Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time X-ray Diffraction Measurements of Shocked Polycrystalline Tin and Aluminum

A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35-ns pulse. The characteristic Kα lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic Kβ line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3-mm by 6-mm spot and 1° full-width-half-maximum (FWHM) angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5°. A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device (CCD) camera through a coherent fiberoptic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1-mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic (fcc) aluminum lattice with no phase transformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and expected perfomance of the MAXI mission for the JEM/ISS

MAXI (Monitor of All-sky X-ray Image) is the first payload to be attached on JEM-EF (Kibo exposed facility) of ISS. It provides an all sky X-ray image every ISS orbit. Only with a few weeks scan, MAXI is expected to make a milli-Crab X-ray all sky map excluding bright region around the sun. Thus, MAXI does not only inform X-ray novae and transients rapidly to world astronomers if once they occur, but also observes long-term variability of Galact ic and extra-Galactic X-ray sources. MAXI also provides an X-ray source catalogue at that time with diffuse cosmic X-ray background. MAXI consists of two kinds of detectors, position sensitive gas-proportional counters for 2-30 keV X-rays and CCD cameras for 0.5-10 keV X-rays. All instruments of MAXI are now in final phase of pre-launching tests of their flight modules. We are also carrying out performance tests for X-ray detectors and collimators. Data processing and analysis software including alert system on ground are being developed by mission team. In this paper we report an overview of final instruments of MAXI and capability of MAXI.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements from a Compact Cost-Effective Beamline for the THC14 PET Cyclotron

The THC14 PET Cyclotron produced by THALES specifies two compact cost-effective beamlines for high current PET radioisotope production. The design and development of the beamline system was reported previously in NIM B 261 (2007) pp 809-812. This paper describes the successful testing of this compact beamline at the first installation. A series of measurement data are presented starting from low current scintillator image data, higher current beam diagnostic data (baffles, collimators, targets) and finally a simultaneous dual beam run on Faraday Cups. The beamline system has proven to be a flexible and valuable tool for optimizing high current beam intensity distribution on target in a well-instrumented manner. This ability to tailor the beam characteristics for the target is particularly important as high power targets are developed which can handle very high beam currents.

43 PARTICLE ACCELERATORS↗

NIF unconverted light and its influence on DANTE measurements

NIF laser facility produces 1053 nm light and a fundamental requirement for NIF is to give up to 1.8 MJ of 351 nm light for target physics experiments. The 351 nm light is provided by frequency tripling the 1053 nm light in nonlinear crystals in the final optics assembly, just before the laser light enters the target chamber. Since this tripling process is not 100% efficient, unconverted light from the conversion process also enters the chamber. This unconverted light does not directly hit the target but it can strike target support structures at average intensities of few TW/cm{sup 2} where it can generate unwanted, background soft x-rays that are measured by the soft x-ray diagnostic DANTE installed on the NIF target chamber. This diagnostic quantifies the x-radiation intensity inside the hohlraum by measuring the x-ray flux coming from the target's laser entrance hole. Due to its centimeter wide field of view, it integrates x-ray emission from both the flux exiting a hohlraum laser entrance hole and from the target support structure irradiated by residual 1{omega} and 2{omega} unconverted light. This work gives quantitative evaluations of the unconverted light for the first time and the effects on DANTE measurements for the future NIF tuning experiment called ''Shock timing.'' Emission spectra are significantly modified leading to an overestimation of radiative temperature during the foot of the laser pulse since background x-rays are predominant in first two DANTE channel measurements. Mitigations of these effects by coating silicon paddle with plastic, using a smaller collimator to reduce DANTE field of view or eliminating DANTE channels in the analysis have been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The entrance system laboratory prototype for an advanced mass and ionic charge composition experiment

Electrostatic analyzers (ESA) have been used extensively for the characterization of plasmas in a variety of space environments. They vary in shape, geometry, and size and are adapted to the specific particle population to be measured and the configuration of the spacecraft. Their main function is to select the energy per charge of the particles within a passband. An energy-per-charge range larger than that of the passband can be sampled by varying the voltage difference between the ESA electrodes. The voltage sweep takes time and reduces the duty cycle for a particular energy-per-charge passband. Our design approach for an advanced mass and ionic charge composition experiment (AMICCE) has a novel electrostatic analyzer that essentially serves as a spectrograph and selects ions simultaneously over a broad range of energy-per-charge (E/q). Only three voltage settings are required to cover the entire range from {approx}10 to 270 keV/q, thus dramatically increasing the product of the geometric factor times the duty cycle when compared with other instruments. In this paper, we describe the AMICCE concept with particular emphasis on the prototype of the entrance system (ESA and collimator), which we designed, developed, and tested. We also present comparisons of the laboratory results with electrostatic simulations.

