Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Directional clogging and phase separation for disk flow through periodic and diluted obstacle arrays

We model collective disk flow though a square array of obstacles as the flow direction is changed relative to the symmetry directions of the array. At lower disk densities there is no clogging for any driving direction, but as the disk density increases, the average disk velocity decreases and develops a drive angle dependence. For certain driving angles, the flow is reduced or drops to zero when the system forms a heterogeneous clogged state consisting of high density clogged regions coexisting with empty regions. The clogged states are fragile and can be unclogged by changing the driving angle. For large obstacle sizes, we find a uniform clogged state that is distinct from the collective clogging regime. Within the clogged phases, depinning transitions can occur as a function of increasing driving force, with intermittent motion appearing just above the depinning threshold. The clogging is robust against the random removal or dilution of the obstacle sites, and the disks are able to form system-spanning clogged clusters even under increasing dilution. If the dilution becomes too large, however, the clogging behavior is lost.

36 MATERIALS SCIENCE↗

Perovskite-sensitized β-Ga 2 O 3 nanorod arrays for highly selective and sensitive NO 2 detection at high temperature

Amongst various gaseous pollutants, NO 2 is one of the major exhausts originating from fossil fuel and gas combustions in vehicle engines and power plants at high temperature. Under such a scenario, in situ and real-time gas detection and monitoring solutions are largely limited, which hinders the energy-efficient and resource-saving operations of these advanced energy systems. Herein, a new type of perovskite-sensitized β-Ga 2 O 3 nanorod-array has been successfully fabricated to detect NO x at high temperature selectively and sensitively. The demonstrated gas sensors are highly sensitive to NO 2 at 800 °C, with excellent reversible and reproducible response characteristics. Through the surface decoration of perovskite-type La 0.8 Sr 0.2 CoO 3 (LSCO) nanoparticles, the sensitivity of β-Ga 2 O 3 nanorod array gas sensors is enhanced by nearly an order of magnitude, along with much faster response dynamics. A remarkable selectivity toward oxidative gases was also demonstrated with the robust differentiation of NO 2 .

36 MATERIALS SCIENCE↗

High-energy sources at low radio frequency: the Murchison Widefield Array view of Fermi blazars

Low-frequency radio arrays are opening a new window for the study of the sky, both to study new phenomena and to better characterize known source classes. Being flat-spectrum sources, blazars are so far poorly studied at low radio frequencies. In this paper, we characterize the spectral properties of the blazar population at low radio frequency, compare the radio and high-energy properties of the gamma-ray blazar population, and search for radio counterparts of unidentified gamma-ray sources. We cross-correlated the 6100 deg 2 Murchison Widefield Array Commissioning Survey catalogue with the Roma blazar catalogue, the third catalogue of active galactic nuclei detected by Fermi-LAT, and the unidentified members of the entire third catalogue of gamma-ray sources detected by Fermi-LAT. When available, we also added high-frequency radio data from the Australia Telescope 20 GHz catalogue. We find low-frequency counterparts for 186 out of 517 (36%) blazars, 79 out of 174 (45%) gamma-ray blazars, and 8 out of 73 (11%) gamma-ray blazar candidates. The mean low-frequency (120–180 MHz) blazar spectral index is (α low ) = 0.57 ± 0.02: blazar spectra are flatter than the rest of the population of low-frequency sources, but are steeper than at ~GHz frequencies. Low-frequency radio flux density and gamma-ray energy flux display a mildly significant and broadly scattered correlation. Ten unidentified gamma-ray sources have a (probably fortuitous) positional match with low radio frequency sources. Low-frequency radio astronomy provides important information about sources with a flat radio spectrum and high energy. However, the relatively low sensitivity of the present surveys still misses a significant fraction of these objects. Finally, upcoming deeper surveys, such as the GaLactic and Extragalactic All-Sky MWA (GLEAM) survey, will provide further insight into this population.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Tests of Lateral Bedload Transport Induced by a Yawed Submerged Vane Array in Open-Channel Flows

