Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ranking methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data

Purpose: The authors previously reported on a three-dimensional computer-generated breast phantom, based on empirical human image data, including a realistic finite-element based compression model that was capable of simulating multimodality imaging data. The computerized breast phantoms are a hybrid of two phantom generation techniques, combining empirical breast CT (bCT) data with flexible computer graphics techniques. However, to date, these phantoms have been based on single human subjects. In this paper, the authors report on a new method to generate multiple phantoms, simulating additional subjects from the limited set of original dedicated breast CT data. The authors developed an image morphing technique to construct new phantoms by gradually transitioning between two human subject datasets, with the potential to generate hundreds of additional pseudoindependent phantoms from the limited bCT cases. The authors conducted a preliminary subjective assessment with a limited number of observers (n= 4) to illustrate how realistic the simulated images generated with the pseudoindependent phantoms appeared. Methods: Several mesh-based geometric transformations were developed to generate distorted breast datasets from the original human subject data. Segmented bCT data from two different human subjects were used as the 'base' and 'target' for morphing. Several combinations of transformations were applied to morph between the 'base' and 'target' datasets such as changing the breast shape, rotating the glandular data, and changing the distribution of the glandular tissue. Following the morphing, regions of skin and fat were assigned to the morphed dataset in order to appropriately assign mechanical properties during the compression simulation. The resulting morphed breast was compressed using a finite element algorithm and simulated mammograms were generated using techniques described previously. Sixty-two simulated mammograms, generated from morphing three human subject datasets, were used in a preliminary observer evaluation where four board certified breast radiologists with varying amounts of experience ranked the level of realism (from 1 ='fake' to 10 ='real') of the simulated images. Results: The morphing technique was able to successfully generate new and unique morphed datasets from the original human subject data. The radiologists evaluated the realism of simulated mammograms generated from the morphed and unmorphed human subject datasets and scored the realism with an average ranking of 5.87 {+-} 1.99, confirming that overall the phantom image datasets appeared more 'real' than 'fake.' Moreover, there was not a significant difference (p > 0.1) between the realism of the unmorphed datasets (6.0 {+-} 1.95) compared to the morphed datasets (5.86 {+-} 1.99). Three of the four observers had overall average rankings of 6.89 {+-} 0.89, 6.9 {+-} 1.24, 6.76 {+-} 1.22, whereas the fourth observer ranked them noticeably lower at 2.94 {+-} 0.7. Conclusions: This work presents a technique that can be used to generate a suite of realistic computerized breast phantoms from a limited number of human subjects. This suite of flexible breast phantoms can be used for multimodality imaging research to provide a known truth while concurrently producing realistic simulated imaging data.

60 APPLIED LIFE SCIENCES↗

SU-E-J-226: Propagation of Pancreas Target Contours On Respiratory Correlated CT Images Using Deformable Image Registration

Purpose: Respiratory Correlated CT (RCCT) scans to assess intra-fraction motion among pancreatic cancer patients undergoing radiotherapy allow for dose sparing of normal tissues, in particular for the duodenum. Contour propagation of the gross tumor volume (GTV) from one reference respiratory phase to 9 other phases is time consuming. Deformable image registration (DIR) has been successfully used for high contrast disease sites but lower contrast for pancreatic tumors may compromise accuracy. This study evaluates the accuracy of Fast Free Form (FFF) registration-based contour propagation of the GTV on RCCT scans of pancreas cancer patients. Methods: Twenty-four pancreatic cancer patients were retrospectively studied; 20 had tumors in the pancreatic head/neck, 4 in the body/tail. Patients were simulated with RCCT and images were sorted into 10 respiratory phases. A radiation oncologist manually delineated the GTV for 5 phases (0%, 30%, 50%, 70% and 90%). The FFF algorithm was used to map deformations between the EE (50%) phase and each of the other 4 phases. The resultant deformation fields served to propagate GTV contours from EE to the other phases. The Dice Similarity Coefficient (DSC), which measures agreement between the DIR-propagated and manually-delineated GTVs, was used to quantitatively examine DIR accuracy. Results: Average DSC over all scans and patients is 0.82 and standard deviation is 0.09 (DSC range 0.97–0.57). For GTV volumes above and below the median volume of 20.2 cc, a Wilcoxon rank-sum test shows significantly different DSC (p=0.0000002). For the GTVs above the median volume, average +/− SD is 0.85 +/− 0.07; and for the GTVs below, the average +/− SD is 0.75 +/−0.08. Conclusion: For pancreatic tumors, the FFF DIR algorithm accurately propagated the GTV between the images in different phases of RCCT, with improved performance for larger tumors.

