Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Influence of surface relaxation on solute atoms positioning within atom probe tomography reconstructions

Highlights: • APT measurement of Al/Cu alloy is simulated with a combined electrostatics and molecular dynamics (MD) approach. • Results show segregation of dilute Cu at [111] poles in correspondence to experimental measurements. • No temperature is involved. The effect originates in both disparate evaporation field and bond-energies in the alloy. While thermal or field-induced surface migration has been invoked often in past literature to rationalize the experimental observations of solute and impurity atoms segregation to specific poles and zones lines in atom probe tomography (APT) reconstructions, it does not satisfactorily explain all experimental results. Using a combined finite-element and molecular dynamics simulation approach that models the field evaporation process from mechanically relaxed emitter structures, we show that an additional mechanism, athermal relaxation, can also drive significant solute migration. The mechanism is illustrated for Cu in solid solution in Al, which exhibits segregation of Cu to 111 poles and along [110] zone lines in reconstructed APT data. The higher bonding energy of Cu atoms on the surface, confirmed using density-functional theory calculations, causes longer retention on the surface and preferential evaporation of neighboring Al atoms with subsequent athermal relaxation of Cu into higher-neighbor-count sites left vacant by evaporating Al neighbors. This in turn results in barrier-free long-range migration of the Cu atoms by a series of relaxation events that follow the receding terrace ledges towards high-neighbor count poles and zone lines. This mechanism fundamentally limits spatial resolution in the limit of zero temperature.

36 MATERIALS SCIENCE↗

On the relationships between electron spot size, focal spot size, and virtual source position in Monte Carlo simulations

Purpose: Every year, new radiotherapy techniques including stereotactic radiosurgery using linear accelerators give rise to new applications of Monte Carlo (MC) modeling. Accurate modeling requires knowing the size of the electron spot, one of the few parameters to tune in MC models. The resolution of integrated megavoltage imaging systems, such as the tomotherapy system, strongly depends on the photon spot size which is closely related to the electron spot. The aim of this article is to clarify the relationship between the electron spot size and the photon spot size (i.e., the focal spot size) for typical incident electron beam energies and target thicknesses. Methods: Three electron energies (3, 5.5, and 18 MeV), four electron spot sizes (FWHM=0, 0.5, 1, and 1.5 mm), and two tungsten target thicknesses (0.15 and 1 cm) were considered. The formation of the photon beam within the target was analyzed through electron energy deposition with depth, as well as photon production at several phase-space planes placed perpendicular to the beam axis, where only photons recorded for the first time were accounted for. Photon production was considered for ''newborn'' photons intersecting a 45x45 cm{sup 2} plane at the isocenter (85 cm from source). Finally, virtual source position and ''effective'' focal spot size were computed by backprojecting all the photons from the bottom of the target intersecting a 45x45 cm{sup 2} plane. The virtual source position and focal spot size were estimated at the plane position where the latter is minimal. Results: In the relevant case of considering only photons intersecting the 45x45 cm{sup 2} plane, the results unambiguously showed that the effective photon spot is created within the first 0.25 mm of the target and that electron and focal spots may be assumed to be equal within 3-4%. Conclusions: In a good approximation photon spot size equals electron spot size for high energy X-ray treatments delivered by linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural and Biochemical Studies on the Regulation of Biotin Carboxylase by Substrate Inhibition and Dimerization