This work proposes the use of an array of yawed porous vanes to control the lateral bedload transport by locally steering bedform migration and maximize the amount of sediments redirected toward a potential sediment extraction system or bypass channel. A laboratory experiment was conducted in a quasifield-scale channel with an array of permeable vanes installed on one side, in live-bed conditions under bedload dominant regime, i.e., negligible suspended load. A baseline experiment without vanes was also performed for comparison. The evolution of migrating bedforms of different scales was tracked in space and time using a high-resolution, state-of-the-art laser scanning device. The bedload transport rate in the streamwise direction was first calculated using bedforms’ geometry and migration velocity, and then spatially distributed over the entire monitored area using a new Eulerian-averaged grid-mapping method. This allowed us to introduce a new methodology to estimate the lateral bedload transport using control volume theory and applying mass conservation. Quantitative assessments of lateral bedload transport along the channel yield consistent results, suggesting that the vanes effectively move sediments laterally as intended. Under the investigated setup, the maximum lateral sediment transport rate ranges from 9% to 18% of the whole domain-averaged streamwise transport rate. The developed methodology also allowed to identify the location where sediment capture could be maximized for the given vane spatial distribution.

42 ENGINEERING↗

Fine positioning of a poloidal probe array

Multipoint detection is an essential requirement for investigating plasma turbulence which is a highly nonlinear phenomenon in space and time. We have fabricated an array of 64-channel poloidal probes surrounding the linear cylindrical plasma named LMD-U in order to study turbulence properties, particularly the nonlinear mode couplings, in the domain of poloidal wave number and frequency. However, misalignments of probe tips produce spurious modes, which do not exist in the real plasma, to distort the precise wave number measurements. The paper presents the description of the 64-channel poloidal probe array with means to adjust the probe positions, with discussion on the effects of the misalignments on the wave number measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral gap of shear Alfven waves in a periodic array of magnetic mirrors

A multiple magnetic mirror array is formed at the Large Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)] to study axial periodicity-influenced Alfven spectra. Shear Alfven waves (SAW) are launched by antennas inserted in the LAPD plasma and diagnosed by B-dot probes at many axial locations. Alfven wave spectral gaps and continua are formed similar to wave propagation in other periodic media due to the Bragg effect. The measured width of the propagation gap increases with the modulation amplitude as predicted by the solutions to Mathieu's equation. A two-dimensional finite-difference code modeling SAW in a mirror array configuration shows similar spectral features. Machine end-reflection conditions and damping mechanisms including electron-ion Coulomb collision and electron Landau damping are important for simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of microsecond current prepulse for dramatic improvements of wire array Z-pinch implosion

The Sphinx machine [F. Lassalle et al., 'Status on the SPHINX machine based on the 1microsecond LTD technology'] based on microsecond linear transformer driver (LTD) technology is used to implode an aluminium wire array with an outer diameter up to 140 mm and maximum current from 3.5 to 5 MA. 700 to 800 ns implosion Z-pinch experiments are performed on this driver essentially with aluminium. Best results obtained before the improvement described in this paper were 1-3 TW radial total power, 100-300 kJ total yield, and 20-30 kJ energy above 1 keV. An auxiliary generator was added to the Sphinx machine in order to allow a multi microsecond current to be injected through the wire array load before the start of the main current. Amplitude and duration of this current prepulse are adjustable, with maxima {approx}10 kA and 50 {mu}s. This prepulse dramatically changes the ablation phase leading to an improvement of the axial homogeneity of both the implosion and the final radiating column. Total power was multiplied by a factor of 6, total yield by a factor of 2.5 with a reproducible behavior. This paper presents experimental results, magnetohydrodynamic simulations, and analysis of the effect of such a long current prepulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma/ion-controlled metal catalyst saturation: Enabling simultaneous growth of carbon nanotube/nanocone arrays

It is shown that the simultaneous saturation of Ni nanoparticles used as catalyst for vertically aligned carbon nanotube and nanocone arrays can be improved in low-temperature plasma- or ion-assisted processes compared with neutral gas-based routes. The results of hybrid multiscale numerical simulations of the catalyst nanoarrays (particle sizes of 2 and 10 nm) saturation with carbon show the possibility of reducing the difference in catalyst incubation times for smallest and largest catalyst particles by up to a factor of 2. This approach is generic and provides process conditions for simultaneous nucleation and growth of uniform arrays of vertically aligned nanostructures.

