Search NASA⌕ Search

SEARCH · Search NASA

Results for “Normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Deep-learning-based domain adaptation for cavity fault prediction at Jefferson Laboratory

Superconducting radio-frequency (SRF) cavities are the core components of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, providing high-power electron beams for nuclear physics experiments. The facility comprises 418 SRF cavities, and any fault in these cavities can lead to interruptions in the electron beam supply. Cavity faults are the leading cause of beam trips in CEBAF. Predicting and mitigating those faults before onset can help maintain normal operation. Existing models face challenges in distinguishing between normal and fault signals when changes occur in the underlying time-series data, from changes in control software, operational parameters, or the environment. This work proposes a deep learning domain adaptation model that leverages transfer learning to address fault prediction challenges by improving accuracy. The model is trained and fine-tuned using a dataset collected for faulty and normal operation using a data acquisition system in CEBAF. Our deep learning-based domain adaptation model achieves a prediction accuracy of 89.61% of the fault and normal signals. The developed model effectively predicts normal running signals compared to the baseline approach without domain adaptation. This capacity is essential for the fault prediction task in the CEBAF because of heavily imbalanced data containing vast amounts of normal signals. The model performs well for predicting faults several hundred milliseconds before the fault onset compared to other models where no adaptation is applied. Incorporating deep learning-based domain adaptation techniques will significantly improve the fault prediction performance.

Rahman, Md Monibor [Old Dominion Univ., Norfolk, V↗

An analysis of confidence limit calculations used in AAPM Task Group No. 119

Purpose: The report issued by AAPM Task Group No. 119 outlined a procedure for evaluating the effectiveness of IMRT commissioning. The procedure involves measuring gamma pass-rate indices for IMRT plans of standard phantoms and determining if the results fall within a confidence limit set by assuming normally distributed data. As stated in the TG report, the assumption of normally distributed gamma pass rates is a convenient approximation for commissioning purposes, but may not accurately describe the data. Here the authors attempt to better describe gamma pass-rate data by fitting it to different distributions. The authors then calculate updated confidence limits using those distributions and compare them to those derived using TG No. 119 method. Methods: Gamma pass-rate data from 111 head and neck patients are fitted using the TG No. 119 normal distribution, a truncated normal distribution, and a Weibull distribution. Confidence limits to 95% are calculated for each and compared. A more general analysis of the expected differences between the TG No. 119 method of determining confidence limits and a more time-consuming curve fitting method is performed. Results: The TG No. 119 standard normal distribution does not fit the measured data. However, due to the small range of measured data points, the inaccuracy of the fit has only a small effect on the final value of the confidence limits. The confidence limits for the 111 patient plans are within 0.1% of each other for all distributions. The maximum expected difference in confidence limits, calculated using TG No. 119's approximation and a truncated distribution, is 1.2%. Conclusions: A three-parameter Weibull probability distribution more accurately fits the clinical gamma index pass-rate data than the normal distribution adopted by TG No. 119. However, the sensitivity of the confidence limit on distribution fit is low outside of exceptional circumstances.

60 APPLIED LIFE SCIENCES↗

Evaluation of the potential utility of flat panel CT for quantifying relative contrast enhancement

Purpose: Certain directed oncologic therapies seek to take advantage of the fact that tumors are typically more susceptible to directed therapeutic agents than normal tissue owing to their extensive networks of poorly formed, leaky vasculature. If differences between the vascularity of normal and tumor tissues could be quantified, patients could be selected for or excluded from directed treatments on the basis of this difference. However, angiographic imaging techniques such as digital subtraction angiography (DSA) yield two-dimensional data that may be inadequate for this task. As a first step, the authors evaluated the feasibility of using a commercial implementation of flat panel computed tomography (FPCT) to quantify differences in enhancement of a simulated tumor compared with normal tissue based on differences in CT number measured in precontrast and postcontrast scans. Methods: To evaluate the FPCT scanner studied, the authors scanned several phantoms containing simulated normal and tumor tissues. In the first experiment, the authors used an anthropomorphic phantom containing inclusions representing normal, tumor, and bone tissue to evaluate the constancy of CT numbers in scans repeated at clinically relevant intervals of 1 and 3 min. The authors then scanned gelatin phantoms containing dilutions of iodinated contrast to evaluate the accuracy of relative contrast enhancement measurements for a clinical FPCT system. Data were analyzed using widely available software. Results: CT numbers measured in identical locations were constant over both scan intervals evaluated. Measured relative contrast enhancement values were accurate compared with known relative contrast enhancement values. Care must be taken to avoid artifacts in reconstructed images when placing regions of interest. Conclusions: Despite its limitations, FPCT in the interventional laboratory can be used to quantify relative contrast enhancement in phantoms. This is accomplished by measuring CT number in simulated tumor and normal tissue on precontrast and postcontrast scans. This information opens the door for refinement of technique in an effort to use such a technique to plan directed therapies.