42 ENGINEERING↗

Simulation and Characterization of the MINER{nu}A Dipole Magnets

The MINER{nu}A (Main INjector ExpeRiment for {nu} A) experiment (http://minerva.fnal.gov/) is a neutrino scattering experiment which uses the NuMI beamline at Fermilab. It seeks to measure low energy neutrino interactions both to support neutrino oscillation experiments and to study the strong dynamics of the nucleon and nucleus that affect these interactions. For energy calibration of the main detector, a tertiary test beam line was designed and commissioned. This test beam consisted of target, collimator, two TOF stations and four wire chamber stations. Two dipole trim magnets were used to form a spectrometer. Here we present the simulation and characterization of these dipole magnets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present status of SPring-8 macromolecular crystallography beamlines

Seven beamlines are operated for macromolecular crystallography (MX) at SPring-8. The three undulator beamlines are developed for cutting edge target and four bending-magnet beamlines are developed for high throughput MX. The undulator beamline, BL41XU that provides the most brilliant beam, is dedicated to obtain high quality data even from small-size and weakly-diffracting crystals. The minimum beam size at sample position is achieved to 10 {mu}m diameter using a pin-hole collimator. Its photon flux at wavelength {lambda} = 1.0 A is 2.8x10{sup 11} photons/sec. This small beam coupled with irradiation point scanning method is quite useful to take diffraction dataset from small crystals by suppressing the radiation damage. These advanced technologies made a number of difficult protein structure analysis possible, (i.e. Sodium-potassium ATPase). The bending-magnet beamlines BL26B1/B2 and BL38B1 provide automatic data collection exploiting the high mobility of the beam. The beamline operation software 'BSS', sample auto-changer 'SPACE' and web-based data management software 'D-Cha' have made the automatic data collection possible. The 'Mail-in data collection system' that accepts distant users samples via courier service have made users possible to collect diffraction data without visiting SPring-8. The structural genomics research is promoted by these beamlines.

43 PARTICLE ACCELERATORS↗

Development of two-channel prototype ITER vacuum ultraviolet spectrometer with back-illuminated charge-coupled device and microchannel plate detectors

A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Tangential x-ray diagnosis for investigating fast MHD events in EAST tokamak

A tangential x-ray diagnosis has been installed in the experimental advanced superconducting tokamakvacuum vessel for the study of fast magnetohydrodynamics (MHD) events. This system is based on absolute x-ray ultraviolet detectors with a collimator which is processed by laser machine. The first experimental results have proved its ability to measure the small-scale and transient MHD perturbations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and testing of the instrument for neutron holographic study at the Budapest Research Reactor

Neutron scattering device dedicated to neutron holography experiments is described. The device is operating at a constant wavelength prepared by a double focusing monochromator. It is equipped by highly efficient shielding, proper collimator, Eulerian cradle, monitor detector, gamma-ray, and neutron detectors as well. Relevant software serves as control for the measurement and data collection. The harmonized application of the components enumerated above makes our device extremely efficient and unparalleled. Two atomic resolution neutron holographic experiments carried out illustrate the efficiency and power of the instrument.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Facility for 500 MeV Plasma Wake-Field Acceleration Experiments at Budker INP

The experimental PWFA facility currently under construction at the Budker INP is described. The objective is to use electron and positron beams extracted from the VEPP-5 damping ring in PWFA experiments. Due to longitudinal beam compression many PWFA schemes including the efficient blowout regime as well as multibunch regime can be studied. The simulations of beam dynamics in the facility are presented. Also we propose a simple technique for longitudinal beam slicing using dipole kickers and collimator in the damping ring.

43 PARTICLE ACCELERATORS↗

Development of high productivity medium current ion implanter 'EXCEED 3000AH Evo2'

High productivity medium current ion implanter 'EXCEED 3000AH Evo2' is developed. In semiconductor manufacturing field, improvement of the productivity is continuously required. Especially mass production lines recently tend to use low energy beam and 2 pass implant for higher throughput. The 'Evo2' has been developed in an effort to fulfill these requirements. The 'Evo2' increases low energy beam current by 150 to 250% by applying electrostatic einzel lens called 'V-lens' installed at the exit of the Collimator magnet. This lens is also able to control the beam incident angle by adjusting the upper and lower electrode's voltages independently. Besides, mechanical scanning speed is enhanced to minimize process time of 2 pass implant, while also frequency of the fast beam scanning is enhanced to keep dose uniformity. In addition, a vacuum pumping capability at the target chamber is enhanced to reduce a vacuum waiting time during processing photo-resist wafers. This improvement achieved to reduce process time by 40% for a specific recipe. Furthermore, a modified Indirectly Heated Cathode with electron active Reflection 2 (IHC-R2) ion source which has a long life time filament has been installed. These new elements and/or functions have realized typically 25% improvement of productivity compared to standard EXCEED, and also improve a precise implantation capability.

