Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Solar Utility Network Deployment Acceleration

The National Rural Electric Cooperative Association (NRECA) is the national association representing 833 distribution and 62 generation and transmission (G&T) cooperatives. From booming suburbs to remote rural farming communities, America’s electric cooperatives are energy providers and engines of economic development and way of life for more than 19 million American homes, businesses, farms, and schools in 47 states across the U.S. Member owned and responsive, generally smaller than investor-owned and municipal utilities, often more nimble in services for members, co-ops provide the U.S. Department of Energy (DOE) with a strong partner for testing and accelerating utility-scale solar design, pricing, and delivery models.

14 SOLAR ENERGY↗

Ion dynamics driven by a strongly nonlinear plasma wake

Abstract In plasma wakefield accelerators, the wave excited in the plasma eventually breaks and leaves behind slowly changing fields and currents that perturb the ion density background. We study this process numerically using the example of a Facility for Advanced aCcelerator Experimental Tests (FACET) experiment where the wave is excited by an electron bunch in the bubble regime in a radially bounded plasma. Four physical effects underlie the dynamics of ions: (1) attraction of ions toward the axis by the fields of the driver and the wave, resulting in formation of a density peak, (2) generation of ion-acoustic solitons following the decay of the density peak, (3) positive plasma charging after wave breaking, leading to acceleration of some ions in the radial direction, and (4) plasma pinching by the current generated during the wave-breaking. The interplay of these effects results in the formation of various radial density profiles, which are difficult to produce in any other way.

Physics↗

THE LU ISOTOPIC COMPOSITION OF ACHONDRITES: CLOSING THE CASE FOR ACCELERATED DECAY OF {sup 176}LU

Studies of Lu–Hf isotope systematics in meteorites have produced apparent “ages” that are older than Pb–Pb ages and older than the estimated age of our solar system. One proposed explanation for this discrepancy is that irradiation by cosmic rays caused excitation of {sup 176}Lu to its short-lived isomer that then underwent rapid decay to {sup 176}Hf. This explanation can account for apparent excesses in {sup 176}Hf that correlate with Lu/Hf ratio. Mass balance requires that samples with measurable excess in {sup 176}Hf should also have measurable deficiencies in {sup 176}Lu on the order of 1‰–3‰. To unambiguously test the accelerated decay hypothesis, we have measured the {sup 176}Lu/{sup 175}Lu ratio in terrestrial materials and achondrites to search for evidence of depletion in {sup 176}Lu. To a precision of 0.1‰ terrestrial standards, cumulate and basaltic eucrites and angrites all have the same {sup 176}Lu/{sup 175}Lu ratio. Barring a subsequent mass-dependent fractionation event, these results suggest that the apparent excesses in {sup 176}Hf are not caused by accelerated decay of {sup 176}Lu, and so another hypothesis is required to explain apparently old Lu–Hf ages.

79 ASTRONOMY AND ASTROPHYSICS↗

IEC Quality Assurance Task Group 5: UV, Temperature, and Humidity (Presentation)

Taskgroup 5 (TG5) is concerned with a comparative aging standard incorporating factors including ultraviolet radiation and temperature. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for TG5 as well as providing an update on the experiments in progress.

14 SOLAR ENERGY↗

Effect of Catalyst and Catalyst Layer Composition on Catalyst Support Durability

Polymer electrolyte membrane fuel cells (PEMFCs) are efficient, zero-emission engines for the automotive sector. However, cost and durability are major barriers for the commercialization of PEMFCs. Degradation of the carbon support in the cathode catalyst layer due to high potential excursions caused by unmitigated events like H 2 starvation, or start-up/shutdown are still a major durability issue in PEMFCs. Catalyst support durability was studied by accelerated stress tests (ASTs) that included repeated potential cycling from 1.0 to 1.5 V. The effect of catalyst layer composition on carbon corrosion was studied using membrane electrode assemblies with different catalysts (Pt, PtCo), catalyst composition (catalyst wt.%, supports), ionomer composition (loading, and equivalent weights). The corrosion of the carbon support is similar between Pt and PtCo catalysts. However, the performance degradation rate is higher for the alloy catalysts due to differences in catalyst particle size and the transition metal’s leaching accelerating the performance degradation. The carbon loss is lower for catalysts with lower initial carbon loading (or higher catalyst wt.%), which is better for durability. However, the cumulative loss of carbon is identical for electrodes with the same catalyst support irrespective of catalyst and ionomer composition in the catalyst layer.

