Search NASA⌕ Search

SEARCH · Search NASA

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Establishment of a Background Environmental Monitoring Station for the PNNL Campus

The environmental surveillance of background levels of radionuclides and, in particular, the siting of a background environmental surveillance (monitoring) station are examined. Many published works identify and stress the need for background monitoring; however, little definitive and comprehensive information for siting a station exists. A definition of an ideal background monitoring location and the generic criteria recommended for use in establishing such a background monitoring location are proposed. There are seven primary (mandatory) criteria described with two additional, optional criteria. The criteria are applied to the Richland, Washington (WA), Pacific Northwest National Laboratory (PNNL) Campus, which currently uses background monitoring data from the nearby Hanford Site. Eleven potential background monitoring sites were identified, with one location in Benton City, WA found to meet all of the mandatory and optional criteria. It is expected that the new sampler will be installed and operating by the end of June, 2015.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Water Reactor Sustainability Program: Analysis of Pressurized Water Reactor Station Blackout Caused by External Flooding Using the RISMC Toolkit

The existing fleet of nuclear power plants is in the process of extending its lifetime and increasing the power generated from these plants via power uprates. In order to evaluate the impact of these factors on the safety of the plant, the Risk Informed Safety Margin Characterization (RISMC) project aims to provide insight to decision makers through a series of simulations of the plant dynamics for different initial conditions (e.g., probabilistic analysis and uncertainty quantification). This report focuses, in particular, on the application of a RISMC detailed demonstration case study for an emergent issue using the RAVEN and RELAP-7 tools. This case study looks at the impact of a couple of challenges to a hypothetical pressurized water reactor, including: (1) a power uprate, (2) a potential loss of off-site power followed by the possible loss of all diesel generators (i.e., a station black-out event), (3) and earthquake induces station-blackout, and (4) a potential earthquake induced tsunami flood. The analysis is performed by using a set of codes: a thermal-hydraulic code (RELAP-7), a flooding simulation tool (NEUTRINO) and a stochastic analysis tool (RAVEN) – these are currently under development at the Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fire Protection Engineering Design Brief Template: Hydrogen Refueling Station

Building a hydrogen infrastructure system is critical to supporting the development of alternate- fuel vehicles. This report provides a methodology for implementing a performance-based design of an outdoor hydrogen refueling station that does not meet specific prescriptive requirements in NFPA 2, The Hydrogen Technologies Code . Performance-based designs are a code-compliant alternative to meeting prescriptive requirements. Compliance is demonstrated by comparing a prescriptive-based fueling station design with a performance-based design approach using Quantitative Risk Assessment (QRA) methods and hydrogen risk assessment tools. This template utilizes the Sandia-developed QRA tool, Hydrogen Risk Analysis Models (HyRAM), which combines reduced-order deterministic models that characterize hydrogen release and flame behavior with probabilistic risk models to quantify risk values. Each project is unique and this template is not intended to account for site-specific characteristics. Instead, example content and a methodology are provided for a representative hydrogen refueling site which can be built upon for new hydrogen applications.

08 HYDROGEN↗

Retrieving 4-dimensional atmospheric boundary layer structure from surface observations and profiles over a single station

Most routine measurements from climate study facilities, such as the Department of Energy’s ARM SGP site, come from individual sites over a long period of time. While single-station data are very useful for many studies, it is challenging to obtain 3-dimensional spatial structures of atmospheric boundary layers that include prominent signatures of deep convection from these data. The principal objective of this project is to create realistic estimates of high-resolution (~ 1km × 1km horizontal grids) atmospheric boundary layer structure and the characteristics of precipitating convection. These characteristics include updraft and downdraft cumulus mass fluxes and cold pool properties over a region the size of a GCM grid column from analyses that assimilate surface mesonet observations of wind, temperature, and water vapor mixing ratio and available profiling data from single or multiple surface stations. The ultimate goal of the project is to enhance our understanding of the properties of mesoscale convective systems and also to improve their representation in analysis and numerical simulations. During the proposed period (09/15/2011–09/14/2014) and the no-cost extension period (09/15/2014–09/14/2015), significant accomplishments have been achieved relating to the stated goals. Efforts have been extended to various research and applications. Results have been published in professional journals and presented in related science team meetings and conferences. These are summarized in the report.

