Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Control Co-Design Framework for Joint Optimization of PID Governor and Hydraulic Dynamics for a Hydropower Plant

This paper presents a control co-design (CCD) framework tailored to the hydraulic and mechanical subsystems of hydropower systems, aimed at enhancing their dynamic performance and responsiveness to grid demands. Conventional sequential design approaches often fall short in capturing the coupled interactions between plant dynamics and control objectives. The proposed CCD methodology enables simultaneous optimization of key hydro plant parameters - such as governor settings, penstock characteristics, and valve control - with the control system architecture. Results indicate that both CCD and sequential design approaches achieve comparable transient and steady-state performance, with minor discrepancies arising from differences in their optimized parameters. However, CCD demonstrates a distinct advantage by tripling the water time constant (Tw) while maintaining similar dynamic performance to the sequential approach. This increase in Tw enables optimization of penstock dimensions, as it is directly influenced by penstock design, thereby contributing to overall cost optimization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive Large-Eddy Simulation of Supercritical-Pressure Reactive Flows in the Cold Ignition Regime

This report describes a one-year study performed under DOE sponsorship, continuing the investigation of high-pressure turbulent reactive flows. The interest is in the effect of the chemical species distribution in high-pressure turbulent flows in the presence of strong temperature gradients as would occur during reactions in realistic flows. The prime example of such flows are boundary layers in which the wall is at a lower temperature than that of the fluid, as would be the case in Diesel engines. Previous DOE BES work in the program further highlighted the importance of the boundary layer as a configuration for fundamental studies: soot formation in boundary layers is still a problem poorly understood and depends on the availability of particular chemical species at that location, and when boundary layer Large Eddy Simulations results were compared with measurements, the agreement was unfavorable, showing that this important ‘unit’ problem is not well understood. To understand this unit problem, modeling and Direct Numerical Simulations of this unit problem were conducted for the simplest possible multispecies system, that is a binary-species system. The results discovered a new phenomenon, that is, Soret effect induced uphill diffusion. The far-reaching implication is that through an imposed wall/fluid temperature difference it is possible to control the distribution of the species in the boundary layer. Because the results have been documented in one paper published in the refereed literature, and also in conference papers, this final report is in the form of an Executive Summary succinctly describing the results and putting them in perspective with respect to existing information. The refereed and conference papers published are individually listed as Appendices and attached to this report. One manuscript is still in progress and is thus not listed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Role of Dynamic Polarization Interactions in the Electrical Double Layer at Calcite (104) Interfaces with Aqueous Solutions

Reactions at mineral interfaces with aqueous solutions control many geochemical and biogeochemical processes in the Earth’s critical zone. At the molecular level, insights into important properties such as the structure of the electrical double layer (EDL) at specific mineral interfaces continue to improve due to the increasing fidelity of laboratory instrumentation and computational approaches. However, molecular simulation approaches suffer from limited reach into relevant scales of time, length, and system complexity. To span this gap, a novel hybrid approach that couples first principle plane-wave density functional theory (DFT) with classical DFT (cDFT) is demonstrated and applied to calcite (104) interfaces with various electrolytes. In this approach, a region of interest described using DFT interacts with the surrounding medium described using cDFT to arrive at a self-consistent ground state. Benchmarking against experimental observations and entirely first principle DFT simulations demonstrates that this hybrid model efficiently encompasses the key short-range and collective interactions in the EDL. Simulations of calcite (104)/solution interfaces reveal the key static and dynamic polarization interactions that give rise to structuring of ions and water. Ion hydration interactions have the strongest effect on the depth of the first minimum in the density distribution of counterions at the surface, and the position and width of the first density peak is largely determined by the strength of ion-correlation forces. Finer details of ion distributions are controlled by mutual polarization of the calcite surface and interfacial electrolyte. Finally, this new ability to efficiently and rigorously predict EDL structure at mineral surfaces in contact with complex solutions paves the way to accurately modeling sorption, nucleation, dissolution, and growth in realistic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Covalent Triazine Framework-Derived Membranes: Engineered Sol–Gel Construction and Gas Separation Application

