Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated relatively small variations, with the maximum COV around 11.4%. This might be attributed to the angular mA modulation, the placement of the dosimeters, the chest cavity of the scanned region, and the size of the phantom. Doses to the spinal cord were consistently lower than those to other soft tissues.Conclusions: The method is suited for acquiring densely sampled organ dose maps, and can be used for studying dose distributions relevant to subject size, organ location, and clinical CT protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model and Analytic Processes for Export License Assessments

This paper represents the Department of Energy Office of Nonproliferation Research and Development (NA-22) Simulations, Algorithms and Modeling (SAM) Program's first effort to identify and frame analytical methods and tools to aid export control professionals in effectively predicting proliferation intent; a complex, multi-step and multi-agency process. The report focuses on analytical modeling methodologies that alone, or combined, may improve the proliferation export control license approval process. It is a follow-up to an earlier paper describing information sources and environments related to international nuclear technology transfer. This report describes the decision criteria used to evaluate modeling techniques and tools to determine which approaches will be investigated during the final 2 years of the project. The report also details the motivation for why new modeling techniques and tools are needed. The analytical modeling methodologies will enable analysts to evaluate the information environment for relevance to detecting proliferation intent, with specific focus on assessing risks associated with transferring dual-use technologies. Dual-use technologies can be used in both weapons and commercial enterprises. A decision-framework was developed to evaluate which of the different analytical modeling methodologies would be most appropriate conditional on the uniqueness of the approach, data availability, laboratory capabilities, relevance to NA-22 and Office of Arms Control and Nonproliferation (NA-24) research needs and the impact if successful. Modeling methodologies were divided into whether they could help micro-level assessments (e.g., help improve individual license assessments) or macro-level assessment. Macro-level assessment focuses on suppliers, technology, consumers, economies, and proliferation context. Macro-level assessment technologies scored higher in the area of uniqueness because less work has been done at the macro level. An approach to developing testable hypotheses for the macro-level assessment methodologies is provided. The outcome of this works suggests that we should develop a Bayes Net for micro-level analysis and continue to focus on Bayes Net, System Dynamics and Economic Input/Output models for assessing macro-level problems. Simultaneously, we need to develop metrics for assessing intent in export control, including the risks and consequences associated with all aspects of export control.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Single and pair neutron transfers at sub-barrier energies

Multinucleon transfer cross sections in the {sup 96}Zr+{sup 40}Ca system have been measured, in inverse kinematics, at bombarding energies ranging from the Coulomb barrier to {approx}25% below. Targetlike recoils have been identified in A, Z and velocity with the large solid angle magnetic spectrometer PRISMA. The experimental data for one- and two-neutron transfer channels have been compared with semiclassical microscopic calculations. For the two-neutron transfer channels the relevance of the transitions to the ground state and to the 0{sup +} excited states of {sup 42}Ca are discussed by employing, for the reaction mechanism, the successive approximation. It is found that the transition to the 0{sup +} state at {approx}6 MeV, whose wave function is dominated by the two neutrons in the 2p{sub 3/2} shell, is much larger than the ground state one. The comparison with the inclusive data reveals that transitions to states with high multipolarity and non-natural parity are important. This suggests that more complex two-particle correlations have to be incorporated in the treatment of the transfer process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Component Failure Rate Data Sources for Probabilistic Safety and Reliability

Probabilistic safety methods are being used in several industries, including chemical, manufacturing, and energy. When performing reliability studies or using probabilistic safety approaches, a basic need arises for input data on failure rates of the mechanical, electrical, instrumentation and control, and other components that comprise the engineering systems in the facility. Some companies have many types of data stored and can retrieve these in-house data for such uses. Other companies hire consultants to perform safety assessments; the consulting firms often use their own data bases. For those analysts who do not have either of those options available, this paper presents some data sources that are retrievable from the literature. These data sources have been evaluated with a basic rating of usefulness for analysis work, and each has a description of what data can be found in the citation that can be used to support assessments in industry. The accessibility of data documents via the internet is also described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of the Sum-of-Fractions Methodology for Water and Polyethylene Moderated Systems

