Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

On the importance of nuclear quantum motions in near edge x-ray absorption fine structure (NEXAFS) spectroscopy of molecules

We report the effects of sampling nuclear quantum motion with path integral molecular dynamics (PIMD) on calculations of the nitrogen K-edge spectra of two isolated organic molecules. S-triazine, a prototypical aromatic molecule occupying primarily its vibrational ground state at room temperature, exhibits substantially improved spectral agreement when nuclear quantum effects are included via PIMD, as compared to the spectra obtained from either a single fixed-nuclei based calculation or from a series of configurations extracted from a classical molecular dynamics trajectory. Nuclear quantum dynamics can accurately explain the intrinsic broadening of certain features. Glycine, the simplest amino acid, is problematic due to large spectral variations associated with multiple energetically accessible conformations at the experimental temperature. This work highlights the sensitivity of NEXAFS to quantum nuclear motions in molecules, and the necessity of accurately sampling such quantum motion when simulating their NEXAFS spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct SERDS sensing of molecular biomarkers in plants under field conditions

Molecular biomarkers such as microRNAs (miRNAs) play important roles in regulating various developmental processes in plants. Understanding these pathways will help bioengineer designing organisms for efficient biomass accumulation. Current methods for RNA analysis require sample extraction and multi-step sample analysis, hindering work in field studies. Recent work in the incorporation of nanomaterials for plant bioengineering research is leading the way of an agri-tech revolution. As an example, surface-enhanced Raman scattering (SERS)–based sensors can be used to monitor RNA in vivo. However, the use of SERS in the field has been limited due to issues with observing Raman signal over complex background. To this end, shifted-excitation Raman difference spectroscopy (SERDS) offers an effective solution to extract the SERS signal from high background based on a physical approach. In this manuscript, we report the first application of SERDS on SERS sensors. We investigated this technique on SERS sensor developed for the detection of a microRNA biomarker, miR858. We tested the technique on in vitro samples and validated the technique by detecting the presence of exogenous miR858 in plants directly under ambient light in a growth chamber. The possibility of moving the detection of nucleic acid targets outside the constraints of laboratory setting enables numerous important bioengineering applications. Finally, such applications can revolutionize biofuel production and agri-tech through the use of nanotechnology-based monitoring of plant growth, plant health, and exposure to pollution and pathogens.

09 BIOMASS FUELS↗

X-ray laser–induced electron dynamics observed by femtosecond diffraction from nanocrystals of Buckminsterfullerene

X-ray free-electron lasers (XFELs) deliver x-ray pulses with a coherent flux that is approximately eight orders of magnitude greater than that available from a modern third-generation synchrotron source. The power density of an XFEL pulse may be so high that it can modify the electronic properties of a sample on a femtosecond time scale. Exploration of the interaction of intense coherent x-ray pulses and matter is both of intrinsic scientific interest and of critical importance to the interpretation of experiments that probe the structures of materials using high-brightness femtosecond XFEL pulses. We report observations of the diffraction of extremely intense 32-fs nanofocused x-ray pulses by a powder sample of crystalline C 60 . We find that the diffraction pattern at the highest available incident power significantly differs from the one obtained using either third-generation synchrotron sources or XFEL sources operating at low output power and does not correspond to the diffraction pattern expected from any known phase of crystalline C 60 . We interpret these data as evidence of a long-range, coherent dynamic electronic distortion that is driven by the interaction of the periodic array of C 60 molecular targets with intense x-ray pulses of femtosecond duration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opinion: Making the Most of Colour Rendition Research