60 APPLIED LIFE SCIENCES↗

Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry

Purpose: To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. Methods: Twenty volumetric images of patient breasts were acquired with a dedicated breast CT prototype system and the voxels in the breast CT images were automatically classified into skin, adipose, and glandular tissue. The breasts in the classified images underwent simulated mechanical compression to mimic the conditions present during mammographic acquisition. The compressed thickness for each breast was set to that achieved during each patient's last screening cranio-caudal (CC) acquisition. The volumetric glandular density of each breast was computed using both the compressed and uncompressed classified images, and additional images were created in which all voxels representing adipose and glandular tissue were replaced by a homogeneous mixture of these two tissues in a proportion corresponding to each breast's volumetric glandular density. All four breast images (compressed and uncompressed; heterogeneous and homogeneous tissue) were input into Monte Carlo simulations to estimate the normalized glandular dose during mammography (compressed breasts) and dedicated breast CT (uncompressed breasts). For the mammography simulations the x-ray spectra used was that used during each patient's last screening CC acquisition. For the breast CT simulations, two x-ray spectra were used, corresponding to the x-ray spectra with the lowest and highest energies currently being used in dedicated breast CT prototype systems under clinical investigation. The resulting normalized glandular dose for the heterogeneous and homogeneous versions of each breast for each modality was compared. Results: For mammography, the normalized glandular dose based on the homogeneous tissue approximation was, on average, 27% higher than that estimated using the true heterogeneous glandular tissue distribution (Wilcoxon Signed Rank Test p= 0.00046). For dedicated breast CT, the overestimation of normalized glandular dose was, on average, 8% (49 kVp spectrum, p= 0.00045) and 4% (80 kVp spectrum, p= 0.000089). Only two cases in mammography and two cases in dedicated breast CT with a tube voltage of 49 kVp resulted in lower dose estimates for the homogeneous tissue approximation compared to the heterogeneous tissue distribution. Conclusions: The normalized glandular dose based on the homogeneous tissue mixture approximation results in a significant overestimation of dose to the imaged breast. This overestimation impacts the use of dose estimates in absolute terms, such as for risk estimates, and may impact some comparative studies, such as when modalities or techniques with different x-ray energies are used. The error introduced by the homogeneous tissue mixture approximation in higher energy x-ray modalities, such as dedicated breast CT, although statistically significant, may not be of clinical concern. Further work is required to better characterize this overestimation and potentially develop new metrics or correction factors to better estimate the true glandular dose to breasts undergoing imaging with ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integral dose investigation of non-coplanar treatment beam geometries in radiotherapy

Purpose: Automated planning and delivery of non-coplanar plans such as 4π radiotherapy involving a large number of fields have been developed to take advantage of the newly available automated couch and gantry on C-arm gantry linacs. However, there is an increasing concern regarding the potential changes in the integral dose that needs to be investigated. Methods: A digital torso phantom and 22 lung and liver stereotactic body radiation therapy (SBRT) patients were included in the study. The digital phantom was constructed as a water equivalent elliptical cylinder with a major axis length of 35.4 cm and minor axis of 23.6 cm. A 4.5 cm diameter target was positioned at varying depths along the major axis. Integral doses from intensity modulated, non-coplanar beams forming a conical pattern were compared against the equally spaced coplanar beam plans. Integral dose dependence on the phantom geometry and the beam number was also quantified. For the patient plans, the non-coplanar and coplanar beams and fluences were optimized using a column generation and pricing approach and compared against clinical VMAT plans using two full (lung) or partial coplanar arcs (liver) entering at the side proximal to the tumor. Both the average dose to the normal tissue volume and the total volumes receiving greater than 2 Gy (V2) and 5 Gy (V5) were evaluated and compared. Results: The ratio of integral dose from the non-coplanar and coplanar plans depended on the tumor depth for the phantom; for tumors shallower than 10 cm, the non-coplanar integral doses were lower than coplanar integral doses for non-coplanar angles less than 60°. Similar patterns were observed in the patient plans. The smallest non-coplanar integral doses were observed for tumor 6–8 cm deep. For the phantom, the integral dose was independent of the number of beams, consistent with the liver SBRT patients but the lung SBRT patients showed slight increase in the integral dose when more beams were used. Larger tumor size and larger patient body size did not change the overall relationship of integral doses between non-coplanar and coplanar cases. However, the thin disk-shaped tumor received at least 40% greater integral doses with the non-coplanar plans. Overall, patient non-coplanar integral doses and V5 were comparable to those of coplanar doses from the same optimization engine and 15%–20% lower than state of the art VMAT plans. However, non-coplanar beams significantly increased V2 in both the phantom and patients. On average, the lung and liver SBRT patient normal tissue volumes receiving dose greater than 2 Gy were increased by 749 and 532 cm{sup 3}, respectively. Conclusions: The authors used a digital phantom simulating a patient torso and 22 SBRT patients to show that the integral doses from the plans employing optimized non-coplanar beams are comparable to those of the coplanar plans using an equal number of discrete beams and are significantly lower than those of VMAT plans. The non-coplanar beams expose a larger normal tissue volume to non-zero doses, whose impact will need to be evaluated individually to determine the risk/benefit ratio of the non-coplanar plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

