Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

A LENA Instrument onboard BepiColombo and Chandrayaan-1

Low-energy neutral atom (LENA) observations bring us important information on particle environments around planetary objects such as Mercury and the Moon. In this paper, we report on a new development of a LENA instrument of light weight ({approx}2 kg) for planetary explorations. The instrument is capable of energy and mass discrimination with a large sensitivity by utilizing surface ionization followed by an electrostatic analyzer and a time-of-flight velocity spectrometer. The performance of the instrument is investigated by numerical simulations. This enables us to obtain detailed performance characterization of LENA measurements by the instrument. We also made trajectory tracing of photons entering the instrument to examine photon rejection capability. The simulations show that the energy range is from {approx}10 eV to >3.3 keV and the angular resolutions are 10 degx25 deg for 25-eV LENAs, which are sufficient for planetary LENA observations. Laboratory tests of a prototype model of the instruments developed with this study are now ongoing. According to the initial tests, the measurement principle of the instrument has been verified. This LENA instrument has been selected for both the Indian Moon exploration mission Chandrayaan-1 and the European-Japanese Mercury exploration mission BepiColombo.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high efficiency veto to increase the sensitivity of ZEPLIN-III, a WIMP detector

An active veto detector to complement the ZEPLIN-III two phase Xenon, direct dark matter device is described. The proposed design consists of 52 plastic scintillator segments, individually read out by high efficiency photomultipliers, coupled to a Gd loaded passive polypropylene shield. Experimental work was performed to determine the plastic scintillator characteristics which were used to inform a complete end-to-end Monte Carlo simulation of the expected performance of the new instrument, both operating alone and as an active veto detector for ZEPLIN-III. The veto device will be capable of tagging over 65% of coincident nuclear recoil events in the energy range of interest in ZEPLIN-III, and over 12% for gamma ray rejection, while contributing no significant additional background. In addition it will also provide valuable diagnostic capabilities. The inclusion of the veto to ZEPLIN-III will aid to significantly improve the sensitivity to spin independent WIMP-nucleon cross sections below 10{sup -8} pb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HPGS - A Sensitive Dark Matter Detector Using High Pressure Xe Gas at Room Temperature

We propose a dark matter detector based on scintillation in Xe gas at 5-10 bar pressure. Scintillation pulses are a factor 10 longer for alpha pulses than gamma pulses, and measurements in progress using neutron scattering indicate that the same difference applies to nuclear recoils, giving a 1E-6 rejection factor for electron recoil background. Light collection and background calculations indicate that dark matter sensitivity levels 1e-9 pb to 1E-10 pb would be achievable. Room temperature operation would enable Xe gas experiments >1 ton to be built at lower cost than current designs using liquid noble gases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters

The employment of large arrays of microcalorimeters in space missions (IXO, EDGE/XENIA), requires the presence of an anticoincidence detector to remove the background due to the particles, with a rejection efficiency at least equal to Suzaku (98%). A new concept of anticoincidence is under development to match the very tight thermal requirements and to simplify the design of the electronic chain. The idea is to produce a Cryo-AntiCoincidence (Cryo-AC) based on a silicon absorber and read by a TES (Transition-Edge Sensor). This configuration would ensure very good performances in terms of efficiency, time response and signal to noise ratio. We present the results of estimations, simulations and preliminary measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DEAP/CLEAN Dark Matter Search

The DEAP/CLEAN collaboration is constructing the latest generation of a series of single-phase noble-liquid dark matter experiments. The MiniCLEAN detector is expected to obtain a sensitivity to the spin-independent WIMP-nucleon cross-section in the neighborhood of 10{sup -45}cm{sup 2} for M{sub WIMP}{approx_equal}100GeV. The detector will have the ability to utilize LAr or LNe as a target, which in the event of a positive signal will allow the expected A{sup 2} dependence in cross section to be probed, as well as produce very different intrinsic background characteristics.In addition to the status of the MiniCLEAN detector, data from DEAP-1, a 7 kg liquid argon detector currently running at SNOLAB, is presented here, including its demonstrated background rejection power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of tau leptons and prospects for SUSY in ATLAS

Final states with tau leptons may play a special role among the broad variety of signatures for the production of supersymmetric particles at the LHC. The algorithms for tau reconstruction and identification are discussed, which are essential ingredients to reject the huge background from QCD processes. The status of analyses of SUSY tau lepton final states within the ATLAS experiment at the LHC are presented, which range from a study of semi-inclusive discovery prospects to more exclusive processes with two tau leptons from chi-tilde{sub 2}{sup 0} decays and their implications for the determination of SUSY parameters. Also, the prospects for exploiting tau lepton polarization are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon Reconstruction and Identification with the ATLAS detector

