Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated circuits.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Superconducting qubits in a flip-chip architecture

Flip-chip architectures have recently enabled significant scaling-up of multi-qubit circuits and have been used to assemble hybrid quantum systems that combine different substrates, for example, for quantum acoustics experiments. The standard flip-chip method uses superconducting galvanic connections between two substrates, typically implemented using sophisticated indium wafer-bonding systems, which give highly reliable and temperature-cyclable assemblies, but are expensive, somewhat inflexible in design, and require robust substrates that can sustain the large compressive forces required to cold-weld the indium bonds. A much simpler method is to assemble dies using very low-force contacts and air-dried adhesives, although this does not provide a galvanic contact between the dies. In this work, we demonstrate that the latter technique can be used to reliably couple superconducting qubit circuits, in which the qubits are on separate dies, without the need for a galvanic connection. We demonstrate full vector qubit control of each qubit on each of the two dies, with high-fidelity single-shot readout, and further demonstrate entanglement-generating excitation swaps as well as benchmark a controlled-Z entangling gate between the two qubits on the two dies. This exemplifies a simple and inexpensive assembly method for two-plus-one-dimensional quantum circuit integration that supports the use of delicate or unusually shaped substrates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗

Photonic circuits for laser stabilization with integrated ultra-high Q and Brillouin laser resonators

The integration of stabilized lasers, sources that generate spectrally pure light, will provide compact, low-cost solutions for applications including quantum information sciences, precision navigation and timing, metrology, and high-capacity fiber communications. We report a significant advancement in this field, demonstrating stabilization of an integrated waveguide Brillouin laser to an integrated waveguide reference cavity, where both resonators are fabricated using the same CMOS-compatible integration platform. We demonstrate reduction of the free running Brillouin laser linewidth to a 292 Hz integral linewidth and carrier stabilization to a 4.9 × 10 –13 fractional frequency at 8 ms reaching the cavity-intrinsic thermorefractive noise limit for frequencies down to 80 Hz. We achieve this level of performance using a pair of 56.4 x 10 6 quality factor Si 3 N 4 waveguide ring-resonators that reduce the high-frequency noise by the nonlinear Brillouin process and the low-frequency noise by Pound–Drever–Hall locking to the ultra-low loss resonator. These results represent an important step toward integrated stabilized lasers with reduced sensitivity to environmental disturbances for atomic, molecular, and optical physics (AMO), quantum information processing and sensing, and other precision scientific, sensing, and communications applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency combs in optically injected terahertz ring quantum cascade lasers

Quantum cascade lasers (QCLs) have emerged as promising candidates for generating chip-scale frequency combs in mid-infrared and terahertz wavelengths. In this work, we demonstrate frequency comb formation in ring terahertz QCLs using the injection of light from a distributed feedback (DFB) laser. The DFB design frequency is chosen to match the modes of the ring cavity (near 3.3 THz), and light from the DFB is injected into the ring QCL via a bus waveguide. By controlling the power and frequency of the optical injection, we show that combs can be selectively formed and controlled in the ring cavity. Numerical modeling suggests that this comb is primarily frequency-modulated in character, with the injection serving to trigger comb formation. We also show that the ring can be used as a filter to control the output of the DFB QCL, potentially being of interest in terahertz photonic integrated circuits. Our work demonstrates that waveguide couplers are a compelling approach for injecting and extracting radiation from ring terahertz combs and offer exciting possibilities for the generation of new comb states in terahertz, such as frequency-modulated waves, solitons, and more.

47 OTHER INSTRUMENTATION↗

Vacuum deposition of χ(2) nonlinear organic single crystal films on silicon

Integrating second order nonlinear (χ(2)) optical materials on chip is an ongoing challenge for Si photonics. Noncentrosymmetric molecular crystals have the potential to deliver high χ(2) nonlinearity with good thermal stability, but so far have been limited to growth from solution or the melt, which are both difficult to control and scale up in manufacturing. Here, we show that large (>100 μm) single crystal domains of the nonlinear molecule 2-[3-(4-hydroxystyryl)-5,5-dimethylcyclohex-2-enylidene] malononitrile (OH1) can be grown monolithically on either glass or Si via vacuum evaporation, followed by a short thermal annealing step. The crystallites are tens of nanometer thick and exhibit strong second harmonic generation with their primary χ(2) tensor component lying predominantly in plane. Remarkably, we find that a single domain can grow uninterrupted through nearby channels etched on a Si wafer, which may provide a path to integrate OH1 on Si or Si3N4 waveguides for a broad range of χ(2)-based photonic integrated circuit functionality.

