools and performed a series of electrochemical tests to clarify the effects of the ALD Al 2 O 3 coatings. This study revealed that the beneficial effects of the Al 2 O 3 ALD coatings are multiple: (i) serving as an artificial layer of solid electrolyte interphase to mitigate undesirable interfacial reactions; (ii) acting as a physical barrier to inhibit metal dissolution of NMC; and (iii) forming a reinforced networked overcoating to boost the mechanical integrity of NMC cathodes. This study is favorable for designing high-performance NMC cathodes.

25 ENERGY STORAGE↗

Degradation in Ni-Rich LiNi 1– x – y Mn x Co y O 2 /Graphite Batteries: Impact of Charge Voltage and Ni Content

Ni-rich LiNi 1– x–y Mn x CoyO 2 (NMC) materials are attractive as cathodes for Li-ion batteries due to their high energy density and low Co content. However, these materials may display poor electrochemical reversibility relating to structural and interfacial instabilities. The influence of Ni content and level of delithiation during charge on degradation mechanisms and relevance to electrochemical cycling behavior are probed for LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) and LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathode materials in a full cell configuration under two upper voltage limits (4.1 and 4.3 V). The combined use of dQ/dV analysis of electrochemical voltage profiles, operando XRD, and postcycling scanning electron microscopy (SEM) measurements indicates that a major contributor to capacity fade is the large anisotropic volume change from an H2 $\leftrightarrows$ H3 phase transition and associated mechanical degradation particularly for NMC811. Notably, transition metal dissolution and deposition on the negative electrode are found to correlate with the structural changes occurring in the cathode under high voltage charge. X-ray photoelectron spectroscopy (XPS) analyses of the cycled cathodes reveal a more organic-rich cathode–electrolyte interphase (CEI) when cycling to 4.3 V with lower relative amounts of LiF. Surface reconstruction is not a significant factor under these cycling conditions as determined by soft X-ray absorption spectroscopy (sXAS) analysis. The results emphasize the opportunity to match the electrochemical test parameters with the specific NMC active material to mitigate degradation and extend cycle life.

36 MATERIALS SCIENCE↗

American-Made Geothermal Geophone Prize: Ultra-High Temperature Seismic Tool for Geothermal Wells Summary Report

This work was conducted in support of the American Made Geothermal Prize. The following data summary report presents the testing conducted at Sandia National Labs to validate the performance of the Ultra-High Temperature Seismic Tool for Geothermal Wells. The goal of the testing was to measure the sensitivity of the device to seismic vibrations and reliability of the instrument at elevated temperatures. To this end, two tests were conducted: 1) Ambient Temperature Seismic Testing, which measured the response of the tool to a sweep of frequencies from 1 to 1000 Hz, and 2) Elevated Temperature Survivability Testing which measured the voltage response of the device at 225°C over a month-long testing window. The details of the testing methodology and summary of the tests are presented herein.

15 GEOTHERMAL ENERGY↗

Corrosion testing of candidates for the alkaline fuel cell cathode

It is desirable to employ a corrosion screening test for catalyst or support candidates for the fuel cell cathode before entering upon optimization of the candidate or of the catalytic electrode. To this end, corrosion test electrodes, intended for complete immersion and maximum wetting, have been made with 30 to 40 vol. pct Teflon; with perovskites this is about 10 to 15 pct. The candidates were synthesized by methods intended for single-phase product without special emphasis on high surface area, although the substances tested were no coarser than 2 m squared/g. A typical loading was 25 mg/cm sq of the pure substance, usually on gold screen, a few mm squared of which were left bare for contacting. Contact to the gold lead wire was made by welding with a micro-torch or a spot-welder. Corrosion testing consisted of obtaining current-voltage data under flowing inert gas in the potential region for reduction of O2. The electrode was immersed in 30 pct KOH. Observations were made at 20 C and 80 C, and the results compared with data from gold standards. Results with some perovskites, pyrochlores, spinels, and interstitial compounds will be discussed.

Singer, Joseph↗

Design and Testing of a Small Inductive Pulsed Plasma Thruster

The design and testing of a small inductive pulsed plasma thruster (IPPT), shown in Fig. 1 with all the major subsystems required for a thruster of this kind are described. Thrust measurements and imaging of the device operated in rep-rated mode are presented to quantify the performance envelope of the device. The small IPPT described in this paper was designed to serve as a test-bed for the pulsed gas-valves and solid-state switches required for a IPPTs. A modular design approach was used to permit future modifications and upgrades. The thruster consists of the following sub-systems: a) a multi-turn, spiral-wound acceleration coil (27 cm o.d., 10 cm i.d.) driven by a 10 microFarad capacitor and switched with a high-voltage thyristor, b) a fast pulsed gas-valve, and c.) a glow-discharge pre-ionizer (PI) circuit. The acceleration-coil circuit may be operated at voltages up to 4 kV (the thyristor limit is 4.5 kV). The device may be operated at rep-rates up to 30 Hz with the present gas-valve. Thrust measurements and imaging of the device operated in rep-rated mode will be presented. The pre-ionizer consists of a 0.3 microFarad capacitor charged to 4 kV and connected to two annular stainless-steel electrodes bounding the area of the coil-face. The 4 kV potential is held across them and when the gas is puffed in over the coil, the PI circuit is completed, and a plasma is formed. Even at the less than optimal base-pressure in the chamber (approximately 5 × 10(exp −4) torr), the PI held-off the applied voltage, and only discharged upon command. For a capacitor charge of 2 kV the peak coil current is 4.1 kA, and during this pulse a very bright discharge (much brighter than from the PI alone) was observed (see Fig. 2). Interestingly, for discharges at this charge voltage the PI was not required as the current rise rate, dI/dt, of the coil itself was sufficient to ionize the gas.

Martin, Adam K.↗