Search NASA⌕ Search

SEARCH · Search NASA

Results for “Short range correlations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,486 records · Page 83

Characterization of the inner knot of the Crab: The site of the gamma-ray flares?

A particularly intriguing recent result from γ-ray astronomy missions is the detection of powerful flares from the Crab Nebula, which challenges the current understanding of pulsar wind nebulae and acceleration mechanisms. To search for the production site(s) of these flares, we conducted a multi-wavelength observing campaign using Keck, the Hubble Space Telescope (HST), and the Chandra X-ray Observatory. As the short timescales of the γ-ray flares (≲1 day) suggest a small emitting region, the Crab’s inner knot (about 0.6 arcsec from the pulsar) is a candidate site for such flaring. This paper describes observations of the inner knot, seeking to understand its nature and possible relationship with γ-ray flares. Using singular-value decomposition, analysis of the HST images yielded results consistent with traditional methods while substantially reducing some uncertainties. These analyses show that the knot’s intrinsic properties (especially size and brightness) are correlated with its (projected) separation from the pulsar. This characterization of the inner knot helps in constraining standard shock model parameters, under the assumption that the knot lies near the shocked surface. While the standard shock model gives good agreement in several respects, two puzzles persist: (a) the observed angular size of the knot relative to the pulsar–knot separation is much smaller than expected; and (b) the variable high degree of polarization (reported by others) is difficult to reconcile with a highly relativistic downstream flow. However, the IR–optical flux of the inner knot is marginally consistent with the shock accelerating most of the Nebula’s optical-emitting particles.

79 ASTRONOMY AND ASTROPHYSICS↗

Boron doped diamond synthesized from detonation nanodiamond in a C-O-H fluid at high pressure and high temperature

Boron doped diamond (BDD) was synthesized under high pressure and high temperature (HPHT) of 7 GPa, 1230 °C in a short time of 10 s from a powder mixtures of detonation nanodiamond (DND), pentaerythritol C{sub 5}H{sub 8}(OH){sub 4} and amorphous boron. SEM, TEM, XRD, XPS, FTIR and Raman spectroscopy indicated that BDD nano- and micro-crystals have formed by consolidation of DND particles (4 nm in size). XRD showed the enlargement of crystallites size to 6–80 nm and the increase in diamond lattice parameter by 0.02–0.07% without appearance of any microstrains. Raman spectroscopy was used to estimate the content of boron atoms embedded in the diamond lattice. It was found that the Raman diamond peak shifts significantly from 1332 cm{sup −1} to 1290 cm{sup −1} without appearance of any non-diamond carbon. The correlation between Raman peak position, its width, and boron content in diamond is proposed. Hydrogenated diamond carbon in significant amount was detected by IR spectroscopy and XPS. Due to the doping with boron content of about 0.1 at%, the electrical conductivity of the diamond achieved approximately 0.2 Ω{sup −1} cm{sup −1}. Reaction mechanism of diamond growth (models of recrystallization and oriented attachment) is discussed, including the initial stages of pentaerythritol pyrolysis and thermal desorption of functional groups from the surface of DND particles with the generation of supercritical fluid of low-molecular substances (H{sub 2}O, CH{sub 4}, CO, CO{sub 2}, etc.), as well as byproducts formation (B{sub 2}O{sub 3}, B{sub 4}C). - Highlights: • Boron doped diamond BDD synthesized from detonation nanodiamond, C{sub 5}H{sub 8}(OH){sub 4} and boron. • BDD nano/microcrystals are studied by XRD, SEM, TEM, XPS, FTIR, Raman spectroscopy. • Diamond growth and transition to electro-conductive state (0.2 Ω{sup −1} cm{sup −1}) is observed. • Correlations of Raman bands position and width versus boron content are considered. • High-pressure/temperature reaction mechanism (stages, routes, products) is described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quality of Life Outcomes From a Phase 2 Trial of Short-Course Radiation Therapy Followed by FOLFOX Chemotherapy as Preoperative Treatment for Rectal Cancer