Covalent triazine frameworks (CTFs) represent one of the most extensively studied organic networks characterized by graphitic π-conjugated structures linked by aza-fused rings, possessing unique features such as compositions of light elements (e.g., C, H, and N), porous architectures abundant heteroatom involvement, and extensively conjugated structures. In addition, the textural and chemical structures of CTFs could be engineered via synthesis control to accommodate diverse applications. CTF materials with notable characteristics, including plentiful (ultra-)micropores, high surface areas, and the presence of CO 2 -philic functional groups involving nitrogen (N), oxygen (O), and fluorine (F), hold great promise as potential candidates for anthropogenic CO 2 capture and sequestration (CCS) applications. However, the conventional high-temperature involved ionothermal procedures and the solution-based coupling pathway only afforded CTF materials in powder form, which is difficult to be processed toward membrane formation. Successful fabrication of CTF-derived membranes will rely on the development of alternative polymerization approaches as well as structural engineering to afford membrane architectures with controllable porosity distribution and active interaction sites with CO 2 benefiting the CO 2 separation procedure. In this Account, a demonstration of the latest progress in the development of CTF-derived membranes was provided. The CTF membranes were mainly synthesized via a superacid (e.g., CF 3 SO 3 H)-promoted sol–gel approach involving the polymerization of aromatic nitrile monomers. The formation of the triazine unit through the trimerization of cyano groups served as the cross-linkers, resulting in the creation of π-conjugated networks alongside the arenes present in the starting materials. The aromatic nitrile monomers with rigid and sterically hindered structures were required to afford CTF membranes with nanoporous architectures. The acidity of the superacid and reactivity of the aromatic monomers played critical roles in the polymerization efficiency. The monomer diversity and synthesis tunability endowed the introduction of CO 2 -philic functionalities (e.g., pyrazole and fluorine) within the CTF skeletons, and integration of ionic moieties was achieved by adopting FSO 3 H with stronger acidity as the catalyst and aromatic nitrile monomers with pyrazine structures. To ensure the successful construction of fluorinated CTF membranes, it is important to avoid any fluorines on the ortho-position of the cyano groups on the benzene ring. Through control over the monomers and reaction conditions, flexible, transparent, and insoluble CTF membranes could be fabricated. The sol–gel method could be further expanded to membrane fabrication through acetyl-to-benzene transformation through synthesis control. The mild oxidation-exfoliation-filtration method was also demonstrated to fabricate substrate-supported CTF membranes. The as-afforded membranes are well characterized to determine the structural features and provide information to study the structure-performance relationship. Here, the application of CTF membranes in CO 2 separation was summarized, focusing on the approaches being developed to enhance CO 2 uptake and separation performance. In addition to utilizing the pristine CTF membranes for gas separation, functionalized carbon molecular sieve membranes could be obtained from the pyrolysis of thermally stable CTF membrane precursors toward efficient CO 2 separation, benefiting from the abundant ultramicropores being created during the pyrolysis/decomposition procedure and involvement of CO 2 -philic functionalities such as fluorine and nitrogen-containing moieties. Based on these achievements, unsolved issues in CTF membrane-related fabrication and applications, including the potential solution approaches, have been proposed to advance the application of CTF membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of a Publish-Subscribe Protocol in Microgrid Islanding and Resynchronization with Self-Discovery

Communications systems and protocols are becoming second nature to utilities operating distribution systems. Traditionally, centralized communication approaches are often used, while recently in microgrid applications, distributed communication and control schema emerge offering several advantages such as improved system reliability, plug-and-play operation and distributed intelligence. Still, operation and control of microgrids including distributed communication schema have been less of a discussion in the literature. To address the challenge of multiple-inverter microgrid synchronization, a publish-subscribe protocol based, Data Distribution Service (DDS), communication schema for microgrids is proposed in this paper. The communication schema is discussed in details for individual devices such as generators, photovoltaic systems, energy storage systems, microgrid point of common coupling switch, and supporting applications. In conclusion, islanding and resynchronization of a microgrid are demonstrated on a test-bed utilizing this schema.

25 ENERGY STORAGE↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

Coverage Dependent Charge Reduction of Cationic Gold Clusters on Surfaces Prepared Using Soft Landing of Mass-selected Ions