Sum-of-Fractions is a method intended to assure a subcritical margin for aqueous solutions and slurries of fissionable isotopes. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope in a mixture to its individual minimum subcritical mass limit is less than or equal to one. The basis of the Sum-of Fractions has historically been derived from allowances given in ANSI/ANS-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the Sum-of-Fractions for water or polyethylene moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 mAm, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water or polyethylene moderated and reflected mixtures containing the nuclides are evaluated with SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water or polyethylene moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the k eff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Crystal accumulation in the Hanford Waste Treatment Plant high level waste melter: Summary of FY2016 experiements

Five experiments were completed with the full-scale, room temperature Hanford Waste Treatment and Immobilization Plant (WTP) high-level waste (HLW) melter riser test system to observe particle flow and settling in support of a crystal tolerant approach to melter operation. A prototypic pour rate was maintained based on the volumetric flow rate. Accumulation of particles was observed at the bottom of the riser and along the bottom of the throat after each experiment. Measurements of the accumulated layer thicknesses showed that the settled particles at the bottom of the riser did not vary in thickness during pouring cycles or idle periods. Some of the settled particles at the bottom of the throat were re-suspended during subsequent pouring cycles, and settled back to approximately the same thickness after each idle period. The cause of the consistency of the accumulated layer thicknesses is not year clear, but was hypothesized to be related to particle flow back to the feed tank. Additional experiments reinforced the observation of particle flow along a considerable portion of the throat during idle periods. Limitations of the system are noted in this report and may be addressed via future modifications. Follow-on experiments will be designed to evaluate the impact of pouring rate on particle re-suspension, the influence of feed tank agitation on particle accumulation, and the effect of changes in air lance positioning on the accumulation and re-suspension of particles at the bottom of the riser. A method for sampling the accumulated particles will be developed to support particle size distribution analyses. Thicker accumulated layers will be intentionally formed via direct addition of particles to select areas of the system to better understand the ability to continue pouring and re-suspend particles. Results from the room temperature system will be correlated with observations and data from the Research Scale Melter (RSM) at Pacific Northwest National Laboratory, and coordinated with modeling efforts underway at Idaho National Laboratory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Total Mercury Analysis of Radioactive Waste Containing Multiple Mercury Species

In this work, a direct mercury analyzer (DMA) was used to analyze total mercury in radioactive waste samples containing methylmercury and other forms of mercury including Hg o (elemental) together with inorganic ionic mercury species and complexes. These samples were also analyzed using Cold Vapor Atomic Absorption Spectroscopy (CVAAS) and/or Inductively Coupled Plasma Mass Spectroscopy (ICMS). Comparative statistical evaluation of the results from spike solutions/simulants, liquid radioactive waste samples, and interlaboratory performance test samples demonstrated that the various methods generated accurate and/or equivalent total mercury data and equivalent precision (2σ ± < 20%). Triplicate total mercury analysis of an exemplar radioactive waste resulted in an average value of 54.1 mg/L (as Hg) using CVAAS, 55.1 mg/L using ICPMS and 56.0 mg/L using DMA. A primary advantage of the DMA in a radioactive environment is avoiding multi-step, labor-intensive, time-consuming and waste-producing sample preparation protocols needed for CVAAS and ICPMS. DMA was determined to be the preferred method for measuring total mercury in the Savannah River National Laboratory (SRNL) radioanalytical laboratory based on analytical performance combined with ease of use in a radiological containment unit.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Energy levels of odd-even nuclei using broken pair model

