Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Measurement of regional compliance using 4DCT images for assessment of radiation treatment

Purpose: Radiation-induced damage, such as inflammation and fibrosis, can compromise ventilation capability of local functional units (alveoli) of the lung. Ventilation function as measured with ventilation images, however, is often complicated by the underlying mechanical variations. The purpose of this study is to present a 4DCT-based method to measure the regional ventilation capability, namely, regional compliance, for the evaluation of radiation-induced lung damage. Methods: Six 4DCT images were investigated in this study: One previously used in the generation of a POPI model and the other five acquired at Henry Ford Health System. A tetrahedral geometrical model was created and scaled to encompass each of the 4DCT image domains. Image registrations were performed on each of the 4DCT images using a multiresolution Demons algorithm. The images at the end of exhalation were selected as a reference. Images at other exhalation phases were registered to the reference phase. For the POPI-modeled patient, each of these registration instances was validated using 40 landmarks. The displacement vector fields (DVFs) were used first to calculate the volumetric variation of each tetrahedron, which represents the change in the air volume. The calculated results were interpolated to generate 3D ventilation images. With the computed DVF, a finite element method (FEM) framework was developed to compute the stress images of the lung tissue. The regional compliance was then defined as the ratio of the ventilation and stress values and was calculated for each phase. Based on iterative FEM simulations, the potential range of the mechanical parameters for the lung was determined by comparing the model-computed average stress to the clinical reference value of airway pressure. The effect of the parameter variations on the computed stress distributions was estimated using Pearson correlation coefficients. Results: For the POPI-modeled patient, five exhalation phases from the start to the end of exhalation were denoted by P{sub i}, i=1,...,5, respectively. The average lung volume variation relative to the reference phase (P{sub 5}) was reduced from 18% at P{sub 1} to 4.8% at P{sub 4}. The average stress at phase P{sub i} was 1.42, 1.34, 0.74, and 0.28 kPa, and the average regional compliance was 0.19, 0.20, 0.20, and 0.24 for i=1,...,4, respectively. For the other five patients, their average R{sub v} value at the end-inhalation phase was 21.1%, 19.6%, 22.4%, 22.5%, and 18.8%, respectively, and the regional compliance averaged over all six patients is 0.2. For elasticity parameters chosen from the potential parameter range, the resultant stress distributions were found to be similar to each other with Pearson correlation coefficients greater than 0.81. Conclusions: A 4DCT-based mechanical model has been developed to calculate the ventilation and stress images of the lung. The resultant regional compliance represents the lung's elasticity property and is potentially useful in correlating regions of lung damage with radiation dose following a course of radiation therapy.

60 APPLIED LIFE SCIENCES↗

LWIR Snapshot Imaging Polarimeter

This report describes the results of a phase 1 STTR to design a longwave infrared imaging polarimeter. The system design, expected performance and components needed to construct the imaging polarimeter are described. Expected performance is modeled and sytem specifications are presented.

47 OTHER INSTRUMENTATION↗

A new iron lead vanadate Pb{sub 2}FeV{sub 3}O{sub 11}: Synthesis and some properties

A new iron lead vanadate, Pb{sub 2}FeV{sub 3}O{sub 11}, has been obtained. It melts incongruently at 650 {+-} 5 deg. C depositing two solid phases: Pb{sub 2}V{sub 2}O{sub 7} and Fe{sub 2}O{sub 3}. Pb{sub 2}FeV{sub 3}O{sub 11} crystallises in the monoclinic system. The infra-red spectrum and images of the new phase obtained by means of an electron scanning microscope are presented.

