Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimal sizing method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

SU-G-TeP1-10: Predicting Photon Percentage Depth Dose From Profile Due to Changes in Beam Quality

Purpose: To predict photon percentage depth dose (PDD) from profile due to a change in flattened (FF) and flattening-filter-free (FFF) beam quality. Methods: 6MV photon beam PDDs and profiles in a 3D water tank (3DW) and profiles in an ionization chamber array (ICP) were collected for different field sizes and depths with FF and FFF beams in a Versa HD (Elekta Ltd.). The energy was adjusted by changing the bending magnet current (BMC) ±15% from the clinical beam (6MV) in 5% increments. For baseline establishment, PDDs(depth≥3cm) were parameterized with bi-exponential functions and the PDD 20 to 10cm ratios (PDD{sub 20,10}) were calculated. Then, the FF profile at 10cm from the central axis (Pr{sub 10}) and the slope of the FFF central linear region (SFFF) were calculated. Calibration curves were established: (1) change in Pr{sub 10} and SFFF as functions of the change in PDD{sub 20,10} and (2) change in PDD(depth=3, 15 and 30cm) as function of the change in PDD{sub 20,10}. The differences between Pr{sub 10} and SFFF from baseline were calculated and, from calibration curves, changes in PDD{sub 20,10} and PDD(depth=3, 15 and 30cm) were obtained. Then, absolute PDD(depth=3, 15 and 30cm) values were input into a least-square-optimization algorithm to calculate the bi-exponential function’s optimal coefficients and generate the PDD(depths≥3cm). Results: The change in PDD{sub 20,10} relative to baseline increased (<±4%) with BMC. Pr{sub 10} increased (±6%) and SFFF decreased (±11%) with BMC. Relative differences between measured and calculated (i.e. PDD calculation from Pr{sub 10} and SFFF) PDDs were less than 1%. Results apply to FF and FFF beams measured in 3DW and ICP. Conclusion: Pr{sub 10} and SFFF are more sensitive than PDD to changes in beam energy and PDD information can be accurately generated from them. With known 3DW and ICP profile relationship, ICP can be used to obtain PDD for current photon beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-209-01: Making Benchtop X-Ray Fluorescence Computed Tomography (XFCT) Practical for in Vivo Imaging by Integration of a Dedicated High-Performance X-Ray Source in Conjunction with Micro-CT Functionality

Purpose: To make benchtop x-ray fluorescence computed tomography (XFCT) practical for routine preclinical imaging tasks with gold nanoparticles (GNPs) by deploying, integrating, and characterizing a dedicated high-performance x-ray source and addition of simultaneous micro-CT functionality. Methods: Considerable research effort is currently under way to develop a polychromatic benchtop cone-beam XFCT system capable of imaging GNPs by stimulation and detection of gold K-shell x-ray fluorescence (XRF) photons. Recently, an ad hoc high-power x-ray source was incorporated and used to image the biodistribution of GNPs within a mouse, postmortem. In the current work, a dedicated x-ray source system featuring a liquid-cooled tungsten-target x-ray tube (max 160 kVp, ∼3 kW power) was deployed. The source was operated at 125 kVp, 24 mA. The tube’s compact dimensions allowed greater flexibility for optimizing both the irradiation and detection geometries. Incident x-rays were shaped by a conical collimator and filtered by 2 mm of tin. A compact “OEM” cadmium-telluride x-ray detector was implemented for detecting XRF/scatter spectra. Additionally, a flat panel detector was installed to allow simultaneous transmission CT imaging. The performance of the system was characterized by determining the detection limit (10-second acquisition time) for inserts filled with water/GNPs at various concentrations (0 and 0.010–1.0 wt%) and embedded in a small-animal-sized phantom. The phantom was loaded with 0.5, 0.3, and 0.1 wt% inserts and imaged using XFCT and simultaneous micro-CT. Results: An unprecedented detection limit of 0.030 wt% was experimentally demonstrated, with a 33% reduction in acquisition time. The reconstructed XFCT image accurately localized the imaging inserts. Micro-CT imaging did not provide enough contrast to distinguish imaging inserts from the phantom under the current conditions. Conclusion: The system is immediately capable of in vivo preclinical XFCT imaging with GNPs. Micro-CT imaging will require optimization of irradiation parameters to improve contrast. Supported by NIH/NCI grant R01CA155446; This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