Purpose: A prospective phase 2 trial of short-course (SC) radiation therapy (RT) with 25 Gy over 5 fractions, followed by 4 cycles of 5-fluorouracil, oxaliplatin, and leucovorin (mFOLFOX6) before surgery was recently completed at our institution. We present here the patient-reported quality of life (QOL) outcomes from this trial. Methods and Materials: Eighty patients with cT3/T4, any N, any M rectal adenocarcinoma planned for resection were enrolled between 2009 and 2012. The QOL data were obtained prospectively using the Functional Assessment of Cancer Therapy-Colon (FACT-C) questionnaire before RT, before surgery, and 1 year after surgery. The previously validated minimally importance difference (MID) method was used to measure clinically significant QOL changes in FACT-C scores for each patient across time points. We examined the role of ostomy on QOL. We also compared QOL with disease outcomes and physician-reported toxicity. Results: The FACT-C questionnaire was completed by 97% of patients before RT, 85% immediately before surgery, and 62% 1 year after surgery. There was no statistically significant change in mean FACT-C scores from before treatment to after treatment. The majority of patients had either no change or an increase in QOL 1 year after treatment using the MID method. There were significant changes in QOL between patients with ostomy versus no ostomy 1 year after treatment for functional well-being (FWB) (14.81 vs 20.52, P=.018) and the colorectal cancer subscale (CCS) using the MID method (P=.004). Patients without ostomy reported stable changes in bowel control 1 year after surgery. There was no statistically significant correlation between QOL and disease recurrence, pathologic complete response, pathologic T stage downstaging, or acute/late toxicity. Conclusions: SC-RT and sequential mFOLFOX6 as preoperative therapy for rectal cancer results in stable patient-reported QOL outcomes 1 year after treatment. These findings in conjunction with previously reported oncologic outcomes support further evaluation of this regimen in a phase 3 setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Radiation and Cardiovascular Adverse Effects After Androgen Deprivation and High-Dose Radiation Therapy in Prostate Cancer: Results From the DART 01/05 Randomized Phase 3 Trial

Purpose: To present data on the late toxicity endpoints of a randomized trial (DART 01/05) conducted to determine whether long-term androgen deprivation (LTAD) was superior to short-term AD (STAD) when combined with high-dose radiation therapy (HDRT) in patients with prostate cancer (PCa). Patients and Methods: Between November 2005 and December 2010, 355 eligible men with cT1c-T3aN0M0 PCa and intermediate-risk and high-risk factors (2005 National Comprehensive Cancer Network criteria) were randomized to 4 months of AD combined with HDRT (median dose, 78 Gy) (STAD) or the same treatment followed by 24 months of AD (LTAD). Treatment-related complications were assessed using European Organization for Research and Treatment of Cancer–Radiation Therapy Oncology Group and Common Terminology Criteria for Adverse Events v3.0 scoring schemes. Multivariate analyses for late toxicity were done using the Fine-Gray method. Results: The 5-year incidence of grade ≥2 rectal and urinary toxicity was 11.1% and 8.2% for LTAD and 7.6% and 7.3% for STAD, respectively. Compared with STAD, LTAD was not significantly associated with a higher risk of late grade ≥2 rectal toxicity (hazard ratio [HR] 1.360, 95% confidence interval [CI] 0.660-2.790, P=.410) or urinary toxicity (HR 1.028, 95% CI 0.495-2.130, P=.940). The multivariate analysis showed that a baseline history of intestinal comorbidity (HR 3.510, 95% CI 1.560-7.930, P=.025) and the rectal volume receiving >60 Gy (Vr60) (HR 1.030, 95% CI 1.001-1.060, P=.043) were the only factors significantly correlated with the risk of late grade ≥2 rectal complications. A history of previous surgical prostate manipulations was significantly associated with a higher risk of grade ≥2 urinary complications (HR 2.427, 95% CI 1.051-5.600, P=.038). Long-term AD (HR 2.090; 95% CI 1.170-3.720, P=.012) and a history of myocardial infarction (HR 2.080; 95% CI 1.130-3.810, P=.018) were significantly correlated with a higher probability of cardiovascular events. Conclusion: Long-term AD did not significantly impact urinary or rectal radiation-induced toxicity, although it was associated with a higher risk of cardiovascular events. Longer follow-up is needed to measure the impact of AD on late morbidity and non-PCa mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding the Space Weathering of Mercury Through Laboratory Experiments

