Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

A Randomized Phase 2 Trial of Prophylactic Manuka Honey for the Reduction of Chemoradiation Therapy–Induced Esophagitis During the Treatment of Lung Cancer: Results of NRG Oncology RTOG 1012

Purpose: Randomized trials have shown that honey is effective for the prevention of radiation-induced mucositis in head and neck cancer patients. Because there is no efficacious preventative for radiation esophagitis in lung cancer patients, this trial compared liquid honey, honey lozenges, and standard supportive care for radiation esophagitis. Methods: The patients were stratified by percentage of esophagus receiving specific radiation dose (V60 Gy esophagus <30% or ≥30%) and were then randomized between supportive care, 10 mL of liquid manuka honey 4 times a day, and 2 lozenges (10 mL of dehydrated manuka honey) 4 times a day during concurrent chemotherapy and radiation therapy. The primary endpoint was patient-reported pain on swallowing, with the use of an 11-point (0-10) scale at 4 weeks (Numerical Rating Pain Scale, NRPS). The study was designed to detect a 15% relative reduction of change in NRPS score. The secondary endpoints were trend of pain over time, opioid use, clinically graded and patient-reported adverse events, weight loss, dysphagia, nutritional status, and quality of life. Results: 53 patients were randomized to supportive care, 54 were randomized to liquid honey, and 56 were randomized to lozenge honey. There was no significant difference in the primary endpoint of change in the NRPS at 4 weeks between arms. There were no differences in any of the secondary endpoints except for opioid use at 4 weeks during treatment between the supportive care and liquid honey arms, which was found to be significant (P=.03), with more patients on the supportive care arm taking opioids. Conclusion: Honey as prescribed within this protocol was not superior to best supportive care in preventing radiation esophagitis. Further testing of other types of honey and research into the mechanisms of action are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-guided intensity-modulated radiotherapy for prostate cancer: Dose constraints for the anterior rectal wall to minimize rectal toxicity

Rectal adverse events (AEs) are a major concern with definitive radiotherapy (RT) treatment for prostate cancer. The anterior rectal wall is at the greatest risk of injury as it lies closest to the target volume and receives the highest dose of RT. This study evaluated the absolute volume of anterior rectal wall receiving a high dose to identify potential ideal dose constraints that can minimize rectal AEs. A total of 111 consecutive patients with Stage T1c to T3a N0 M0 prostate cancer who underwent image-guided intensity-modulated RT at our institution were included. AEs were graded according to the Common Terminology Criteria for Adverse Events, version 4.0. The volume of anterior rectal wall receiving 5 to 80 Gy in 2.5-Gy increments was determined. Multivariable Cox regression models were used to identify cut points in these volumes that led to an increased risk of early and late rectal AEs. Early AEs occurred in most patients (88%); however, relatively few of them (13%) were grade ≥2. At 5 years, the cumulative incidence of late rectal AEs was 37%, with only 5% being grade ≥2. For almost all RT doses, we identified a threshold of irradiated absolute volume of anterior rectal wall above which there was at least a trend toward a significantly higher rate of AEs. Most strikingly, patients with more than 1.29, 0.73, or 0.45 cm{sup 3} of anterior rectal wall exposed to radiation doses of 67.5, 70, or 72.5 Gy, respectively, had a significantly increased risk of late AEs (relative risks [RR]: 2.18 to 2.72; p ≤ 0.041) and of grade ≥ 2 early AEs (RR: 6.36 to 6.48; p = 0.004). Our study provides evidence that definitive image-guided intensity-modulated radiotherapy (IG-IMRT) for prostate cancer is well tolerated and also identifies dose thresholds for the absolute volume of anterior rectal wall above which patients are at greater risk of early and late complications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Frequency Distribution of Second Solid Cancer Locations in Relation to the Irradiated Volume Among 115 Patients Treated for Childhood Cancer