On multichannel film dosimetry with channel-independent perturbations

Purpose: Different multichannel methods for film dosimetry have been proposed in the literature. Two of them are the weighted mean method and the method put forth byMicke et al. [“Multichannel film dosimetry with nonuniformity correction,” Med. Phys. 38, 2523–2534 (2011)] and Mayer et al. [“Enhanced dosimetry procedures and assessment for EBT2 radiochromic film,” Med. Phys. 39, 2147–2155 (2012)]. The purpose of this work was to compare their results and to develop a generalized channel-independent perturbations framework in which both methods enter as special cases. Methods: Four models of channel-independent perturbations were compared: weighted mean, Micke–Mayer method, uniform distribution, and truncated normal distribution. A closed-form formula to calculate film doses and the associated type B uncertainty for all four models was deduced. To evaluate the models, film dose distributions were compared with planned and measured dose distributions. At the same time, several elements of the dosimetry process were compared: film type EBT2 versus EBT3, different waiting-time windows, reflection mode versus transmission mode scanning, and planned versus measured dose distribution for film calibration and for γ-index analysis. The methods and the models described in this study are publicly accessible through IRISEU. Alpha 1.1 ( http://www.iriseu.com ). IRISEU. is a cloud computing web application for calibration and dosimetry of radiochromic films. Results: The truncated normal distribution model provided the best agreement between film and reference doses, both for calibration and γ-index verification, and proved itself superior to both the weighted mean model, which neglects correlations between the channels, and the Micke–Mayer model, whose accuracy depends on the properties of the sensitometric curves. With respect to the selection of dosimetry protocol, no significant differences were found between transmission and reflection mode scanning, between 75 ± 5 min and 20 ± 1 h waiting-time windows or between employing EBT2 or EBT3 films. Significantly better results were obtained when a measured dose distribution was used instead of a planned one as reference for the calibration, and when a planned dose distribution was used instead of a measured one as evaluation for the γ-analysis. Conclusions: The truncated normal distribution model of channel-independent perturbations was found superior to the other three models under comparison and the authors propose its use for multichannel dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-428: Dosimetric Impact of Multileaf Collimator Leaf Width On Single and multiple Isocenter Stereotactic IMRT Treatment Plans for multiple Brain Tumors