A method to calculate energy levels and wave functions of odd-even nuclei, in the frame work of the broken pair model have been developed. The accuracy of the model has been tested by comparing the shell model results of limiting cases in which the broken pair model exactly coincides with the shell model, where there are two-proton/neutron + one-neutron/proton in the valence levels. The model is then applied to calculate the energy levels of some nuclei in the Zirconium region. The model results compare reasonably well with the shell model as well as with the experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 230 Th( p ,2n)Pa229 and 230 Th( p ,3n)Pa228 reaction cross sections from 14.1 to 16.9 MeV

Actinium-225 is of interest for medical isotope production and there is on-going research into methods of producing Ac 225 , either directly or via the decay of its parent isotopes ( Th 229 , Pa 229 , and Ra 225 ). One method that has been suggested is the Th 230 ( p , 2 n ) Pa 229 reaction. However, there is no available cross-section data for this reaction in the literature. Purpose: Measure the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reaction cross sections in the energy range where the ( p , 2 n ) reaction is predicted to peak to determine the feasibility of Ac 225 production via the Th 230 ( p , 2 n ) reaction. Methods: Targets naturally enriched in Th 230 were irradiated at the Center for Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory with energies ranging from 14.1 to 16.9 MeV. Furthermore, chemical processing was used to separate the protactinium activation products, followed by γ -ray spectroscopy to measure the activities of Pa 228 , 229 , 230 , 232 produced in the irradiation. Results: We find that excitation functions are reported for the first time in the literature for the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reactions in this energy range. The peak measured value of the Th 230 ( p , 2 n ) reaction was found to be 182 ± 12 mb at 14.4 ± 0.1 MeV. The Th 232 ( p , n ) Pa 232 reaction was used to verify the experimental conditions, the measured values are reported and are comparable to the existing literature values. From the γ -ray spectrometry data, the half-life of Pa 229 was measured as 1.5 ± 0.1 days, which is within the error of the half-life reported in the evaluated nuclear data as well as in the recent measurements, and the half-life of Pa 228 was measured as 19.5 ± 0.4 hours. Conclusions: Overall, the Th 230 ( p , 2 n ) Pa 229 reaction could reasonably be used for Ac 225 isotope production, although significant amounts of relatively isotopically pure Th 230 would be needed for significant production because the low alpha-decay branching ratio of Pa 229 and long half-life of Th 229 inhibit the in-growth of significant amounts of Ac 225 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Generation of Bondarenko F factors with MCNP5 for use in scale transport codes

Generally there are three methods of cross-section processing available when using the Scale computer code. They are NITAWL, BONAMI, and CENTRM, with CENTRM being the most common and accurate, but computationally expensive. In order to improve the accuracy of BONAMI (which uses the Bondarenko Method), new Bondarenko/F Factors were to be generated that will smooth out the current F Factors that are being generated using CENTRM. The case discussed here involves using a dedicated Monte Carlo code (MCNP5) to calculate the transport solution from which shielded cross-sections can be produced directly for the transport geometry/mesh. A simple program was created to parse and collect the tallied cross-sections from the MCNP output, which was fed into a modified CLAROL input (a module that replaces or adds data in an AMPX master library), which used the cross-sections obtained from MCNP to calculate new F-factors and update the SCALE library. This approach allows the use of other methods to generate the shielded cross-sections and for easy comparison to existing results. Initial proof-of-principle calculations were carried out for an various cases using various transport solvers, such as NEWT, KENO, and XSDRN, with BONAMI in SCALE. Poor results were obtained using cross-sections generated using infinite homogeneous cases, but good results were obtained by using pin cells in an infinite lattice. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gas-Phase Stability of Large Lanthanide:Ligand Clusters Evaluated Using Collision-Induced Dissociation

