Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Stereochemical Control of Water Transport Properties in Thiol‐yne Polymers

Barrier polymers underpin almost every commercial sector, yet the needs of several emerging areas remain unmet by commercially‐available materials, including temporary orthopedic implants, transient health monitors, neural implants, and other long‐term implants. The ability to tune polymer composition independently of polymer structure positions thiol‐yne click chemistry as a promising platform to serve these emerging technologies. Here, this work describes the differences in the hierarchical structure of stoichiometrically identical materials which differ only in the proportion of the cis versus trans backbone alkene stereochemistry. Varying the isomer content in this way directs different temperature and rate dependent crystallization behavior, which affords control over micron‐scale structure. This investigation focuses on how these stereochemical features affect the water vapor permeation process by several methods and develops an understanding of how this unique structural regularity improves barrier performance relative to a commercially available water barrier polymer, poly(ethylene terephthalate).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

3D‐Printed Carbon Electrodes for Neurotransmitter Detection

Abstract Implantable neural microsensors have significantly advanced neuroscience research, but the geometry of most probes is limited by the fabrication methods. Therefore, new methods are needed for batch‐manufacturing with high reproducibility. Herein, a novel method is developed using two‐photon nanolithography followed by pyrolysis for fabrication of free‐standing microelectrodes with a carbon electroactive surface. 3D‐printed spherical and conical electrodes were characterized with slow scan cyclic voltammetry (CV). With fast‐scan CV, the electrodes showed low dopamine LODs of 11±1 n m (sphere) and 10±2 n m (cone), high sensitivity to multiple neurochemicals, and high reproducibility. Spherical microelectrodes were used to detect dopamine in a brain slice and in vivo, demonstrating they are robust enough for tissue implantation. This work is the first demonstration of 3D‐printing of free‐standing carbon electrodes; and the method is promising for batch fabrication of customized, implantable neural sensors.

Yang, Cheng↗

3D‐Printed Carbon Electrodes for Neurotransmitter Detection

Abstract Implantable neural microsensors have significantly advanced neuroscience research, but the geometry of most probes is limited by the fabrication methods. Therefore, new methods are needed for batch‐manufacturing with high reproducibility. Herein, a novel method is developed using two‐photon nanolithography followed by pyrolysis for fabrication of free‐standing microelectrodes with a carbon electroactive surface. 3D‐printed spherical and conical electrodes were characterized with slow scan cyclic voltammetry (CV). With fast‐scan CV, the electrodes showed low dopamine LODs of 11±1 n m (sphere) and 10±2 n m (cone), high sensitivity to multiple neurochemicals, and high reproducibility. Spherical microelectrodes were used to detect dopamine in a brain slice and in vivo, demonstrating they are robust enough for tissue implantation. This work is the first demonstration of 3D‐printing of free‐standing carbon electrodes; and the method is promising for batch fabrication of customized, implantable neural sensors.

Yang, Cheng↗

Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement

Following X-ray exposure, radiographers receive immediate feedback on detector exposure in the form of the exposure index (EI). To identify whether radiographers are meeting manufacturer-recommended EI (MREI) ranges for routine chest, abdomen and pelvis X-ray examinations under a variety of conditions and to examine factors affecting the EI. Data on 5000 adult X-ray examinations including the following variables were collected: examination parameters, EI values, patient gender, date of birth, date and time of examination, grid usage and the presence of implant or prosthesis. Descriptive statistics were used to summarize each data set and the Mann–Whitney U test was used to determine significant differences, with P < 0.05 indicating significance for all tests. Most examinations demonstrated EI values that were outside the MREI ranges, with significantly higher median EI values recorded for female patient radiographs than those for male patients for all manufacturers, indicating higher detector exposures for all units except for Philips digital radiography (DR), where increased EI values indicate lower exposure (P = 0.01). Median EI values for out of hours radiography were also significantly higher compared with normal working hours for all technologies (P ≤ 0.02). Significantly higher median EI values were demonstrated for Philips DR chest X-rays without as compared to those with the employment of a grid (P = 0.03), while significantly lower median EI values were recorded for Carestream Health computed radiography (CR) chest X-rays when an implant or prosthesis was present (P = 0.02). Non-adherence to MREIs has been demonstrated with EI value discrepancies being dependent on patient gender, time/day of exposure, grid usage and the presence of an implant or prosthesis. Retrospective evaluation of EI databases is a valuable tool to assess the need of quality improvement in routine DR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the oxidation states and structural stability of the Ce analogue of brannerite