60 APPLIED LIFE SCIENCES↗

Improving the Accuracy of Nearest-Neighbor Classification Using Principled Construction and Stochastic Sampling of Training-Set Centroids

A conceptually simple way to classify images is to directly compare test-set data and training-set data. The accuracy of this approach is limited by the method of comparison used, and by the extent to which the training-set data cover configuration space. Here we show that this coverage can be substantially increased using coarse-graining (replacing groups of images by their centroids) and stochastic sampling (using distinct sets of centroids in combination). We use the MNIST and Fashion-MNIST data sets to show that a principled coarse-graining algorithm can convert training images into fewer image centroids without loss of accuracy of classification of test-set images by nearest-neighbor classification. Distinct batches of centroids can be used in combination as a means of stochastically sampling configuration space, and can classify test-set data more accurately than can the unaltered training set. On the MNIST and Fashion-MNIST data sets this approach converts nearest-neighbor classification from a mid-ranking- to an upper-ranking member of the set of classical machine-learning techniques.

97 MATHEMATICS AND COMPUTING↗

Ductal Carcinoma in Situ-The Influence of the Radiotherapy Boost on Local Control

Purpose: Local recurrence (LR) of ductal carcinoma in situ (DCIS) is reduced by whole-breast irradiation after breast-conserving surgery (BCS). However, the benefit of adding a radiotherapy boost to the surgical cavity for DCIS is unclear. We sought to determine the impact of the boost on LR in patients with DCIS treated at the McGill University Health Centre. Methods and Materials: A total of 220 consecutive cases of DCIS treated with BCS and radiotherapy between January 2000 and December 2006 were reviewed. Of the patients, 36% received a radiotherapy boost to the surgical cavity. Median follow-up was 46 months for the boost and no-boost groups. Kaplan-Meier survival analyses and Cox regression analyses were performed. Results: Compared with the no-boost group, patients in the boost group more frequently had positive and <0.1-cm margins (48% vs. 8%) (p < 0.0001) and more frequently were in higher-risk categories as defined by the Van Nuys Prognostic (VNP) index (p = 0.006). Despite being at higher risk for LR, none (0/79) of the patients who received a boost experienced LR, whereas 8 of 141 patients who did not receive a boost experienced an in-breast LR (log-rank p = 0.03). Univariate analysis of prognostic factors (age, tumor size, margin status, histological grade, necrosis, and VNP risk category) revealed only the presence of necrosis to significantly correlate with LR (log-rank p = 0.003). The whole-breast irradiation dose and fractionation schedule did not affect LR rate. Conclusions: Our results suggest that the use of a radiotherapy boost improves local control in DCIS and may outweigh the poor prognostic effect of necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early-Stage Primary Bone Lymphoma: A Retrospective, Multicenter Rare Cancer Network (RCN) Study

Purpose: Primary bone lymphoma (PBL) represents less than 1% of all malignant lymphomas. In this study, we assessed the disease profile, outcome, and prognostic factors in patients with Stages I and II PBL. Patients and Methods: Thirteen Rare Cancer Network (RCN) institutions enrolled 116 consecutive patients with PBL treated between 1987 and 2008 in this study. Eighty-seven patients underwent chemoradiotherapy (CXRT) without (78) or with (9) surgery, 15 radiotherapy (RT) without (13) or with (2) surgery, and 14 chemotherapy (CXT) without (9) or with (5) surgery. Median RT dose was 40 Gy (range, 4-60). The median number of CXT cycles was six (range, 2-8). Median follow-up was 41 months (range, 6-242). Results: The overall response rate at the end of treatment was 91% (complete response [CR] 74%, partial response [PR] 17%). Local recurrence or progression was observed in 12 (10%) patients and systemic recurrence in 17 (15%). The 5-year overall survival (OS), lymphoma-specific survival (LSS), and local control (LC) were 76%, 78%, and 92%, respectively. In univariate analyses (log-rank test), favorable prognostic factors for OS and LSS were International Prognostic Index (IPI) score {<=}1 (p = 0.009), high-grade histology (p = 0.04), CXRT (p = 0.05), CXT (p = 0.0004), CR (p < 0.0001), and RT dose >40 Gy (p = 0.005). For LC, only CR and Stage I were favorable factors. In multivariate analysis, IPI score, RT dose, CR, and CXT were independently influencing the outcome (OS and LSS). CR was the only predicting factor for LC. Conclusion: This large multicenter retrospective study confirms the good prognosis of early-stage PBL treated with combined CXRT. An adequate dose of RT and complete CXT regime were associated with better outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-244: Radiotherapy Risk Estimation Based On Expert Group Survey