An Assessment of Nuclear Fuel Options for Microreactors

A design options trade-off study was conducted for various nuclear fuel system options. This study developed requirements for ideal fuel system characteristics and weighted ranking criteria specifically for microreactor designs. A semiquantitative method of consensus ranking on a numeric scale was used with input from several nuclear fuel experts. The purpose of this study was to assess options and provide recommendations for further nuclear fuel technology development to better support small reactor cores. Modern microreactor designs have only recently begun emerging and have little in common except their diminutive size. The purpose of this study was not to determine which reactor type is best (e.g., coolant type and/or neutron energy spectrum), but rather to assess fuel system options within five broad categories of reactor types inspired by: 1) Very High Temperature Reactors (VHTR), 2) Sodium Fast Reactors (SFR), 3) System for Nuclear Auxiliary Power (SNAP) reactors, 4) Gas Fast Reactor (GFR), and 5) Molten Salt Reactors (MSR). The order in which these reactor types were listed generally represents the amount of current interest and technological maturity in the microreactor development community (in descending order). As such, the conclusions drawn for each reactor type category have varying levels of certainty, but there is confidence in the general conclusion that known fuel technologies can support small reactors, but that microreactors will be able to maximize their performance potential if these fuel systems were further optimized. These optimization opportunities were found to revolve around increasing uranium loading and improving behaviors/understanding for long time-at-temperature conditions. Further details about these recommendations can be found in the concluding section of this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using the Diffusion Equation to Predict CST Resin Breakthroughs - 19051

The crystalline silicotitanate, CST, resin manufactured by UOP Honeywell is well-suited for single-use decontamination of caustic liquid wastes at Hanford and Savannah River Sites. There are many measurements of column loading and breakthrough for CST resin decontamination of Cs-137 in various Hanford and SRS waste simulants. Such measurements provide a very good basis for estimating CST resin demand and these more refined predictions make the CST column loading as efficient as possible given the very expensive CST resin. Although there are a variety of tools for predicting chromatographic resin column performance, [1-4], there is a particularly useful method that is suitable as a simple spreadsheet model [4]. This spreadsheet model is an analytical error function for the mass transfer zone (mtz) diffusion width in resin columns and is well-suited for resin breakthrough and column loading. This paper describes just such an error function spreadsheet model and how well the error function agrees with more traditional models and fits the observed small scale breakthrough curves for CST that can then better predict large scale column loading efficiency. The very high sorption of Cs onto CST tends to be slower than that of other lower sorption resins and as a result of the slow CST kinetics, there is also a marked asymmetry in many CST breakthrough curves. The CST breakthrough asymmetry is largely due to the distribution of CST particle sizes because smaller particles sorb much faster than larger particles. It is then the smaller particles that determine the leading mtz at a decontamination factor of 1,000 breakthrough and therefore the decontamination efficiency for a given loading. The larger CST particles correspondingly determine the tailing mtz width and therefore the overall loading efficiency and it is important to model both leading and tailing mtz widths to best optimize CST for a particular Cs-137 decontamination application. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs

Purpose: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.Methods: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.Results: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient location. When tumor SNR is held constant (i.e., x-ray fluence is scaled appropriately), SBDX gives 2–10 times less dose than fluoroscopy for the same conditions within the typical range of patient locations. The relative position of the patient (as a percent of SDD) has a much more significant impact on dose than either SDD or patient position. The patient position providing the minimum dose for a given tumor SNR and SDD is approximately the same as the position of maximum tomographic angle.Conclusions: SBDX offers a significant dose advantage over currently used C-arm fluoroscopy. The patient location with lowest dose coincides with the location of maximum tomographic angle. In order to provide adequate space for the patient and for the pulmonologists’ equipment, a SDD of 100 cm is recommended.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data from 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.