36 MATERIALS SCIENCE↗

SU-E-QI-17: Dependence of 3D/4D PET Quantitative Image Features On Noise

Purpose: Quantitative imaging is a fast evolving discipline where a large number of features are extracted from images; i.e., radiomics. Some features have been shown to have diagnostic, prognostic and predictive value. However, they are sensitive to acquisition and processing factors; e.g., noise. In this study noise was added to positron emission tomography (PET) images to determine how features were affected by noise. Methods: Three levels of Gaussian noise were added to 8 lung cancer patients PET images acquired in 3D mode (static) and using respiratory tracking (4D); for the latter images from one of 10 phases were used. A total of 62 features: 14 shape, 19 intensity (1stO), 18 GLCM textures (2ndO; from grey level co-occurrence matrices) and 11 RLM textures (2ndO; from run-length matrices) features were extracted from segmented tumors. Dimensions of GLCM were 256×256, calculated using 3D images with a step size of 1 voxel in 13 directions. Grey levels were binned into 256 levels for RLM and features were calculated in all 13 directions. Results: Feature variation generally increased with noise. Shape features were the most stable while RLM were the most unstable. Intensity and GLCM features performed well; the latter being more robust. The most stable 1stO features were compactness, maximum and minimum length, standard deviation, root-mean-squared, I30, V10-V90, and entropy. The most stable 2ndO features were entropy, sum-average, sum-entropy, difference-average, difference-variance, difference-entropy, information-correlation-2, short-run-emphasis, long-run-emphasis, and run-percentage. In general, features computed from images from one of the phases of 4D scans were more stable than from 3D scans. Conclusion: This study shows the need to characterize image features carefully before they are used in research and medical applications. It also shows that the performance of features, and thereby feature selection, may be assessed in part by noise analysis.

60 APPLIED LIFE SCIENCES↗

Denoising Poisson phaseless measurements via orthogonal dictionary learning

Phaseless diffraction measurements recorded by CCD detectors are often affected by Poisson noise. In this paper, we propose a dictionary learning model by employing patches based sparsity in order to denoise such Poisson phaseless measurements. The model consists of three terms: (i) A representation term by an orthogonal dictionary, (ii) an L 0 pseudo norm of the coefficient matrix, and (iii) a Kullback-Leibler divergence term to fit phaseless Poisson data. Fast alternating minimization method (AMM) and proximal alternating linearized minimization (PALM) are adopted to solve the proposed model, and especially the theoretical guarantee of the convergence of PALM is provided. The subproblems for these two algorithms both have fast solvers, and indeed, the solutions for the sparse coding and dictionary updating both have closed forms due to the orthogonality of learned dictionaries. Numerical experiments for phase retrieval using coded diffraction and ptychographic patterns are conducted to show the efficiency and robustness of proposed methods, which, by preserving texture features, produce visually and quantitatively improved restored images compared with other phase retrieval algorithms without regularization and local sparsity promoting algorithms.

97 MATHEMATICS AND COMPUTING↗

EUVE Guest Observer Program Handbook: Extreme Ultraviolet Explorer Guest Observer Documentation: Use with Addendum 1 for 1995 - Appendix G

The Extreme Ultraviolet Explorer (EUVE) is a NASA explorer-class satellite mission devoted entirely to observations in the wavelength range from 70 to 760 Angstroms. The science payload incorporates five separate instruments: four photometric imaging systems and a three-channel EUV spectrometer. During the first phase of the mission, the imaging instruments were used to conduct a complete sky survey in four different bands in the EUV. The survey results are available to the scientific community in the first EUVE sky survey bright source list and the first EUVE all-sky catalog. The second part of the mission is being conducted by NASA as a Guest Observer program, for which pointed spectroscopic observations are conducted for guest scientists under proposals submitted to NASA and supported by the EUVE Guest Observer Center at Berkeley. The mission lifetime will extend through at least a third year of observations. Further extensions of the EUVE mission will be partially contingent upon a review process conducted in September of 1994. To support an extended mission, please contact the chair of the EUVE User 's Committee1 or the EUVE Project Office (address below). The EUVE Guest Observer (EGO) Program is supported by the EUVE Guest Observer Center (EGO Center) at the Center for Extreme Ultraviolet Astrophysics (CEA), at the University of California, Berkeley. The policies of the EGO Program and specified in the NRA. This Handbook is produced by the EGO Center as a guide to choosing appropriate targets for observation and preparing proposals. The rest of this chapter gives a broad overview of the EUVE mission and the EGO Center.