Purpose: To assess the impacts that multileaf collimator (MLC) leaf width has on the dose conformity and normal brain tissue doses of single and multiple isocenter stereotactic IMRT (SRT) plans for multiple intracranial tumors. Methods: Fourteen patients with 2–3 targets were studied retrospectively. Patients treated with multiple isocenter treatment plans using 9 to 12 non-coplanar beams per lesion underwent repeat planning using single isocenter and 10 to 12 non-coplanar beams with 2.5mm, 3mm and 5mm MLC leaf widths. Brainlab iPlan treatment planning system for delivery with the 2.5mm MLC served as reference. Identical contour sets and dose-volume constraints were applied. The prescribed dose to each target was 25 Gy to be delivered over 5 fractions with a minimum of 99% dose to cover ≥ 95% of the target volume. Results: The lesions and normal brains ranged in size from 0.11 to 51.67cc (median, 2.75cc) and 1090 to 1641cc (median, 1401cc), respectively. The Paddick conformity index for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) was (0.79±0.08 vs. 0.79±0.07 and 0.77±0.08) and (0.79±0.09 vs. 0.77±0.09 and 0.76±0.08), respectively. The average normal brain volumes receiving 15 Gy for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) were (3.65% vs. 3.95% and 4.09%) and (2.89% vs. 2.91% and 2.92%), respectively. Conclusion: The average dose conformity observed for the different leaf width for single and multiple isocenter plans were similar, throughout. However, the average normal brain volumes receiving 2.5 to 15 Gy were consistently lower for the 2.5mm MLC leaf width, especially for single isocenter plans. The clinical consequences of these integral normal brain tissue doses are still unknown, but employing the use of the 2.5mm MLC option is desirable at sparing normal brain tissue for both single and multiple isocenter cases.

60 APPLIED LIFE SCIENCES↗

SU-E-T-491: Influence of Applicator Dimensions On Doses to Bladder, Rectum and Sigmoid in HDR Brachytherapy for Cervical Cancer

Purpose: To study the influence of dimensions of the tandem and ring applicator on bladder D2cc, rectum D2cc and sigmoid D2cc in HDR treatment planning for cervical cancer. Methods: 53 plans from 13 patients treated at our institution with the tandem and ring applicator were retrospectively reviewed. Prescription doses were one of the following: 8 Gy x 3, 7 Gy x 4 and 5.5 Gy x 5. Doses to the D2ccs of the bladder, rectum and the sigmoid were recorded. These doses were normalized to their relative prescriptions doses. Correlations between the normalized bladder D2cc, rectum D2cc and sigmoid D2cc were investigated and linear regression models were developed to study the dependence of these doses on the ring diameter and the applicator angle. Results: Normalized doses to the D2cc of the bladder, rectum and sigmoid showed statistically significant correlation (P < 0.05) to the applicator angle. Significant correlation was also noted for the normalized D2cc of the rectum and the sigmoid with the ring diameter. The normalized bladder D2cc was found to decrease with applicator angle on an average by 22.65% ± 4.43% while the same for the rectum and sigmoid were found to increase on an average by 14.43% ± 1.65% and 14.01% ± 1.42% respectively. Both the rectum and sigmoid D2cc reduced with increasing ring diameter by 12.93% ± 1.95% and 11.27% ± 1.79%. No correlation was observed between the normalized bladder D2cc and the ring diameter. Conclusion: Preliminary regression models developed in this study can potentially aid in the choice of the appropriate applicator angle and ring diameter for tandem and ring implant so as to optimize doses to the bladder, rectum and sigmoid.

60 APPLIED LIFE SCIENCES↗

Therapeutic analysis of high-dose-rate {sup 192}Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to (13.4){sup 4} for the radiosensitive normal tissue depending on the cylinder size, treatment lengths, prescription depth, and dose as well. However, for a uniform cancer cell distribution, the EUDs were between 6.3 Gy × 4 and 7.1 Gy × 4, and the TRs were found to be between (1.4){sup 4} and (1.7){sup 4}. For the uniformly interspersed cancer and radio-resistant normal cells, the TRs were less than 1. The two VCBT prescription regimens were found to be equivalent in terms of EUDs and TRs. Conclusions: HDR VCBT strongly favors cylindrical target volume with the cancer cell distribution following its dosimetric trend. Assuming a half-Gaussian distribution of cancer cells, the HDR VCBT provides a considerable radiobiological advantage over the external beam radiotherapy (EBRT) in terms of sparing more normal tissues while maintaining the same level of cancer cell killing. But for the uniform cancer cell distribution and radio-resistant normal tissue, the radiobiology outcome of the HDR VCBT does not show an advantage over the EBRT. This study strongly suggests that radiation therapy design should consider the cancer cell distribution inside the target volume in addition to the shape of target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evolution of Friction and Permeability in a Propped Fracture under Shear

We explore the evolution of friction and permeability of a propped fracture under shear. We examine the effects of normal stress, proppant thickness, proppant size, and fracture wall texture on the frictional and transport response of proppant packs confined between planar fracture surfaces. The proppant-absent and proppant-filled fractures show different frictional strength. For fractures with proppants, the frictional response is mainly controlled by the normal stress and proppant thickness. The depth of shearing-concurrent striations on fracture surfaces suggests that the magnitude of proppant embedment is controlled by the applied normal stress. Under high normal stress, the reduced friction implies that shear slip is more likely to occur on propped fractures in deeper reservoirs. The increase in the number of proppant layers, from monolayer to triple layers, significantly increases the friction of the propped fracture due to the interlocking of the particles and jamming. Permeability of the propped fracture is mainly controlled by the magnitude of the normal stress, the proppant thickness, and the proppant grain size. Permeability of the propped fracture decreases during shearing due to proppant particle crushing and related clogging. Proppants are prone to crushing if the shear loading evolves concurrently with the normal loading.