60 APPLIED LIFE SCIENCES↗

SU-F-T-70: A High Dose Rate Total Skin Electron Irradiation Technique with A Specific Inter-Film Variation Correction Method for Very Large Electron Beam Fields

Purpose: Rotational total skin electron irradiation (RTSEI) is used in the treatment of cutaneous T-cell lymphoma. Due to inter-film uniformity variations the dosimetry measurement of a large electron beam of a very low energy is challenging. This work provides a method to improve the accuracy of flatness and symmetry for a very large treatment field of low electron energy used in dual beam RTSEI. Methods: RTSEI is delivered by dual angles field a gantry of ±20 degrees of 270 to cover the upper and the lower halves of the patient body with acceptable beam uniformity. The field size is in the order of 230cm in vertical height and 120 cm in horizontal width and beam energy is a degraded 6 MeV (6 mm of PMMA spoiler). We utilized parallel plate chambers, Gafchromic films and OSLDs as a measuring devices for absolute dose, B-Factor, stationary and rotational percent depth dose and beam uniformity. To reduce inter-film dosimetric variation we introduced a new specific correction method to analyze beam uniformity. This correction method uses some image processing techniques combining film value before and after radiation dose to compensate the inter-variation dose response differences among films. Results: Stationary and rotational depth of dose demonstrated that the Rp is 2 cm for rotational and the maximum dose is shifted toward the surface (3mm). The dosimetry for the phantom showed that dose uniformity reduced to 3.01% for the vertical flatness and 2.35% for horizontal flatness after correction thus achieving better flatness and uniformity. The absolute dose readings of calibrated films after our correction matched with the readings from OSLD. Conclusion: The proposed correction method for Gafchromic films will be a useful tool to correct inter-film dosimetric variation for the future clinical film dosimetry verification in very large fields, allowing the optimizations of other parameters.

60 APPLIED LIFE SCIENCES↗

Prognostic Factors and Patterns of Locoregional Failure After Surgical Resection in Patients With Cholangiocarcinoma Without Adjuvant Radiation Therapy: Optimal Field Design for Adjuvant Radiation Therapy

Purpose: To identify prognostic factors and patterns of local failure in patients with cholangiocarcinoma (CCA), after surgical resection in the absence of adjuvant radiation, for optimal definition of target volumes encompassing the majority of local recurrences. Methods and Materials: A chart review was performed in patients who underwent resection for primary CCA (intrahepatic, hilar, and distal) between 1999 and 2014. Local failure was defined as recurrence in a theoretical reasonable postoperative radiation volume. This includes the cut surface of liver, biliary anastomosis, hilum, portal nodes, celiac nodes, peri-pancreatic nodes, gastro-hepatic nodes, and retroperitoneal nodes. Patients who received adjuvant radiation were excluded. Results: A total of 189 patients underwent surgical resection for CCA, of whom 145 patients had sufficient follow-up. Median follow-up was 41.6 months (95% confidence interval 35.4-48.7 months). Of the 145 cases, 102 were intrahepatic and 43 were hilar/distal CCA. Adjuvant chemotherapy was given in 38 cases (26%), of which 20 (54%) were gemcitabine-based. Eighty-six patients (59%) had a documented recurrence, of whom 44 (51%) had a locoregional component. Among patients who had a recurrence, 23 (27%) had a recurrence at the biliary anastomosis and/or cut liver surface. Twenty-eight patients (32.6%) had a recurrence in the regional lymph nodes, most prevalent in the portal (16.3%) and retroperitoneal (17.4%) lymph nodes. Univariable analysis identified tumor size, any vascular invasion, presence of satellites, stage/nodal status, and receipt of chemotherapy as significant prognostic factors of overall recurrence among intrahepatic patients. Presence of satellites, and stage 3/Nx status remained statistically significant in multivariable modeling. Conclusions: The areas at highest risk for locoregional recurrence after surgical resection for primary CCA are the biliary anastomosis/cut liver surface, portal lymph nodes, and retroperitoneal lymph nodes. Although these results need to be validated, adjuvant radiation should possibly cover these areas to maximize locoregional control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-31: Alternative VMAT Technique Reduces Total Monitor Units for Lung SBRT