The ionic charge state of monodisperse cationic gold clusters on surfaces may be controlled by selecting the coverage of mass-selected ions soft landed onto a substrate. Polydisperse diphosphine-capped gold clusters were synthesized in solution by reduction of chloro(triphenylphosphine)gold(I) with borane tert-butylamine in the presence of 1,3-bis(diphenylphosphino)propane. The polydisperse gold clusters were introduced into the gas phase by electrospray ionization and mass selection was employed to select a multiply charged cationic cluster species (Au11L53+, m/z = 1409, L = 1,3-bis(diphenylphosphino)propane) which was delivered to the surfaces of four different self-assembled monolayers on gold (SAMs) at coverages of 1011 and 1012 clusters/mm2. Employing the spatial profiling capabilities of in-situ time-of-flight secondary ion mass spectrometry (TOF-SIMS) it is shown that, in addition to the chemical functionality of the monolayer (as demonstrated previously: ACS Nano, 2012, 6, 573) the coverage of cationic gold clusters on the surface may be used to control the distribution of ionic charge states of the soft-landed multiply charged clusters. In the case of a 1H,1H,2H,2H-perfluorodecanethiol SAM (FSAM) almost complete retention of charge by the deposited Au11L53+ clusters was observed at a lower coverage of 1011 clusters/mm2. In contrast, at a higher coverage of 1012 clusters/mm2, pronounced reduction of charge to Au11L52+ and Au11L5+ was observed on the FSAM. When soft landed onto 16- and 11-mercaptohexadecanoic acid surfaces on gold (16,11-COOH-SAMs), the mass-selected Au11L53+ clusters exhibited partial reduction of charge to Au11L52+ at lower coverage and additional reduction of charge to both Au11L52+ and Au11L5+ at higher coverage. The reduction of charge was found to be more pronounced on the surface of the shorter (thinner) C11 than the longer (thicker) C16-COOH-SAM. On the surface of the 1-dodecanethiol (HSAM) monolayer, the most abundant charge state was found to be Au11L52+ at lower coverage and Au11L5+ at higher coverage, respectively. A coverage-dependent electron tunneling mechanism is proposed to account for the observed reduction of charge of mass-selected multiply charged gold clusters soft landed on SAMs. The results demonstrate that one of the critical parameters that influence the chemical and physical properties of supported metal clusters, ionic charge state, may be controlled by selecting the coverage of charged species soft landed onto surfaces.

charge reductionkk↗

Estimation of Behind-the-Meter Solar Generation by Integrating Physical with Statistical Models

Accurate estimation of solar photovoltaic (PV) generation is crucial for distribution grid control and optimization. Unfortunately, most of the residential solar PV installations are behind-the-meter. Thus, utilities only have access to the net load readings. This paper presents an unsupervised framework for estimating solar PV generation by disaggregating the net load readings. The proposed framework synergistically combines a physical PV system performance model with a statistical model for load estimation. Specifically, our algorithm iteratively estimates solar PV generation with a physical model and electric load with the Hidden Markov model regression. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is validated against net load and solar PV generation data gathered from residential customers located in Austin, Texas. The validation results show that our method reduces mean squared error by 44% compared to the state-of-the-art disaggregation algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Differential Power Processing for Ultra-Efficient Data Storage

Here this paper presents the hardware, software, and power codesign of an ultra-efficient data storage server with differential power processing (DPP). DPP can reduce the power conversion stress, improve the efficiency, and enhance the functionality of modular power electronics systems. The power inputs of a large number of hard disk drives (HDDs) were connected in series and supported by a multiport ac-coupled differential power processing (MAC-DPP) converter through a multiwinding transformer. Methods for controlling the multi-input multi-output power flow in the multiwinding transformer while avoiding core saturation were investigated. A ten-port MAC-DPP prototype with 700-W/in 3 power density was built to support a 450-W HDD storage system with ten series-stacked voltage domains. The prototype was tested on a 50-HDD server testbench, and the overall system loss is below 1 W (99.77% system efficiency). The server was able to maintain high-speed reading and writing operation of all 50 HDDs against the worst hot-swapping scenarios. A variety of hardware/software configurations and many cloud storage techniques were tested on the fully functioning server. Experimental results show that the energy efficiency of large-scale information systems (CPU/GPU clusters, memory banks, HDD arrays, etc.) can be greatly improved by software, hardware, and power codesign.