EUVE↗

Phase 1 Trial of Bevacizumab With Concurrent Chemoradiation Therapy for Squamous Cell Carcinoma of the Head and Neck With Exploratory Functional Imaging of Tumor Hypoxia, Proliferation, and Perfusion

Purpose: A phase 1 trial was completed to examine the safety and feasibility of combining bevacizumab with radiation and cisplatin in patients with locoregionally advanced squamous cell carcinoma of the head and neck (HNSCC) treated with curative intent. Additionally, we assessed the capacity of bevacizumab to induce an early tumor response as measured by a series of biological imaging studies. Methods and Materials: All patients received a single induction dose of bevacizumab (15 mg/kg) delivered 3 weeks (±3 days) before the initiation of chemoradiation therapy. After the initial dose of bevacizumab, comprehensive head and neck chemoradiation therapy was delivered with curative intent to 70 Gy in 33 fractions with concurrent weekly cisplatin at 30 mg/m{sup 2} and bevacizumab every 3 weeks (weeks 1, 4, 7) with dose escalation from 5 to 10 to 15 mg/kg. All patients underwent experimental imaging with [{sup 18}F]fluorothymidine positron emission tomography (FLT-PET) (proliferation), [{sup 61}Cu]Cu-diacetyl-bis(N4-methylthiosemicarbazone) PET (Cu-ATSM-PET) (hypoxia), and dynamic contrast-enhanced computed tomography (DCE-CT) (perfusion) at 3 time points: before bevacizumab monotherapy, after bevacizumab monotherapy, and during the combined therapy course. Results: Ten patients were enrolled. All had stage IV HNSCC, all achieved a complete response to treatment, and 9 of 10 remain alive, with a mean survival time of 61.3 months. All patients experienced grade 3 toxicity, but no dose-limiting toxicities or significant bleeding episodes were observed. Significant reductions were noted in tumor proliferation (FLT-PET), tumor hypoxia (Cu-ATSM-PET), and DCE-CT contrast enhancement after bevacizumab monotherapy, with further decreases in FLT-PET and Cu-ATSM-PET during the combined therapy course. Conclusions: The incorporation of bevacizumab into comprehensive chemoradiation therapy regimens for patients with HNSCC appears safe and feasible. Experimental imaging demonstrates measureable changes in tumor proliferation, hypoxia, and perfusion after bevacizumab monotherapy and during chemoradiation therapy. These findings suggest opportunities to preview the clinical outcomes for individual patients and thereby design personalized therapy approaches in future trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron imaging of hydrogenous gases in porous-carbon materials around phase transitions

Focus herein is on hydrogenous gases interacting with porous-carbon materials on activated biochar at pressures ranging from 0 to 100 bar and temperatures from room (ambient) to cryogenic. Neutron radiography was conducted using a custom-made cell system to simultaneously image pure gas and gas interacting with the porous carbon. From neutron attenuation, the cross sections of methane and ethane and number concentrations were determined for different pressures and temperatures and compared with corresponding reference data. Sorption properties of the porous materials were investigated in situ with methane, ethane, and propane.

Ossler, Frederik [Lund University, Sweden]↗

Investigation of hepatic fibrosis in rats with x-ray diffraction enhanced imaging

X-ray diffraction enhanced imaging (DEI) is a phase contrast technique that generates excellent contrast of biological soft tissues compared to conventional absorption radiography. We explore the application of DEI in the diagnosis of hepatic fibrosis. The produced refraction contrast images of fibrous rat liver samples show clearly abnormal liver architectures. Moreover, by comparing to histological pictures, different stages of fibrosis are discriminated, and the corresponding morphological features are analyzed. Besides, quantitative analyses of texture features are presented. The results reported herein show that DEI can be a potential noninvasive technique to diagnose and stage hepatic fibrosis.