After decades of debate, new methods for characterizing color rendition have been formalized, providing an improved system of tools to aid technology developers and lighting specifiers. Solid-state lighting, previously burdened by legacy measures based on outdated science, is positioned to take advantage of these new tools to provide tailored, efficient lighting that better meets the needs of specific architectural lighting applications. This transition requires new guidance, however, presenting an opportunity for researchers. There are several key methodological considerations specific to experiments investigating color rendition that will help build a base of guidance that can be widely applied. The importance of these ideas mostly stems from new knowledge gained in the last five years, but their origins date back much further. 1.The spectral power distribution must be adequately varied to stress the measure(s) of color rendition being evaluated. Often, this means varying the gamut shape—the pattern of shift across different hues—to probe weaknesses of hue-averaged characterizations, avoiding misleading conclusions resulting from limited variation in the stimuli. 2.Evaluating the role of chromaticity on color quality evaluations requires careful accommodation of chromatic adaptation to prevent a centering bias. Asking for delayed responses may be insufficient if chromaticity changes are apparent to participants, just as side-by-side viewing of different chromaticities may not produce results that can be reliably applied in the field. It is also critical that color rendition and chromaticity conditions are varied independently. 3.The stimulus being viewed is the interaction of light and objects’ spectral reflectances. This interaction should be quantified in order to assess how derived guidelines will apply measures using standardized color sample sets. Although light source characterizations are typically used to model responses, the objects and their presentation may strongly influence evaluations. 4.Context is important. Many factors—some investigated, others hypothesized—can influence subjective evaluations of color quality, including illuminance level, type of scene, object familiarity, color composition, viewing duration, and viewer traits. Although their influence on research results is unavoidable, the effects of these contextual factors must be carefully considered in developing guidance. Appropriate experimental design can often mitigate negative consequences arising from these considerations. At a minimum, it is crucial to understand how each of these considerations can influence experimental outcomes, as well as the interpretation and application of the results in practice. Consulting other experts prior to conducting an experiment can help ensure appropriate, up-to-date research methods will be used, so that the results will be novel and useful—and not rejected during peer review. There is an interesting feedback loop: technology development provides new research tools, which allow for refined research methods and new results that lead to more technology development. It is time to make a concerted, collective effort to improve color rendition research so that the full potential of solid-state lighting and new characterization methods can be realized, ensuring that high-efficiency, high-utility, high-appeal lighting systems become standard.

Royer, Michael P.↗

On the possibility of using X-ray Compton scattering to study magnetoelectrical properties of crystals

The possibility of using X-ray Compton scattering to reveal antisymmetric components of the electron momentum density, as a fingerprint of magnetoelectric sample properties, is investigated experimentally and theoretically by studying the polar ferromagnet GaFeO{sub 3}. This paper discusses the possibility of using Compton scattering – an inelastic X-ray scattering process that yields a projection of the electron momentum density – to probe magnetoelectrical properties. It is shown that an antisymmetric component of the momentum density is a unique fingerprint of such time- and parity-odd physics. It is argued that polar ferromagnets are ideal candidates to demonstrate this phenomenon and the first experimental results are shown, on a single-domain crystal of GaFeO{sub 3}. The measured antisymmetric Compton profile is very small (≃ 10{sup −5} of the symmetric part) and of the same order of magnitude as the statistical errors. Relativistic first-principles simulations of the antisymmetric Compton profile are presented and it is shown that, while the effect is indeed predicted by theory, and scales with the size of the valence spin–orbit interaction, its magnitude is significantly overestimated. The paper outlines some important constraints on the properties of the antisymmetric Compton profile arising from the underlying crystallographic symmetry of the sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sequencing at sea: challenges and experiences in Ion Torrent PGM sequencing during the 2013 Southern Line Islands Research Expedition

Genomics and metagenomics have revolutionized our understanding of marine microbial ecology and the importance of microbes in global geochemical cycles. However, the process of DNA sequencing has always been an abstract extension of the research expedition, completed once the samples were returned to the laboratory. During the 2013 Southern Line Islands Research Expedition, we started the first effort to bring next generation sequencing to some of the most remote locations on our planet. We successfully sequenced twenty six marine microbial genomes, and two marine microbial metagenomes using the Ion Torrent PGM platform on the Merchant Yacht Hanse Explorer. Onboard sequence assembly, annotation, and analysis enabled us to investigate the role of the microbes in the coral reef ecology of these islands and atolls. This analysis identified phosphonate as an important phosphorous source for microbes growing in the Line Islands and reinforced the importance of Lserine in marine microbial ecosystems. Sequencing in the field allowed us to propose hypotheses and conduct experiments and further sampling based on the sequences generated. By eliminating the delay between sampling and sequencing, we enhanced the productivity of the research expedition. By overcoming the hurdles associated with sequencing on a boat in the middle of the Pacific Ocean we proved the flexibility of the sequencing, annotation, and analysis pipelines.

