Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Laser pulse induced second- and third-harmonic generation of gold nanorods with real-time time-dependent density functional tight binding (RT-TDDFTB) method

In this paper, we investigate second- and third-harmonic generation processes in Au nanorod systems using the real-time time-dependent density functional tight binding method. Our study focuses on the computation of nonlinear signals based on the time dependent dipole response induced by linearly polarized laser pulses interacting with nanoparticles. We systematically explore the influence of various laser parameters, including pump intensity, duration, frequency, and polarization directions, on harmonic generation. We demonstrate all the results using Au nanorod dimer systems arranged in end-to-end configurations, and disrupting the spatial symmetry of regular single nanorod systems is crucial for second-harmonic generation processes. Furthermore, we study the impact of nanorod lengths, which lead to variable plasmon energies, on harmonic generation, and estimates of polarizabilities and hyper-polarizabilities are provided.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Diagnosis and Treatment of Neurological Disorders by Millimeter-Wave Stimulation

Increasingly, millimeter waves are being employed for telecomm, radar, and imaging applications. To date in the U.S, however, very few investigations on the impact of this radiation on biological systems at the cellular level have been undertaken. In the beginning, to examine the impact of millimeter waves on cellular processes, researchers discovered that cell membrane depolarization may be triggered by low levels of integrated power at these high frequencies. Such a situation could be used to advantage in the direct stimulation of neuronal cells for applications in neuroprosthetics and diagnosing or treating neurological disorders. An experimental system was set up to directly monitor cell response on exposure to continuous-wave, fixed-frequency, millimeter-wave radiation at low and modest power levels (0.1 to 100 safe exposure standards) between 50 and 100 GHz. Two immortalized cell lines derived from lung and neuronal tissue were transfected with green fluorescent protein (GFP) that locates on the inside of the cell membrane lipid bi-layer. Oxonol dye was added to the cell medium. When membrane depolarization occurs, the oxonal bound to the outer wall of the lipid bi-layer can penetrate close to the inner wall where the GFP resides. Under fluorescent excitation (488 nm), the normally green GFP (520 nm) optical signal quenches and gives rise to a red output when the oxonol comes close enough to the GFP to excite a fluorescence resonance energy transfer (FRET) with an output at 620 nm. The presence of a strong FRET signature upon exposures of 30 seconds to 2 minutes at 5-10 milliwatts per square centimeter RF power at 50 GHz, followed by a return to the normal 520-nm GFP signal after a few minutes indicating repolarization of the membrane, indicates that low levels of RF energy may be able to trigger non-destructive membrane depolarization without direct cell contact. Such a mechanism could be used to stimulate neuronal cells in the cortex without the need for invasive electrodes as millimeter waves penetrate skin and bone on the order of 15 mm in depth. Although 50 GHz could not readily penetrate from the outer skull to the center of the cortex, implants on the outer skull or even on the scalp could reach the outer layer of the cerebral cortex where substantial benefit could be realized from such non-contact type excitation.

Siegel, Peter H.↗

Readout system of TPC/MPD NICA project

The time-projection chamber (TPC) is the main tracking detector in the MPD/NICA. The information on charge-particle tracks in the TPC is registered by the MWPG with cathode pad readout. The frontend electronics (FEE) are developed with use of modern technologies such as application specific integrated circuits (ASIC), field-programmable gate arrays (FPGA), and data transfer to a concentrator via a fast optical interface. The main parameters of the FEE are as follows: total number of channels, ∼95 000; data stream from the whole TPC, 5 GB/s; low power consumption, less than 100 mW/ch; signal to noise ratio (S/N), 30; equivalent noise charge (ENC), <1000e{sup –} (C{sub in} = 10–20 pF); and zero suppression (pad signal rejection ∼90%). The article presents the status of the readout chamber construction and the data acquisition system. The results of testing FEE prototypes are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗

Field validation of dynamic mechanical torque measurements using fiber-optic strain sensors for geared wind turbines

Abstract Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory’s Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors’ successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.

17 WIND ENERGY↗

Field Validation of Dynamic Mechanical Torque Measurements for Geared Wind Turbines

Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory's Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors' successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.