Purpose: To investigate an alternative approach to VMAT optimization for hypofractionation lung treatment which increases average aperture opening and results in lower total Monitor Units (MU) without significantly sacrificing plan quality. Methods: Benchmark Volumetric Modulated Arc Therapy (bVMAT) plans were generated for 10 lung Stereotactic Body radiotherapy (SBRT) cases using Eclipse Version 11.0.42 (Varian Medical Systems) without a maximum MU constraint. Prescriptions ranged from 40 to 54Gy in 3 to 5 fractions. AAA dose calculation and PRO fluence based optimization was utilized. Two comparison VMAT plans were generated for each case, one that forced an initial “open” mlc aperture conformal to the tumor as a starting condition (oVMAT) with similar optimization parameters and arc geometries, and one that repeated the bVMAT optimization but added a maximum MU constraint (muVMAT). All plans used two arcs with lengths between 168 to 230 degrees. PTV D 95% and Dmean, lung V20 Gy, chest wall V30 Gy, average aperture opening and MU's were compared. Statistical significance was evaluated using Wilcoxon signed rank test. Results: Average PTV D(95), PTV mean and lung V20Gy over all plans was 99.2 ± 1.7%, 103.3 ± 0.6% and 7.8 ± 2.4% respectively. The average chest wall V30Gy was 61 ± 61 cc and ranged between 0 to 166 cc. There were no significant differences between the three techniques for the dosimetric quantities. MUs were reduced by 11 ±11% (p<0.01) and 25 ± 5% (p<0.01) and the average aperture size was increased by 13.7 ± 14% (p=0.02) and 35.8 ± 10% (p<0.01) with muVMAT and oVMAT, respectively, compared to bVMAT. Conclusion: oVMAT and muVMAT techniques were both able to increase average aperture size and reduce total MU compared to the benchmark VMAT plan, but the magnitude of the changes observed for oVMAT was larger.

60 APPLIED LIFE SCIENCES↗

Electrostatic interaction of macroparticles in a plasma in the strong screening regime

We have studied the electrostatic interaction of spherical particles in an equilibrium plasma or an electrolyte in the moderate and strong screening regimes when the macroparticle size is comparable with or much larger than the Debye screening radius. We have developed an approximate theory of the electrostatic interaction of macroparticles in the case of constant potentials of their surfaces in the weak or moderate screening regimes. In this theory, the charges of macroparticles with a fixed spacing between them are determined using vacuum capacitive coefficients, which are corrected taking into account the plasma screening effects. The force of interaction with the resultant charges is calculated based on the solution of the problem of interaction in a homogeneous dielectric (vacuum) and is multiplied by the plasma factor. We have also obtained an approximate solution to the problem in the strong screening regime. Comparison with the exact solution has demonstrated high accuracy of the proposed methods of calculation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kriging-Based Inverse Uncertainty Quantification of BISON Fission Gas Release Model