Introduction In the reprocessing of f-elements present in used nuclear fuels, a variety of diglycolamides (DGA’s) are used as extractants for actinide partitioning. In particular, the Actinide-Lanthanide Separation (ALSEP) process typically utilizes either the N,N,N’,N’-tetraoctyl diglycolamide (TODGA) or N,N,N',N'-tetra-2-ethylhexyl diglycolamide (T2EHDGA) extractant ligands following the partitioning of uranium and plutonium from used nuclear fuel. To better understand fundamental interactions in these processes, covalent bonding of several f-elements with diglycolamides, primarily TODGA, is investigated in the gas phase using nanospray ionization and a quadrupole time-of-flight mass spectrometer. Further, analysis of the identity and relative strength of the cluster is enabled by MS2 isolation and collision induced dissociation. Methods Metal ion cluster analysis was completed using a Bruker (Billerica, MA, USA) mircOTOF-Q II quadrupole time-of-flight mass spectrometer with a CaptiveSpray nanospray ion source. Detection was accomplished using positive ionization mode. Metal: ligand solutions were assembled as 30 µM europium nitrate, samarium nitrate, cerium nitrate, or holmium nitrate and 3 µM DGA in acetonitrile or a 50:50 mixture of acetonitrile: isopropanol. Preliminary data The samarium cluster experiments yielded clusters with a samarium:TODGA ratio of up to 1:7 able to be isolated and evidence of greater ratios present in the mass spectrum. This is surprising, as metal clusters are not expected to have a coordination space able to accommodate this many TODGA ligands, due to its size and tridenticity. Collisional activation of [Sm(TODGA)3]3+ suggested loss of a TODGA radical cation, in addition to ligand fragmentation. In contrast, activation of clusters with higher Sm:TODGA ratios resulted in loss of entire ligands, with no evidence of fragmentation. A lower collision energy was required to remove ligands as the number of bound TODGAs increased, suggesting that in larger clusters, ligands are more delicately complexed to the metal. In addition, several clusters were observed with the composition [Sm(NO3)x(TODGA)n x]+3 x. With a single nitrate ion, clusters with up to six TODGAs were able to be isolated. In a similar pattern to the samarium clusters containing only TODGA, less collision energy was required to eliminate one or more TODGAs with increasing size. Clusters with composition [Sm(NO3)(TODGA)n-1]2+ appeared in lower abundance and were more collisionally stable than [Sm(TODGA)n]3+ clusters. With two nitrate ions, only clusters with a single TODGA were able to be isolated. Analogous europium experiments resulted in similar clusters. Ratios of up to 1:7 Eu:TODGA and clusters with one nitrate and up to five TODGAs were isolated. In clusters with two nitrate ions, only one or two TODGAs were observed to be bound. Similar to samarium, MS2 experiments with the Eu clusters suggested that larger clusters required less collision energy to eliminate TODGA. Europium clusters with the composition [Eu(NO3)(TODGA)n-1]2+ were observed in greater abundance and with greater stability than the equivalent cluster with the composition [Eu(TODGA)n]3+. Novel Aspect These are the first reported Ln:TODGA clusters, allowing us to begin to investigate intrinsic complexation of lanthanides with process-relevant ligands.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo Simulations Of The Dose Distributions From Carbon Microbeams Used In An Experimental Radiation Therapy Method

Recent upgrades of the MCNPX Monte Carlo code include transport of heavy ions. We employed the new code to simulate the energy and dose distributions produced by carbon beams in rabbit's head in and around a brain tumor. The work was within our experimental technique of interlaced carbon microbeams, which uses two 90 deg. arrays of parallel, thin planes of carbon beams (microbeams) interlacing to produce a solid beam at the target. A similar version of the method was earlier developed with synchrotron-generated x-ray microbeams. We first simulated the Bragg peak in high density polyethylene and other materials, where we could compare the calculated carbon energy deposition to the measured data produced at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The results showed that new MCNPX code gives a reasonable account of the carbon beam's dose up to {approx}200 MeV/nucleon beam energy. At higher energies, which were not relevant to our project, the model failed to reproduce the Bragg-peak's extent of increasing nuclear breakup tail. In our model calculations we determined the dose distribution along the beam path, including the angular straggling of the microbeams, and used the data for determining the optimal values of beam spacing in the array for producing adequate beam interlacing at the target. We also determined, for the purpose of Bragg-peak spreading at the target, the relative beam intensities of the consecutive exposures with stepwise lower beam energies, and simulated the resulting dose distribution in the spread out Bragg-peak. The details of the simulation methods used and the results obtained are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cross sections of the {sup 67}Zn(n,{alpha}){sup 64}Ni reaction at 4.0, 5.0, and 6.0 MeV

