Design of and data reduction from compact Thomson parabola spectrometers

Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithm-Based Fault Tolerance for Convolutional Neural Networks

Convolutional neural networks (CNNs) are becoming more and more important for solving challenging and critical problems in many fields. CNN inference applications have been deployed in safety-critical systems, which may suffer from soft errors caused by high-energy particles, high temperature, or abnormal voltage. Of critical importance is ensuring the stability of the CNN inference process against soft errors. Traditional fault tolerance methods are not suitable for CNN inference because error-correcting code is unable to protect computational components, instruction duplication techniques incur high overhead, and existing algorithm-based fault tolerance (ABFT) techniques cannot protect all convolution implementations. In this paper, we focus on how to protect the CNN inference process against soft errors as efficiently as possible, with the following three contributions. (1) We propose several systematic ABFT schemes based on checksum techniques and analyze their fault protection ability and runtime thoroughly. Unlike traditional ABFT based on matrix-matrix multiplication, our schemes support any convolution implementations. (2) We design a novel workflow integrating all the proposed schemes to obtain a high detection/correction ability with limited total runtime overhead. (3) We perform our evaluation using ImageNet with well-known CNN models including AlexNet, VGG-19, ResNet-18, and YOLOv2. Here, experimental results demonstrate that our implementation can handle soft errors with very limited runtime overhead (4%~8% in both error-free and error-injected situations).

97 MATHEMATICS AND COMPUTING↗

Uncertainty quantification of a physics-informed model based on sparse identification of a Thermal Energy Distribution System

Integrated energy systems (IES)s are crucial for enhancing the economy and efficiency of power generation sources (e.g., nuclear energy) necessary to unleash American energy dominance. These systems can be integrated with thermal energy storage (TES) and intermittent renewable energies to optimize overall energy use, peak-load regulation, and demand-side responses. However, the stabilization of energy generation, transport, and utilization introduces operational complexities that exceed the challenges of managing each sub-component individually. Currently, though IESs rely on human operators for efficiency and stability, reducing human error risk and enhancing performance through automation is highly desirable. Recent advances at Idaho National Laboratory have demonstrated successful control of the Thermal Energy Distributed System (TEDS). However, the automatic control system depends on a deterministic Sparse Identification of Nonlinear Dynamics with Control (SINDyC) model, which are trained based on simulation data from physics-based simulations. Because of uncertainties in physics-based simulation, SINDyC model results in large discrepancies against experimental data and cannot be reliably used in automatic control. In this paper, we present an innovative approach to address these discrepancies by quantifying uncertainties and developing a more robust model. We first generated trajectories by using first-principles physics codes to encapsulate the experiment. Next, we trained thousands of models by randomly sampling these trajectories. We then collapsed all those models into one probabilistic SINDyC by fitting a multivariate Gaussian distribution onto the resulting coefficient’s distribution. Despite its simplicity, our approach successfully produced 95% confidence intervals that captured the experimental trajectories. It even did so with a higher probability and better U-pooling score across six of the seven relevant quantities of interest (QoIs), as compared to other classical approaches. In conclusion, ongoing research is focusing on generating new experimental trajectories to validate this approach, and on employing Bayesian calibration to refine parametric uncertainties and guide future model development efforts.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine learning based unfolding of x-ray spectra from filter stack spectrometer data

We demonstrate the application of neural networks to perform x-ray spectra unfolding from data collected by filter stack spectrometers. A filter stack spectrometer consists of a series of filter-detector pairs, where the detectors behind each filter measure the energy deposition through each layer as photo-stimulated luminescence (PSL). The network is trained on synthetic data, assuming x-rays of energies < 1 MeV and of two different distribution functions (Maxwellian and Gaussian) and the corresponding measured PSL values obtained from five different filter stack spectrometer designs. Predicted unfolds of single distributions are near identical reproductions of the ground truth spectra, with differences in the values lower than 20% at the higher energy end in some cases. The neural network has also demonstrated robustness to experimental measurement errors of < 5% and some capability of performing unfolds for linear combinations of the two distributions without previous training. The network can perform unfolds at rates > 1 Hz, ideal for application to some high-repetition-rate systems.

47 OTHER INSTRUMENTATION↗

Data Evaluation of Actinide Cross Sections: 240 Am, 241 Am, and 242 Am

Evaluations for neutron-induced reactions on the isotopes 240 Am, 241 Am, and 242 Am were per formed by optimizing reaction-model calculations based on existing experimental data from both direct measurements and surrogate reactions. The evaluated data were based on results obtained from the LLNL reaction codes YAHFC and FRESCO using up-to-date nuclear models; including an improvement upon some previous treatments for inelastic processes. Nuclear reaction codes generated data for all relevant reaction channels, which were then translated into Generalized Nu clear Data Structure and LLNL’s Evaluated Neutron Data Libraries (ENDL). These data libraries were tested for potential errors and applied to verification and validation (V&V) tests suites where applicable for comparisons.