17 WIND ENERGY↗

Recommended Changes to Specifications for Demand Controlled Ventilation in California's Title 24 Building Energy Efficiency Standards

In demand-controlled ventilation (DCV), rates of outdoor air ventilation are automatically modulated as occupant density varies. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. DCV is most often used in spaces with highly variable and sometime dense occupancy. In almost all cases, carbon dioxide (CO{sub 2}) sensors installed in buildings provide the signal to the ventilation rate control system. People produce and exhale CO{sub 2} as a consequence of their normal metabolic processes; thus, the concentrations of CO{sub 2} inside occupied buildings are higher than the concentrations of CO{sub 2} in the outdoor air. The magnitude of the indoor-outdoor CO{sub 2} concentration difference decreases as the building's ventilation rate per person increases. The difference between the indoor and outdoor CO{sub 2} concentration is also a proxy for the indoor concentrations of other occupant-generated bioeffluents, such as body odors. Reviews of the research literature on DCV indicate a significant potential for energy savings, particularly in buildings or spaces with a high and variable occupancy. Based on modeling, cooling energy savings from applications of DCV are as high as 20%. With support from the California Energy Commission and the U.S. Department of Energy, the Lawrence Berkeley National Laboratory has performed research on the performance of CO{sub 2} sensing technologies and optical people counters for DCV. In addition, modeling was performed to evaluate the potential energy savings and cost effectiveness of using DCV in general office spaces within the range of California climates. The above-described research has implications for the specifications pertaining to DCV in section 121 of the California Title 24 Standard. Consequently, this document suggests possible changes in these specifications based on the research findings. The suggested changes in specifications were developed in consultation with staff from the Iowa Energy Center who evaluated the accuracy of new CO{sub 2} sensors in laboratory-based research. In addition, staff of the California Energy Commission, and their consultants in the area of DCV, provided input for the suggested changes in specifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Miniature Optical Wide-Angle-Lens Startracker (Mini-OWLS)

This paper provides a brief overview of the design considerations and the current status of the Miniature Optical Wide-Angle Lens Startracker Program. Mini-OWLS offers a revolutionary alternative to the conventional startracker. It is a small, lightweight, low cost, high performance startracker that can be used in a variety of applications including calibration and alignment of Inertial Measurement Units (IMU's) Mini-OWLS makes use of a strap down design incorporating Holographic Optical Elements (HOES) in place of conventional optics. HOES can be multiplexed so that the same aperture can be used for multiple separate optical paths looking in several directions simultaneously without startracker rotation. Additionally, separate Schmidt corrector plates are not required to compensate for spherical aberration. The optical assembly, or what would normally be considered as the telescope, is less than 20 cc in volume, weighs less than 55 grams, and contains the equivalent of three individual telescopes. Each one has a 4 deg Field of View (FOV) with a field of regard of 48 square degrees. Mini-OWLS has a bandwidth of approximately 300 nm in or near the visible wavelength. The projected resolution of the startracker is 5 to 10 arcseconds, depending on the centroiding algorithm used. The Mini-OWLS program was initiated last year and represents a miniaturized version of a similar design for aeronautical applications. The contract is managed by Wright Laboratory, Air Force Systems Command, Wright-Patterson AFB, Ohio, with funding from the Strategic Defense Initiative Organization through Eglin AFB. The initial phase of the program is to build and test a development unit. The second phase is to integrate the startracker with the Charles Stark Draper Laboratory Micromechanical Inertial Guidance System (MIGS) and the Signal Processing Packaging Design (SPPD) being developed by Texas Instruments. The preliminary design review was conducted in November 1991. Three-axes prototype telescope assemblies have been built and design evaluation tests initiated.

Miller, Rick↗

Full-wave and half-wave rectification in second-order motion perception

Microbalanced stimuli are dynamic displays which do not stimulate motion mechanisms that apply standard (Fourier-energy or autocorrelational) motion analysis directly to the visual signal. In order to extract motion information from microbalanced stimuli, Chubb and Sperling [(1988) Journal of the Optical Society of America, 5, 1986-2006] proposed that the human visual system performs a rectifying transformation on the visual signal prior to standard motion analysis. The current research employs two novel types of microbalanced stimuli: half-wave stimuli preserve motion information following half-wave rectification (with a threshold) but lose motion information following full-wave rectification; full-wave stimuli preserve motion information following full-wave rectification but lose motion information following half-wave rectification. Additionally, Fourier stimuli, ordinary square-wave gratings, were used to stimulate standard motion mechanisms. Psychometric functions (direction discrimination vs stimulus contrast) were obtained for each type of stimulus when presented alone, and when masked by each of the other stimuli (presented as moving masks and also as nonmoving, counterphase-flickering masks). RESULTS: given sufficient contrast, all three types of stimulus convey motion. However, only one-third of the population can perceive the motion of the half-wave stimulus. Observers are able to process the motion information contained in the Fourier stimulus slightly more efficiently than the information in the full-wave stimulus but are much less efficient in processing half-wave motion information. Moving masks are more effective than counterphase masks at hampering direction discrimination, indicating that some of the masking effect is interference between motion mechanisms, and some occurs at earlier stages. When either full-wave and Fourier or half-wave and Fourier gratings are presented simultaneously, there is a wide range of relative contrasts within which the motion directions of both gratings are easily determinable. Conversely, when half-wave and full-wave gratings are combined, the direction of only one of these gratings can be determined with high accuracy. CONCLUSIONS: the results indicate that three motion computations are carried out, any two in parallel: one standard ("first order") and two non-Fourier ("second-order") computations that employ full-wave and half-wave rectification.