59 BASIC BIOLOGICAL SCIENCES↗

The Metallicity Distribution Functions of SEGUE G and K dwarfs: Constraints for Disk Chemical Evolution and Formation

Using the G and K dwarfs from the Sloan Extension for Galactic Understanding and Exploration (SEGUE) survey, we determine the metallicity distributions of cool stars in the Milky Way disk system. This portion of the Sloan Digital Sky Survey (SDSS) contains spectra for approximately 41,500 G and 23,800 K dwarfs, a significantly larger sample, both numerically and spatially, than previous spectroscopic analyses. Comparison of these two spectral types, and their variation in metallicity with respect to Galactic position, provides important guidance for models of the formation and chemical evolution of the Milky Way's thick-disk component. SEGUE has a well-defined, quantitative target-selection algorithm, based on ugriz photometry and proper motions; this allows us to adjust our spectroscopic sample such that it accurately represents the underlying Milky Way populations.Combining atmospheric parameters, determined by an optimized version of the SEGUE Stellar Parameter Pipeline, with various isochrones, we calculate the distance to each star, accurate to {approx}12%. We then quantify the variation in metallicity with respect to spatial position from the Galactic center (R) and the plane of the Galaxy (|Z|). Our unbiased observations of G and K dwarfs provide valuable constraints for chemical and dynamical Galaxy evolution models, with particular utility for thin- and thick-disk formation theory. Although our uncertainties in the radial metallicity gradient are large, we are consistent with the results from Cheng et al., estimating a negative gradient below |Z| of 1 kpc that flattens above this height. Both spectral types also exhibit a consistent decrease in [Fe/H] with increasing |Z|, approximately -0.3 dex/kpc. Comparison with the sample of Lee et al., which distinguishes between the thin and thick disk using [{alpha}/Fe], suggests that this gradient reflects the transition in G and K dwarfs from a thin-disk dominated sample at small |Z| to a sample consisting primarily of thick-disk stars above |Z| of 1 kpc. We compare our distributions to those of two different models of the Galaxy: the population synthesis model TRILEGAL (Girardi et al. 2004) and that of Schoenrich & Binney which simulates chemical and dynamical evolution. Both models show little change in [Fe/H] with respect to |Z| and are unable to replicate the metallicity distributions we observe above |Z| of 0.5 kpc. This result is not surprising, as the existing chemical constraints on Galaxy models are limited to the solar neighborhood, which is thin-disk dominated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Capture and Transmission Measurements of 54 Fe at the RPI LINAC

54 Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54 Fe sample in the keV energy region. 54 Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54 Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C 6 D 6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54 Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54 Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54 Fe up to roughly 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptation of existing facilities to isentropic compression experiments

We demonstrate that the established pulsed power infrastructure at the National High Magnetic Field Laboratory - Pulsed Field Facility (NHMFL-PFF) at the Los Alamos National Laboratory can be adapted to obtain high quality isentropic compression experiment (ICE) data on materials in extreme conditions of dynamic high pressure. Experiments utilized a single-turn magnet pulsed power system at the NHMFL-PFF that was originally designed to measure actinide samples in extremes of high magnetic field (to 300 Tesla). A simple modification to the single-turn magnet has converted it to a fast turnaround dynamic high pressure measurement system. This paper details the work done including important background details that indicate that much more can be accomplished with optimization of the load characteristics in terms of ultimate peak pressures. To match the rise time of the NHMFL capacitor bank ({approx}2 {mu}s versus {approx}0.5 {mu}s for the Sandia Z-machine) the sample dimensions can be relatively large, i.e., up to 5 mm thickness. The maximum stresses are {approx}50GPa (0.5 Mbar) at the maximum bank voltage (60 kV) and higher pressures may be possible if the sample is tamped. For the design and predictions of performance of the NHMFL-ICE experiment it is important to have good predictive models. A SPICE code simulation was chosen to model all aspects of the experiment, electrical and physical. To this end, accurate dynamic load models were developed to simulate the compression and expansion of the dynamic load at high pressures using shock physics principles. A series experiments have been performed which demonstrated the feasibility of the NHMFL-ICE technique. The results will be shown and discussed. The NHMFL-ICE technique is an excellent method for measuring equations of state (EOS) at megabar pressures. Because a complete EOS can be obtained in one experiment from zero to the peak pressure, and because many shots can be fired in one day, the technique promises to provide high quality EOS data at relatively low cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous multiplexed materials characterization using a high-precision hard X-ray micro-slit array