Purpose: To evaluate the reliability of RPN (Risk Priority Number) decided by expert group and to provide preliminary data for adapting FMEA in Korea. Methods: 1163 Incidents reported in ROSIS for 11 years were used as a real data to be compared with, and were categorized into 146 items. The questionnaire was composed of the 146 items and respondents had to valuate ‘occurrence (O)’, ‘severity (S)’, ‘detectability (D)’ of each item on a scale from 1 to 10 according to the proposed AAPM TG-100 rating scales. 19 medical physicists from 19 different organizations in Korea had participated in the survey. Because the number of ROSIS items was not evenly spread enough to be classified into 10 grades, 1–5 scale was chosen instead of 1–10 and survey result was also fit to 5 grades to compare. Results: The average O,S,D were 1.77, 3.50, 2.13, respectively and the item which had the highest RPN(32) was ‘patient movement during treatment’ in the survey. When comparing items ranked in the top 10 of each survey(O) and ROSIS database, two items were duplicated and ‘Simulation’ and ’Treatment’ were the most frequently ranked RT process in top 10 of survey and ROSIS each. The Chronbach α of each RT process were ranged from 0.74 to 0.99 and p-value was <0.001. When comparing O*D, the average difference was 1.4. Conclusion: This work indicates the deviation between actual risk and expectation. Considering that the respondents were Korean and ROSIS is mainly composed of incidents happened in European countries and some of the top 10 items of ROSIS cannot be applied in radiotherapy procedure in Korea, the deviation could have been came from procedural difference. Moreover, if expert group was consisted of experts from various parts, expectation might have been more accurate. Therefore, further research on radiotherapy risk estimation is needed.

60 APPLIED LIFE SCIENCES↗

Anomaly Detection in Multiple Scale for Insider Threat Analysis

We propose a method to quantify malicious insider activity with statistical and graph-based analysis aided with semantic scoring rules. Different types of personal activities or interactions are monitored to form a set of directed weighted graphs. The semantic scoring rules assign higher scores for the events more significant and suspicious. Then we build personal activity profiles in the form of score tables. Profiles are created in multiple scales where the low level profiles are aggregated toward more stable higherlevel profiles within the subject or object hierarchy. Further, the profiles are created in different time scales such as day, week, or month. During operation, the insider s current activity profile is compared to the historical profiles to produce an anomaly score. For each subject with a high anomaly score, a subgraph of connected subjects is extracted to look for any related score movement. Finally the subjects are ranked by their anomaly scores to help the analysts focus on high-scored subjects. The threat-ranking component supports the interaction between the User Dashboard and the Insider Threat Knowledge Base portal. The portal includes a repository for historical results, i.e., adjudicated cases containing all of the information first presented to the user and including any additional insights to help the analysts. In this paper we show the framework of the proposed system and the operational algorithms.