Biotin carboxylase (BC) activity is shared among biotin-dependent carboxylases and catalyzes the Mg-ATP-dependent carboxylation of biotin using bicarbonate as the CO{sub 2} donor. BC has been studied extensively over the years by structural, kinetic, and mutagenesis analyses. Here we report three new crystal structures of Escherichia coli BC at up to 1.9 {angstrom} resolution, complexed with different ligands. Two structures are wild-type BC in complex with two ADP molecules and two Ca{sup 2+} ions or two ADP molecules and one Mg{sup 2+} ion. One ADP molecule is in the position normally taken by the ATP substrate, whereas the other ADP molecule occupies the binding sites of bicarbonate and biotin. One Ca{sup 2+} ion and the Mg{sup 2+} ion are associated with the ADP molecule in the active site, and the other Ca{sup 2+} ion is coordinated by Glu-87, Glu-288, and Asn-290. Our kinetic studies confirm that ATP shows substrate inhibition and that this inhibition is competitive against bicarbonate. The third structure is on the R16E mutant in complex with bicarbonate and Mg-ADP. Arg-16 is located near the dimer interface. The R16E mutant has only a 2-fold loss in catalytic activity compared with the wild-type enzyme. Analytical ultracentrifugation experiments showed that the mutation significantly destabilized the dimer, although the presence of substrates can induce dimer formation. The binding modes of bicarbonate and Mg-ADP are essentially the same as those to the wild-type enzyme. However, the mutation greatly disrupted the dimer interface and caused a large re-organization of the dimer. The structures of these new complexes have implications for the catalysis by BC.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH-SENSITIVITY ARRAY OBSERVATIONS OF THE z = 1.87 SUBMILLIMETER GALAXY GOODS 850-3

We present sensitive phase-referenced Very Long Baseline Interferometry (VLBI) results on the radio continuum emission from the z = 1.87 luminous submillimeter galaxy (SMG) GOODS 850-3. The observations were carried out at 1.4 GHz using the High-Sensitivity Array (HSA). Our sensitive tapered VLBI image of GOODS 850-3 at 0.''47 x 0.''34 (3.9 x 2.9 kpc) resolution shows a marginally resolved continuum structure with a peak flux density of 148 {+-} 38 {mu}Jy beam{sup -1}, and a total flux density of 168 {+-} 73 {mu}Jy, consistent with previous Very Large Array and MERLIN measurements. The deconvolved size of the source is 0.''27({+-}0.''12) x <0.''23, or 2.3({+-}1.0) x <1.9 kpc, and the derived intrinsic brightness temperature is >(5 {+-} 2) x 10{sup 3} K. The radio continuum position of this galaxy coincides with a bright and extended near-infrared source that nearly disappears in the deep Hubble Space Telescope optical image, indicating a dusty source of nearly 9 kpc in diameter. No continuum emission is detected at the full VLBI resolution (13.2 x 7.2 mas, 111 x 61 pc), with a 4{sigma} point source upper limit of 26 {mu}Jy beam{sup -1}, or an upper limit to the intrinsic brightness temperature of 4.7 x 10{sup 5} K. The extent of the observed continuum source at 1.4 GHz and the derived brightness temperature limits are consistent with the radio emission (and thus presumably the far-infrared emission) being powered by a major starburst in GOODS 850-3, with a star formation rate of {approx}2500 M {sub sun} yr{sup -1}. Moreover, the absence of any continuum emission at the full resolution of the VLBI observations indicates the lack of a compact radio-loud active galactic nucleus in this z = 1.87 SMG.

79 ASTRONOMY AND ASTROPHYSICS↗

Microfabrication of High Resolution X-ray Magnetic Calorimeters

Metallic magnetic calorimeter (MMC) is one of the most promising x-ray detector technologies for providing the very high energy resolution needed for future astronomical x-ray imaging spectroscopy. For this purpose, we have developed micro-fabricated 5x5 arrays of MMC of which each individual pixel has excellent energy resolution as good as 3.4 eV at 6 keV x-ray. Here we report on the fabrication techniques developed to achieve good resolution and high efficiency. These include: processing of a thin insulation layer for strong magnetic coupling between the AuEr sensor film and the niobium pick-up coil; production of overhanging absorbers for enhanced efficiency of x-ray absorption; fabrication on SiN membranes to minimize the effects on energy resolution from athermal phonon loss. We have also improved the deposition of the magnetic sensor film such that the film magnetization is nearly completely that is expected from the AuEr sputter target bulk material. In addition, we have included a study of a positional sensitive design, the Hydra design, which allows thermal coupling of four absorbers to a common MMC sensor and circuit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Percutaneous Treatment of Intrahepatic Biliary Leak: A Modified Occlusion Balloon Technique