25 ENERGY STORAGE↗

Epoxy Adhesives for Stator Magnet Assembly in Stirling Radioisotope Generators (SRG)

As NASA seeks to fulfill its goals of exploration and understanding through missions planned to visit the moons of Saturn and beyond, a number of challenges arise from the idea of deep space flight. One of the first problems associated with deep space travel is electrical power production for systems on the spacecraft. Conventional methods such as solar power are not practical because efficiency decreases substantially as the craft moves away from the Sun. The criterion for power generation during deep space missions are very specific, the main points requiring high reliability, low mass, minimal vibration and a long lifespan. A Stirling generator, although fairly old in concept, is considered to be a potential solution for electrical power generation for deep space flight. A Stirling generator works on the same electromagnetic principles of a standard generator, using the linear motion of the alternator through the stationary stator which produces electric induction. The motion of the alternator, however, is produced by the heating and cooling dynamics of pressurized gases. Essentially heating one end and cooling another of a contained gas will cause a periodic expansion and compression of the gas from one side to the other, which a displacer translates into linear mechanical motion. NASA needs to confirm that the materials used in the generator will be able to withstand the rigors of space and the life expectancy of the mission. I am working on the verification of the epoxy adhesives used to bond magnets to the steel lamination stack to complete the stator; in terms of in-service performance and durability under various space environments. Understanding the proper curing conditions, high temperature properties, and degassing problems as well as production difficulties are crucial to the long term success of the generator. system and steel substrate used in the stator. To optimize the curing conditions of the epoxies, modulated differential scanning calorimetry analysis was done as a function of cure time and temperatures. Adhesion bond strength was tested at various temperatures with lap shear samples using Hiperco 50 substrate to ensure that the proper adhesive is being used. To try and solve the problem of bondline thickness, micro glass beads of 0.0017" in diameter were investigated to see if any other physical properties of the epoxy were affected. Efforts will be made to develop a standard, optimized, fabrication process/procedure of sub-scale magnet-stator assemblies for various adhesive performance evaluation studies under simulated generator conditions. Also, accelerated aging testing will be done in a pressurized canister with stator assembly samples for three years to verify if any degassing or thermal degradation of the epoxy occurs. The necessity of verifying the correct epoxy adhesive system for the stator magnet in the SRG is crucial because failure of the stator assembly would jeopardize the electrical system, and thereby the entire mission itself. My work involves specimen fabrications, testing, and data analyses of the epoxy adhesive system for the stator magnet in the SRG is crucial because failure of the stator assembly would jeopardize the electrical system, and thereby the entire mission itself.

Cater, George M.↗

Real-time testing of titanium sheet and extrusion coupon specimens subjected to Mach 2.7 supersonic cruise aircraft wing stresses and temperatures

The accuracy of three accelerated flight-by-flight test methods for material selection, and fatigue substantiation of supersonic cruise aircraft structure was studied. The real time stresses and temperatures applied to the specimens were representative of the service conditions in the lower surface of a Mach 2.7 supersonic cruise aircraft wing root structure. Each real time flight lasted about 65 minutes, including about one hour at (500 F) in the cruise condition. Center notched coupon specimens from six titanium materials were tested: mill-annealed, duplex-annealed, and triplex-annealed Ti-8Al-1Mo-1V sheets; mill-annealed Ti-8Al-1Mo-1V extrusion; mill-annealed Ti-6Al-4V sheet; and solution-treated and aged Ti-6Al-4V extrusion. For duplex-annealed Ti-8Al-1Mo-1V sheet, specimens with single spotweld were also tested. The test results were studied in conjunction with other related data from the literature for: material selection, structural fabrication, fatigue resistance of supersonic cruise aircraft structure, and fatigue test acceleration procedures for supersonic cruise aircraft.