42 ENGINEERING↗

Experimental implementation of adaptive control for flexible space structures

On-going research at The Aerospace Corporation studying the feasibility of applying adaptive control methodologies to the control of flexible space structures is described. A laboratory testbed was established to test system identification and control approaches. The laboratory set-up and controller design approach are discussed. The ARX least squares parameter estimation technique is analyzed in terms of frequency domain transfer function bias error. This analysis approach enables the determination of the effects of sampling rate, sensor type, and data prefiltering on the estimation performance. The ability to identify space structure dynamics over a range of frequencies is shown to be heavily dependent on these factors.

Mcgraw, Gary A.↗

Characterizing particle-scale equilibrium adsorption and kinetics of uranium(VI) desorption from U-contaminated sediments

Rates of contaminant U(VI) release from individual size fractions of a composite sediment from the seasonally saturated lower vadose zone of the Hanford 300-Area were examined in flow-through batch reactors to maintain quasi-constant chemical conditions. Variability in equilibrium adsorption among the various size fractions was determined in static batch reactors and analyzed using the surface complexation modeling approach. The estimated stoichiometric coefficients of U(VI) surface complexation reactions with respect to pH and carbonate concentrations varied with size fractions. This source of variability significantly increased the uncertainty in U(VI) conditional equilibrium constants over that estimated from experimental errors alone. A minimum difference between conditional equilibrium constants was established in order to evaluate statistically significant differences between sediment adsorption properties. A set of equilibrium and kinetic expressions for cation exchange, calcite dissolution, aerobic respiration, and silica dissolution were incorporated in a reaction-rate model to describe the temporal evolution of solute concentrations observed during the flow-through batch experiments. Parameters in the reaction-rate model, calibrated using experimental data for select size fractions, predicted the changes in solute concentrations for the bulk, <2 mm, sediment sample. Kinetic U(VI) desorption was well described using a multi-rate surface complexation model with an assumed lognormal distribution for the rate constants. The estimated mean and standard deviation were the same for all < 2mm size fractions, but differed in the 2-8mm size fraction. Micropore volumes in the varied size fractions were also similar as assessed using t-plots to analyze N2 desorption data. These findings provide further support for the link between microporosity and particle-scale mass transfer rates controlling kinetic U(VI) adsorption/desorption and for the utility of N2 desorption isotherms for characterizing pore networks that influence mass transfer rates.

Stoliker, Deborah L.↗

A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation, and radiochromic film

This study aimed to investigate the high-dose rate Iridium-192 brachytherapy, including near source dosimetry, of a catheter-based applicator from 0.5 mm to 1 cm along the transverse axis. Radiochromic film and Monte Carlo (MC) simulation were used to generate absolute dose for the catheter-based applicator. Results from radiochromic film and MC simulation were compared directly to the treatment planning system (TPS) based on the American Association of Physicists in Medicine Updated Task Group 43 (TG-43U1) dose calculation formalism. The difference between dose measured using radiochromic film along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 24%±13%. The dose difference between the MC simulation along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 22.1%±3%. For distances from 1.5 mm to 1 cm from the surface, radiochromic film and MC simulation agreed with TPS within an uncertainty of 3%. The TPS under-predicts the dose at the surface of the applicator, i.e., 0.5 mm from the catheter surface, as compared to the measured and MC simulation predicted dose. MC simulation results demonstrated that 15% of this error is due to neglecting the beta particles and discrete electrons emanating from the sources and not considered by the TPS, and 7% of the difference was due to the photon alone, potentially due to the differences in MC dose modeling, photon spectrum, scoring techniques, and effect of the presence of the catheter and the air gap. Beyond 1 mm from the surface, the TPS dose algorithm agrees with the experimental and MC data within 3%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Non-Invasive Electrode Impedance Estimation for Optimized Charge Profile Parameterization of Lithium-Ion Batteries

This work presents a non-invasive method for parameterizing a physically motivated equivalent circuit model of lithium-ion batteries using operando electrochemical impedance spectroscopy and time-domain data. The proposed model consists exclusively of linear circuit elements, enabling computationally efficient simulation and real-time implementation on battery management system chips. By integrating frequency- and time-domain measurements, the model accurately estimates internal states such as the negative electrode potential, achieving a root mean square error of 12.3 mV during fast charging validation. Parameterization requires only rate tests with sinusoidal perturbations at three different ambient temperatures, making the approach experimentally accessible. The model reveals key insights into battery behavior, including rate-dependent overpotentials primarily governed by charge transfer kinetics at the positive electrode, and temperature-dependent impedance contributions from both charge transfer and solid-state diffusion processes. Validation using reference electrodes confirms the model’s ability to detect lithium plating onset and reproduce impedance behavior across a wide range of operating conditions. The approach enables in situ optimization of fast charging profiles and lays the foundation for future extensions incorporating aging effects and plating dynamics.