The Ce-containing analogue of brannerite (ie, UTi2O6) was previously considered to be stoichiometric (ie, CeTi2O6); however, it has recently been determined that the material is O deficient. This oxygen-deficient material has been suggested to be charged balanced by the presence of a minor concentration of Ce3+ or by the A-site being cation deficient with the Ce oxidation state being 4+. A variety of Ti-containing oxides (including brannerite) have been investigated as potential nuclear wasteforms, and it is necessary to understand the electronic structure of a proposed nuclear wasteform material as well as how the structure responds to radiation from incorporated waste elements. The radiation resistance of a material can be simulated by ion implantation. The objective of this study was to confirm the Ce oxidation state in the cation- and oxygen-deficient material (ie, Ce0.94Ti2O6 - δ) and to determine how radiation damage affects this material. X-ray photoelectron spectroscopy (XPS) and X-ray absorption near-edge spectroscopy were used to study Ce0.94Ti2O6 - δ before and after being implanted with 2 MeV Au- ions. Analysis of the Ce 3d XPS spectra from the as-synthesized samples by using a previously developed fitting method has unequivocally shown that Ce adopts both 4+ (major) and 3+ (minor) oxidation states, which was confirmed by examination of magnetic susceptibility data. Analysis of XPS and X-ray absorption near-edge spectroscopy spectra from ion-implanted materials showed that both Ce and Ti were reduced because of radiation damage and that the local coordination environments of the cations are greatly affected by radiation damage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-Dimensional Imaging of Lipids and Metabolites in Tissues by Nanospray Desorption Electrospray Ionization Mass Spectrometry

Abstract Three-dimensional (3D) imaging of tissue sections is a new frontier in mass spectrometry imaging (MSI). Here we report on fast 3D imaging of lipids and metabolites associated with mouse uterine decidual cells and embryo at the implantation site on day 6 of pregnancy. 2D imaging of 16-20 serial tissue sections deposited on the same glass slide was performed using nanospray desorption electrospray ionization (nano-DESI) – an ambient ionization technique that enables sensitive localized analysis of analytes on surfaces without special sample pre-treatment. In this proof-of-principle study, nano-DESI was coupled to a high-resolution Q-Exactive instrument operated at high repetition rate of >5 Hz with moderate mass resolution of 35,000 (m/Δm at m/z 200), which enabled acquisition of the entire 3D image with a spatial resolution of ~150 μm in less than 4.5 hours. The results demonstrate localization of acetylcholine in the primary decidual zone (PDZ) of the implantation site throughout the depth of the tissue examined, indicating an important role of this signaling molecule in decidualization. Choline and phosphocholine – metabolites associated with cell growth – are enhanced in the PDZ and abundant in other cellular regions of the implantation site. Very different 3D distributions were obtained for fatty acids (FA), oleic acid and linoleic acid (FA 18:1 and FA 18:2), differing only by one double bond. Localization of FA 18:2 in the PDZ indicates its important role in decidualization while FA 18:1 is distributed more evenly throughout the tissue. In contrast, several lysophosphatidylcholines (LPC) observed in this study show donut-like distributions with localization around the PDZ. Complementary distributions with minimal overlap were observed for LPC 18:0 and FA 18:2 while the 3D image of the potential precursor phosphatidylcholine (PC 36:2) showed a significant overlap with both LPC 18:0 and FA 18:2.