Physics↗

Perspectives of active Si photonics devices for data communication and optical sensing

Si photonics has made rapid progress in research and commercialization in the past two decades. While it started with electronic–photonic integration on Si to overcome the interconnect bottleneck in data communications, Si photonics has now greatly expanded into optical sensing, light detection and ranging (LiDAR), optical computing, and microwave/RF photonics applications. From an applied physics point of view, this perspective discusses novel materials and integration schemes of active Si photonics devices for a broad range of applications in data communications, spectrally extended complementary metal–oxide–semiconductor (CMOS) image sensing, as well as 3D imaging for LiDAR systems. We also present a brief outlook of future synergy between Si photonic integrated circuits and Si CMOS image sensors toward ultrahigh capacity optical I/O, ultrafast imaging systems, and ultrahigh sensitivity lab-on-chip molecular biosensing.

electronic band structure↗

A new regime of nanoscale thermal transport: Collective diffusion increases dissipation efficiency

Understanding thermal transport from nanoscale heat sources is important for a fundamental description of energy flow in materials, as well as for many technological applications including thermal management in nanoelectronics and optoelectronics, thermoelectric devices, nanoenhanced photovoltaics, and nanoparticle-mediated thermal therapies. Thermal transport at the nanoscale is fundamentally different from that at the macroscale and is determined by the distribution of carrier mean free paths and energy dispersion in a material, the length scales of the heat sources, and the distance over which heat is transported. Past work has shown that Fourier’s law for heat conduction dramatically overpredicts the rate of heat dissipation from heat sources with dimensions smaller than the mean free path of the dominant heat-carrying phonons. In this work, we uncover a new regime of nanoscale thermal transport that dominates when the separation between nanoscale heat sources is small compared with the dominant phonon mean free paths. Surprisingly, the interaction of phonons originating from neighboring heat sources enables more efficient diffusive-like heat dissipation, even from nanoscale heat sources much smaller than the dominant phonon mean free paths. This finding suggests that thermal management in nanoscale systems including integrated circuits might not be as challenging as previously projected. In conclusion, we demonstrate a unique capability to extract differential conductivity as a function of phonon mean free path in materials, allowing the first (to our knowledge) experimental validation of predictions from the recently developed first-principles calculations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multi-Element Germanium Detectors with Integrated Readouts

In this study, we have developed a series of monolithic multi-element germanium detectors coupled with custom developed CMOS application specific integrated circuit (ASIC) for readout. Several strip detectors with element counts ranging from 64 to 384 were developed and are currently used at the National Synchrotron Light Source II in Brookhaven National Laboratory and the Advanced Photon Source in Argonne National Laboratory. Lastly, the detectors are photon counting and are used at high-energy diffraction and energy dispersive diffraction beamlines.

47 OTHER INSTRUMENTATION↗

Automated identification and indexing of dislocations in crystal interfaces

Here, we present a computational method for identifying partial and interfacial dislocations in atomistic models of crystals with defects. Our automated algorithm is based on a discrete Burgers circuit integral over the elastic displacement field and is not limited to specific lattices or dislocation types. Dislocations in grain boundaries and other interfaces are identified by mapping atomic bonds from the dislocated interface to an ideal template configuration of the coherent interface to reveal incompatible displacements induced by dislocations and to determine their Burgers vectors. Additionally, the algorithm generates a continuous line representation of each dislocation segment in the crystal and also identifies dislocation junctions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an ADC radiation tolerance characterization system for the upgrade of the ATLAS LAr calorimeter

ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. Here, to evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of photoelastic modulator based dichrometers: maintaining constant phase across the spectrum