Lunde, T.↗

A study on the creep behavior of alloy 709 using in-situ scanning electron microscopy

In this research, an experimental evaluation of creep properties of Alloy 709 in the temperature range of 750–850 °C was undertaken. Alloy 709 is a novel austenitic stainless steel with 20% Cr and 25% Ni by wt% that was developed for application in structural components of nuclear power plants. Creep rupture tests were conducted in an in-situ heating-loading and Scanning Electron Microscope (SEM) unit equipped with Electron Backscatter Diffraction (EBSD) detector and Energy Dispersive Spectroscopy (EDS). “Real-time” creep damage mechanisms of Alloy 709 at various stresses and temperatures using a flat, un-notched sample with continuously reducing cross-section is studied so that the failure and maximum creep damage occurred at the center of the sample where the in-situ SEM imaging could be focused. Accelerated creep tests at temperatures and stresses above service conditions were performed by employing multiple blocks of constant loads where the loads were increased once the sample attained constant creep rate, indicating a secondary creep regime. This technique ensures multiple data points can be obtained from the same test, saves the time required for an otherwise long-term creep test and usage of SEM. Further, Coincident Site Lattice (CSL) boundary maps were collected as control maps before testing, and the grain boundaries were observed during the creep test to understand the effect of grain boundary character on the creep damage mechanism. Void growth, grain boundary separation, and sliding were found to be the main creep mechanisms whose rate is dependent on stress and temperature. Failure mechanisms studied on the fracture surface using SEM fractography were correlated to the sample surface observations to create complementary information to better understand the underline creep mechanism of Alloy 709.

36 MATERIALS SCIENCE↗

Voltage holding study of 1 MeV accelerator for ITER neutral beam injector

Voltage holding test on MeV accelerator indicated that sustainable voltage was a half of that of ideal quasi-Rogowski electrode. It was suggested that the emission of the clumps is enhanced by a local electric field concentration, which leads to discharge initiation at lower voltage. To reduce the electric field concentration in the MeV accelerator, gaps between the grid supports were expanded and curvature radii at the support corners were increased. After the modifications, the accelerator succeeded in sustaining -1 MV in vacuum without beam acceleration. However, the beam energy was still limited at a level of 900 keV with a beam current density of 150 A/m{sup 2} (346 mA) where the 3 x 5 apertures were used. Measurement of the beam profile revealed that deflection of the H{sup -} ions was large and a part of the H{sup -} ions was intercepted at the acceleration grid. This causes high heat load on the grids and the breakdowns during beam acceleration. To suppress the direct interception, new grid system was designed with proper aperture displacement based on a 3D beam trajectory analysis. As the result, the beam deflection was compensated and the voltage holding during the beam acceleration was improved. Beam parameter of the MeV accelerator was increased to 980 keV, 185 A/m{sup 2} (427 mA), which is close to the requirement of ITER accelerator (1 MeV, 200 A/m{sup 2}).

43 PARTICLE ACCELERATORS↗

An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II

Purpose: A helical tomotherapy accelerator presents a dosimetric challenge because, to this day, there is no internationally accepted protocol for the determination of the absolute dose. Because of this reality, we investigated the different alternatives for characterizing and measuring the absolute dose of such an accelerator. We tested several dosimetric techniques with various metrological traceabilities as well as using a number of phantoms in static and helical modes. Methods: Firstly, the relationship between the reading of ionization chambers and the absorbed dose is dependent on the beam quality value of the photon beam. For high energy photons, the beam quality is specified by the tissue phantom ratio (TPR{sub 20,10}) and it is therefore necessary to know the TPR{sub 20,10} to calculate the dose delivered by a given accelerator. This parameter is obtained through the ratio of the absorbed dose at 20 and 10 cm depths in water and was measured in the particular conditions of the tomotherapy accelerator. Afterward, measurements were performed using the ionization chamber (model A1SL) delivered as a reference instrument by the vendor. This chamber is traceable in absorbed dose to water in a Co-60 beam to a water calorimeter of the American metrology institute (NIST). Similarly, in Switzerland, each radiotherapy department is directly traceable to the Swiss metrology institute (METAS) in absorbed dose to water based on a water calorimeter. For our research, this traceability was obtained by using an ionization chamber traceable to METAS (model NE 2611A), which is the secondary standard of our institute. Furthermore, in order to have another fully independent measurement method, we determined the dose using alanine dosimeters provided by and traceable to the British metrology institute (NPL); they are calibrated in absorbed dose to water using a graphite calorimeter. And finally, we wanted to take into account the type of chamber routinely used in clinical practice and therefore measured the dose using a Farmer-type instrument (model NE 2571) as well. Results: We found the tomotherapy TPR{sub 20,10} value to be around 0.629, which is close to a 4 MV conventional linear accelerator value. During static irradiation, the secondary standard and the alanine dosimeters were compatible within 0.5%. The A1SL relative deviation to the secondary standard was 1.2% and the NE2571 relative deviation to the secondary standard was -1.7%. The measurement in dynamic helical mode found the different dosimeters compatible within 1.4% and the alanine dosimeters and the secondary standard were even found under 0.2%. Conclusions: We found that the different methods are all within uncertainties as well as globally coherent, and the specific limitations of the various dosimeters are discussed in order to help the medical physicist design an independent reference system. We demonstrated that, taking into account the particular reference conditions, one can use an ionization chamber calibrated for conventional linear accelerators to assert the absolute dose delivered by a tomotherapy accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Analysis of Fuel Cell Electrocatalyst Degradation on Alternate Carbon Supports