Here, the needs both for increased experimental throughput and for in operando characterization of functional materials under increasingly realistic experimental conditions have emerged as major challenges across the whole of crystallography. A novel measurement scheme that allows multiplexed simultaneous measurements from multiple nearby sample volumes is presented. This new approach enables better measurement statistics or direct probing of heterogeneous structure, dynamics or elemental composition. To illustrate, the submicrometer precision that optical lithography provides has been exploited to create a multiplexed form of ultra-small-angle scattering based X-ray photon correlation spectroscopy (USAXS-XPCS) using micro-slit arrays fabricated by photolithography. Multiplexed USAXS-XPCS is applied to follow the equilibrium dynamics of a simple colloidal suspension. While the dependence of the relaxation time on momentum transfer, and its relationship with the diffusion constant and the static structure factor, follow previous findings, this measurements-in-parallel approach reduces the statistical uncertainties of this photon-starved technique to below those associated with the instrument resolution. More importantly, we note the potential of the multiplexed scheme to elucidate the response of different components of a heterogeneous sample under identical experimental conditions in simultaneous measurements. Lastly, in the context of the X-ray synchrotron community, this scheme is, in principle, applicable to all in-line synchrotron techniques. Indeed, it has the potential to open a new paradigm for in operando characterization of heterogeneous functional materials, a situation that will be even further enhanced by the ongoing development of multi-bend achromat storage ring designs as the next evolution of large-scale X-ray synchrotron facilities around the world.

36 MATERIALS SCIENCE↗

On the dynamics and kinematics of two-fluid-phase flow in porous media

A model formulated in terms of both conservation and kinematic equations for phases and interfaces in two-fluid-phase flow in a porous medium system is summarized. Macroscale kinematic equations are derived as extensions of averaging theorems and do not rely on conservation principles. Models based on both conservation and kinematic equations can describe multiphase flow with varying fidelity.When only phase-based equations are considered, a model similar in form to the traditional model for two-fluid-phase flow results. When interface conservation and kinematic equations are also included, a novel formulation results that naturally includes evolution equations that express dynamic changes in fluid saturations, pressures, the capillary pressure, and the fluid-fluid interfacial area density in a two-fluid-system. This dynamic equation set is unique to this work, and the importance of the modeled physics is shown through both microfluidic experiments and high-resolution lattice Boltzmann simulations. The validation work shows that the relaxation of interface distribution and shape toward an equilibrium state is a slow process relativeto the time scale typically allowed for a system to approach an apparent equilibrium state based upon observations of fluid saturations and external pressure measurements. Consequently, most pressure-saturation data intended to denote an equilibrium state are likely a sampling from a dynamic system under-going changes of interfacial curvatures that are not typically monitored. The results confirm the importance of kinematic analysis in combination with conservation equations for faithful modeling of system physics.

54 ENVIRONMENTAL SCIENCES↗

A Comparison of "Total Dust" and Inhalable Personal Sampling for Beryllium Exposure

In 2009, the American Conference of Governmental Industrial Hygienists (ACGIH) reduced the Beryllium (Be) 8-hr Time Weighted Average Threshold Limit Value (TLV-TWA) from 2.0 μg/m 3 to 0.05 μg/m 3 with an inhalable 'I' designation in accordance with ACGIH's particle size-selective criterion for inhalable mass. Currently, per the Department of Energy (DOE) requirements, the Lawrence Livermore National Laboratory (LLNL) is following the Occupational Health and Safety Administration (OSHA) Permissible Exposure Limit (PEL) of 2.0 μg/m 3 as an 8-hr TWA, which is also the 2005 ACGIH TLV-TWA, and an Action Level (AL) of 0.2 μg/m 3 and sampling is performed using the 37mm (total dust) sampling method. Since DOE is considering adopting the newer 2009 TLV guidelines, the goal of this study was to determine if the current method of sampling using the 37mm (total dust) sampler would produce results that are comparable to what would be measured using the IOM (inhalable) sampler specific to the application of high energy explosive work at LLNL's remote experimental test facility at Site 300. Side-by-side personal sampling using the two samplers was performed over an approximately two-week period during chamber re-entry and cleanup procedures following detonation of an explosive assembly containing Beryllium (Be). The average ratio of personal sampling results for the IOM (inhalable) vs. 37-mm (total dust) sampler was 1.1:1 with a P-value of 0.62, indicating that there was no statistically significant difference in the performance of the two samplers. Therefore, for the type of activity monitored during this study, the 37-mm sampling cassette would be considered a suitable alternative to the IOM sampler for collecting inhalable particulate matter, which is important given the many practical and economic advantages that it presents. However, similar comparison studies would be necessary for this conclusion to be applied to other types of activities, where earlier studies have shown that the IOM sampler tends to collect higher concentrations of Be compared to the 37-mm cassette, which could complicate compliance with what is already an extremely low exposure limit.