Experimental cross section data of the {sup 67}Zn(n,{alpha}){sup 64}Ni reaction are very scanty because the residual nucleus {sup 64}Ni is stable and the commonly used activation method is not feasible. As a result, very large deviations (about 10 times) exist among different nuclear data libraries. In the present work, cross sections of the partial {sup 67}Zn(n,{alpha}{sub 0}){sup 64}Ni and total {sup 67}Zn(n,{alpha}){sup 64}Ni reactions are measured at neutron energies of 4.0 and 5.0 MeV for the first time, and those of 6.0 MeV are remeasured for consistency checking. A twin-gridded ionization chamber was used as the charged-particle detector and two enriched back-to-back-set {sup 67}Zn samples were adopted. Experiments were performed at the 4.5 MV Van de Graaff Accelerator of Peking University. Neutrons were produced through the {sup 2}H(d,n){sup 3}He reaction using a deuterium gas target. Absolute neutron flux was determined by counting the fission fragments from a {sup 238}U sample placed inside the gridded ionization chamber while a BF{sub 3} long counter was employed as neutron flux monitor. Present data are compared with results of previous measurements, evaluations, and talys code calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Annual Progress Report on Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

The objective of this project is to develop and demonstrate methods for transmission of information in nuclear facilities by acoustic means along existing in-place metal piping infrastructure. Pipes are omnipresent in a nuclear facility, and penetrate enclosures and partitions, such as the containment building wall. In the envisioned acoustic communication (AC) system, packets of information will be transmitted as guided acoustic waves along pipes. Performance of AC hardware and network protocols for efficient and secure communications under development in this project will be eventually evaluated in a representative nuclear power plant environment. Research efforts in the first year of this project have been focused on identification of appropriate transducers, and evaluation of their performance for information transmission along nuclear-grade metallic pipes. COMSOL computer simulations were performed to study acoustic wave generation, propagation, and attenuation on pipes. An experimental benchtop system was used to evaluate signal attenuation and spectral dispersion using piezo-electric transducers (PZTs) and electromagnetic acoustic transducers (EMATs). Communication protocols under evaluation consisted on-off keying (OOK) signal modulation, in particular amplitude shift keying (ASK) and phase shift keying (PSK). Tradeoffs between signal power and communication data rate were considered for ASK and PSK coding schemes.

42 ENGINEERING↗

Neurohumoral indicators of efficacy radiofrequency cardiac denervation

In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are We Appropriately Selecting Therapy For Patients With Cervical Cancer? Longitudinal Patterns-of-Care Analysis for Stage IB-IIB Cervical Cancer

Purpose: We performed a patterns-of-care analysis evaluating the effects of newer technology and recent research findings on treatment decisions over 26 years to determine whether patients with cervical cancer are being appropriately selected for treatment to optimize the therapeutic ratio. Methods and Materials: A retrospective analysis was conducted using the Surveillance, Epidemiology and End Results (SEER) program from 1983 to 2009. We identified 10,933 women with stage IB-IIB cervical carcinoma. Results: Of the 10,933 subjects identified, 40.1% received surgery, 26.8% received radiation (RT), and 33.1% received surgery plus RT. RT use increased after 2000 compared to prior to 2000, with a corresponding decrease in surgery and surgery plus RT. Among patients with risk factors including tumor size >4 cm, positive parametria, and positive lymph nodes, declining use of surgery plus RT was observed. However, 23% of patients with tumors >4 cm, 20% of patients with positive parametria, and 55% of node-positive patients continued to receive surgery plus RT as of 2009. Factors associated with increased use of surgery plus RT included patient age <50 and node-positive status. Conclusions: In this largest patterns-of-care analysis to date for patients with locally advanced cervical cancer, we found a substantial proportion of patients continue to undergo surgery followed by radiation, despite randomized data supporting the use of definitive radiation therapy, with lower morbidity than surgery and radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Doses to Carotid Arteries After Modern Radiation Therapy for Hodgkin Lymphoma: Is Stroke Still a Late Effect of Treatment?