42 ENGINEERING↗

Cyber Attack Resilient HVDC System (CARDS) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE-OE funded project DE-OE0000824, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), Argonne National Laboratories (ANL), and University of Idaho (UI) pursued the development of a system of defense for High Voltage Direct Current transmission systems against cyber-attacks (CARDS). An HVDC substation with CARDS features will be more capable of mitigating cyber-attacks especially those that seek to control or interrupt the power flow in the HVDC line. It empowers existing HVDC intelligent electronic devices to collaborate in identifying and blocking malicious intents to trip HVDC AC circuit breakers, block thyristor valves, misconfigure devices settings, even though the commands and the measurements comply with correct syntax. The CARDS functions utilize the physics of electromagnetic AC and DC systems, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected HVDC substation devices. With the aim of advancing the state of the art, the team proceeded to develop a demonstrable system against cyber-attacks in an HVDC substation environment, via functional upgrades to existing firmware of commercial off-the-shelf HVDC station devices, and/or embedded hardware, without the need for additional instrumentation nor new instrumentation technologies. It is to ensure that the solutions resulting from the project will support the HVDC devices currently installed in the US electricity delivery infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Transients in District Heating Systems

Heat fluxes in a district heating pipeline systems need to be controlled on the scale from minutes to an hour to adjust to evolving demand. There are two principal ways to control the heat flux - keep temperature fixed but adjust velocity of the carrier (typically water) or keep the velocity flow steady but then adjust temperature at the heat producing source (heat plant). Here, we study the latter scenario, commonly used for operations in Russia and Nordic countries, and analyze dynamics of the heat front as it propagates through the system. Steady velocity flows in the district heating pipelines are typically turbulent and incompressible. Changes in the heat, on either consumption or production sides, lead to slow transients which last from tens of minutes to hours. We classify relevant physical phenomena in a single pipe, e.g. turbulent spread of the turbulent front. We then explain how to describe dynamics of temperature and heat flux evolution over a network efficiently and illustrate the network solution on a simple example involving one producer and one consumer of heat connected by “hot” and “cold” pipes. We conclude the manuscript motivating future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UNIFI's Grid-Forming (GFM) Inverter Reference Design: A Tutorial on Modeling, Control, and Experimental Implementation of GFM Inverters

The UNIFI Consortium's tutorial on grid-forming (GFM) inverters provides a comprehensive guide to the modeling, control, and experimental implementation of GFM inverters. As the integration of renewable energy accelerates, the transition from traditional grid following (GFL) to GFM inverters is crucial to ensure stable and sustainable power systems. This document outlines a reference design for three-phase and single-phase GFM inverters developed at the University of Texas at Austin. The tutorial also provides step-by-step guidance for accessing and using UNIFI’s GitHub repository, enabling users to design, build, and test GFM inverters efficiently. By fostering collaboration and equipping users with accessible resources, this initiative aims to drive widespread adoption of GFM technology across academia, utilities, and industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Survey of Cybersecurity Governance, Threats, and Countermeasures for the Power Grid

The convergence of Information Technologies and Operational Technology systems in industrial networks presents many challenges related to availability, integrity, and confidentiality. In this paper, we evaluate the various cybersecurity risks in industrial control systems and how they may affect these areas of concern, with a particular focus on energy-sector Operational Technology systems. There are multiple threats and countermeasures that Operational Technology and Information Technology systems share. Since Information Technology cybersecurity is a relatively mature field, this paper emphasizes on threats with particular applicability to Operational Technology and their respective countermeasures. We identify regulations, standards, frameworks and typical system architectures associated with this domain. We review relevant challenges, threats, and countermeasures, as well as critical differences in priorities between Information and Operational Technology cybersecurity efforts and implications. These results are then examined against the recommended National Institute of Standards and Technology framework for gap analysis to provide a complete approach to energy sector cybersecurity. We provide analysis of countermeasure implementation to align with the continuous functions recommended for a sound cybersecurity framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real-Time Distribution Feeder Performance Monitoring, Advisory Control, and Health Management System

New data collection system equipment was installed in Xcel Energy substations and data was collected from 6 substations and 20 feeders. During Phase I, ABB collected and analyzed 793 real-time events to date from 6 Xcel Energy substations and continues today. The development and integration of several applications was completed during the course of this project, including a model-based faulted segment identification algorithm, with very positive results validated with field-gathered data discussed and included in this report. For mostly underground feeders, the success rate is 90% and the overreach rate is 90%. For mostly overhead feeders, the success rate is 74% and the overreach rate is 50%. The developed method is producing very accurate results for mostly underground feeders. For mostly overhead feeders, due to the bad OMS data quality and varying fault resistance when arcing, the developed method is producing good results but with much room for improvement. One area where the algorithm can be improved is the accuracy for sub-cycle fault events. In these cases, the accuracy of the conventional signal processing methods suffers due to most of these methods being based on a one-cycle processing window. By improving the signal processing accuracy, the accuracy of the faulted segment identification algorithm will also improve significantly. ABB intends to devote research in this area in the near future to help solve this problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Towards a State Based Control Architecture for Large Telescopes: Laying a Foundation at the VLT