Environmental Molecular Sciences Laboratory↗

Covered Biodegradable Stent: New Therapeutic Option for the Management of Esophageal Perforation or Anastomotic Leak

Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38-74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during a balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5-6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into 'normal-sized' (stent-to-artery-ratio < 1.4, n = 12) and 'oversized' (stent-to-artery-ratio {>=} 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotid duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of cardiac {sup 123}I-mIBG imaging in predicting arrhythmic events in stable chronic heart failure patients with an ICD

Background: Despite therapeutic improvement, the prognosis of chronic heart failure (CHF) remains unfavorable partly due to arrhythmia and sudden cardiac death (SCD). This prospective study evaluated myocardial {sup 123}I-meta-iodobenzylguanidine ({sup 123}I-mIBG) scintigraphy as a predictor of arrhythmic events (AE) in CHF patients. Methods: 170 CHF patients referred for implantable cardioverter-defibrillator (ICD) implantation for both primary and secondary prevention were enrolled. All patients underwent planar and SPECT imaging. Early and late heart-to-mediastinum (H/M) ratio, {sup 123}I-mIBG washout (WO), early and late summed SPECT scores were calculated The primary endpoint was an AE: sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate ICD therapy or SCD. The secondary endpoint was appropriate ICD therapy. Results: During a median follow-up of 23.3 months, 69 patients experienced an AE. Early summed score (ESS) was the only independent predictor of AE [HR 1.023 (1.003-1.043)]. Focussing on only patients with an ICD for primary prevention, ESS was the only independent predictor of AE [HR 1.028 (1.007-1.050)]. {sup 123}I-mIBG-derived parameters failed to be independent predictors of appropriate ICD therapy. However there was a “bell-shaped” relation between {sup 123}I-mIBG scintigraphy-derived parameters and AE and appropriate ICD therapy, i.e., those with intermediate {sup 123}I-mIBG abnormalities tended to be at higher risk of events. Conclusion: Although SPECT {sup 123}I-mIBG scintigraphy was associated with AE in CHF patients with ICD implantation for primary and secondary prevention, no association was found between {sup 123}I-mIBG scintigraphy-derived parameters and appropriate ICD therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Grain boundary softening from stress assisted helium cavity coalescence in ultrafine-grained tungsten

The formation of helium cavities in coarse-grained materials produces hardening proportional to the number density and size of the cavities and due to the interaction of dislocations with intragranular helium defects. In nanostructured metals containing a high density of interfacial sinks, preferential cavity formation in the grain boundaries instead produces softening that is often attributed to enhanced interfacial plasticity. Here, employing two grades of ultrafine-grained tungsten, we explore this effect using targeted implantation studies to map cavity evolution as a function of the irradiation conditions and quantify its impact on the mechanical response through nanoindentation. Softening is reported at implantation temperatures above the threshold for preferential grain boundary cavity formation but at a sufficiently low fluence prior to the growth of intragranular cavities. Collective changes in the mean cavity size, density, and morphology beneath a residual impression on an implanted surface indicate that cavity coalescence accompanied the reduction in hardness. Complementary atomistic simulations demonstrate that, in tungsten grain structures exhibiting softening, grain boundary bubble coalescence is driven by stress concentrations that further act to localize strain in the grain boundaries through cooperative deformation processes involving local atomic shuffling and sliding, dislocation emission, and even the nucleation of unstable twinning events.

36 MATERIALS SCIENCE↗

Effects of alloying elements on the elastic properties of bcc Ti-X alloys from first-principles calculations

Titanium alloys are great implant materials due to their mechanical properties and biocompatibility. However, a large difference in Young’s modulus between bone (~10–40 GPa) and common implant mate-rials (ie. Ti-6Al-4V alloy ~ 110 GPa) leads to stress shielding and possible implant failure. Here, the present work predicts the single crystal elastic stiffness coefficients (c ij ’s) for five binary systems with the body centered cubic lattice of Ti-X (X = Mo, Nb, Ta, Zr, Sn) using first-principles calculations based on Density Functional Theory. In addition, the polycrystalline aggregate properties of bulk modulus, shear modulus, Young’s modulus, and Poisson ratio are calculated. It is shown that the lower Young’s modulus of these Ti-alloys stems from the unstable bcc Ti with a negative value of (c 11 –c 12 ). The data gathered from these efforts are compared with available experimental and other first-principles results in the literature, which set a foundation to design biocompatible Ti alloys for desired elastic properties.