PurposeTo report a novel modified occlusion balloon technique to treat biliary leaks.MethodsA 22-year-old female patient underwent liver transplantation with biliary-enteric anastomosis. She developed thrombosis of the common hepatic artery and extensive ischemia in the left hepatic lobe. Resection of segments II and III was performed and a biliary-cutaneous leak originating at the resection plane was identified in the early postoperative period. Initial treatment with percutaneous transhepatic drainage was unsuccessful. Therefore, an angioplasty balloon was coaxially inserted within the biliary drain and positioned close to the leak.ResultsThe fistula output abruptly decreased after the procedure and stopped on the 7th day. At the 3-week follow-up, cholangiography revealed complete resolution of the leakage.ConclusionThis novel modified occlusion balloon technique was effective and safe. However, greater experience and more cases are necessary to validate the technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging the atomic surface structures of CeO2 nanoparticles

Atomic surface structures of CeO2 nanoparticles are under debate owing to the lack of clear experimental determination of the positions of the surface oxygen atoms. Particularly controversial is the (100) surface structure of this material. In this study, with oxygen atoms clearly observed using aberration corrected high resolution electron microscopy, we determined the atomic structures of the (100), (110) and (111) surfaces of CeO2 nanocubes. The predominantly exposed (100) surface has a mixture of Ce, O, and reduced CeO terminations, underscoring the complex structures of this polar surface that previously was often oversimplified. The (110) surface shows saw-like (111) nanofacets and flat CeO2-x terminations with oxygen vacancies. The (111) surface has an O termination. As these three low index surfaces are the most often exposed facets in the majority of CeO2 nanoparticles, these findings can be extended to the surfaces of differently shaped CeO2 nanoparticles as well as provide insight about face-selective catalysis.

Lin, Yuyuan↗

Pore architecture and particulate organic matter in soils under monoculture switchgrass and restored prairie in contrasting topography

Bioenergy cropping systems can substantially contribute to climate change mitigation. However, limited information is available on how they affect soil characteristics, including pores and particulate organic matter (POM), both essential components of the soil C cycle. The objective of this study was to determine effects of bioenergy systems and field topography on soil pore characteristics, POM, and POM decomposition under new plant growth. We collected intact soil cores from two systems: monoculture switchgrass (Panicum virgatum L.) and native prairie, at two contrasting topographical positions (depressions and slopes), planting half of the cores with switchgrass. Pore and POM characteristics were obtained using X-ray computed micro-tomography (μCT) (18.2 µm resolution) before and after new switchgrass growth. Diverse prairie vegetation led to higher soil C than switchgrass, with concomitantly higher volumes of 30–90 μm radius pores and greater solid-pore interface. Yet, that effect was present only in the coarse-textured soils on slopes and coincided with higher root biomass of prairie vegetation. Surprisingly, new switchgrass growth did not intensify decomposition of POM, but even somewhat decreased it in monoculture switchgrass as compared to non-planted controls. Our results suggest that topography can play a substantial role in regulating factors driving C sequestration in bioenergy systems.

59 BASIC BIOLOGICAL SCIENCES↗

Dark-field X-ray microscopy with structured illumination for three-dimensional imaging

Dark-field X-ray microscopy is a lens-based technique that enables real-space imaging of heterogeneous micro- and meso-scale ordered materials. However, achieving accurate three-dimensional (3D) reconstruction often requires meticulous sample alignment or rastering, requiring complex rotational setups and extended acquisition times. To address these challenges, we introduce a structured illumination technique optimized for 3D imaging of ordered materials at sub-micrometer length scales. Our approach employs a coded aperture to spatially modulate the incident X-ray beam, enabling 3D structural reconstruction from images captured at various aperture positions. Unlike current 3D imaging approaches, which often rely on rotational or rastering methods, our technique uses scanning X-ray silhouettes of the coded aperture for depth resolution along the diffraction axis. This eliminates the need for sample rotation or rastering, resulting in a highly stable and efficient imaging modality. We validated the efficacy of this approach through experimental imaging of an isolated twin domain within a bulk single crystal of an iron pnictide using a dark-field X-ray microscope. This advancement aligns with the enhanced brightness upgrades of modern synchrotron radiation facilities, unlocking new possibilities for high-resolution imaging of ordered materials.