99 GENERAL AND MISCELLANEOUS↗

Plaque Brachytherapy for Uveal Melanoma: A Vision Prognostication Model

Purpose: To generate a vision prognostication model after plaque brachytherapy for uveal melanoma. Methods and Materials: All patients with primary single ciliary body or choroidal melanoma treated with iodine-125 or ruthenium-106 plaque brachytherapy between January 1, 2005, and June 30, 2010, were included. The primary endpoint was loss of visual acuity. Only patients with initial visual acuity better than or equal to 20/50 were used to evaluate visual acuity worse than 20/50 at the end of the study, and only patients with initial visual acuity better than or equal to 20/200 were used to evaluate visual acuity worse than 20/200 at the end of the study. Factors analyzed were sex, age, cataracts, diabetes, tumor size (basal dimension and apical height), tumor location, and radiation dose to the tumor apex, fovea, and optic disc. Univariate and multivariable Cox proportional hazards were used to determine the influence of baseline patient factors on vision loss. Kaplan-Meier curves (log rank analysis) were used to estimate freedom from vision loss. Results: Of 189 patients, 92% (174) were alive as of February 1, 2011. At presentation, visual acuity was better than or equal to 20/50 and better than or equal to 20/200 in 108 and 173 patients, respectively. Of these patients, 44.4% (48) had post-treatment visual acuity of worse than 20/50 and 25.4% (44) had post-treatment visual acuity worse than 20/200. By multivariable analysis, increased age (hazard ratio [HR] of 1.01 [1.00-1.03], P=.05), increase in tumor height (HR of 1.35 [1.22-1.48], P<.001), and a greater total dose to the fovea (HR of 1.01 [1.00-1.01], P<.001) were predictive of vision loss. This information was used to develop a nomogram predictive of vision loss. Conclusions: By providing a means to predict vision loss at 3 years after treatment, our vision prognostication model can be an important tool for patient selection and treatment counseling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were able to reliably differentiate between most tissues types regardless of energy level. Dr Godoy has received a dual-energy CT research grant from Siemens Healthcare. That grant did not directly fund this research.

60 APPLIED LIFE SCIENCES↗

Assessing task performance in FFDM, DBT, and synthetic mammography using uniform and anthropomorphic physical phantoms

Purpose The purpose of this study is to quantify the differences in detectability between full field digital mammography (FFDM), digital breast tomosynthesis (DBT), and synthetic mammography (SM) for challenging, low contrast signals, in the context of both a uniform and an anthropomorphic, textured phantom. Methods Images of the phantoms were acquired using a Hologic Selenia Dimensions system. Images were taken at 50%, 100%, and 200% of the dose delivered under automatic exposure control (AEC). Low‐contrast disks, created using an inkjet printer with iodine‐doped ink, were inserted into the phantom. The disks varied in diameter from 210 to 630 μ m, and in local contrast from 1.1% to 2.8% in regular increments. Human observers located the disks in a 4 alternative forced choice experiment. Proportion correct (PC) was computed as the number of correct localizations out of the total number of tries. Results Overall, scores from FFDM and DBT were consistently greater than scores from SM. At an exposure corresponding to the AEC setting, mean PC scores for the largest disks with the uniform phantom were 0.80 for FFDM, 0.83 for DBT, and 0.66 for SM, with the same rank ordering at other doses. Scores were similar but lower for the nonuniform background. At an exposure twice the AEC setting, however, the difference between uniform and nonuniform scores was most pronounced for DBT alone. Differences between scores for FFDM and SM were statistically significant, while those between FFDM and DBT were not. Scores were used to compute the minimum contrast level needed to reach 62.5% detection rate. The minimum contrast for SM was 36%–81% higher compared to FFDM or DBT, in either background. Conclusions This study shows that an anthropomorphic phantom and lesions inserts may be used to conduct a reader study. Detectability was significantly lower for synthetic mammography than for FFDM or DBT, for all conditions. Additionally, observer performance was consistently lower for the anthropomorphic phantom, indicating the greater challenge due to anatomical background. Because of this, it may be important to use realistic phantoms in observer studies in order to draw conclusions that are more clinically relevant.

Ikejimba, Lynda C.↗

A Passive Method for Detecting Vegetation Stress from Orbit: Chlorophyll Fluorescence Spectra from Fraunhofer Lines