Nuclear reactor fuel performance analysis studies the thermo-mechanical behavior of fuel rods and verify their compliance with safety criteria under both normal operation and accidental conditions. One of the major concerns in fuel performance analysis is the behavior of the fission gases xenon and krypton in uranium dioxide fuel, which significantly affect the thermo-mechanical performance of the nuclear fuel rods employed in current LWRs. Previously, the modeling of fission gas release (FGR) in nuclear fuel performance codes have been relying on empirical models which are not applicable beyond their range of calibration. Recently a more efficient and flexible physics-based FGR and swelling model that can describe a wider range of reactor operation conditions have been implemented in fuel performance code BISON. In this work, we performed Bayesian calibration to inversely quantify the uncertainties associated with the 5 tuning parameters in BISON FGR model, based on the time-dependent FGR measurement data from Riso-AN3 benchmark. It takes around 1 hour and 40 minutes for BISON to simulate the Riso-AN3 benchmark with a moderate mesh size using 32 processors. As hundreds of thousands of BISON simulations are needed during Markov Chain Monte Carlo (MCMC) sampling, running BISON directly is not a viable solution. Therefore we propose to use Kriging-based metamodels to replace BISON during MCMC sampling. Surrogate model is an approximation of the input/output relation of a computer code/model. It is also called metamodel, response surface, emulator. Surrogate models usually take much less computational time than the original model (like BISON) while maintaining the input/output relation of the original model to a desirable accuracy. Constructing the metamodels normally requires small number of executions of the original model. Once validated, metamodels can be used to perform uncertainty and sensitivity analysis, Bayesian calibration, optimization, etc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data associated with “Different methods of estimating riverbed sediment grain size diverge at the basin scale ” (v2)

This data package is associated with the publication “Different methods of estimating riverbed sediment grain size diverge at the basin scale” published in Frontiers in Earth Science (Regier et al., 2025). The distribution of sediment grain size in streams and rivers is often quantified by the median grain size (d50), a key metric for understanding and predicting hydrologic and biogeochemical function of streams and rivers. Manual methods to measure d50 are time-consuming and ignore larger grains, while model-based methods to estimate d50 often over-generalize basin characteristics, and therefore cannot accurately represent site-scale heterogeneity. Here, we apply a machine learning-enabled photogrammetry methodology (You Only Look Once, or YOLO) for estimating d50 for grains > 2 mm based on images collected from streams and rivers throughout the Yakima River Basin (YRB). To understand how such methods may help bridge the gaps in resolution and accuracy between manual and catchment characteristics model-based d50 estimates, we compared YOLO d50 values to manual and model-based estimates across the YRB. We found distinct differences among methods for d50 averages and variability, and relationships between d50 estimates and basin characteristics. Source images can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1892052. This data package was originally published in May 2023. It was updated August 2025 (v2; new and modified files). File and folder names were not revised to indicate changes. See the change history section in the readme for more details. In addition to the readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) and subfolders containing data, figures, and scripts. The data folder contains datasets used for the analyses in the manuscript in image, text-delimited or geospatially-referenced formats. The figures folder contains the figures from the manuscript in different formats. The scripts folder contains all of the scripts used to complete the analyses in the manuscript. All files are .csv, .rds, .dbf, .prj, .shp, .shx, .jpg, .png, .R, .Rproj, or .pdf. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Interrelationship between sex, age, blood volume and VO 2 max

Background Circulating blood volume (BV) and maximal oxygen uptake (VO 2 max) are physiological characteristics important for optimal human performance in aerospace and military operational environments. Addressing the interrelationships between BV, VO 2 max, sex, and age together is relevant to identifying those individuals with greatest risk of poor outcomes from hemorrhage, as well as assessing the levels of performance competence of individuals deployed in operational environments. In the present investigation, we report and compare for the first time BV and VO 2 max in a cohort of males and females together to test the hypothesis that BV and VO 2 max is lower in older people independent of sex. Methods To accomplish this, a ‘data mining’ effort of an historic database generated from NASA and U.S. Air Force experiments was conducted. BV, red cell volume, plasma volume, hematocrit, and VO 2 max were measured in 94 healthy individuals (28 females, 66 males) across an age range of 23 to 65 years to assess the interrelationship between sex, age, BV, and VO 2 max. Subjects were classified in age groups by < 40 years and ≥ 40 years; these groups identified females as pre‐ vs. post‐menopausal. Results Consistent with our hypothesis, comparisons revealed that males had higher (p < 0.01) BV, red cell volume, hematocrit, and VO 2 max than females when standardized for body size. Against expectations, BV was not different in older compared with younger males and females. VO 2 max was not different in older compared with younger females, while VO 2 max was lower in older males (p < 0.01). Conclusion We conclude that physiological mechanisms other than BV associated with aging appear to be responsible for a decline in VO 2 max of our older male subjects. Furthermore, factors other than menopause may also influence the control of BV in the female population. Our results provide evidence that aging may not compromise males or females in scenarios where BV can affect performance in aerospace and military environments. Support or Funding Information This research was supported in part by appointment of Ms. Koons to the Postgraduate Research Fellowship Program at the US Army Institute of Surgical Research administered by the Oak Ridge Institute for Science and Education through an interagency agreement between the US Department of Energy and USAMRMC. Study funding was provided by a grant from the US Army Combat Casualty Care Research Program (D‐009‐2014‐USAISR). This abstract is from the Experimental Biology 2019 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Convertino, Victor↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗

Roles of Carburization and Oxidation on Transition-Metal Catalyzed Surface Reactions

Many industrial chemical transformation processes are based on reactions catalyzed by transition metals. In some cases the nano-size particles used as catalysts are synthesized simultaneously or right before the initiation of the main catalytic reaction. Synthesis treatments involve complex processes such as reductions followed by calcinations in oxygenated environments coupled to the presence of gases used for the main reaction. Synthesis details are crucial because they have important consequences on the catalyst shape, size, and chemical composition, and may also affect the structure and composition of the catalyst support. All these effects may alter the main catalyzed reaction in unexpected ways. This work focuses on the synthesis of the overall catalytic system that includes catalyst and support taking place in parallel with the initial stages of the main catalyzed reaction. Two important processes are characterized: carburization and oxidation of the transition metal catalyst during synthesis or initial stages of the main reaction. The objective is to understand how the coking mechanism coupled to surface oxidation and changes in the substrate influence the dry reforming of methane taken as a model reaction. The approach uses first principles computational methods to investigate the catalyst synthesis and characterization and catalytic reaction mechanisms. These studies are complemented with experimental characterization done by the group of Dr. Renu Sharma at the National Institute of Standards and Technology (unfunded collaborator) using high resolution transmission electron microscopy. Specific goals are to identify the role of the synthesis process on the initial nanocatalyst structure and composition, and to determine how that structure and composition may evolve after being exposed to the reactants atmosphere. These studies facilitate a systematic analysis of conditions where the nanoparticle composition can be optimized regarding activity and stability. Moreover, the fundamental study of catalyst/support interactions yields valuable insights for other catalytic processes and is a first step toward controlled nanocatalyst synthesis.

36 MATERIALS SCIENCE↗

Manufacturing Dissolvable Alloy Components using ShAPE: A Study on Solid Phase Processing of Mg-W Composites and WJ11 Alloys

Dissolvable alloys and composites are an emerging class of materials that demonstrate tailored sorptivity in corrosive environments. This work explored the viability of solid phase processing (SPP) techniques, namely the shear assisted processing and extrusion (ShAPETM) method, to manufacture dissolvable magnesium composites and alloys components such as rods and tubes. The study also determined the effects of material composition and manufacturing process conditions on material microstructures developed during SPP and the resulting performance of the components. Explicit properties of interest included ultimate tensile strength, ultimate compressive strength, and yield strength. The application fields of interest for dissolvable alloys were identified as oil-and-gas operations and biomedical implants. Accordingly, PNNL collaborated with industrial and academia partners, Fortek Industries, Houston and University of Pittsburgh, during the course of this project for material and ShAPE process development. PNNL determined the viability of the using ShAPE to process the custom-designed materials provided by the project partners. This was done by identifying process parameters such as tool rotation rate, tool plunge rate, and process cooling optimal for manufacturing components with consolidated microstructures. Subsequently, PNNL also performed microstructural characterization on unprocessed and processed samples and mechanical property testing. One of the major findings from this work is that ShAPE was able to manufacture dissolvable magnesium composite and alloy rods and tubes with consolidated homogeneous microstructures and minimal macroscale defects on component surfaces. It was observed that samples processed via ShAPE demonstrated an average grain size < 2 - 5 µm, which was markedly lower than that of the precursors with 8 – 13 µm grains. Results showed that the ShAPE synthesized dissolvable magnesium composite and alloy strength was on par with or better than those components that were manufactured using traditional manufacturing processes such as forging and extrusion. It is noteworthy that the ShAPE samples were made with considerably lower number of process steps.