42 ENGINEERING↗

NbTa_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys niobium-tantalum (Nb-Ta). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach \cite{PAW}. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Nb. For Ta, p semi-core states as valence were chosen. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for ternary alloys is AXBYCZ, where A, B, and C refer to the constituents, and X, Y, and Z are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name case-N where N ranges between 11 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. Subdirectories with name case-N, where N ranges between 1 and 10 (extremes included) contain all the files listed above except 'vaspout.h5'. Subdirectories with name case-N, where N ranges between 41 and 60 (extremes included), contain a duplicate copy of the files listed above except for KPOINTS. The names of the duplicate files end with -bis, and correspond to a second VASP calculation that has converged to a different optimized geometry. This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. and Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. and Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal-amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. and Furthmüller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15-50 (1996) (4) Kresse, G. and Furthmüller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. and Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗

TaV_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys tantalum-vanadium (Tanu-V). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the element V. For Ta, p semi-core states as valence were chosen. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter and OLCF-Summit using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for binary alloys is AXBY, where A and B refer to the constituents, whereas X and Y are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name case-N where N ranges between 11 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. Subdirectories with name case-N, where N ranges between 1 and 10 (extremes included) contain all the files listed above except 'vaspout.h5'. Subdirectories with name case-N, where N ranges between 41 and 60 (extremes included), contain a duplicate copy of the files listed above except for KPOINTS. The names of the duplicate files end with -bis, and correspond to a second VASP calculation that has converged to a different optimized geometry. This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. and Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. and Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal-amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. and Furthmuller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15-50 (1996) (4) Kresse, G. and Furthmuller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. and Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗

NbV_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys niobium-vanadium (Nb-V). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach \cite{PAW}. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Nb and V. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter and OLCF-Summit using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for binary alloys is AXBY, where A and B refer to the constituents, whereas X and Y are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name case-N where N ranges between 11 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. Subdirectories with name case-N, where N ranges between 1 and 10 (extremes included) contain all the files listed above except 'vaspout.h5'. Subdirectories with name case-N, where N ranges between 41 and 60 (extremes included), contain a duplicate copy of the files listed above except for KPOINTS. The names of the duplicate files end with -bis, and correspond to a second VASP calculation that has converged to a different optimized geometry. This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. and Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. and Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal-amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. and Furthmüller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15-50 (1996) (4) Kresse, G. and Furthmüller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. and Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗

Next Generation Nuclear Plant Phenomena Identification and Ranking Tables (PIRTs) Volume 2: Accident and Thermal Fluids Analysis PIRTs

An accident, thermal fluids, and reactor physics phenomena identification and ranking process was conducted by a panel of experts on the next generation nuclear plant (NGNP) design (consideration given to both pebble-bed and prismatic gas-cooled reactor configurations). Safety-relevant phenomena, importance, and knowledge base were assessed for the following event classes: (1) normal operation (including some reactor physics aspects), (2) general loss of forced circulation (G-LOFC), (3) pressurized loss-of-forced circulation (P-LOFC), (4) depressurized loss-of-forced circulation (D-LOFC), (5) air ingress (following D-LOFC), (6) reactivity transients - including anticipated transients without scram (ATWS), (7) processes coupled via intermediate heat exchanger (IHX) (IHX failure with molten salt), and (8) steam/water ingress. The panel's judgment of the importance ranking of a given phenomenon (or process) was based on the effect it had on one or more figures of merit or evaluation criteria. These included public and worker dose, fuel failure, and primary (and other safety) system integrity. The major phenomena of concern that were identified and categorized as high importance combined with medium to low knowledge follow: (1) core coolant bypass flows (normal operation), (2) power/flux profiles (normal operation), (3) outlet plenum flows (normal operation), (4) reactivity-temperature feedback coefficients for high-plutonium-content cores (normal operation and accidents), (5) fission product release related to the transport of silver (normal operation), (6)emissivity aspects for the vessel and reactor cavity cooling system (G-LOFC), (7) reactor vessel cavity air circulation and heat transfer (G-LOFC), and (8)convection/radiation heating of upper vessel area (P-LOFC).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Analysis of Occurrences: January 1, 2011-December 31, 2011