Motion Perception/physiology↗

Temporal coherence and indistinguishability in two-photon interference effects

We show that temporal two-photon interference effects involving the signal and idler photons created by parametric down-conversion can be fully characterized in terms of the variations of two length parameters--called the biphoton path-length difference and the biphoton path-asymmetry-length difference--which we construct using the six different length parameters that a general two-photon interference experiment involves. We perform an experiment in which the effects of the variations of these two parameters can be independently controlled and studied. In our experimental setup, which does not involve mixing of signal and idler photons at a beam splitter, we further report observations of Hong-Ou-Mandel- (HOM-)like effects both in coincidence and in one-photon count rates. As an important consequence, we argue that the HOM and the HOM-like effects are best described as observations of how two-photon coherence changes as a function of the biphoton path-asymmetry-length difference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray properties of the X-CLASS-redMaPPer galaxy cluster sample: the luminosity–temperature relation

ABSTRACT This article presents the results of a spectroscopic analysis of the X-CLASS-redMaPPer (XC1-RM) galaxy cluster sample. X-CLASS is a serendipitous search for clusters in X-ray wavebands based on the XMM–Newton archive, whereas redMaPPer is an optical cluster catalogue derived from the Sloan Digital Sky Survey (SDSS). The present sample comprises 92 X-ray extended sources identified in optical images within 1 arcmin separation. The area covered by the cluster sample is ∼ 27 deg2. The clusters span a wide redshift range (0.05 < z < 0.6) and 88 clusters benefit from spectrosopically confirmed redshifts using data from SDSS Data Release 14. We present an automated pipeline to derive the X-ray properties of the clusters in three distinct apertures: R500 (at fixed mass overdensity), Rfit (at fixed signal-to-noise ratio) and ${R}_{300\, {\rm kpc}}$ (fixed physical radius). The sample extends over wide temperature and luminosity ranges: from 1–10 keV and from 6 × 1042 to 11 × 1044 erg s−1, respectively. We investigate the luminosity–temperature (L–T) relation of the XC1-RM sample and find a slope equal to 3.03 ± 0.26. It is steeper than predicted by self-similar assumptions, in agreement with independent studies. A simplified approach is developed to estimate the amount and impact of selection biases that might be affecting our recoveredL–Tparameters. The result of this simulation process suggests that the measuredL–Trelation is biased to a steeper slope and higher normalization.

Molham, Mona↗

Type Ia supernova observations combining data from the Euclid mission and the Vera C. Rubin Observatory

ABSTRACT The Euclid mission will provide first-of-its-kind coverage in the near-infrared over deep (three fields, ∼10–20 square degrees each) and wide (∼10 000 square degrees) fields. While the survey is not designed to discover transients, the deep fields will have repeated observations over a two-week span, followed by a gap of roughly six months. In this analysis, we explore how useful the deep field observations will be for measuring properties of Type Ia supernovae (SNe Ia). Using simulations that include Euclid’s planned depth, area, and cadence in the deep fields, we calculate that more than 3700 SNe between 0.0 < $z$ < 1.5 will have at least five Euclid detections around peak with signal-to-noise ratio larger than 3. While on their own, Euclid light curves are not good enough to directly constrain distances, when combined with legacy survey of space and time (LSST) deep field observations, we find that uncertainties on SN distances are reduced by 20–30 per cent for $z$ < 0.8 and by 40–50 per cent for $z$ > 0.8. Furthermore, we predict how well additional Euclid mock data can be used to constrain a key systematic in SN Ia studies – the size of the luminosity ‘step’ found between SNe hosted in high-mass (>1010 M⊙) and low-mass (<1010 M⊙) galaxies. This measurement has unique information in the rest-frame near-infrared (NIR). We predict that if the step is caused by dust, we will be able to measure its reduction in the NIR compared to optical at the 4σ level. We highlight that the LSST and Euclid observing strategies used in this work are still provisional and some level of joint processing is required. Still, these first results are promising, and assuming that Euclid begins observations well before the Nancy Roman Space Telescope (Roman), we expect this data set to be extremely helpful for preparation for Roman itself.

Astronomy & Astrophysics↗

Lidar

Lidar is an optical radar technique employing laser energy. Variations in signal intensity as a function of range provide information on atmospheric constituents, even when these are too tenuous to be normally visible. The theoretical and technical basis of the technique is described and typical values of the atmospheric optical parameters given. The significance of these parameters to atmospheric and meteorological problems is discussed. While the basic technique can provide valuable information about clouds and other material in the atmosphere, it is not possible to determine particle size and number concentrations precisely. There are also inherent difficulties in evaluating lidar observations. Nevertheless, lidar can provide much useful information as is shown by illustrations. These include lidar observations of: cirrus cloud, showing mountain wave motions; stratification in clear air due to the thermal profile near the ground; determinations of low cloud and visibility along an air-field approach path; and finally the motion and internal structure of clouds of tracer materials (insecticide spray and explosion-caused dust) which demonstrate the use of lidar for studying transport and diffusion processes.