54 ENVIRONMENTAL SCIENCES↗

Geoscience Australia Continuous Global Positioning System (CGPS) Station Field Campaign Report

This station formed part of the Australian Regional GPS Network (ARGN) and South Pacific Regional GPS Network (SPRGN), which is a network of continuous GPS stations operating within Australia and its Territories (including Antarctica) and the Pacific. These networks support a number of different science applications including maintenance of the Geospatial Reference Frame, both national and international, continental and tectonic plate motions, sea level rise, and global warming.

58 GEOSCIENCES↗

Evaluation of Maximum Radionuclide Groundwater Concentrations for Basement Fill Model. Zion Station Restoration Project

ZionSolutions is in the process of decommissioning the Zion Nuclear Power Station (ZNPS). After decommissioning is completed, the site will contain two reactor Containment Buildings, the Fuel Handling Building and Transfer Canals, Auxiliary Building, Turbine Building, Crib House/Forebay, and a Waste Water Treatment Facility that have been demolished to a depth of 3 feet below grade. Additional below ground structures remaining will include the Main Steam Tunnels and large diameter intake and discharge pipes. These additional structures are not included in the modeling described in this report, but the inventory remaining (expected to be very low) will be included with one of the structures that are modeled as designated in the Zion Station Restoration Project (ZSRP) License Termination Plan (LTP). The remaining underground structures will be backfilled with clean material. The final selection of fill material has not been made.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hot Cell Installation and Demonstration of the Severe Accident Test Station

A Severe Accident Test Station (SATS) capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident (DBA) and beyond design basis accident (BDBA) scenarios has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory (IFEL), a hot cell facility at Oak Ridge National Laboratory. The two test station modules provide various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident (LOCA) testing, defueled oxidation quench testing and high temperature BDBA testing. The installation of the SATS system restores the domestic capability to examine postulated and extended LOCA conditions on spent fuel and cladding and provides a platform for evaluation of advanced fuel and accident tolerant fuel (ATF) cladding concepts. This document reports on the successful in-cell demonstration testing of unirradiated Zircaloy-4. It also contains descriptions of the integral test facility capabilities, installation activities, and out-of-cell benchmark testing to calibrate and optimize the system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spallation Neutron Source Second Target Station Integrated Systems Update

The Spallation Neutron Source (SNS) was designed from the beginning to accommodate both an accelerator upgrade to increase the proton power and a second target station (STS). Four workshops were organized in 2013 and 2014 to identify key science areas and challenges where neutrons will play a vital role [1-4]. Participants concluded that the addition of STS to the existing ORNL neutron sources was needed to complement the strengths of High Flux Isotope Reactor (HFIR) and the SNS first target station (FTS). To address the capability gaps identified in the workshops, a study was undertaken to identify instrument concepts that could provide the required new science capabilities. The study outlined 22 instrument concepts and presented an initial science case for STS [5]. These instrument concepts formed the basis of a planning suite of instruments whose requirements determined an initial site layout and moderator selection. An STS Technical Design Report (TDR) documented the STS concept based on those choices [6]. Since issue of the TDR, the STS concept has significantly matured as described in this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refueling Station, Ethanol, Operation

This unit process includes the emissions from the operation of a refueling station for an ethanol and gasoline blended fuel. Electricity demand and emissions from fuel evaporation during station filling and vehicle filling are also included. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=1983FDBF-2320-46C2-A043-BF8A14B120B1