47 OTHER INSTRUMENTATION↗

Stabilization of sample temperature in a surface-science vacuum chamber to 0.03 K and quartz-crystal microbalance frequency to 0.06 Hz over 0.5 h

Improvements have been made to a high-stability quartz-crystal microbalance for use in a typical surface-science, ultrahigh vacuum chamber, with a frequency stability of one part in 10{sup 8} (0.06 Hz) over 0.5 h. This gives a resolution equivalent to 2% of an atomic monolayer of oxygen over 0.5 h. The quartz-crystal microbalance (QCM) crystal can be rotated to different surface-analysis positions in the chamber. These characteristics open up the combination of surface and bulk adsorption studies on the same sample without transferring the sample to another chamber. To accomplish this, it was necessary to stabilize the sample temperature to {+-}0.03 K over several hours. The oscillator performance is illustrated by the uptake of oxygen by a gold-plated QCM crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatic potential mapping at ferroelectric domain walls by low-temperature photoemission electron microscopy

Low-temperature X-ray photoemission electron microscopy (X-PEEM) is used to measure the electric potential at domain walls in improper ferroelectric Er 0.99 Ca 0.01 MnO 3 . Here, by combining X-PEEM with scanning probe microscopy and theory, we develop a model that relates the detected X-PEEM contrast to the emergence of uncompensated bound charges, explaining the image formation based on intrinsic electronic domain-wall properties. In contrast to previously applied low-temperature electrostatic force microscopy (EFM), X-PEEM readily distinguishes between positive and negative bound charges at domain walls. Finally, our study introduces an X-PEEM-based approach for low-temperature electrostatic potential mapping, facilitating nanoscale spatial resolution and data acquisition times on the order of 0.1-1 s.

36 MATERIALS SCIENCE↗

PROBING THE MASS-LOSS HISTORY OF THE YELLOW HYPERGIANT IRC+10420

We have used the submillimeter array to image the molecular envelope around the yellow hypergiant IRC+10420. Our observations reveal a large and clumpy expanding envelope around the star. The molecular envelope shows a clear asymmetry in {sup 12}CO J = 2-1 emission in the southwest direction. The elongation of the envelope is found even more pronounced in the emission of {sup 13}CO J = 2-1 and SO J {sub K} = 6{sub 5}-5{sub 4}. A small positional velocity gradient across velocity channels is seen in these lines, suggesting the presence of a weak bipolar outflow in the envelope of IRC+10420. In the higher resolution {sup 12}CO J = 2-1 map, we find that the envelope has two components: (1) an inner shell (shell I) located between radius of about 1'' and 2''; (2) an outer shell (shell II) located between 3'' and 6'' in radius. These shells represent two previous mass-loss episodes from IRC+10420. We attempt to derive in self-consistent manner the physical conditions inside the envelope by modeling the dust properties, and the heating and cooling of molecular gas. We estimate a mass-loss rate of {approx}9 x 10{sup -4} M {sub sun} yr{sup -1} for shell I and 7 x 10{sup -4} M {sub sun} yr{sup -1} for shell II. The gas temperature is found to be unusually high in IRC+10420 in comparison with other oxygen-rich envelopes. The elevated gas temperature is mainly due to higher heating rate, which results from the large luminosity of the central star. We also derive an isotopic ratio {sup 12}C/{sup 13}C = 6.