Purpose: To provide better estimates of the frequency distribution of second malignant neoplasm (SMN) sites in relation to previous irradiated volumes, and better estimates of the doses delivered to these sites during radiotherapy (RT) of the first malignant neoplasm (FMN). Methods and Materials: The study focused on 115 patients who developed a solid SMN among a cohort of 4581 individuals. The homemade software package Dos{sub E}G was used to estimate the radiation doses delivered to SMN sites during RT of the FMN. Three-dimensional geometry was used to evaluate the distances between the irradiated volume, for RT delivered to each FMN, and the site of the subsequent SMN. Results: The spatial distribution of SMN relative to the irradiated volumes in our cohort was as follows: 12% in the central area of the irradiated volume, which corresponds to the planning target volume (PTV), 66% in the beam-bordering region (i.e., the area surrounding the PTV), and 22% in regions located more than 5 cm from the irradiated volume. At the SMN site, all dose levels ranging from almost zero to >75 Gy were represented. A peak SMN frequency of approximately 31% was identified in volumes that received <2.5 Gy. Conclusion: A greater volume of tissues receives low or intermediate doses in regions bordering the irradiated volume with modern multiple-beam RT arrangements. These results should be considered for risk-benefit evaluations of RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Parameters and Clinical Factors Associated With Pleural Effusion After Chemoradiotherapy in Esophageal Cancer Patients

Purpose: To investigate the dose-volume histogram parameters and clinical factors as predictors of pleural effusion in esophageal cancer patients treated with concurrent chemoradiotherapy (CRT). Methods and Materials: Forty-three esophageal cancer patients treated with definitive CRT from January 2001 to March 2007 were reviewed retrospectively on the basis of the following criteria: pathologically confirmed esophageal cancer, available computed tomography scan for treatment planning, 6-month follow-up after CRT, and radiation dose {>=}50 Gy. Exclusion criteria were lung metastasis, malignant pleural effusion, and surgery. Mean heart dose, mean total lung dose, and percentages of heart or total lung volume receiving {>=}10-60 Gy (Heart-V{sub 10} to V{sub 60} and Lung-V{sub 10} to V{sub 60}, respectively) were analyzed in relation to pleural effusion. Results: The median follow-up time was 26.9 months (range, 6.7-70.2) after CRT. Of the 43 patients, 15 (35%) developed pleural effusion. By univariate analysis, mean heart dose, Heart-V{sub 10} to V{sub 60}, and Lung-V{sub 50} to V{sub 60} were significantly associated with pleural effusion. Poor performance status, primary tumor of the distal esophagus, and age {>=}65 years were significantly related with pleural effusion. Multivariate analysis identified Heart-V{sub 50} as the strongest predictive factor for pleural effusion (p = 0.01). Patients with Heart-V{sub 50} <20%, 20%{<=} Heart-V{sub 50} <40%, and Heart-V{sub 50} {>=}40% had 6%, 44%, and 64% of pleural effusion, respectively (p < 0.01). Conclusion: Heart-V{sub 50} is a useful parameter for assessing the risk of pleural effusion and should be reduced to avoid pleural effusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-extensive radiobiology

The expression of survival factors for radiation damaged cells is based on probabilistic assumptions and experimentally fitted for each tumor, radiation and conditions. Here we show how the simplest of these radiobiological models can be derived from the maximum entropy principle of the classical Boltzmann-Gibbs expression. We extend this derivation using the Tsallis entropy and a cutoff hypothesis, motivated by clinical observations. A generalization of the exponential, the logarithm and the product to a non-extensive framework, provides a simple formula for the survival fraction corresponding to the application of several radiation doses on a living tissue. The obtained expression shows a remarkable agreement with the experimental data found in the literature, also providing a new interpretation of some of the parameters introduced anew. It is also shown how the presented formalism may have direct application in radiotherapy treatment optimization through the definition of the potential effect difference, simply calculated between the tumour and the surrounding tissue.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SU-E-QI-12: Morphometry Based Measurements of the Structural Response to Whole Brain Radiation