43 PARTICLE ACCELERATORS↗

True Zero Degree Incident Implants on VIISta3000

The deliberate use of channeling to control depth profiles has come of age in the application to CMOS imaging sensor device manufacturing. In order to enable the true zero implant application on VIISta3000, we have optimized beam incidence angle control, using beam optics models and experimental measurements. The experiment measurement and the beam optics analysis results agree, showing a variation of less than 0.03 deg. (1{sigma}) across the wafer and from wafer to wafer. Achieving this accuracy in a manufacturing environment requires careful calibration and tight control of the collimator magnet and the mechanical scan system. In this paper we discuss the root cause of beam incidence angle variation on VIISta3000 and explain the calibration and optimization used to insure the consistent minimized beam incidence angle. We show experimental data, including ThermaWave and SIMS profiles.

43 PARTICLE ACCELERATORS↗

Ion Beam Neutralization Using FEAs and Mirror Magnetic Fields

Advanced implantation systems used for semiconductor processing require transportation of ion beams which are quasi-parallel and have low energy, such as ({sup 11}B{sup +},{sup 31}P{sup +},{sup 75}As{sup +}) with energy in the range E{sub ion} 200-1000 eV. Compensation of ion beam divergence may be obtained through electron injection and confinement in regions of non-uniform magnetic fields. Field emitter arrays with special properties are used as electron sources. The present study shows that electron confinement takes place in regions of gradient magnetic field, such as nearby analyzing, collimator and final energy magnets of the ion beam line. Modeling results have been obtained using Opera3D/Tosca/Scala. In regions of gradient magnetic field, electrons have helical trajectories which are confined like a cloud inside curved 'magnetic bottles'. An optimal range of positions with respect to the magnet for placing electron sources in gradient magnetic field has been shown to exist.

43 PARTICLE ACCELERATORS↗

Resonant excitation of coherent Cerenkov radiation in dielectric lined waveguides

We report the observation of coherent Cerenkov radiation in the terahertz regime emitted by a relativistic electron pulse train passing through a dielectric lined cylindrical waveguide. We describe the beam manipulations and measurements involved in repetitive pulse train creation including comb collimation and nonlinear optics corrections. With this technique, modes beyond the fundamental are selectively excited by use of the appropriate frequency train. The spectral characterization of the structure shows preferential excitation of the fundamental and of a higher longitudinal mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploration of ion temperature profile measurements at JET using the upgraded neutron profile monitor

The neutron profile monitor (NPM), routinely used at the Joint European Torus for neutron emissivity profile measurements, consists of two fan-shaped arrays of collimators and each line of sight (LOS) is equipped with a NE213 liquid organic scintillator for simultaneous measurements of the 2.5 MeV and 14 MeV neutrons. A digital system developed in ENEA has replaced the analog acquisition electronics and now enables the NPM to perform spatially resolved neutron spectrometry by providing neutron pulse height spectra (PHS) for each LOS. However, the NPM was not originally designed as a spectrometer and, therefore, lacks several key features, such as detailed measurements of the detector response functions and the presence of detector stability monitors. We present a proof of principle of ion temperature profile measurements derived from the NPM PHS in high plasma current discharges using simulated detector response functions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First fusion proton measurements in TEXTOR plasmas using activation technique

MeV particle loss measurements from fusion plasmas, in particular alpha particles, remain difficult in large fusion devices and further R and D is needed for ITER. This paper describes the first attempt to measure 3 MeV escaping fusion protons emitted from TEXTOR tokamak plasmas using activation technique. This technique was successfully demonstrated, initially, in 2006 on the JET tokamak. An ion camera equipped with a collimator and several types of activation detectors was installed inside the TEXTOR vacuum vessel to perform these measurements. After irradiation, the detectors were analyzed using ultra low level gamma-ray spectrometry at the HADES underground laboratory. 3 MeV escaping fusion protons were detected in larger number -{approx}6 times more - compared to earlier measurements using this technique on JET. Another major progress was the reduction of the cooling time by a factor of 50, which made possible to detect radionuclides with half-life of less than 90 min.