79 ASTRONOMY AND ASTROPHYSICS↗

RADIO AND X-RAY PROPERTIES OF SUBMILLIMETER GALAXIES IN THE A2125 FIELD

We present the radio and X-ray properties of 1.2 mm MAMBO source candidates in a 1600 arcmin{sup 2} field centered on the Abell 2125 galaxy cluster at z = 0.247. The brightest, nonsynchrotron millimeter source candidate in the field has a photometric redshift z = 3.93{sup +1.11}{sub -0.80} and is not detected in a 31 ks Chandra X-ray exposure. These findings are consistent with this object being an extremely dusty and luminous starburst galaxy at high redshift, possibly the most luminous yet identified in any blank-field millimeter survey. The deep 1.4 GHz Very Large Array imaging identifies counterparts for 83% of the 29 mm source candidates identified at {>=}4{sigma} (S{sub 1.2mm} = 2.7-52.1 mJy), implying that the majority of these objects are likely to lie at z {approx}< 3.5. The median millimeter-to-radio wavelength photometric redshift of this radio-detected sample is z {approx} 2.2 (first and third quartiles of 1.7 and 3.0), consistent with the median redshift derived from optical spectroscopic surveys of the radio-detected subsample of bright submillimeter galaxies (S{sub 850{mu}}{sub m} > 5 mJy). Three millimeter-selected quasars are confirmed to be X-ray luminous in the high-resolution Chandra imaging, while another millimeter source candidate with potential multiple radio counterparts is also detected in the X-ray regime. Both of these radio counterparts are positionally consistent with the millimeter source candidate. One counterpart is associated with an elliptical galaxy at z = 0.2425, but we believe that a second counterpart associated with a fainter optical source likely gives rise to the millimeter emission at z {approx} 1.

99 GENERAL AND MISCELLANEOUS↗

SNR 0104-72.3: A REMNANT OF A TYPE Ia SUPERNOVA IN A STAR-FORMING REGION?

We report our 110 ks Chandra observations of the supernova remnant (SNR) 0104-72.3 in the Small Magellanic Cloud (SMC). The X-ray morphology shows two prominent lobes along the northwest-southeast direction and a soft faint arc in the east. Previous low-resolution X-ray images attributed the unresolved emission from the southeastern lobe to a Be/X-ray star. Our high-resolution Chandra data clearly show that this emission is diffuse, shock-heated plasma, with negligible X-ray emission from the Be star. The eastern arc is positionally coincident with a filament seen in optical and infrared observations. Its X-ray spectrum is well fit by plasma of normal SMC abundances, suggesting that it is from shocked ambient gas. The X-ray spectra of the lobes show overabundant Fe, which is interpreted as emission from the reverse-shocked Fe-rich ejecta. The overall spectral characteristics of the lobes and the arc are similar to those of Type Ia SNRs, and we propose that SNR 0104-72.3 is the first case for a robust candidate Type Ia SNR in the SMC. On the other hand, the remnant appears to be interacting with dense clouds toward the east and to be associated with a nearby star-forming region. These features are unusual for a standard Type Ia SNR. Our results suggest an intriguing possibility that the progenitor of SNR 0104-72.3 might have been a white dwarf of a relatively young population.

79 ASTRONOMY AND ASTROPHYSICS↗

Flat space S matrix from the AdS/CFT correspondence?

We investigate recovery of the bulk S matrix from the AdS/CFT correspondence, at large radius. It was recently argued that some of the elements of the S matrix might be read from CFT correlators, given a particular singularity structure of the latter, but leaving the question of more general S matrix elements. Since in AdS/CFT, data must be specified on the boundary, we find certain limitations on the corresponding bulk wave packets and on their localization properties. In particular, those we have found that approximately localize have low-energy tails, and corresponding power-law tails in position space. When their scattering is compared to that of 'sharper' wave packets typically used in scattering theory, one finds apparently significant differences, suggesting a possible lack of resolution via these wave packets. We also give arguments that construction of the sharper wave packets may require nonperturbative control of the boundary theory, and particularly of the N{sup 2} matrix degrees of freedom. These observations thus raise interesting questions about what principle would guarantee the appropriate control, and about how a boundary CFT can accurately approximate the flat space S matrix.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