09 BIOMASS FUELS↗

Thermal Modeling of a Loaded Magnastor Storage System at Catawba Nuclear Station

This report represents fulfillment of the M2 Milestone M2FT-16PN080203031, “High Heat Load Thermal Analyses,” under Work Package FT-16PN08020303. The report documents the analysis of the NAC International, Inc. (NAC) Modular, Advanced Generation, Nuclear All-purpose STORage (MAGNASTOR) module at Duke’s Catawba Nuclear Station. As part of the Used Fuel Disposition Campaign of the U.S. Department of Energy, a high-burnup fuel storage demonstration is planned for a storage module in the North Anna Nuclear Station’s Independent Spent Fuel Storage Installation (ISFSI). The storage module selected for this demonstration is an AREVA TN-32B High Burnup cask. The main goals of this proposed test are to provide confirmatory data for model validation and potential improvement, support license renewals and new licenses for ISFSIs, and support transportation licensing for high burnup spent nuclear fuel (EPRI 2014). The focus of the Demonstration test is the performance of the high-burnup fuel. To support the High Burnup Spent Fuel Data Project, Pacific Northwest National Laboratory (PNNL) staff performed a detailed thermal analysis (Fort et al. 2016) of the TN-32B cask. It was found that when conservatisms were removed from the thermal models and especially from the calculated decay heats, the predicted peak cladding temperatures (PCTs) were significantly below the 400°C (752°F) regulatory guidance limit, as specified in Interim Staff Guidance 11, Revision 3, (U.S. NRC 2003).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

1st MPEX Users Research Forum (MURF) summary report: specifications for the Surface Analysis Station (SAS)

The Material Plasma Exposure eXperiment (MPEX) Team has reached out to the community of potential users of the MPEX facility to assess the high-priority capabilities which should be considered for inclusion in the design of the MPEX Surface Analysis Station (SAS). This activity is being carried out during the “advanced conceptual design” period of MPEX, i.e. post Conceptual Design Review (CDR) but prior to Preliminary Design (PD), to respond to a recommendation by the U.S. D.O.E. following the CDR. The MPEX Team will summarize the community recommendations into a guidance document (i.e. this report), which will influence the Surface Analysis Station during the Preliminary Design phase of the project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial Engineering Design of a Post-Combustion CO 2 Capture (PCC) System for Duke Energy’s East Bend Station Using Membrane-Based Technology

The Electric Power Research Institute (EPRI) led a U.S. Department of Energy (DOE) funded study for a membrane-based post-combustion CO 2 capture (PCC) system retrofit to an existing U.S. coal power plant. EPRI teamed with technology suppliers, Membrane Technology and Research (MTR), engineering consultants Nexant, Trimeric Corporation and Bechtel Power Corporation, to develop a first-of-a-kind initial design and cost estimate for a PCC system at Duke Energy’s East Bend Station (EBS) in Kentucky. This project provides a comprehensive overview of the plant design proposed and develops estimated costs to within +/- 30% accuracy for retrofitting the existing EBS coal-fired power plant with the latest MTR’s second-generation Polaris™ membrane technology for CO 2 flue gas removal. The projects primary objective was to develop a design for Duke Energy that will require “minimally invasive surgery” on their existing 600-MWe coal-fired power plant, located on the Ohio River in Boone County, Kentucky. Unlike the current commercially available solvent-based capture systems that require a reliable source of steam to operate, the MTR membrane-based capture system is driven primarily by electric power. This direct, bolt-on approach to retrofitting carbon capture could potentially reduce the impact on the existing power plant, by minimal disruption of the existing facility’s infrastructure and operating procedures. This may also reduce the amount of retrofit downtime before the power plant can resume normal operations. A second objective was to reduce the cost of each ton of captured CO 2 while maintaining the existing 600 MW net output of the East Bend Station. With this aim in mind, various options to provide the necessary auxiliary power for the capture system were evaluated for the site. The full report describes in detail the overall design, layout and components of the entire EBS membrane capture system. The equipment and sizes, the capital cost estimate encompassing both engineering design and construction for the carbon capture process and balance of plant systems is presented. A detailed techno-economic analysis is also undertaken to examine the business case for capture.