This report documents the analysis of the occurrences during the period January 1, 2011 through December 31, 2011. The report compares LLNL occurrences by reporting criteria and significance category to see if LLNL is reporting occurrences along similar percentages as other DOE sites. The three-year trends are analyzed. It does not include the analysis of the causes or the lessons learned from the occurrences, as they are analyzed separately. The number and types of occurrences that LLNL reports to DOE varies over time. This variation can be attributed to normally occurring changes in frequency; DOE's or LLNL's heightened interest in a particular subject area; changes in LLNL processes; or emerging problems. Since all of the DOE sites use the same reporting criteria, it is helpful to understand if LLNL is consistent with or diverging from reporting at other sites. This section compares the normalized number of occurrences reported by LLNL and other DOE sites. In order to compare LLNL occurrence reports to occurrence reports from other DOE sites, we normalized (or standardized) the data from the sites. DOE sites vary widely in their budgets, populations, and scope of work and these variations may affect reporting frequency. In addition, reports are required for a wide range of occurrence types, some of which may not be applicable to all DOE sites. For example, one occurrence reporting group is Group 3, Nuclear Safety Basis, and not all sites have nuclear operations. Because limited information is available for all sites, the sites were normalized based on best available information. Site effort hours were extracted from the DOE Computerized Accident Incident Reporting System (CAIRS) and used to normalize (or standardize) the number of occurrences by site. Effort hours are those hours that employees normally work and do not include vacation, holiday hours etc. Sites are responsible for calculating their effort hours and ensuring entry into CAIRS. Out of the 30 DOE sites that reported occurrences into ORPS during January 2011 through December 2011, 28 had effort hours available in CAIRS. Two sites had not submitted effort hours data to CAIRS as of the time data was pulled for this report. In those two cases, third quarter data was used as an estimate of fourth quarter data. The use of estimated data may introduce minor errors in the average, median, and Pearson calculations. Using the effort hours and the frequency of occurrences by site, a rate of occurrence frequency per 100 FTE workers was calculated. This rate is similar to the injury/illness frequency rate: the number of injury/illness cases per 100 FTE workers. To validate that this rate was appropriate to use, we compared the effort hours and the frequency of occurrences by site to determine if a relationship exists between the two, e.g. the more effort hours a site has, the more occurrences they tend to have. This hypothesis was tested using the Pearson Correlation Coefficient Test. The correlation coefficient measures the strength of the linear relationship between effort hours and occurrence frequency. The Pearson Correlation Coefficient Test will determine if the true correlation coefficient is equal to zero (no relationship exists), or if the correlation coefficient is not equal to zero (a relationship exists). Values approaching 1.00 show a more positive correlation. Simple linear regression was also used to display a trend line and to test if a one-way relationship exists between effort hours predicting the number of occurrences a site will have. Using the Pearson Correlation test, for the NNSA sites, effort hours and the number of occurrences are significantly and positively correlated with a correlation coefficient of 0.90, as was also seen in the previous report (correlation coefficient of 0.67). All DOE sites are positively correlated with a coefficient of 0.85. As the effort hours increase, so does the number of occurrences and vice versa. Based on the results of the simple linear regression, effort hours were found to predict the number of occurrences.

99 GENERAL AND MISCELLANEOUS↗

Development of Single Cell Raman Spectroscopy for Cancer Screening and Therapy Monitoring