Solar-stimulated chlorophyll fluorescence measured with the Fraunhofer line depth method has correlated well with vegetation stress in previous studies. However, the instruments used in those studies were limited to a single solar absorption line (e.g. 656.3 nm), obviating the red/far-red ratio (R/FR) method. Optics and detector technology have reached the level whereby multiple, very narrow Fraunhofer lines are resolvable. Thirteen such lines span the visible spectrum in the red to far-red region where chlorophyll fluorescence occurs. Fluorescence intensities at the 13 Fraunhofer line wavelengths were used to model emission spectra. The source data were collected for summer and fall bean crops (Phaseolus vulgaris L.) subjected to various levels of nitrogen fertilization. The intensities were adjusted to account for Fraunhofer line depth and atmospheric transmittance. Multiple R/FR fluorescence ratios, calculated from the modeled fluorescence spectra, correlated strongly with leaf chlorophyll concentration and well with applied nitrogen. The ratio yielding the best correlation with chlorophyll utilized red fluorescence at the 694.5 nm Fraunhofer line and farred fluorescence at the 755.6 nm Fraunhofer line. Twenty R/FR ratios, each evaluated for the maximum differential between low and high (optimal) nitrogen treatments, ranked higher in some cases and lower in others, possibly related to the time of year the crops were grown and the stage of growth of the crops. Ratios with 728.9 nm and 738.9 nm in the denominator consistently ranked in the lowest and next lowest quartile, respectively. Ratios of the 656.3 nm Fraunhofer line and the 755.6 nm line consistently ranked highest for the summer crop. Ratios with 755.6 nm in the denominator ranked in the upper quartile for 10 out of 12 measurement dates. Differences in ratio ranking indicate that physiological conditions may be estimated using selected ratios of Fraunhofer lines within the context of R/FR analysis. A passive instrument designed to monitor R/FR chlorophyll fluorescence (i.e. vegetation stress) from orbit could be built today.

Theisen, Arnold F.↗

Assessment of lignite upgrade and hydrogen evolution via electrolysis

Lignite, considered as the lowest-rank coal, accounts for 45% of the total coal resources worldwide, and its low carbon and high ash contents limit its large-scale application. In order to upgrade lignite effectively, a modified coal electrolytic cell (MCEC) was designed, built, and then evaluated for lignite upgrade and hydrogen production through electrolysis, and the operating conditions were optimized. The results show that the performance of the MCEC outperformed the previous coal electrolytic cell (CEC). The operating temperature and iron concentration significantly impact the average current density per milligram of catalyst (ACDMC). The content of dry fixed carbon and heating value increased by 20.9% (wt%) and 8.15%, respectively, in electrolyzed lignite compared with raw lignite. Besides, 71.5% ash and 39.6% mercury were removed from raw lignite after electrolysis, which is the first report. The Faradaic efficiency (FE) for hydrogen evolution reached 99% using MCEC. In addition, the analysis of spectroscopy methods (SEM, EDX, FTIR, and XRD) revealed that the lignite particles were cracked; the oxygen-containing functional groups increased; the minerals of quartz and hematite formed on the surface of lignite particles after electrolysis. Furthermore, the facts indicate that electrolysis of lignite is a competitive approach for lignite upgrade and hydrogen production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrity of the National Resident Matching Program for Radiation Oncology: National Survey of Applicant Experiences

Purpose: The aim of this study was to examine the experiences of radiation oncology applicants and to evaluate the prevalence of behaviors that may be in conflict with established ethical standards. Methods and Materials: An anonymous survey was sent to all 2013 applicants to a single domestic radiation oncology residency program through the National Resident Matching Program (NRMP). Questions included demographics, survey of observed behaviors, and opinions regarding the interview and matching process. Descriptive statistics were presented. Characteristics and experiences of respondents who matched were compared with those who did not match. Results: Questionnaires were returned by 87 of 171 applicants for a 51% response rate. Eighty-two questionnaires were complete and included for analysis. Seventy-eight respondents (95.1%) reported being asked at least 1 question in conflict with the NRMP code of conduct. When asked where else they were interviewing, 64% stated that this query made them uncomfortable. Forty-five respondents (54.9%) reported unsolicited post-interview contact by programs, and 31 (37.8%) felt pressured to give assurances. Fifteen respondents (18.3%) reported being told their rank position or that they were “ranked to match” prior to Match day, with 27% of those individuals indicating this information influenced how they ranked programs. Half of respondents felt applicants often made dishonest or misleading assurances, one-third reported that they believed their desired match outcome could be improved by deliberately misleading programs, and more than two-thirds felt their rank position could be improved by having faculty from their home institutions directly contact programs on their behalf. Conclusions: Radiation oncology applicants report a high prevalence of behaviors in conflict with written NRMP policies. Post-interview communication should be discouraged in order to enhance fairness and support the professional development of future radiation oncologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A physics-informed and hierarchically regularized data-driven model for predicting fluid flow through porous media