Introduction: Airless surfaces across the solar system are continually modified by energetic particles from solar wind and micrometeoroid bombardment [1,2]. This process is known as space weathering, and it alters the chemical, microstructural, and optical properties of surface regoliths on airless bodies, including Mercury. On the Moon and S-type asteroids, the reflectance spectral signatures of space weathering include reddening (increasing reflectance with increasing wavelength), darkening (lowering of reflectance), and the attenuation of characteristic absorption bands [2]. Such spectral changes are driven by the production of Fe-bearing nanoparticles(npFe) through both solar wind irradiation and micrometeoroid bombardment. While our understanding of space weathering for the Moon and near-Earth S-types asteroids is advanced, insight into how these processes operate on other planetary bodies is limited. In particular, Mercury experiences a uniquely intense space weathering environment than planetary counterparts at 1 AU, including a moreintense solar wind flux and higher velocity micrometeoroid impacts [4]. Additionally, Mercury has a surface composition unique in the inner solar system, including regions of the surface with very low albedo known as the low reflectance material (LRM), which is enriched in carbon, likely graphite, up to 4wt.% [5].In addition, the concentration of Fe across Mercury’s surface islow (<2 wt.%) compared to the Moonor S-type asteroids asteroids[6]. Our understanding of the effects of space weathering on C-rich and Fe-poor phases is limited. Since Fe plays a critical role inthe development of space weathering characteristicson other airless surfaces(e.g., npFe), its limited availability may significantly affect the development of space weathering features in Mercury surface materials. We can simulate space weathering processes in the laboratory to explore their effects on the microstructural, chemical, and spectral characteristics of Mercury surface materials[7]. Here we used pulsed laser irradiation to simulate the short duration, high-temperature events associated with micrometeoroid impacts. We performed coordinated analyses including reflectance spectroscopy and electron microscopy to investigate the spectral, chemical, and microstructural changes in these mercurian analog samples. Methods: For these experiments, we usedforsteritic olivine with varying FeOcontents, a mineral phase proposed to be abundant on the surface of Mercury. We mixed each sample with graphite to simulate LRM regions of the surface. Wesynthesized the olivinesamplesat 1-bar at NASA’s Johnson Space Centerand prepared pressed powder pellets for laser irradiation [8].We prepared three samples, each with a base layer of olivineto maintain structural integrity and topped witha surface layer containing the graphite-olivine mixture: 1) Sample SC-001 San Carlos olivine(Fo90.91),2)Sample F-S-002 with0.05 wt.% FeO olivine, and 3) F-T-004 with 0.53 wt.% FeO olivine. Each sample was mixed with 5 wt.% powdered graphite and had grain sizes ranging from 45to 125μm. We irradiated each sample usinga pulsed Nd-YAG laser, (l=1064 nm, ~6 ns pulse duration, energy of 48 mJ/pulse) while undervacuumat Northern Arizona University. The laser was rastered1x and then 5x over the surfaceof each sample to simulate progressive space weathering. We collected in situreflectance spectra from the samples after each laser pulse witha Nicolet IS50 Fourier-Transform Infrared spectrometer (lfrom 0.65-2.5 μm). We used an FEI Nova NanoSEM200scanning electron microscope (SEM) and a Hitachi TM4000 Plus benchtop SEM at Purdue University to image the surface morphology and topography of the samples. We extracted thin sections for analysis in the transmission electron microscope(TEM)using the FEI Helios NanoLab 660 focused ion beam (FIB) SEM at the University of Arizona.We