Purpose: Hodgkin lymphoma (HL) survivors are at an increased risk of stroke because of carotid artery irradiation. However, for early-stage HL involved node radiation therapy (INRT) reduces the volume of normal tissue exposed to high doses. Here, we evaluate 3-dimensional conformal radiation therapy (3D-CRT), volumetric-modulated arc therapy (VMAT), and proton therapy (PT) delivered as INRT along with the extensive mantle field (MF) by comparing doses to the carotid arteries and corresponding risk estimates. Methods and Materials: We included a cohort of 46 supradiaphragmatic stage I-II classical HL patients. All patients were initially treated with chemotherapy and INRT delivered as 3D-CRT (30 Gy). For each patient, we simulated MF (36 Gy) and INRT plans using VMAT and PT (30 Gy). Linear dose-response curves for the 20-, 25-, and 30-year risk of stroke were derived from published HL data. Risks of stroke with each technique were calculated for all patients. Statistical analyses were performed with repeated measures analysis of variance. Results: The mean doses to the right and left common carotid artery were significantly lower with modern treatment compared with MF, with substantial patient variability. The estimated excess risk of stroke after 20, 25, and 30 years was 0.6%, 0.86%, and 1.3% for 3D-CRT; 0.67%, 0.96%, and 1.47% for VMAT; 0.61%, 0.96%, and 1.33% for PT; and 1.3%, 1.72%, and 2.61% for MF. Conclusions: INRT reduces the dose delivered to the carotid arteries and corresponding estimated risk of stroke for HL survivors. Even for the subset of patients with lymphoma close to the carotid arteries, the estimated risk is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Positron Emission Tomography–Based Isotoxic Accelerated Radiation Therapy Is Cost-Effective Compared With Conventional Radiation Therapy: A Model-Based Evaluation

Purpose: To evaluate long-term health effects, costs, and cost-effectiveness of positron emission tomography (PET)-based isotoxic accelerated radiation therapy treatment (PET-ART) compared with conventional fixed-dose CT-based radiation therapy treatment (CRT) in non-small cell lung cancer (NSCLC). Methods and Materials: Our analysis uses a validated decision model, based on data of 200 NSCLC patients with inoperable stage I-IIIB. Clinical outcomes, resource use, costs, and utilities were obtained from the Maastro Clinic and the literature. Primary model outcomes were the difference in life-years (LYs), quality-adjusted life-years (QALYs), costs, and the incremental cost-effectiveness and cost/utility ratio (ICER and ICUR) of PET-ART versus CRT. Model outcomes were obtained from averaging the predictions for 50,000 simulated patients. A probabilistic sensitivity analysis and scenario analyses were carried out. Results: The average incremental costs per patient of PET-ART were €569 (95% confidence interval [CI] €−5327-€6936) for 0.42 incremental LYs (95% CI 0.19-0.61) and 0.33 QALYs gained (95% CI 0.13-0.49). The base-case scenario resulted in an ICER of €1360 per LY gained and an ICUR of €1744 per QALY gained. The probabilistic analysis gave a 36% probability that PET-ART improves health outcomes at reduced costs and a 64% probability that PET-ART is more effective at slightly higher costs. Conclusion: On the basis of the available data, individualized PET-ART for NSCLC seems to be cost-effective compared with CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