This paper presents a new deep learning data-driven model for predicting structure dependent pore-fluid velocity fields in rock. The model is based on a Convolutional Auto-Encoder (CAE) artificial neural network capable of learning from image data generated by direct numerical simulations of fluid flow through pore-structures, such as by Lattice Boltzmann or molecular dynamics methods. The main novelty of the model in comparison to previous CAE-based data-driven approaches consists of three parts. The first is a methodology for decomposing the full-domain of the porous media into sub-regions, or “sub-domains”, in order to reduce the overall size of the CAE, batch process the sub-domains in parallel, and enable the CAE to learn local and generalizable nonlinear mappings of pore-fluid velocities. The second consists of embedding the finite difference solutions of the incompressible Navier-Stokes and continuity equations into convolutional layers prior to the CAE in order to provide the CAE with knowledge of fluid dynamics physics (PhyFlow). The third main novelty is that the training of the CAE is regularized with a hierarchical loss function that encourages the learning of fluid flow patterns (in a way similar to ranked modes in principal component analysis), ranking from most to least important. This is shown to increase the stability in learning, reduce over-fitting, and promote interpretability of the CAE neural network layers (HierCAE). The comprehensive new data-driven model, which we call the PhyFlow-HierCAE model, is shown to exhibit improved accuracy and generalizability of flow field predictions over conventional CAE models, attributable to the embedded physical knowledge and the hierarchical regularization, as well as realize orders of magnitude speed-ups in computation times as a surrogate for the direct numerical simulations. Examples of training and forward predictions on unseen pore-structures are provided and evaluated for data from Lattice Boltzmann and molecular dynamics simulations of pore-fluid flow. The model is shown to be a fast and accurate emulator (or “surrogate”) for predicting effective permeability of unseen pore-structures based on learning from relatively small direct numerical simulation datasets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-C-17A-06: Evaluating IMRT Plan Deliverability Via PTV Shape and MLC Motion

Purpose: For step-and-shoot intensity-modulated radiation therapy (IMRT) plans, the dosimetry and deliverability can be affected by the number and shape of the segments used. Thus, plan deliverability is likely related to target volume and shape. We investigated whether the sphericity of target volumes and the previously proposed Modulation Complexity Score (MCS) could be used together to improve the detection of IMRT fields that failed quality assurance (QA). Methods: 526 and 353 IMRT fields from 32 prostate and 28 head-and-neck (H'N) patients, respectively, were analyzed. MCS was used to quantify the complexity of multi-leaf collimator shapes and motion patterns for each field. Sphericity was calculated using the surface area and volume of each patient’s planning target volume (PTV). Logistic regression models with MCS-alone or MCS and sphericity terms were fit to PlanUNC IMRT pass/fail results (5% dose difference, 4mm distance-to-agreement criteria) using SAS 9.3 (Cary, NC). Model concordance, discordance and area under the curve (AUC) were used to quantify model accuracy. Results: Mean (±1 standard deviation) MCS for prostate and H'N were 0.58(±0.15) and 0.40 (±0.14), respectively. Mean sphericity scores were 0.75(±0.05) for prostate and 0.63 (±0.12) for H'N. Both metrics were significantly different between treatment locations (p<0.01, Wilcoxon Rank Sum Test) indicating greater complexity in shape and variations for H'N PTVs. For prostate, concordance, discordance and AUC using MCS alone were 80.8%, 18.7% and 0.811. Including sphericity in the model improved these to 81.7%, 17.7% and 0.820. For H'N, the original concordance, discordance and AUC were of 72.9%, 26.9% and 0.729. Including sphericity into the model improved these metrics to 76.5%, 23.2% and 0.729. Conclusion: Sphericity provides a quantitative measure of PTV shape. While improvement in IMRT QA failure detection was modest for both prostate and H'N plans, including sphericity in the model does improve IMRT field failure prediction.