performed analysis of the microstructural and chemical characteristics of the samples using the 200 keV JEOL 2500 scanning TEM at Johnson Space Center. Reflectance Spectroscopy Results:Reflectance spectra for each sample are shown in Fig. 1.SC-001:The spectrum of the unirradiated sample exhibits a weak 1.0 μm absorption feature, associated with Fe2+in the olivine,and low overall reflectance (Fig. 1a). Thereflectance and the depth of the absorption band increases after 1x laser raster but are at their lowest after 5x laser rasters.F-T-004:The unirradiated sample has a blue-sloped spectrum with low reflectance without identifiable absorption features (Fig. 1b). With progressive laser irradiation, the sample reflectance increases and becomes strongly red-sloped.F-S-002:The unirradiated sample exhibits a dark, blue-slopedspectrum. The brightness of the sample increases significantly from <0.2average reflectance over >0.8 reflectance in the most irradiated sampleand thespectral slope also becomesslightly reddened (Fig. 1c). Microstructural and Chemical Analysis: Two primary alteration textures were observed in the samples exposed to simulated space weathering: 1) fluffy C-rich,and 2) vesiculated melt. The fluffy C-rich texture is composed oflow-densitydeposits distributed across the surface of the sample(Fig. 2A). Analysis of a FIB section extracted from a low-density C-rich region in sample SC-001 reveals multiple globule-type deposits, discrete from stacked graphite, likely produced via melting from the laser irradiation [9].The vesiculated melt textureis smooth and uniformly distributed across isolated regions of the sample surface. The vesicles measure up to 100s of nmin diameter. Analysis of a FIB section from this texture was extracted from sample F-T-004 reveals a layer of amorphous melt material, close to 100 nm thick and uniform across the FIB section (Fig. 2B). Isolated regions of this melt layer contain small nanoparticles, <5 nm in diameter. Chemical analysis through energy dispersive X-ray spectroscopy reveals the composition of this layer is enriched in Si and depleted in Mg and O compared to the underlying sample. Implications for Space Weathering on Mercury: Previous experiments simulating space weathering of Mercury have showndarkening and reddening of spectra[7,10].However, our use of low-Fe materials and graphite to create a sample set more analogous to the mercurian surface. Our results indicate that sample composition plays a significant and important role in the space weathering of Mercury. In particular, our spectral data demonstrates a strong correlation between spectral slope, Fe content, and simulated space weathering. While the variation in FeO content between samples F-S-002 and F-T-004 is <0.6 wt.%, the spectra deviate from flat to strongly red-sloped(F-T-004). This reddeningmay be linked to the presence of very small nanoparticles observed in the melt textures extracted from sample F-T-004. For the SC-001 sample, the fluffy C-rich textures may be developed by the amalgamation of small graphite particles into these unique morphologies. Such observations indicate that space weathering on Mercury may result in both familiar and new microstructural and chemical characteristics. References: [1]Hapke B. (2001) J. Geophys. Res.-Planet.,106,10039–10073. [2]Pieters C.M. and Noble S.K. (2016) J. Geophys. Res-Planet., 121, 1865–1884. [3] Lucey P.G., and Riner, M.A. (2011) Icarus,212, 451-462.[4]CintalaM.J.(1992)J. Geophys. Res.-Planet.,97,947–973.[5]Klima R.L.et al.(2018)Geophys.Res.Letters, 45, 2945–2953. [6]Nittler L.R., et al. (2011) Science 333, 1847-1850.[7]Sasaki S. and Kurahashi E. (2004) Space weathering on Mercury, Adv.Space Res., 33, 2152-2155.[8] Vander KaadenK.E., et al. (2018) LPSCXLIX, Abstract 1230. [9] McGlaun M.L. et al. (2019) LPSCL, Abstract 2019. [10] TrangD.et al. (2018)LPSCXLIX,Abstract2083