99 GENERAL AND MISCELLANEOUS↗

Controllable synthesis of nickel dendritic crystals induced by magnetic field

We demonstrated in this paper a simple and easy method for the preparation of dendritic nickel crystals in an external magnetic field in boiling ethylene glycol (EG) solution. The structural features and morphology of the sample were investigated using powder X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The values of saturation magnetization (M{sub s}) and coercivity (H{sub c}) of the dendritic crystals characterized by using a vibrating sample magnetometer (VSM) are 170.3 emu g{sup -1} and 50.7 Oe, respectively. It was clear that the external magnetic field was the most important factor for controlling the morphology of the product.

36 MATERIALS SCIENCE↗

Corium stratification test using intermediate products of degraded core materials in severe accident of BWR

Two series of corium stratification tests using samples including intermediate products (B{sub 4}C-Fe alloy, Fe-Zr alloy) in BWR severe accidents were performed to investigate the influence of initial chemical composition. Chemical features of intermediate products of degraded core materials in severe accidents are considered to change depend upon oxygen potential in the atmosphere and temperature of the products in accordance with the accident progression and the features are highly important for evaluating the relocation and stratification behavior of fuel debris, especially for boron distribution in fuel debris. The initial compositions of samples were determined based on the results of our previous control blade and channel box degradation tests. The present results indicate that the U concentration in the metallic layer largely depends on the oxygen potential in the atmosphere and the apparent red-ox reaction rate between UO{sub 2} and Zr is mitigated when the typical intermediate product B{sub 4}C-Fe alloy coexists with UO{sub 2} and Zr. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct measurement of shear properties of microfibers

As novel fibers with enhanced mechanical properties continue to be synthesized and developed, the ability to easily and accurately characterize these materials becomes increasingly important. Here we present a design for an inexpensive tabletop instrument to measure shear modulus (G) and other longitudinal shear properties of a micrometer-sized monofilament fiber sample, such as nonlinearities and hysteresis. This automated system applies twist to the sample and measures the resulting torque using a sensitive optical detector that tracks a torsion reference. The accuracy of the instrument was verified by measuring G for high purity copper and tungsten fibers, for which G is well known. Two industrially important fibers, IM7 carbon fiber and Kevlar{sup ®} 119, were also characterized with this system and were found to have G = 16.5 ± 2.1 and 2.42 ± 0.32 GPa, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE SL2S GALAXY-SCALE LENS SAMPLE. III. LENS MODELS, SURFACE PHOTOMETRY, AND STELLAR MASSES FOR THE FINAL SAMPLE