The overall goal of this project was to develop a new technology for cancer detection based on single cell laser tweezers Raman spectroscopy (LTRS). This method has the potential to improve the detection of cancer characteristics in single cells by acquiring cellular spectral markers that reflect the intrinsic biology of the cell. These spectral biomarkers are a new form of molecular signatures in the field of cancer research that may hold promise in accurately identifying and diagnosing cancer and measuring patient response to treatment. The primary objectives of this proposed work were to perform a full characterization of the Raman spectra of single normal, transformed, and cancer cells to identify cancer spectral signatures, validate the clinical significance of these results by direct correlation to established clinical parameters for assessing cancer, and to develop the optical technology needed for efficient sampling and analysis of cells needed for the practical use of such a system in the clinic. The results indicated that normal T and B lymphocytes could be distinguished from their neoplastic cultured cells and leukemia patient cells with classification sensitivities and specificities routinely exceeding 90% based on multivariate statistical analysis and leave-one-out cross validation. Differences primarily in the Raman peaks associated with DNA and protein were observed between normal and leukemic cells and were consistent for both the cultured and primary cells. Differences between normal and leukemia patient cells were more subtle than between normal and leukemia cultured cells but were still significant to allow for accurate discrimination. Furthermore, it is revealed that the spectral differences are representative of the neoplastic phenotype of the cells and not a reflection of the different metabolic states (resting versus active) of normal and leukemic cells. The effect of different standard cell fixation protocols (i.e. methanol, paraformaledhye) on the Raman spectra and ultimately the ability to discriminate between cell types was also studied. Results suggest that paraformaldehyde fixation does not significantly affect the Raman signals, but methanol fixation causes inaccurate Raman classification. Development of a new optofluidic platform for analyzing and sorting cells based on Raman spectroscopy (‘Raman activated cell sorting or RACS’) was achieved, which lays the foundation for developing next generation Raman flow cytometry.

42 ENGINEERING↗

Material Model Testing in the DYNA3D Code: Material Models 1 through 5

This report is the first volume in an effort to study the material model implementations in DYNA3D, using the latest developmental version of the code. Input files were derived from a template supplied by Jerry Lin to perform an equation-of-state study. Most of the simulations use 10 cubes, each 1 cm on a side with a density of 8.03 (steel). Each of the cubes tests a different aspect of the material model. The first three cubes are testing normal stresses and normal strains (uniaxial stresses and strains) placed on the cube parallel to the x-axis, y-axis and z-axis, respectively. The x (or y or z) = 1 face of the cube is moved along the x-axis (or y-axis or z-axis) to test the model, while the opposite side remains in the x (or y or z) = 0 plane. For some of the tests, the nodes are free to move perpendicular to the applied strain to allow the cross-sectional area of the cube to change in response to being placed under pressure or tension (to test Poisson’s Ratio), while in others the nodes are frozen to eliminate dynamic effects resulting from the code. The cube is placed in tension along the axis being tested and then released, followed by a cycle of compression and release. This tension/compression cycle is repeated 3 more times. The additional cycles allow for the model to be tested under different loads. For these calculations, the amount by which the cube is stretched and compressed is varied from cycle to cycle to allow testing of model features. Cubes number 4 and 5 are intended to test xy shear stresses/strains. This is done by sliding one face of the cube in its plane parallel to the axis of interest. For example, for cube 4, the upper face of the cube is slid in the y=1 plane in a direction parallel to the x-axis (so there are no changes in the y and z coordinates of the points in the plane) and then returned to its starting position. This preserves the volume of the cube, so there is no change in density or pressure. The cycle is repeated 8 times. For cube 5, the plane of the cube satisfying x=1 is slid in this plane in a direction parallel to the y-axis and then returned to its starting position. This preserves the volume of the cube, so there is no change in density or pressure. The cycle is repeated 8 times. Cubes number 6 through 9 repeat these tests for yz shear stresses/strains (Cubes 6 and 7) and zx shear stresses and strains (Cubes 8 and 9). For reasons discussed in the next paragraph, it is unclear if these tests represent a state of pure shear stress and shear strain in the code. Application of shear stresses and strains should not, in general, result in the appearance of normal stresses and strains in Cubes 4 - 9. In the infinitesimal limit, this result might be obtained. However, DYNA3D is a finite deformation code and in the real deformations used in the code, this result is not achieved and the individual components of the normal stresses and strains are non-zero during the cycling. However, the sums of the normal strains are zero in these tests and, except in the case of thermally dependent models, so are the sums of the normal stresses. Cube 10 tests the response of the material model to a hydrostatic loading of the cube. The load curve used for the first three tests is used again and applied to each of the 8 nodes in a manner causing the cube to be either compressed or expanded. This compression/tension cycle is repeated 4 times. The additional cycles allow for the model to be tested under different loads. The amount by which the cube is stretched and compressed is varied from cycle to cycle to allow testing of model features. This document will discuss the testing of Material Models 1 through 5. Relevant results from the test cubes will be discussed. A discussion of the results from all 10 test cubes will be presented only if necessary.

36 MATERIALS SCIENCE↗