36 MATERIALS SCIENCE↗

Spatial dynamics of the light emission from a microplasma array

The spatial dynamics of the optical emission from an array of 50x50 individual microplasma devices is reported. The array is operated in noble gas at atmospheric pressure with an ac voltage. The optical emission is analyzed with phase and space resolution. It has been found that the emission is not continuous over the entire ac period, it occurs only twice in each cycle. Each of the observed emission phases shows a self-pulsing of the discharge, with several bursts of emission of a fixed width and repetition rate. Cross-talk between the individual devices can be observed through spatially resolved measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The potential for intensity interferometry with {gamma}-ray telescope arrays

Intensity interferometry exploits a quantum optical effect in order to measure objects with extremely small angular scales. The first experiment to use this technique was the Narrabri intensity interferometer, which was successfully used in the 1970s to measure 32 stellar diameters at optical wavelengths; some as small as 0.4 milli-arcseconds. The advantage of this technique, in comparison with Michelson interferometers, is that it requires only relatively crude, but large, light collectors equipped with fast (nanosecond) photon detectors. Ground-based {gamma}-ray telescope arrays have similar specifications, and a number of these observatories are now operating worldwide, with more extensive installations planned for the future. These future instruments (CTA, AGIS, completion 2015) with 30-90 telescopes will provide 400-4000 different baselines that range in length between 50 m and a kilometre. Intensity interferometry with such arrays of telescopes attains 50 {mu}-arcsecond resolution for a limiting m{sub v}{approx}8.5. Phase information can be extracted from the interferometric measurement with phase closure, allowing image reconstruction. This technique opens the possibility of a wide range of studies amongst others, probing the stellar surface activity and the dynamic AU scale circumstellar environment of stars in various crucial evolutionary stages. Here we focuse on the astrophysical potential of an intensity interferometer utilising planned new {gamma}-ray instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification and quantification of components in ternary vapor mixtures using a microcantilever sensor array and a neural network

We report the experimental details on the successful application of the electronic nose approach to identify and quantify components in ternary vapor mixtures. Preliminary results have recently been presented [L. A. Pinnaduwage et al., Appl. Phys. Lett. 91, 044105 (2007)]. Our microelectromechanical-system-based electronic nose is composed of a microcantilever sensor array with seven individual sensors used for vapor detection and an artificial neural network for pattern recognition. A set of custom vapor generators generated reproducible vapor mixtures in different compositions for training and testing of the neural network. The sensor array was selected to be capable of generating different response patterns to mixtures with different component proportions. Therefore, once the electronic nose was trained by using the response patterns to various compositions of the mixture, it was able to predict the composition of 'unknown' mixtures. We have studied two vapor systems: one included the nerve gas simulant dimethylmethyl phosphonate at ppb concentrations and water and ethanol at ppm concentrations; the other system included acetone, water, and ethanol all of which were at ppm concentrations. In both systems, individual, binary, and ternary mixtures were analyzed with good reproducibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planar nanowire arrays formed by atomic-terrace low-angle shadowing

A relatively simple method for preparation of planar nanowire arrays on vicinal substrates by molecular beam epitaxy is presented. The atomic step-and-terrace morphology of vicinal substrates is used to produce a shadowing effect on a highly collimated molecular beam at an oblique incidence to the substrate. The collimation is achieved by placing the evaporation source at a large working distance (40-100 cm) from the substrate. The method's capabilities have been demonstrated by preparation of arrays of Ag and Au nanowires on vicinal Si(111) and {alpha}-Al{sub 2}O{sub 3} (0001) substrates. Nanowires with a width of down to 10-15 nm and a thickness of 1.5 nm have been readily achieved.

36 MATERIALS SCIENCE↗

Magnetic flux array for spontaneous magnetic reconnection experiments

Experimental investigation of reconnection in magnetized plasmas relies on accurate characterization of the evolving magnetic fields. In experimental configurations where the plasma dynamics are reproducible, magnetic data can be collected in multiple discharges and combined to provide spatially resolved profiles of the plasma dynamics. However, in experiments on spontaneous magnetic reconnection recently undertaken at the Versatile Toroidal Facility at MIT, the reconnection process is not reproducible and all information on the plasma must be collected in a single discharge. This paper describes a newly developed magnetic flux array which directly measures the toroidal component of the magnetic vector potential, A{sub {phi}}. From the measured A{sub {phi}}, the magnetic field geometry, current density, and reconnection rate are readily obtained, facilitating studies of the three-dimensional dynamics of spontaneous magnetic reconnection. The novel design of the probe array allows for accurate characterization of profiles of A{sub {phi}} at multiple toroidal angles using a relatively small number of signal channels and with minimal disturbance of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Gamma-ray Burst Detector Based on the Silicon Drift Detector Array and Scintillators