We present Hubble Space Telescope (HST) imaging data and Canada-France-Hawaii Telescope (CFHT) near-infrared ground-based images for the final sample of 56 candidate galaxy-scale lenses uncovered in the CFHT Legacy Survey as part of the Strong Lensing in the Legacy Survey project. The new images are used to perform lens modeling, measure surface photometry, and estimate stellar masses of the deflector early-type galaxies (ETGs). Lens modeling is performed on the HST images (or CFHT when HST is not available) by fitting the spatially extended light distribution of the lensed features assuming a singular isothermal ellipsoid mass profile and by reconstructing the intrinsic source light distribution on a pixelized grid. Based on the analysis of systematic uncertainties and comparison with inference based on different methods, we estimate that our Einstein radii are accurate to ∼3%. HST imaging provides a much higher success rate in confirming gravitational lenses and measuring their Einstein radii than CFHT imaging does. Lens modeling with ground-based images, however, when successful, yields Einstein radius measurements that are competitive with space-based images. Information from the lens models is used together with spectroscopic information from companion Paper IV to classify the systems, resulting in a final sample of 39 confirmed (grade A) lenses and 17 promising candidates (grade B,C). This represents an increase of half an order of magnitude in sample size with respect to the sample of confirmed lenses studied in Papers I and II. The Einstein radii of the confirmed lenses in our sample span the range 5-15 kpc and are typically larger than those of other surveys, probing the mass in regions where the dark matter contribution is more important. Stellar masses are in the range 10{sup 11}-10{sup 12} M{sub ☉}, covering the range of massive ETGs. The redshifts of the main deflector span a range 0.3 ≤ z{sub d} ≤ 0.8, which nicely complements low-redshift samples like the Sloan Lens ACS survey and thus provides an excellent sample for the study of the cosmic evolution of the mass distribution of ETGs over the second half of the history of the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Mercury speciation comparison. BrooksApplied Laboratories and Eurofins Frontier Global Sciences

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences (FGS), Inc. in Bothell, WA on behalf of the Savannah River Remediation (SRR) Mercury Program Team. These samples were analyzed for seven species including: total mercury, dissolved mercury, inorganic mercury ((Hg(I) and Hg(II)), elemental mercury, methylmercury, ethylmercury, and dimethylmercury, with an eighth species, particulate mercury, calculated from the difference between total and dissolved mercury after subtracting the elemental mercury. The species fraction of total mercury measured has ranged broadly from a low of 32% to a high of 146%, though the vast majority of samples have been <100%. This can be expected since one is summing multiple values that each have at least a ± 20% measurement uncertainty. Two liquid waste tanks particularly important to understanding the distribution of mercury species in the Savannah River Site (SRS) Tank Farm were selected for a round robin analysis by Eurofins FGS and BrooksApplied Laboratories (BAL). The analyses conducted by BAL on the Tank 22 and 38 samples and their agreement with those obtained from Eurofins FGS for total mercury, dissolved mercury, methylmercury, ethylmercury, and dimethylmercury provide a strong degree of confidence in these species measurements

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inorganic characterization of switchgrass biomass using laser-induced breakdown spectroscopy

The inorganic characterization of 74 samples of switchgrass using laser-induced breakdown spectroscopy (LIBS) was undertaken. Determination of ash and inorganic elements content in biomass materials is vital for feedstock screening for bioconversion processes. Hierarchical models using principal component analysis (PCA) and partial least square analysis (PLS) were used to determine the presence of specific elemental micronutrients that are important in determining plant health for robust biomass production. LIBS uses a 532 nm laser with 45 mJ of laser power to excite the samples of switchgrass plant material and the emission of all the elements present in the plant samples were recorded in single spectra with a wide wavelength range of 200–800 nm. The results were compared to the laboratory standard technique, e.g., ICP-OES technique, to determine the true values for major micronutrients such as, silicon (Si), potassium (K), calcium (Ca), magnesium (Mg), phosphorus (P), and sulfur (S). Overall, our objectives were: 1) To determine the spectral features of switchgrass containing different amounts of these elements and 2) To examine the viability of this technique for determining the quality of the feedstock in terms of its inorganic composition. Cross-validation results showed that the broad-based model developed is promising for inorganics prediction in switchgrass. The LIBS validation prediction for the micronutrient elements mentioned here have been obtained. The regression coefficients for Si, were obtained to be 0.995, 0.994 for calibration and validation respectively, in case of Ca the regression coefficients were, 0.994 and 0.992 for calibration and validation. Similarly, in the case of Mg and K these were calculated to be 0.992 and 0.985, and 0.994 and 0.993 respectively. The regression coefficients are not as good as those for the elements mentioned, in case of the two elements S and P. They are 0.957, and 0.878, and 0.952 and 0.894 respectively for calibration, validation for the two elements. This demonstrates that LIBS-based techniques are inherently well suited for diverse environmental applications. Furthermore, LIBS along with PLS model can show capability in determining the viability of switchgrass as a biomass in the production of biofuels and survivability of switchgrass in processes associated with climate change. LIBS can help determining which switchgrass would be appropriate for a specific conversion process that favors low ash content overall or low value of specific inorganics.

59 BASIC BIOLOGICAL SCIENCES↗