60 APPLIED LIFE SCIENCES↗

Flow Measurements in a Blood-Perfused Collagen Vessel Using X-Ray Micro-Particle Image Velocimetry

Blood-perfused tissue models are joining the emerging field of tumor engineering because they provide new avenues for modulation of the tumor microenvironment and preclinical evaluation of the therapeutic potential of new treatments. The characterization of fluid flow parameters in such in-vitro perfused tissue models is a critical step towards better understanding and manipulating the tumor microenvironment. However, traditional optical flow measurement methods are inapplicable because of the opacity of blood and the thickness of the tissue sample. In order to overcome the limitations of optical method we demonstrate the feasibility of using phase-contrast x-ray imaging to perform microscale particle image velocimetry (PIV) measurements of flow in blood perfused hydrated tissue-representative microvessels. However, phase contrast x-ray images significantly depart from the traditional PIV image paradigm, as they have high intensity background, very low signal-to-noise ratio, and volume integration effects. Hence, in order to achieve accurate measurements special attention must be paid to the image processing and PIV cross-correlation methodologies. Therefore we develop and demonstrate a methodology that incorporates image preprocessing as well as advanced PIV crosscorrelation methods to result in measured velocities within experimental uncertainty.

59 BASIC BIOLOGICAL SCIENCES↗

Heat release and flame structure measurements of self-excited acoustically-driven premixed methane flames

An open-open organ pipe burner (Rijke tube) with a bluff-body ring was used to create a self-excited, acoustically-driven, premixed methane-air conical flame, with equivalence ratios ranging from 0.85 to 1.05. The feed tube velocities corresponded to Re = 1780-4450. Coupled oscillations in pressure, velocity, and heat release from the flame are naturally encouraged at resonant frequencies in the Rijke tube combustor. This coupling creates sustainable self-excited oscillations in flame front area and shape. The period of the oscillations occur at the resonant frequency of the combustion chamber when the flame is placed {proportional_to}1/4 of the distance from the bottom of the tube. In this investigation, the shape of these acoustically-driven flames is measured by employing both OH planar laser-induced fluorescence (PLIF) and chemiluminescence imaging and the images are correlated to simultaneously measured pressure in the combustor. Past research on acoustically perturbed flames has focused on qualitative flame area and heat release relationships under imposed velocity perturbations at imposed frequencies. This study reports quantitative empirical fits with respect to pressure or phase angle in a self-generated pressure oscillation. The OH-PLIF images were single temporal shots and the chemiluminescence images were phase averaged on chip, such that 15 exposures were used to create one image. Thus, both measurements were time resolved during the flame oscillation. Phase-resolved area and heat release variations throughout the pressure oscillation were computed. A relation between flame area and the phase angle before the pressure maximum was derived for all flames in order to quantitatively show that the Rayleigh criterion was satisfied in the combustor. Qualitative trends in oscillating flame area were found with respect to feed tube flow rates. A logarithmic relation was found between the RMS pressure and both the normalized average area and heat release rate for all flames. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Actuated Hybrid Mirror Telescope