We propose a gamma-ray burst (GRB) detector combining the silicon drift detector (SDD) array and scintillators with broadband X-ray and gamma-ray coverage (0.5-1000 keV or more), high energy resolution (2-10%) and high time resolution ({approx}{mu}s) in space. To realize such compact high-performance detector without photomultiplier tubes, we constructed proto-type model using KETEK SDD with a detection area of 1 cm{sup 2} and BGO crystal. The detector shows a very good performance. Obtained FWHM energy resolution was 191 eV at 5.9 keV in the SDD, while 6.5 % at 662 keV in the BGO at -30 deg. C. Evaluation of the 7 channel SDD array and development of analog ASIC for its readout are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ growth of aligned CdS nanowire arrays on Cd foil and their optical and electron field emission properties

Aligned CdS nanowire arrays have been fabricated directly on a Cd foil via a simple solvothermal method. The metal Cd foil serves as both the Cd source and substrate during fabrication of the aligned CdS nanowire arrays. The morphology, structure, and composition of the samples are characterized by x-ray diffraction, field-emission scanning electron microscopy, transmission electron microscopy, energy-dispersive x-ray spectroscopy, and selected-area electron diffraction, and the results reveal the formation of aligned single-crystalline CdS nanowires with uniform diameters of 20-40 nm. The photoluminescence and Raman spectra disclose the optical properties of the products and the possible growth mechanism is suggested. The electron field emission properties are also investigated and analyzed. The screening effect is observed to play a vital role in the electron field emission properties due to the coalescent ends of the nanowires. The simple synthesis methodology in conjunction with the good field emission and optical properties makes the materials both scientifically and technologically interesting.

36 MATERIALS SCIENCE↗

High-resolution hard x-ray spectroscopy of high-temperature plasmas using an array of quantum microcalorimeters

Quantum microcalorimeters show promise in being able to fully resolve x-ray spectra from heavy highly charged ions, such as would be found in hot plasmas with temperatures in excess of 50 keV. Quantum microcalorimeter arrays are able to achieve this as they have a high-resolving power and good effective quantum efficiency for hard x-ray photons up to 60 keV. To demonstrate this, we present a measurement using an array of thin HgTe quantum microcalorimeters to measure the K-shell spectrum of hydrogenlike through carbonlike praseodymium (Z=57). With this device we are able to attain a resolving power, E/{delta}E, of 1000 at a photon energy of 37 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cerreto di Spoleto (Umbria-Italy): Seismic amplification at the ENEA local array stations

The Nerina valley, where Borgo Cerreto is located, is surrounded by the Apennine mount chain at the top of which lies the historical centre of Cerreto di Spoleto. The study is part of a research project aiming at analysing natural disasters and their impact on the Italian cultural heritage. Within the framework of this research project, local seismic records were analysed for both the carbonate ridge and the bordering alluvial valley. The choice of Cerreto di Spoleto as a test site derives from the analysis of Italian seismic hazard maps, obtained in terms of peak ground velocity and taking into account regional geology. The maps highlight the considerable seismic hazard which characterises the Apennine belt and its possible increase due to the effect of alluvial deposits. To this aim, ENEA installed in the 80's an accelerometric array (CODISMA up to 2000 and, in the following years, ETNA; for more detailed description see [1]. The 14 October event, was recorded both at the roof of CSM and at BCT stations. This is important to check the features observed comparing the FAS of acceleration at CSM and BCT during the 26 September events. Unfortunately the station at CSM basement did not record the above mentioned events but several aftershocks were recorded at each array station. Velocimetric records of both ambient noise and small-magnitude earthquakes were analysed in order to identify amplification conditions. The analysis was carried out in the time domain, through directional energy evaluation, and in the frequency domain, through H/V spectral ratios and spectral ratios with respect to a reference station.

58 GEOSCIENCES↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