01 COAL, LIGNITE, AND PEAT↗

Intrusion Detection System Alarm Station Operator Interface Improvements

To address Alarm Station operator performance, Portable Intrusion Detection System team gathered information concerning AS operator data needs when assessing alarms. The purpose was to improve the Portable Intrusion Detection System operator interface to ensure that critical information was quickly presented and easily accessible. To gather the data, the team used a Goal Directed Task Analysis approach. The method of analysis was to prepare a set of interview questions, interview selected AS operator experts, conduct the interviews, create a goal/decision/information hierarchy based on information gathered, and then apply the results to the operator interface. In applying the results, the team had to consider not only the Goal Directed Task Analysis -determined information needs of the Alarm Station operator end-user population, but also account for customer requirements and differences in domain. The constraints in implementing all situation awareness recommendations are summarized and initial potential solutions presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Remote methane sensor for emissions from pipelines and compressor stations using chirped-laser dispersion spectroscopy

Leak rates of methane (CH 4 ) from the natural gas supply chain result in lost profit from unsold product, public safety and property concerns due to potential explosion hazards, and a potentially large source of economic damages from legal liabilities. Yet large measurement challenges exist in identifying and quantifying CH 4 leak rates along the vast number and type of components in the natural gas supply chain. This is particularly true of the “midstream” components involved in the gathering, processing, compression, transmission, and storage of natural gas. This project developed and deployed new advances in chirped laser dispersion spectroscopy (CLaDS) to detect methane leaks from pipelines, compressor stations, and other midstream infrastructure from a remote position (standoff detection). The system was deployed from a van to measure fugitive methane leaks from a local compressor station as a proof-of-concept. The technique was validated through mobile laboratory measurements with in-situ sensors as well as controlled releases of methane. The system also mapped a plume from a controlled release of methane by tracking a small unmanned aerial system (sUAS) that carried a corner cube retroreflector which reflected the beam back to the instrument. The drone-based system quantified a leak rate to within 30% of the actual rate and localized the emission location within 5 m of the actual release location at standoff distances of 25-45 m. This sUAS-reflector tracking approach has benefits for mapping leak locations remotely using small drones flying around a facility. Benefits of a commercial sensor with these capabilities include reductions of leaks for pipeline operators (more profit), earlier detection of leaks to avoid catastrophic explosion hazards for public health and to mitigate property damage, and reduced methane emissions to the atmosphere (improving air quality).

03 NATURAL GAS↗

Dispenser Reliability: Materials R&D. A Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Report

Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations

08 HYDROGEN↗

Hydrogen Station Performance Evaluation (Final Report)

This project successfully designed and deployed a custom data acquisition system in 5 hydrogen fueling stations in California. The project also monitored and reported data to NREL on these stations over a 4 year period. These data have contributed to the large amount of information NREL has compiled on the current state of hydrogen fueling technology and infrastructure which has helped guide further R&D and other efficiency improvement efforts throughout the industry.

08 HYDROGEN↗

Second Target Station Project (STS) Steerable Optic Design & Testing Report

Multiple neutron scattering instrument concepts for the Spallation Neutron Source's Second Target Station (STS) incorporate advanced neutron optic designs which incorporate discrete mirrors rather than continuous neutron guides that were the standard for instruments in the First Target Station. These mirrors can be a few to several meters in length and must be stably supported and aligned as a single optic. In addition, due to the length of the STS instruments and the small size of the STS neutron beams, installation and alignment at the micron level of precision will be required, which is beyond the ability of today's survey & alignment technology. Thus, a means of remotely adjusting these mirrors with single digit micron resolution is needed. A Steerable Optic System was designed to provide the precision and resolution required to support and manipulate these large, heavy optics under beamline shielding. A mockup was developed to demonstrate and validate this system for use in neutron optic applications, and this document describes the design and testing results of that mockup.

43 PARTICLE ACCELERATORS↗

Physics Opportunities in the ORNL Spallation Neutron Source Second Target Station Era

The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maintaining quality similar to the FTS source. Furthermore, additional space for ten-tonne scale detectors may be available. We describe here exciting opportunities for neutrino physics, other particle and nuclear physics, and detector development using the FTS and STS neutrino sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