M S Thompson↗

Progress Toward Generation of a Navier-Stokes Database for a Harrier in Ground Effect

The Harrier YAV-8B aircraft is capable of vertical and short-field take-off and landing (V/STOL) by directing its four exhaust nozzles toward the ground, or conventional flight by rotating its nozzles into a horizontal position. The British Royal Air Force and the United States Marine Corps have used this aircraft for more than 30 years to provide a quick reaction time for troop support, and reduce the need for long runways. The success of this powered-lift (PL) vehicle has also prompted the more recent design of the Joint Strike Fighter (JSF). However there are significant safety issues that must be addressed when operating a PL vehicle in close proximity to the ground. Hot Gas Ingestion (HGI) by the inlets can result in a rapid loss of powered lift; and high-speed jet flows along the ground plane can induce low pressures underneath the vehicle, causing a 'suck-down' effect. Under these conditions, departure from controlled flight may occur. Moreover, unsteady ground vortices and jet fountains can affect the aircraft,s controllability and its proximity to ground troops. The viscous, time-dependent flow fields of PL vehicles are difficult to accurately and efficiently predict using Computational Fluid Dynamics (CFD). A number of researchers have used the time-dependent Reynolds-averaged Navier-Stokes (RANS) equations to compute flows for single and multiple jets in a cross-flow. A few have added some geometric complexity to the problem by computing flows for jet-augmented delta wings near a ground plane. Smith et.al. computed for the first time a single RANS solution about a simplified Harrier. This geometry included a fuselage, wing, leading edge root extension (LERX), inlets, and exhaust nozzles. All of these investigations cite two practical problems with computing these flows: 1) the need for improved solution accuracy; and, 2) the need for faster solution methods. We view the need for faster solution methods as key to improving the solution accuracy and making this class of computation more routine. One can hardly refine grids, explore the use of advanced turbulence models, and generate databases when it takes weeks of dedicated computer time for a single solution. Chaderjian, Ahmad, Pandya, and Murman have focused on reducing the time-to-solution for this very difficult and complex problem through process automation and exploitation of parallel computing. They began with the Harrier geometry reported, and added a deflected wing flap and empennage for greater realism. To date more than 80 solutions have been carried out. This paper will describe this process and progress made in reducing the time required to generate a simple longitudinal force and moment database for a Harrier in ground effect. It shows a typical snap-shot from an unsteady streakline animation, where fluid particles are colored by temperature. The ground vortex and a jet-fountain vortex are highlighted. It also shows a similar streakline image, where HGI occurs due to the vehicle in close proximity to the ground. It is show the mean lift coefficient as a function of angle of attack and height. The angle of attack range was 4 deg less than or = alpha less than or = 10 deg with an increment of 1 degree, and the height range was 10 ft less than or = h less than or = 30ft with an increment of 5 feet. This 35 solution database was extended to over 2500 cases using a monotone cubic-spline interpolation procedure. The suck-down effect (reduction of lift near the ground) is highlighted in the figure. The "cushion effect," the conventional reduction of lift as the vehicle moves out of ground effect, is also indicated. All 35 RANS solutions were obtained using 952 Silicon Graphics Origin 2000 and 3000 processors in dedicated mode for one week. Typically, 112 processors were assigned to each case. Some other cases used fewer processors to utilize all available CPUS. The final paper will report on the automation of the solution process, including: grid generation, job monitoring, solution completion criteria, and post processing. Moreover, improvements in parallel efficiency for a dual time-step algorithm for the RANS equations will also be presented. Results will be discussed in detail using unsteady streakline flow visualization to correlate unsteady flow structures with dominant aerodynamic frequencies. The stability derivatives, CL, and CL, will also be presented.

Chaderjian, Neal M.↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boiloff Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