Purpose: Although state of the art radiation therapy techniques for treating intracranial malignancies have eliminated acute brain injury, cognitive impairment occurs in 50–90% of patients who survive >6mo post irradiation. Quantitative characterization of therapy response is needed to facilitate therapeutic strategies to minimize radiation induced cognitive impairment [1]. Deformation based morphometry techniques [2, 3] are presented as a quantitative imaging biomarker of therapy response in patients receiving whole brain radiation for treating medulloblastoma. Methods: Post-irradiation magnetic resonance imaging (MRI) data sets were retrospectively analyzed in N=15 patients, >60 MR image datasets. As seen in Fig 1(a), volume changes at multiple time points post-irradiation were quantitatively measured in the cerebrum and ventricles with respect to pre-irradiation MRI. A high resolution image Template, was registered to the pre-irradiation MRI of each patient to create a brain atlas for the cerebrum, cerebellum, and ventricles. Skull stripped images for each patient were registered to the initial pre-treatment scan. Average volume changes in the labeled regions were measured using the determinant of the displacement field Jacobian. Results: Longitudinal measurements, Fig 1(b-c), show a negative correlation p=.06, of the cerebral volume change with the time interval from irradiation. A corresponding positive correlation, p=.01, between ventricular volume change and time interval from irradiation is seen. One sample t-test for correlations were computed using a Spearman method. An average decrease in cerebral volume, p=.08, and increase in ventricular volume, p<.001, was observed. The radiation dose was seen directly proportional to the induced volume changes in the cerebrum, r=−.44, p<.001, Fig 1(d). Conclusion: Results indicate that morphometric monitoring of brain tissue volume changes may potentially be used to quantitatively assess toxicity and response to radiation and may provide insight in developing new therapeutic approaches and monitoring efficacy.

60 APPLIED LIFE SCIENCES↗

Systems and methods for imaging using radiation from laser produced plasmas

In particular embodiments, the present disclosure provides systems and methods for imaging a subject using radiation emitted from a laser produced plasma generating by irradiating a target with a laser. In particular examples, the target includes at least one radiation enhancing component, such as a fluor, cap, or wire. In further examples, the target has a metal layer and an internal surface defining an internal apex, the internal apex of less than about 15 .mu.m, such as less than about 1 .mu.m. The targets may take a variety of shapes, including cones, pyramids, and hemispheres. Certain aspects of the present disclosure provide improved imaging of a subject, such as improved medical images of a radiation dose than typical conventional methods and systems.

47 OTHER INSTRUMENTATION↗

SU-E-T-776: Use of Quality Metrics for a New Hypo-Fractionated Pre-Surgical Mesothelioma Protocol

Purpose: The “SMART” (Surgery for Mesothelioma After Radiation Therapy) approach involves hypo-fractionated radiotherapy of the lung pleura to 25Gy over 5 days followed by surgical resection within 7. Early clinical results suggest that this approach is very promising, but also logistically challenging due to the multidisciplinary involvement. Due to the compressed schedule, high dose, and shortened planning time, the delivery of the planned doses were monitored for safety with quality metric software. Methods: Hypo-fractionated IMRT treatment plans were developed for all patients and exported to Quality Reports™ software. Plan quality metrics or PQMs™ were created to calculate an objective scoring function for each plan. This allows for an objective assessment of the quality of the plan and a benchmark for plan improvement for subsequent patients. The priorities of various components were incorporated based on similar hypo-fractionated protocols such as lung SBRT treatments. Results: Five patients have been treated at our institution using this approach. The plans were developed, QA performed, and ready within 5 days of simulation. Plan Quality metrics utilized in scoring included doses to OAR and target coverage. All patients tolerated treatment well and proceeded to surgery as scheduled. Reported toxicity included grade 1 nausea (n=1), grade 1 esophagitis (n=1), grade 2 fatigue (n=3). One patient had recurrent fluid accumulation following surgery. No patients experienced any pulmonary toxicity prior to surgery. Conclusion: An accelerated course of pre-operative high dose radiation for mesothelioma is an innovative and promising new protocol. Without historical data, one must proceed cautiously and monitor the data carefully. The development of quality metrics and scoring functions for these treatments allows us to benchmark our plans and monitor improvement. If subsequent toxicities occur, these will be easy to investigate and incorporate into the metrics. This will improve the safe delivery of large doses for these patients.

60 APPLIED LIFE SCIENCES↗

Diffusion Tensor Magnetic Resonance Imaging Finding of Discrepant Fractional Anisotropy Between the Frontal and Parietal Lobes After Whole-Brain Irradiation in Childhood Medulloblastoma Survivors: Reflection of Regional White Matter Radiosensitivity?