36 MATERIALS SCIENCE↗

Large Scale Study of Ligand–Protein Relative Binding Free Energy Calculations: Actionable Predictions from Statistically Robust Protocols

The accurate and reliable prediction of protein–ligand binding affinities can play a central role in the drug discovery process as well as in personalized medicine. Of considerable importance during lead optimization are the alchemical free energy methods that furnish an estimation of relative binding free energies (RBFE) of similar molecules. Recent advances in these methods have increased their speed, accuracy, and precision. This is evident from the increasing number of retrospective as well as prospective studies employing them. However, such methods still have limited applicability in real-world scenarios due to a number of important yet unresolved issues. Here, we report the findings from a large data set comprising over 500 ligand transformations spanning over 300 ligands binding to a diverse set of 14 different protein targets which furnish statistically robust results on the accuracy, precision, and reproducibility of RBFE calculations. We use ensemble-based methods which are the only way to provide reliable uncertainty quantification given that the underlying molecular dynamics is chaotic. These are implemented using TIES (Thermodynamic Integration with Enhanced Sampling). Results achieve chemical accuracy in all cases. Ensemble simulations also furnish information on the statistical distributions of the free energy calculations which exhibit non-normal behavior. We find that the “enhanced sampling” method known as replica exchange with solute tempering degrades RBFE predictions. We also report definitively on numerous associated alchemical factors including the choice of ligand charge method, flexibility in ligand structure, and the size of the alchemical region including the number of atoms involved in transforming one ligand into another. Our findings provide a key set of recommendations that should be adopted for the reliable application of RBFE methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-124: 18F-FDG PET Imaging to Improve RT Treatment Outcome for Locally Advanced Lung Cancer

Purpose: To investigate spatial correlation between high uptake regions of pre- and 10-days-post therapy{sup 1} {sup 8}F-FDG PET in recurrent lung cancer and to evaluate the feasibility of dose escalation boosting only regions with high FDG uptake identified on baseline PET. Methods: Nineteen patients with stages II– IV inoperable lung cancer were selected. Volumes of interest (VOI) on pre-therapy FDG-PET were defined using an isocontour at ≥50% of SUVmax. VOI of pre- and post-therapy PET images were correlated for the extent of overlap. A highly optimized IMRT plan to 60 Gy prescribed to PTV defined on the planning CT was designed using clinical dose constraints for the organs at risk. A boost of 18 Gy was prescribed to the VOI defined on baseline PET. A composite plan of the total 78 Gy was compared with the base 60 Gy plan. Increases in dose to the lungs, spinal cord and heart were evaluated. IMRT boost plan was compared with proton RT and SBRT boost plans. Results: Overlap fraction of baseline PET VOI with the VOI on 10 days-post therapy PET was 0.8 (95% CI: 0.7 – 0.9). Using baseline VOI as a boosting volume, dose could be escalated to 78 Gy for 15 patients without compromising the dose constraints. For 4 patients, the dose limiting factors were V20Gy and Dmean for the total lung, and Dmax for the spinal cord. An increase of the dose to OARs correlated significantly with the relative size of the boost volume. Conclusion: VOI defined on baseline 18F-FDG PET by the SUVmax-≥50% isocontour may be a biological target volume for escalated radiation dose. Dose escalation to this volume may provide improved tumor control without breaching predefined dose constraints for OARs. The best treatment outcome may be achieved with proton RT for large targets and with SBRT for small targets.

60 APPLIED LIFE SCIENCES↗