Collis, R. T. H.↗

A LIS Validation Study at the KSC-ER using LDAR and Field Mill Data

The chance of having the TRMM satellite pass over east central Florida when there is lightning over the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER) is small; however, such a condition did occur on September 21, 1998 (Day 264). Starting at about 20:40 GMT, the Lightning Imaging Sensor (LIS) reported 5 flashes during a 90 second interval that the KSC-ER was within the sensor field of view. Ground-based instrumentation, the Lightning Detection and Ranging (LDAR) system and a network of electric field mills (FM), detected 6 flashes in the same interval. In this paper, we will compare the times and locations of the optical pulses that were detected by LIS with the times and locations of RF sources (LDAR) and the charges that were deposited by the flash (FM network). We will show that LIS responded to all flashes that the LDAR and FM network detected; however, two discharges that were separated by less than 1 second in time and by about 10 km in space were grouped as one flash by the LIS data processing algorithm. In spite of the fact that all flashes occurred near the edge of the LIS field of view, the locations of the LIS events were consistent with both the LDAR and FM locations (the latter are usually within 1-2 kilometers of each other and often are co-located). Two of the 5 flashes reported by LIS were shifted north by about 8 km from the corresponding LDAR and FM locations. The LIS flash times tended to be after the first LDAR pulse was detected and before the last, and the integrated light signal (per LIS event) was surprisingly constant over the 5 flashes that were detected by LIS. In the future, we plan to study more correlated events and will try to determine whether and how the LIS light signal is related to the charge transfer in the flash and/or the number and spatial extent of RF sources.

Koshak, William J.↗

Monitoring internal organ motion with continuous wave radar in CT

Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

A versatile pressure-cell design for studying ultrafast molecular-dynamics in supercritical fluids using coherent multi-pulse x-ray scattering

Supercritical fluids (SCFs) can be found in a variety of environmental and industrial processes. They exhibit an anomalous thermodynamic behavior, which originates from their fluctuating heterogeneous micro-structure. Characterizing the dynamics of these fluids at high temperature and high pressure with nanometer spatial and picosecond temporal resolution has been very challenging. The advent of hard x-ray free electron lasers has enabled the development of novel multi-pulse ultrafast x-ray scattering techniques, such as x-ray photon correlation spectroscopy (XPCS) and x-ray pump x-ray probe (XPXP). These techniques offer new opportunities for resolving the ultrafast microscopic behavior in SCFs at unprecedented spatiotemporal resolution, unraveling the dynamics of their micro-structure. However, harnessing these capabilities requires a bespoke high-pressure and high-temperature sample system that is optimized to maximize signal intensity and address instrument-specific challenges, such as drift in beamline components, x-ray scattering background, and multi-x-ray-beam overlap. We present a pressure cell compatible with a wide range of SCFs with built-in optical access for XPCS and XPXP and discuss critical aspects of the pressure cell design, with a particular focus on the design optimization for XPCS.

47 OTHER INSTRUMENTATION↗

Coupling to rotational manifolds to improve gas-phase pump–probe spectroscopic models

The physical picture of gas-phase optical transitions is normally presented as an isolated two-level system balanced by upward and downward processes. Isolated models assume a phenomenological treatment of collisional dephasing but do not strictly account for collisional population exchange with the rotational baths. While this assumption is valid under low-intensity conditions, where excitation is rate-limiting, isolated models can deviate from Beer’s Law at sufficient pressures and monochromatic intensities when both collisional broadening and power broadening are comparable to (or greater than) lifetime broadening, which are not uncommon conditions for cavity enhanced spectroscopies in the mid-IR spectral range. Although this problem has been addressed by rate-equation models for linear absorption measurements, a general treatment for multi-level quantum mechanical models suitable for non-linear absorption measurements (two-photon/two-color/pump–probe) is lacking. Isolated models require physical parameter inputs that disagree with expected values by at least an order of magnitude. These non-physical models undermine the ability to predict non-linear signal strengths under untested conditions and thereby limit the potential to optimize the sensitivity of non-linear spectroscopies and to expand their analytical applications (e.g., new analytes and/or buffer gases, changes in cavity free-spectral-range, changes in intracavity powers or wavelengths, and accurate investigation of physical phenomena). In this study, we derive bath-coupled models for gaseous pump–probe spectroscopy by application of the quantum Lindblad equation and detailed balance. Bath-coupled models are shown to fit data consistently across variations in intensity and agree with all physically expected values.

Cavity ring-down spectroscopy↗