36 MATERIALS SCIENCE↗

Role of Intra- or Periprostatic Calcifications in Image-Guided Radiotherapy for Prostate Cancer

Purpose: Image-guided radiotherapy (IGRT) allows more precise localization of the prostate, thus minimizing errors resulting from organ motion and set-up during treatment of prostate cancer. Using megavoltage cone-beam computed tomography (MVCBCT), references such as bones, the prostate itself or implanted fiducial markers can be used as surrogates to correct patient positioning immediately before each treatment fraction. However, the use of fiducials requires an invasive procedure and may increase costs. We aimed to assess whether intra- or periprostatic calcifications (IPC) could be used as natural fiducials. Methods and Materials: Data on patients treated with IGRT for prostate cancer with clearly visible IPC and implanted fiducials in both planning CT and MVCBCT images were reviewed. IPC were classified as central when inside the prostate and peripheral when within the planning target volume. Daily deviations in lateral, longitudinal, and vertical directions from baseline positioning using fiducials and using IPC were compared. Results: A total of 287 MVCBCT images were obtained and analyzed from 10 patients. The mean {+-} standard deviation daily deviation (mm) in the lateral, longitudinal, and vertical coordinates were 0.55 {+-} 3.11, 0.58 {+-} 3.45, and -0.54 {+-} 4.03, respectively, for fiducials, and 0.72 {+-} 3.22, 0.63 {+-} 3.58, and -0.69 {+-} 4.26, for IPC. The p values for comparisons (fiducials vs. IPC) were 0.003, 0.653, and 0.078 for lateral, longitudinal, and vertical coordinates, respectively. When cases with central IPC were analyzed (n = 7), no significant difference was found in such comparisons. Central IPC and fiducials exhibited a similar pattern of displacement during treatment, with equal values for daily displacements in the three directions for more than 90% of measurements. Conclusions: Our data suggest that centrally located IPC may be used as natural fiducials for treatment positioning during IGRT for prostate cancer, with potential reductions in the risks and costs associated with fiducial implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Irradiation on Brain Vasculature Using an In Situ Tumor Model

Purpose: Damage to normal tissue is a limiting factor in clinical radiotherapy (RT). We tested the hypothesis that the presence of tumor alters the response of normal tissues to irradiation using a rat in situ brain tumor model. Methods and Materials: Intravital microscopy was used with a rat cranial window to assess the in situ effect of rat C6 glioma on peritumoral tissue with and without RT. The RT regimen included 40 Gy at 8 Gy/day starting Day 5 after tumor implant. Endpoints included blood-brain barrier permeability, clearance index, leukocyte-endothelial interactions and staining for vascular endothelial growth factor (VEGF) glial fibrillary acidic protein, and apoptosis. To characterize the system response to RT, animal survival and tumor surface area and volume were measured. Sham experiments were performed on similar animals implanted with basement membrane matrix absent of tumor cells. Results: The presence of tumor alone increases permeability but has little effect on leukocyte-endothelial interactions and astrogliosis. Radiation alone increases tissue permeability, leukocyte-endothelial interactions, and astrogliosis. The highest levels of permeability and cell adhesion were seen in the model that combined tumor and irradiation; however, the presence of tumor appeared to reduce the volume of rolling leukocytes. Unirradiated tumor and peritumoral tissue had poor clearance. Irradiated tumor and peritumoral tissue had a similar clearance index to irradiated and unirradiated sham-implanted animals. Radiation reduces the presence of VEGF in peritumoral normal tissues but did not affect the amount of apoptosis in the normal tissue. Apoptosis was identified in the tumor tissue with and without radiation. Conclusions: We developed a novel approach to demonstrate that the presence of the tumor in a rat intracranial model alters the response of normal tissues to irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Body Mass Index on Intrafraction Prostate Displacement Monitored by Real-Time Electromagnetic Tracking

Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a 'beam on' tag were used in the analysis. There were 21 obese patients, with BMI {>=}30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 {+-} 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 {+-} 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI {>=}30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