Understanding the mechanisms associated with Pt/C electrocatalyst degradation in proton exchange membrane fuel cell (PEMFC) cathodes is critical for the future development of higher-performing materials; however, there is a lack of information regarding Pt coarsening under PEMFC operating conditions within the cathode catalyst layer. We report a direct and quantitative 3D study of Pt dispersions on carbon supports (high surface area carbon (HSAC), Vulcan XC-72, and graphitized carbon) with varied surface areas, graphitic character, and Pt loadings ranging from 5 to 40 wt %. This is accomplished both before and after catalyst-cycling accelerated stress tests (ASTs) through observations of the cathode catalyst layer of membrane electrode assemblies. Electron tomography results show Pt nanoparticle agglomeration occurs predominantly at junctions and edges of aggregated graphitized carbon particles, leading to poor Pt dispersion in the as-prepared catalysts and increased coalescence during ASTs. Tomographic reconstructions of Pt/HSAC show much better initial Pt dispersions, less agglomeration, and less coarsening during ASTs in the cathode. However, a large loss of the electrochemically active surface area (ECSA) is still observed and is attributed to accelerated Pt dissolution and nanoparticle coalescence. Moreover, a strong correlation between Pt particle/agglomerate size and measured ECSA is established and is proposed as a more useful metric than average crystallite size in predicting degradation behavior across different catalyst systems.

36 MATERIALS SCIENCE↗

Stable White Coatings

In a previous research program for the Jet Propulsion- Laboratory, extensive studies led to the development and specifications of three zinc oxide-pigmented thermal-control coatings. The principal objectives of this program are: improvement of the three paints (as engineering materials), determination of the validity of our accelerated space-simulation testing, and continuation of the zinc oxide photolysis studies begun in the preceding program. Specific tasks that are discussed include: improvement of potassium silicate coatings as engineering materials and elucidation of their storage and handling problems; improvement of methyl silicone coatings as engineering materials; studies of zinc oxide photolysis to establish reasons for the observed stability of zinc oxide; and determination of space-simulation parameters such as long-term stability (to 8000 ESH), effect of coating surface temperature on the rate of degradation, and validity of accelerated testing (by reciprocity and wavelength dependency studies).

COATING↗

Design, Synthesis, and Evaluation of Noble Metal Nanoparticles and In Situ-Decorated Carbon-Supported Nanoparticle Electrocatalysts Using Hypergolic Reactions

Here, we report the first synthesis of metal nanoparticles and supported metal nanoparticles on carbon by using hypergolic reactions. Specifically, we report the synthesis of noble metal nanoparticles (Pt, Ag, and Au) using sodium hydride (NaH) as both an ignition trigger and a reducing agent for the corresponding metal salt precursors. In addition, we report the one-step, in situ synthesis of Pt nanoparticles supported on carbon by adding sucrose as the carbon source. The hypergolically synthesized nanoparticles display elliptical morphology and are more crystalline compared with those conventionally synthesized in solution using sodium borohydride (NaBH 4 ). When tested as electrocatalysts, the hypergolic Pt nanoparticles exhibit more than 2 times higher specific electrochemical active surface area (ECSA) and a higher half-wave potential (E 1/2 ) of 0.94 V vs the reversible hydrogen electrode (RHE) compared to the conventionally synthesized ones. In addition, the electrocatalyst based on the in situ synthesized carbon that was decorated with the Pt nanoparticles synthesized hypergolically outperforms an analogous, state of the art, commercial PtC system. For example, the former shows an attractive E 1/2 (0.94 V) compared with 0.9 V for the commercial PtC. Accelerated durability tests (ADT) in an alkaline environment add another advantage. After 10 000 cycles, the hypergolically synthesized system shows a smaller reduction of E 1/2 and less degradation compared to the commercial PtC (10 mV compared to ∼30 mV). The work described here represents the first reported synthesis using hypergolic reactions of metal nanoparticles as well as supported metal nanoparticles. The properties of the resulting electrocatalysts demonstrate the versatility and promise of the new approach in materials synthesis and open new avenues for further investigation as electrocatalysts.