The understanding of the photons reconstruction will be one of the key issues at the start-up of data-taking with the ATLAS experiment at the LHC. Large statistics samples of photons produced in association with jets are expected over a wide range of E{sub T}.The photon reconstruction is based on an electromagnetic-cluster-seeded algorithm which classifies as photons those clusters which have no matching prompt track. These are then subdivided into converted or non-converted photon candidates depending on the presence of one or more tracker-reconstructed electron-positron pairs pointing to it. The precise knowledge of the material upstream the calorimeter and a correct treatment of the converted photons are critical for a correct photon reconstruction and identification.The photon identification is based almost entirely on the analysis of the shower shapes in the calorimeter. The goal is to achieve an efficient photon selection in the range from 20 GeV to several hundreds GeV with a rejection of 10{sup 3}-10{sup 4} against QCD jets in the moderate transverse momentum region of 20 to 100 GeV, which is the relevant one for H->gammagamma searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EDELWEISS-II : status and first results

The EDELWEISS-II experiment is devoted to the direct detection of WIMP dark matter, using a new generation of cryogenic germanium detectors. We will present preliminary results of the first operation of these detectors installed in the Modane underground laboratory. Very low radioactive background conditions are achieved. Furthermore, these new detectors, with a special electrode design for active rejection of surface events, have been experimentally shown to be suited for WIMP searches with spin-independent scattering cross-sections on a nucleon well below 10{sup -8} pb. Preliminary results of WIMP searches performed with a first set of these detectors will be shown as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hunting the Dark Matter with DEAP/CLEAN

The potential of the DEAP/CLEAN program for direct Dark Matter detection to test various dark matter models is illustrated. The scintillation pulse of a noble liquid like Argon or Neon has two well distinguished time constants allowing a very reliable correlation between pulse shape and type of event. This pulse shape discrimination already provides the power of rejecting a background10{sup 8}-10{sup 9} times larger than the signal. MiniCLEAN, a 500 kg LAr detector, is currently under construction, and a 3.6 ton detector, DEAP-3600, under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ArgoNeuT and MicroBooNE: LAr-TPC's at Fermilab

Liquid Argon Time Projection Chamber technology provides unique features in event imaging and calorimetric resolution. These characteristics, combined with a good rejection power and a (virtually) unlimited active mass, make this detector one of the best candidate for the next generation of long-baseline neutrino oscillation experiments aimed at precision measurements of the MNPS matrix elements. Up to now the largest LAr-TPC operated is the first semi-module of the ICARUS T600 detector (300 tons of LAr). The scalability of this technology to massive detectors (>=5 ktons) is still to be proven. The ArgoNeuT detector, a small LAr-TPC (0.24 ton of active mass) exposed to the NuMI beam at FNAL currently producing the first low-energy neutrino events in a LAr-TPC, is the first step of a staged US program to realize and operate a massive LAr-TPC detector. The proposed MicroBooNE experiment, a LAr-TPC of 100 tons of active mass, to be exposed to the Booster Neutrino Beam and the NuMI beam at FNAL, is the next crucial step of this program. Design details and experimental goals of both experiments are reported in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Low Energy Neutrino Factory

We show that a low energy neutrino factory with a baseline of 1300 km and muon energy of 4.5 GeV has an excellent physics reach. The results of our optimisation studies demonstrate that such a setup can have remarkable sensitivity to theta{sub 13} and delta for sin{sup 2}(2theta{sub 13})>10{sup -4}, and to the mass hierarchy for sin{sup 2}(2theta{sub 13})>10{sup -3}. We also illustrate the power of the unique combination of golden and platinum channels accessible to the low energy neutrino factory. We have considered both a 20 kton totally active scintillating detector and a 100 kton liquid argon detector as possible detector technologies, finding that a liquid argon detector with very good background rejection can produce sensitivity to theta{sub 13} and delta with that of the International Design Study neutrino factory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Double Beta Decay of {sup 48}Ca by CANDLES

CANDLES is the project to search for neutrino-less double beta decay (0nubetabeta) of {sup 48}Ca. The observation of 0nubetabeta will prove existence of a massive Majorana neutrino. We have developed the new detector system CANDLES which features CaF{sub 2}(pure) scintillators. Here expected performances of the system for background rejection are presented. It is also described current status of development for the detector system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Edelweiss-II Dark Matter Search : Status and first results