Large telescopes are characterized by a high level of distribution of control-related tasks and will feature diverse data flow patterns and large ranges of sampling frequencies; there will often be no single, fixed server-client relationship between the control tasks. the architecture is also challenged by the task of integrating heterogeneous subsystems which will be delivered by multiple different contractors. Due to the high number of distributed components, the control system needs to effectively detect errors and faults, impede their propagation, and accurately mitigate them in the shortest time possible, enabling the service to be restored. The presented Data-Driven Architecture is based on a decentralized approach with an end-to-end integration of disparate, independently developed software components. These components employ a high-performance standards-based communication middle-ware infrastructure, based on the Data Distribution Service. A set of rules and principles, based on JPL's State Analysis method and architecture, are use to constrain component-to component interactions, where the Control System and System Under Control are clearly separated. State Analysis provide a model-based process for capturing system and software requirements and design, greatly reducing the gap between the requirements on software specified by systems engineers and the implementation by software engineers. The method and architecture has been field tested at the Very Large Telescope, where it has been integrated into an operational system.

European Extremely Large Telescope (E-ELT)↗

SU-E-T-454: Impact of Calculation Grid Size On Dosimetry and Radiobiological Parameters for Head and Neck IMRT

Purpose: IMRT has become standard of care for complex treatments to optimize dose to target and spare normal tissues. However, the impact of calculation grid size is not widely known especially dose distribution, tumor control probability (TCP) and normal tissue complication probability (NTCP) which is investigated in this study. Methods: Ten head and neck IMRT patients treated with 6 MV photons were chosen for this study. Using Eclipse TPS, treatment plans were generated for different grid sizes in the range 1–5 mm for the same optimization criterion with specific dose-volume constraints. The dose volume histogram (DVH) was calculated for all IMRT plans and dosimetric data were compared. ICRU-83 dose points such as D2%, D50%, D98%, as well as the homogeneity and conformity indices (HI, CI) were calculated. In addition, TCP and NTCP were calculated from DVH data. Results: The PTV mean dose and TCP decreases with increasing grid size with an average decrease in mean dose by 2% and TCP by 3% respectively. Increasing grid size from 1–5 mm grid size, the average mean dose and NTCP for left parotid was increased by 6.0% and 8.0% respectively. Similar patterns were observed for other OARs such as cochlea, parotids and spinal cord. The HI increases up to 60% and CI decreases on average by 3.5% between 1 and 5 mm grid that resulted in decreased TCP and increased NTCP values. The number of points meeting the gamma criteria of ±3% dose difference and ±3mm DTA was higher with a 1 mm on average (97.2%) than with a 5 mm grid (91.3%). Conclusion: A smaller calculation grid provides superior dosimetry with improved TCP and reduced NTCP values. The effect is more pronounced for smaller OARs. Thus, the smallest possible grid size should be used for accurate dose calculation especially in H and N planning.

60 APPLIED LIFE SCIENCES↗

Tools for Enhanced Grid Operation and Optimized PV Penetration Utilizing Highly Distributed Sensor Data.

Increasing number s of PV on distribution systems are creating more grid impacts , but it also provides more opportunities for measurement, sensing, and control of the grid in a distributed fashion. This report demonstrates three software tools for characterizing and controlling distribution feeders by utilizing large numbers of highly distributed current, voltage , and irradiance sensors. Instructions and a user manual is presented for each tool. First, the tool for distribution system secondary circuit parameter estimation is presented. This tool allows studying distribution system parameter estimation accuracy with user-selected active power, reactive power, and voltage measurements and measurement error levels. Second, the tool for multi-objective inverter control is shown. Various PV inverter control strategies can be selected to objectively compare their impact on the feeder. Third, the tool for energy storage for PV ramp rate smoothing is presented. The tool allows the user to select different storage characteristics (power and energy ratings) and control types (local vs. centralized) to study the tradeoffs between state-of-charge (SOC) management and the amount of ramp rate smoothing.

Reno, Matthew J.↗

Standard Library Plant Controller Model Specification for a Grid-Forming Hybrid Control Inverter-Based Resource (REPCGFM_C1)

This document describes a standard library plant controller model to interface with the grid-forming hybrid control inverter-based resource (IBR) model. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control algorithms to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