Chalmpes, Nikolaos↗

Lifetime predictions for dimmable two-channel drivers for color tuning luminaires

Two-channel tunable white lighting (TWL) systems represent the next wave of solid-state lighting (SSL) systems and promise flexibility in light environment while maintaining the high reliability and luminous efficacy expected with SSL devices. TWL systems utilize LED assemblies consisting of two different LED spectra (i.e., often a warm white assembly and a cool white assembly) that are integrated into modules. While these systems provide the ability to adjust the lighting spectrum to match the physiology needs of the task at hand, they also are a potentially more complex lighting system from a performance and reliability perspective. We report an initial study on the reliability performance of such lighting systems including an examination of the lumen maintenance and chromaticity stability of warm white and cool white LED assemblies and the multi-channel driver that provides power to the assemblies. Accelerated stress tests including operational bake tests conducted at 75°C and 95°C were used to age the LED modules, while more aggressive temperature and humidity tests were used for the drivers in this study. Small differences in the performance between the two LED assemblies were found and can be attributed to the different phosphor chemistries. The lumen maintenances of both LED assemblies were excellent. The warm white LED assemblies were found to shift slightly in the green color direction over time while the cool white LED assemblies shifted slightly in the yellow color direction. The net result of these chromaticity shifts is a small, barely perceptible reduction in the tuning range after 6,000 hours of exposure to an accelerating elevated temperature of 75°C.

Chromaticity↗

Dosimetry experiments at the MEDUSA Facility (Little Mountain).

A series of experiments on the MEDUSA linear accelerator radiation test facility were performed to evaluate the difference in dose measured using different methods. Significant differences in dosimeter-measured radiation dose were observed for the different dosimeter types for the same radiation environments, and the results are compared and discussed in this report.

43 PARTICLE ACCELERATORS↗

Round 2 Update of Stress Testing Results for Organic Light-Emitting Diode Panels and Luminaires

Organic light-emitting diode (OLED) sources are a potential solid-state lighting technology for use in indoor lighting applications. Some of the advantages offered by OLEDs include thin profiles, low glare, diffuse lighting, and unique form factors. The U.S. Department of Energy (DOE) has released five reports about OLED technologies to provide information and analysis to the lighting industry. These reports include the evaluation of two different field deployment sites, a market analysis, and two independent assessments of the performance of select commercially available OLED products. This report builds on earlier DOE efforts with OLED technology by updating information about previously benchmarked OLED products (i.e., the Chalina luminaire from Acuity Brands and the Brite 2 and Brite Amber panels from OLEDWorks) in accelerated stress tests (ASTs). In addition, this report also provides an initial analysis of the performance of recently released OLED products—the Brite 3 panels from OLEDWorks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen evolution in nickel-water heat pipes.

A study was made of the evolution of hydrogen gas in nickel-water heat pipes for the purpose of investigating methods of accelerated life testing. The data were analyzed in terms of a phenomenological corrosion model of heat pipe degradation which incorporates corrosion and oxidation theory and contains parameters which can be determined by experiment. The gas was evolved with a linear time dependence and an exponential temperature dependence with an activation energy of 1.03 x 10 to the minus 19th joules. A flow-rate dependence of the gas evolution was found in the form of a threshold. The results were used to predict usable lifetimes of heat pipes operated at normal operating conditions from results taken under accelerated operating conditions.

Anderson, W. T.↗

Developmental status of thermionic materials.

Description of the reference materials selected for the major components of the unit cell of a thermionic pile element (TFE), the out-of-pile and in-pile test results, and current efforts for improving the life and performance of thermionic fuel elements. The component materials are required to withstand the fuel burnup and fast neutron fluence dictated by the thermionic reactor system. Tungsten was selected as the cladding material because of its compatibility with both the carbide and the oxide fuel materials. Niobium was selected as the collector material because its thermal expansion coefficient matches closely with that of the thin aluminum oxide layer used to electrically insulate the collector from the TFE sheath. An unfueled converter has performed stably over 41,000 hr. Accelerated irradiation tests have attained burnups equivalent to that for 40,000 hr of the thermionic reactor under consideration.

Yang, L.↗