Photoelastic modulators can alter the polarization state of a beam of ultraviolet, visible or infrared photons by means of periodic stress-induced differences in the refractive index of a transparent material that forms the optical element of the device and is isotropic in the absence of stress. Furthermore, they have found widespread application in instruments that characterize or alter the polarization state of a beam in fields as diverse as astronomy, structural biology, materials science and ultraviolet lithography for the manufacture of nano-scale integrated circuits. Measurement of circular dichroism, the differential absorption of left- and right circularly polarized light, and of strain-induced birefringence of optical components are major applications. Instruments using synchrotron radiation and photoelastic modulators with CaF 2 optical elements have extended circular dichroism measurements down to wavelengths of about 130 nm in the vacuum ultraviolet. Maintaining a constant phase shift between two orthogonal polarization states across a spectrum requires that the amplitude of the modulated stress be changed as a function of wavelength. For commercially available photoelastic modulators, the voltage that controls the amplitude of modulation required to produce a specified phase shift, which is a surrogate for the stress modulation amplitude, has been shown to be an approximately linear function of wavelength in the spectral region where the optical element is transparent. But, extrapolations of such straight lines cross zero voltage at a non-zero wavelength, not at zero-wavelength. For modulators with calcium fluoride and fused silica optical elements, the zero-crossing wavelength is always in the spectral region where the optical element of the modulator strongly absorbs the incident radiation, and at a wavelength less than the longest-wavelength apparent resonance deduced from experimental values of the refractive index fit to the Sellmeier equation. Using a model that relates the refractive indices of a stressed optical element to the refractive index of its unstressed state, an expression for the modulator control voltage was derived that closely fits the experimental data. Our result provides a theoretical rational for the apparently linear constant-phase programming voltage, and thus provides theoretical backing for the calibration procedure frequently used for these modulators. Lastly there are other factors that can influence the calibration of a photoelastic modulator, including temperature and atmospheric pressure, are discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-element germanium detectors for synchrotron applications

In this paper, we have developed a series of monolithic multi-element germanium detectors, based on sensor arrays produced by the Forschungzentrum Julich, and on Application-specific integrated circuits (ASICs) developed at Brookhaven. Devices have been made with element counts ranging from 64 to 384. These detectors are being used at NSLS-II and APS for a range of diffraction experiments, both monochromatic and energy-dispersive. Compact and powerful readout systems have been developed, based on the new generation of FPGA system-on-chip devices, which provide closely coupled multi-core processors embedded in large gate arrays. Finally, we will discuss the technical details of the systems, and present some of the results from them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of FELIX based readout system for HV-CMOS sensor testbeam

The High Voltage CMOS (HV-CMOS) sensors are extensively investigated by the ATLAS collaboration for the High-Luminosity LHC (HL-LHC) upgrade of the Inner Tracker (ITk) detector. The HV-CMOS technology is a commercial integrated circuit process with the advantages of monolithic readout and fast charge collection. A front-end test platform of CaRIBOu (Control and Readout Itk BOard) and a testbeam Telescope based on the ATLAS IBL (Insertable B-Layer) silicon pixel modules, have been developed for the HV-CMOS sensor study and characterization in testbeam experiments. The Front-End LInk eXchange (FELIX) system is a newapproach to function as the gateway between detector front-end electronics and the commodity switched network in the ATLAS upgrade. A FELIX based readout system has been developed for both the CaRIBOu and the testbeam Telescope. It has been deployed successfully in the testbeam at theCERNSPS H8 beamline in August 2017. The test results show that the readout system is capable of sensor calibration and readout of a high-density pixel detector with high trigger rate in testbeam experiments.

47 OTHER INSTRUMENTATION↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waveform processing using neural network algorithms on the front-end electronics

In a multi-channel radiation detector readout system, waveform sampling, digitization, and raw data transmission to the data acquisition system constitute a conventional processing chain. The deposited energy on the sensor is estimated by extracting peak amplitudes, area under pulse envelopes from the raw data, and starting times of signals or time of arrivals. However, such quantities can be estimated using machine learning algorithms on the front-end Application-Specific Integrated Circuits (ASICs), often termed as “edge computing”. Edge computation offers enormous benefits, especially when the analytical forms are not fully known or the registered waveform suffers from noise and imperfections of practical implementations. In this work, we aim to predict peak amplitude from a single waveform snippet whose rising and falling edges containing only 3 to 4 samples. We thoroughly studied two well-accepted neural network algorithms, Multi-Layer Perceptron (MLP) and Convolutional Neural Network (CNN) by varying their model sizes. Further, to better fit front-end electronics, neural network model reduction techniques, such as network pruning methods and variable-bit quantization approaches, were also studied. By combining pruning and quantization, our best performing model has the size of 1.5 KB, reduced from 16.6 KB of its full model counterpart. It can reach mean absolute error of 0.034 comparing to that of a naive baseline of 0.135. Such parameter-efficient and predictive neural network models established feasibility and practicality of their deployment on front-end ASICs.

47 OTHER INSTRUMENTATION↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