60 APPLIED LIFE SCIENCES↗

Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry

Purpose: To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. Methods: Twenty volumetric images of patient breasts were acquired with a dedicated breast CT prototype system and the voxels in the breast CT images were automatically classified into skin, adipose, and glandular tissue. The breasts in the classified images underwent simulated mechanical compression to mimic the conditions present during mammographic acquisition. The compressed thickness for each breast was set to that achieved during each patient's last screening cranio-caudal (CC) acquisition. The volumetric glandular density of each breast was computed using both the compressed and uncompressed classified images, and additional images were created in which all voxels representing adipose and glandular tissue were replaced by a homogeneous mixture of these two tissues in a proportion corresponding to each breast's volumetric glandular density. All four breast images (compressed and uncompressed; heterogeneous and homogeneous tissue) were input into Monte Carlo simulations to estimate the normalized glandular dose during mammography (compressed breasts) and dedicated breast CT (uncompressed breasts). For the mammography simulations the x-ray spectra used was that used during each patient's last screening CC acquisition. For the breast CT simulations, two x-ray spectra were used, corresponding to the x-ray spectra with the lowest and highest energies currently being used in dedicated breast CT prototype systems under clinical investigation. The resulting normalized glandular dose for the heterogeneous and homogeneous versions of each breast for each modality was compared. Results: For mammography, the normalized glandular dose based on the homogeneous tissue approximation was, on average, 27% higher than that estimated using the true heterogeneous glandular tissue distribution (Wilcoxon Signed Rank Test p= 0.00046). For dedicated breast CT, the overestimation of normalized glandular dose was, on average, 8% (49 kVp spectrum, p= 0.00045) and 4% (80 kVp spectrum, p= 0.000089). Only two cases in mammography and two cases in dedicated breast CT with a tube voltage of 49 kVp resulted in lower dose estimates for the homogeneous tissue approximation compared to the heterogeneous tissue distribution. Conclusions: The normalized glandular dose based on the homogeneous tissue mixture approximation results in a significant overestimation of dose to the imaged breast. This overestimation impacts the use of dose estimates in absolute terms, such as for risk estimates, and may impact some comparative studies, such as when modalities or techniques with different x-ray energies are used. The error introduced by the homogeneous tissue mixture approximation in higher energy x-ray modalities, such as dedicated breast CT, although statistically significant, may not be of clinical concern. Further work is required to better characterize this overestimation and potentially develop new metrics or correction factors to better estimate the true glandular dose to breasts undergoing imaging with ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Synthetic accessibility and stability rules of NASICONs

In this paper we develop the stability rules for NASICON-structured materials, as an example of compounds with complex bond topology and composition. By first-principles high-throughput computation of 3881 potential NASICON phases, we have developed guiding stability rules of NASICON and validated the ab initio predictive capability through the synthesis of six attempted materials, five of which were successful. A simple two-dimensional descriptor for predicting NASICON stability was extracted with sure independence screening and machine learned ranking, which classifies NASICON phases in terms of their synthetic accessibility. This machine-learned tolerance factor is based on the Na content, elemental radii and electronegativities, and the Madelung energy and can offer reasonable accuracy for separating stable and unstable NASICONs. This work will not only provide tools to understand the synthetic accessibility of NASICON-type materials, but also demonstrates an efficient paradigm for discovering new materials with complicated composition and atomic structure.

25 ENERGY STORAGE↗

Collaborative Research: Atlantic Ocean Tropical/Subtropical Processes from Seasonal to Decadal Time Scales: Model/Data, Model/Model Comparison and Model/Data Synthesis Through Assimilation

The effort of this first year of research has been focused on the assimilation of TOPEX/Poseidon altimetric data into a primitive equation model of the Atlantic tropical/subtropical circulation. A reduced-rank, stationary Kalman filter has been constructed to assimilate the altimetric sea surface height anomaly (SHA) into the model. The goal is to assess how the inter-hemispheric transports between the Atlantic subtropics and tropics are affected by the assimilation and how the subsurface thermocline structure , and its variability ,is dynamically constrained by the SHA. The model is a reduced-gravity primitive equation GCM of the upper Atlantic Ocean between 30 S and 30 N. The assimilation scheme is an approximation to the extended Kalman filter in which the error covariances of the state estimates are calculated only in a reduced- dimension subspace. The subspace is defined by the leading empirical orthogonal functions calculated from an unconstrained model calculation. Both an identical twin experiment using simulated SHA observations and assimilation of the real TOPEX data were performed. Results from the twin experiments demonstrate the ability of the method to constrain the ocean circulation and the subsurface temperature structure. The impact on the subsurface temperature structure of TOPEX assimilation was assessed using data from expandable bathythermographs. This showed a substantial improvement in the estimated temperature variability only within 13 degrees in latitude around the equator. The impact of TOPEX SHA assimilation on zonally integrated meridional transport across different latitudes was also estimated. Again within 13 degrees from the equator both the mean amplitude and interannual variability of the surface and subsurface transports were significantly enhanced, while the transports were insensitive to the assimilation in the subtropics.

Malannotte-Rizzoli, Paola↗