Purpose: To test the hypothesis that fractional anisotropy (FA) is more severely reduced in white matter of the frontal lobe compared with the parietal lobe after receiving the same whole-brain irradiation dose in a cohort of childhood medulloblastoma survivors. Methods and Materials: Twenty-two medulloblastoma survivors (15 male, mean [{+-} SD] age = 12.1 {+-} 4.6 years) and the same number of control subjects (15 male, aged 12.0 {+-} 4.2 years) were recruited for diffusion tensor magnetic resonance imaging scans. Using an automated tissue classification method and the Talairach Daemon atlas, FA values of frontal and parietal lobes receiving the same radiation dose, and the ratio between them were quantified and denoted as FFA, PFA, and FA{sub f/p}, respectively. The Mann-Whitney U test was used to test for significant differences of FFA, PFA, and FA{sub f/p} between medulloblastoma survivors and control subjects. Results: Frontal lobe and parietal lobe white matter FA were found to be significantly less in medulloblastoma survivors compared with control subjects (frontal p = 0.001, parietal p = 0.026). Moreover, these differences were found to be discrepant, with the frontal lobe having a significantly larger difference in FA compared with the parietal lobe. The FA{sub f/p} of control and medulloblastoma survivors was 1.110 and 1.082, respectively (p = 0.029). Conclusion: Discrepant FA changes after the same irradiation dose suggest radiosensitivity of the frontal lobe white matter compared with the parietal lobe. Special efforts to address the potentially vulnerable frontal lobe after treatment with whole-brain radiation may be needed so as to balance disease control and treatment-related morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Code of Radiation Damage by Gamma - Paper 62

In recent years, the study of radiation damage of materials has seen a thrust because of the expectation of the high rate of radiation damage in fusion reactors, accelerator driven sub critical systems and damage of a control system of space vehicles by the high energy neutrons and gamma showers. Embrittlement of reactor vessels, corrosion of steel and swelling of fuel rods are the well known empirical examples of severe radiation damage. It is also realized that damage by high energy gammas is in no way insignificant, and it is equivalent to the damage by the neutrons. Secondly, value addition of certain materials like enhancement of electrical resistance, mechanical strength, color enhancement of precious stones on irradiation by neutrons and gammas and polymerization in the presence of gamma radiation add to the necessity of a Monte Carlo (MC) code of radiation damage in a wide range of energy. The JAIPU code, for the study of radiation damage by neutrons up to 10 MeV energy, incorporates features like development of secondary atomic cascade and PKA energy corrected for the ionization lose and production of Frenkel pair. MC estimation of both the primary and secondary displacements has been compared with the Frenkel pairs calculated using the NRT model. In the present work, JAIPU code is extended for irradiation of materials by high energy gammas. Here cascade generated by the incident gamma produces electrons by way of photo-electric, Compton and pair production until it is absorbed. The recoiled Frenkel pairs produced in electron + atom collision have been considered for the purpose of atomic cascade. Standard cross section libraries for gamma and electron interaction are used while for atom + atom collision we have made use of the IOTA code. In addition, in the code, the lattice structure of the irradiated material is simulated to know the positions of the photon interactions with atoms and the energy of electron it adds an extra feature of the position and size of the voids and the clusters produced on irradiation. The code has the possibility of calculation of 'absorbed radiation dose' and 'KERMA' and the interatomic distances of the displaced atoms. It may be pointed out that the code uses only the MC simulation of the number of displacements unlike several other approaches where the NRT model with PKA energy is used for gross estimation of the number of the displaced atoms. Thus, the code keeps an account of the positions of displaced atoms for the in-depth modification of the irradiated material. 1 MeV gamma seems to damage Fe up to several millimeters of its depth and this is mostly by the recoiled Compton electrons than photo electrons. The code is in the developmental stage and it has the capability of applications in the developing field of Radiology besides the shielding and other studies of radiation damage. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Four-Dimensional Computed Tomography-Based Intensity-Modulated and Respiratory-Gated Radiotherapy Techniques for Pancreatic Carcinoma