The figure depicts the planned Actuated Hybrid Mirror Telescope (AHMT), which is intended to demonstrate a new approach to the design and construction of wide-aperture spaceborne telescopes for astronomy and Earth science. This technology is also appropriate for Earth-based telescopes. The new approach can be broadly summarized as using advanced lightweight mirrors that can be manufactured rapidly at relatively low cost. More specifically, it is planned to use precise replicated metallic nanolaminate mirrors to obtain the required high-quality optical finishes. Lightweight, dimensionally stable silicon carbide (SiC) structures will support the nanolaminate mirrors in the required surface figures. To enable diffraction- limited telescope performance, errors in surface figures will be corrected by use of mirror-shape-control actuators that will be energized, as needed, by a wave-front-sensing and control system. The concepts of nanolaminate materials and mirrors made from nanolaminate materials were discussed in several previous NASA Tech Briefs articles. Nanolaminates constitute a relatively new class of materials that can approach theoretical limits of stiffness and strength. Nanolaminate mirrors are synthesized by magnetron sputter deposition of metallic alloys and/or compounds on optically precise master surfaces to obtain optical-quality reflector surfaces backed by thin shell structures. As an integral part of the deposition process, a layer of gold that will constitute the reflective surface layer is deposited first, eliminating the need for a subsequent and separate reflective-coating process. The crystallographic textures of the nanolaminate will be controlled to optimize the performance of the mirror. The entire deposition process for making a nanolaminate mirror takes less than 100 hours, regardless of the mirror diameter. Each nanolaminate mirror will be bonded to its lightweight SiC supporting structure. The lightweight nanolaminate mirrors and SiC supporting structures will be fabricated from reusable master molds. The mirror-shape-control actuators will be low-power, high-capacitance lead magnesium niobate electrostrictive actuators that will be embedded in the SiC structures. The mode of operation of these actuators will be such that once power was applied, they will change in length and once power was removed, they will maintain dimensional stability to nanometer precision. This mode of operation will enable the use of low-power, minimally complex electronic control circuitry. The wave-front-sensing and control system will be designed and built according to a two-stage architecture. The first stage will be implemented by a Shack- Hartmann (SH) sensor subsystem, which will provide a large capture range. The second, higher-performance stage will be implemented by an image-based wave-front-sensing subsystem that will include a phase-retrieval camera (PRC), and will utilize phase retrieval and other techniques to measure wavefront error directly. Phase retrieval is a process in which multiple images of an unresolved object are iterated to estimate the phase of the optical system that acquired the images. The combination of SH and phase-retrieval sensors will afford the virtues of both a dynamic range of 105 and an accuracy of <10 nm.

Hickey, Gregory↗

IMAGING FAINT BROWN DWARF COMPANIONS CLOSE TO BRIGHT STARS WITH A SMALL, WELL-CORRECTED TELESCOPE APERTURE

We have used our 1.6 m diameter off-axis well-corrected subaperture (WCS) on the Palomar Hale telescope in concert with a small inner-working-angle phase-mask coronagraph to image the immediate environs of a small number of nearby stars. Test cases included three stars (HD 130948, HD 49197, and HR7672) with known brown dwarf companions at small separations, all of which were detected. We also present the initial detection of a new object close to the nearby young G0V star HD171488. Follow-up observations are needed to determine if this object is a bona fide companion, but its flux is consistent with the flux of a young brown dwarf or low-mass M star at the same distance as the primary. Interestingly, at small angles our WCS coronagraph demonstrates a limiting detectable contrast comparable to that of extant Lyot coronagraphs on much larger telescopes corrected with current-generation adaptive optics (AO) systems. This suggests that small apertures corrected to extreme AO (ExAO) levels can be used to carry out initial surveys for close brown dwarf and stellar companions, leaving follow-up observations for larger telescopes.

99 GENERAL AND MISCELLANEOUS↗

Structural investigation of the temperature-stable relaxor dielectric Ba 0.8 Ca 0.2 TiO 3 -Bi(Mg 0.5 Ti 0.5 )O 3

Aberration corrected scanning transmission electron microscopy (STEM) and electron diffraction have been used to disclose local structure and nano-chemistry in a Ca modified BaTiO 3 -Bi(Mg 0.5 Ti 0.5 )O 3 relax or dielectric ceramic which exhibits high and near-invariant relative permittivity over a wide temperature range. High resolution, synchrotron X-ray diffraction indicated a globally cubic structure ($Pm$$\overline{3}$$m$), but direct atomic-scale imaging by STEM revealed local tetragonal distortions. Nanopolar clusters were identified from B-site atomic displacement vectors measured relative to oxygen ion positions along < 100 > and < 110 > zone axes of integrated differential phase contrast (iDPC) STEM images, highlighting cluster sizes of 2–5 nm. Chemical analysis by STEM-energy dispersive X-ray spectroscopy and full pattern refinements of X-ray powder diffraction data each implied high levels of Bi vacancies within the matrix. The possibility that these A-site vacancies modulate the nanopolar structure and promote flattening of the permittivity-temperature response in this class of dielectric is discussed.