EDELWEISS is a direct dark matter search experiment operating in the low radioactivity environment of the Modane Underground Laboratory. The experiment runs at very low temperature massive Ge detectors in order to identify nuclear recoils induced by elastic scattering of WIMPs from the galactic halo. The commissioning of the second phase of the experiment, involving more than 7 kg of Ge detector, has been completed in 2007. These ionization/heat detectors allow an event by event electronic/nuclear recoil discrimination. Preliminary results of a new type of bolometer with interdigitized electrodes for the charge collection with active rejection are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

TEMPO: a New Insertion Device Beamline at SOLEIL for Time Resolved Photoelectron Spectroscopy Experiments on Solids and Interfaces

A new insertion device beamline is now operational on straight section 8 at the SOLEIL synchrotron radiation source in France. The beamline and the experimental station were developed to optimize the study of the dynamics of electronic and magnetic properties of materials. Here we present the main technical characteristics of the installation and the general principles behind them. The source is composed of two APPLE II type insertion devices. The monochromator with plane gratings and spherical mirrors is working in the energy range 40-1500 eV. It is equipped with VLS, VGD gratings to allow the user optimization of flux or higher harmonics rejection. The observed resonance structures measured in gas phase enable us to determine the available energy resolution: a resolving power higher than 10000 is obtained at the Ar 2p, N 1s and Ne K-edges when using all the optical elements at full aperture. The total flux as a function of the measured photon energy and the characterization of the focal spot size complete the beamline characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Broadband notch filter design for millimeter-wave plasma diagnostics

Notch filters are integrated in plasma diagnostic systems to protect millimeter-wave receivers from intensive stray radiation. Here we present a design of a notch filter with a center frequency of 140 GHz, a rejection bandwidth of {approx}900 MHz, and a typical insertion loss below 2 dB in the passband of {+-}9 GHz. The design is based on a fundamental rectangular waveguide with eight cylindrical cavities coupled by T-junction apertures formed as thin slits. Parameters that affect the notch performance such as physical lengths and conductor materials are discussed. The excited resonance mode in the cylindrical cavities is the fundamental TE{sub 11}. The performance of the constructed filter is measured using a vector network analyzer monitoring a total bandwidth of 30 GHz. We compare the measurements with numerical simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital method for separation and reconstruction of pile-up events in germanium detectors

The problem of pulse pile-up is very often encountered in precise measurements of {gamma}-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather than simply tolerating the losses associated with pile-up. In this paper, a method for the off-line digital processing of pile-up events from germanium detectors is demonstrated. The method is based on an appropriate fitting of the detector signals, shaped with a suitable digital pulse shaper. It is shown that the method is able to recover the pile-up events with good accuracy even when the constituent signals are in close proximity. The method is very useful for {gamma}-ray spectroscopy in nuclear physics experiments, where the low intensity signals can be lost due to the pile-up in a high-rate environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time reflectometry measurement validation in H-mode regimes for plasma position control

It has been shown that in H-mode regimes, reflectometry electron density profiles and an estimate for the density at the separatrix can be jointly used to track the separatrix within the precision required for plasma position control on ITER. We present a method to automatically remove, from the position estimation procedure, measurements performed during collapse and recovery phases of edge localized modes (ELMs). Based on the rejection mechanism, the method also produces an estimate confidence value to be fed to the position feedback controller. Preliminary results show that the method improves the real-time experimental separatrix tracking capabilities and has the potential to eliminate the need for an external online source of ELM event signaling during control feedback operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep-ultraviolet photodetectors from epitaxially grown Ni{sub x}Mg{sub 1-x}O

Deep-ultraviolet (DUV) photodetectors were fabricated from high quality Ni{sub x}Mg{sub 1-x}O epitaxially grown by plasma-assisted molecular beam epitaxy on an approximately lattice matched MgO <100> substrate. A mid-range Ni composition (x=0.54) Ni{sub x}Mg{sub 1-x}O film was grown for DUV ({lambda}{sub peak}<300 nm) photoresponse and the film was characterized by reflected high-energy electron diffraction, Rutherford backscattering spectroscopy, x-ray diffraction, and optical transmission measurements. Photoconductive detectors were then fabricated by deposition of symmetric interdigitated contacts (10 nm Pt/150 nm Au) with contact separations of 5, 10, and 15 {mu}m. The detectors exhibited peak responsivities in the DUV ({lambda}{sub peak{approx_equal}}250 nm) as high as 12 mA/W, low dark currents (I{sub dark}<25 nA), and DUV:visible rejection ratio of approximately 800:1.

36 MATERIALS SCIENCE↗