Purpose: To compare conformal radiotherapy (CRT), intensity-modulated radiotherapy (IMRT), and respiration-gated radiotherapy (RGRT) planning techniques for pancreatic cancer. All target volumes were determined using four-dimensional computed tomography scans (4D CT). Methods and Materials: The pancreatic tumor and enlarged regional lymph nodes were contoured on all 10 phases of a planning 4D CT scan for 10 patients, and the planning target volumes (PTV{sub allphases}) were generated. Three consecutive respiratory phases for RGRT delivery in both inspiration and expiration were identified, and the corresponding PTVs (PTV{sub inspiration} and PTV{sub expiration}) and organ at risk volumes created. Treatment plans using CRT and IMRT, with and without RGRT, were created for each PTV. Results: Compared with the CRT plans, IMRT significantly reduced the mean volume of right kidney exposed to 20 Gy from 27.7% {+-} 17.7% to 16.0% {+-} 18.2% (standard deviation) (p < 0.01), but this was not achieved for the left kidney (11.1% {+-} 14.2% to 5.7% {+-} 6.5%; p = 0.1). The IMRT plans also reduced the mean gastric, hepatic, and small bowel doses (p < 0.01). No additional reductions in the dose to the kidneys or other organs at risk were seen when RGRT plans were combined with either CRT or IMRT, and the findings for RGRT in end-expiration and end-inspiration were similar. Conclusion: 4D CT-based IMRT plans for pancreatic tumors significantly reduced the radiation doses to the right kidney, liver, stomach, and small bowel compared with CRT plans. The additional dosimetric benefits from RGRT appear limited in this setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2021

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2021. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 Version 4.1 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

Argonne National Laboratory Site Environmental Report for Calendar Year 2023

This report discusses the status and the accomplishments of the environmental protection program at Argonne National Laboratory for calendar year 2023. The status of Argonne environmental protection activities with respect to compliance with the various laws and regulations is discussed, along with environmental management, sustainability efforts, environmental corrective actions, and habitat restoration. To evaluate the effects of Argonne operations on the environment, samples of environmental media collected on the site, at the site boundary, and off the Argonne site were analyzed and compared with applicable guidelines and standards. A variety of radionuclides were measured in air, surface water, groundwater, and bottom sediment samples. In addition, chemical constituents in surface water, groundwater, and wastewater were analyzed. External penetrating radiation doses were measured, and the potential for radiation exposure to off site population groups was estimated. Results are interpreted with respect to the origin of the radioactive and chemical substances (i.e., natural, Argonne, and other) and are compared with applicable standards intended to protect human health and the environment. A U.S. Department of Energy (DOE) dose calculation methodology, based on International Commission on Radiological Protection (ICRP) recommendations and the U.S. Environmental Protection Agency’s (EPA) CAP 88 computer code, was used in preparing this report.

54 ENVIRONMENTAL SCIENCES↗

Skin dose mapping for fluoroscopically guided interventions

Purpose: To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. Methods: In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Results: Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. Conclusions: The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

A set of 4D pediatric XCAT reference phantoms for multimodality research

Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models for the cardiac and respiratory motions. Based on patient data, the phantoms capture the anatomic variations of childhood, such as the development of bone in the skull, pelvis, and long bones, and the growth of the vertebrae and organs. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: The development of patient-derived pediatric computational phantoms is useful in providing variable anatomies for simulation. Future work will expand this ten-phantom base to a host of pediatric phantoms representative of the public at large. This can provide a means to evaluate and improve pediatric imaging devices and to optimize CT protocols in terms of image quality and radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

A minimum spanning forest based classification method for dedicated breast CT images

Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting model used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging.

60 APPLIED LIFE SCIENCES↗

TH-B-207B-00: Pediatric Image Quality Optimization

This imaging educational program will focus on solutions to common pediatric image quality optimization challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children’s hospitals. One of the most commonly encountered pediatric imaging requirements for the non-specialist hospital is pediatric CT in the emergency room setting. Thus, this educational program will begin with optimization of pediatric CT in the emergency department. Though pediatric cardiovascular MRI may be less common in the non-specialist hospitals, low pediatric volumes and unique cardiovascular anatomy make optimization of these techniques difficult. Therefore, our second speaker will review best practices in pediatric cardiovascular MRI based on experiences from a children’s hospital with a large volume of cardiac patients. Learning Objectives: To learn techniques for optimizing radiation dose and image quality for CT of children in the emergency room setting. To learn solutions for consistently high quality cardiovascular MRI of children.

60 APPLIED LIFE SCIENCES↗