36 MATERIALS SCIENCE↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

Fast imaging of transients and coherent magnetohydrodynamic modes in DIII-D

A fast framing camera is used to image plasma waves and instabilities in the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] in unprecedented detail including tearing modes (TMs) and sawtooth crashes. To image core magnetohydrodynamic (MHD) activity, the fast camera detects visible bremsstrahlung emission {epsilon}{sub B} in moderate to high density plasmas. For coherent MHD activity such as TMs, high-resolution two-dimensional images of mode amplitude and phase are obtained by Fourier filtering each pixel's time series at the mode frequency. Images of m/n=2/1 TMs show that inside the q=2 surface, the camera measurements are in excellent agreement with an analytic model of a 2/1 island superimposed on the equilibrium {epsilon}{sub B} profile. Direct comparison of the measurements to a NIMROD simulation shows significant discrepancies, most likely due to artificially high-density diffusion used in the code for numerical stability. The first visible-light images of transient sawtooth crashes show the structure and location of the perturbed emission from an m=1 precursor oscillation and show that during the nonlinear crash phase the instability extends to more than half of the plasma minor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimentally-Derived Bidirectional Reflectance Distribution Function Data in Support of the Orbital Debris Program Office

The NASA Orbital Debris Program Office (ODPO) has used various optical assets to acquire photometric data of Earth-orbiting objects to define the orbital debris environment. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA Johnson Space Center emulates illumination conditions seen in space by using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. One of the OMC goals is to improve the size calculation used for optical data by developing an optical-based Size Estimation Model. The current size estimation requires applying a Lambertian phase function, a set albedo value, and range to the observed magnitude. The first step to improving the sampled brightness of laboratory targets is to remove aspect-angle dependencies. Then, the volume of possible object viewing angles is sampled at 21 combinations of azimuth and zenith angles for each solar phase angle. Finally, the acquired images are input into an image processing program that generates approximations for the object’s Bidirectional Reflectance Distribution Function (BRDF) and phase function. The BRDF is a radiometric concept that identifies an object’s material composition by matching a BRDF approximated with photometric data collected by ground-based telescopes with a BRDF generated experimentally from a known object in the laboratory. This paper discusses the validation of experimental BRDF and phase function approximations produced in the OMC and how the findings will be incorporated into ODPO models. A Lambertian sphere is imaged and the subsequent experimental functions are scrutinized to confirm that they correspond to an object that has an isotropic luminance. With the image processing algorithm validated, test objects with varying optical properties are then imaged to confirm that the produced photometric functions are both unique and repeatable. Once the validation is complete, the OMC will be used to evaluate a subset of fragments from a hypervelocity impact test of a mock-up satellite and assess the appropriate phase function and size estimates using BRDF measurements for a large volume of targets composed of various shapes, sizes, and materials.

Orbital Debris Program Office (ODPO)↗

Measurement of the quantum superposition state of an imaging ensemble of photons prepared in orbital angular momentum states using a phase-diversity method

We propose the use of a phase-diversity technique to estimate the orbital angular momentum (OAM) superposition state of an ensemble of photons that passes through an optical system, proceeding from an extended object. The phase-diversity technique permits the estimation of the optical transfer function (OTF) of an imaging optical system. As the OTF is derived directly from the wave-front characteristics of the observed light, we redefine the phase-diversity technique in terms of a superposition of OAM states. We test this new technique experimentally and find coherent results among different tests, which gives us confidence in the estimation of the photon ensemble state. We find that this technique not only allows us to estimate the square of the amplitude of each OAM state, but also the relative phases among all states, thus providing complete information about the quantum state of the photons. This technique could be used to measure the OAM spectrum of extended objects in astronomy or in an optical communication scheme using OAM states. In this sense, the use of extended images could lead to new techniques in which the communication is further multiplexed along the field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