25 ENERGY STORAGE↗

Exploring 2D X-ray diffraction phase fraction analysis with convolutional neural networks: Insights from kinematic-diffraction simulations

Abstract Deep-learning models are effective for analyzing the complex information in 2D X-ray diffraction (XRD) patterns. Accurately collecting parameters of the material sample is crucial during model training, significantly impacting model performance. In this study, we employ a kinematic-diffraction simulator to generate simulated 2D XRD patterns for Ti–6Al–4V alloy, allowing precise control of sample parameters. These simulated patterns are used to train convolutional neural networks, predicting $$\upbeta$$ β -phase volume fractions. The training data set consists exclusively of 2D XRD patterns with pure $$\upalpha$$ α - or pure $$\upbeta$$ β -phase, while the testing set incorporates patterns with intermediate phase volume fraction. In particular, we investigate how the architectures of the model influence prediction reliability and computational performance. Experimental results reveal that, with appropriate training, the convolutional neural network accurately detects intermediate phase volume fractions even trained with only pure-phase patterns, achieving a mean square error accuracy of $$9.4 \times 10^{-4}$$ 9.4 × 10 - 4 . Graphical abstract

Yue, Weiqi↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prediction of helicopter rotor discrete frequency noise: A computer program incorporating realistic blade motions and advanced acoustic formulation

A computer program has been developed at the Langley Research Center to predict the discrete frequency noise of conventional and advanced helicopter rotors. The program, called WOPWOP, uses the most advanced subsonic formulation of Farassat that is less sensitive to errors and is valid for nearly all helicopter rotor geometries and flight conditions. A brief derivation of the acoustic formulation is presented along with a discussion of the numerical implementation of the formulation. The computer program uses realistic helicopter blade motion and aerodynamic loadings, input by the user, for noise calculation in the time domain. A detailed definition of all the input variables, default values, and output data is included. A comparison with experimental data shows good agreement between prediction and experiment; however, accurate aerodynamic loading is needed.

Brentner, K. S.↗

Kinetics of the Cl(2)P(J)) + CH4 Reaction: Effects of Secondary Chemistry Below 300 K

Absolute rate data for the Cl(2)P(J) + CH4 yields HCl + CH3 reaction have been obtained from 218 to 298 K by using the discharge-flow resonance fluorescence technique at I Torr total pressure. The result at 298 K is (10.1 +/- 0.6) x 10(exp -14) cu cm/molecule/s. The temperature dependence in Arrhenius form is (6.5 +/- 0.9 ) x 10(exp -12) exp[(-1235 +/- 34 )/T]. The errors given are one standard deviation; overall experimental error is estimated at +/- 15%. Because of the relatively large disagreement among earlier measurements at low temperatures, the results were examined for possible effects of non-Boltzmann spin distribution and vibrational excitation of CH4, secondary chemistry of CH3 radicals, and impurities in the CH4 source. There was no significant change in the observed rate constant when an efficient spin quencher, CF4, was added and estimates indicate that vibrational partitioning in CH4 should be at the ambient reactor temperature before the start of the reaction. The results were also independent of the source of Cl atoms (microwave discharge or thermal decomposition of Cl2) and whether CH4 was purified in-situ. However, the observed rate constant did depend on initial Cl atom concentrations and to a lesser extent on CH4 concentrations. Numerical simulations were used to assess the importance of secondary chemistry over a range of reactant concentrations

Wang, J. J.↗

Visual End-Effector Position Error Compensation for Planetary Robotics

This paper describes a vision-guided manipulation algorithm that improves arm end-effector positioning to subpixel accuracy and meets the highly restrictive imaging and computational constraints of a planetary robotic flight system. Analytical, simulation-based, and experimental analyses of the algorithm's effectiveness and sensitivity to camera and arm model error is presented along with results on several prototype research systems and 'ground-in-the-loop' technology experiments on the Mars Exploration Rover (MER) vehicles. A computationally efficient and robust subpixel end-effector fiducial detector that is instrumental to the algorithm's ability to achieve high accuracy is also described along with its validation results on MER data.

vision-guided manipulation algorithm↗

Trajectory Reconstruction and Uncertainty Analysis Using Mars Science Laboratory Pre-Flight Scale Model Aeroballistic Testing

As part of the Mars Science Laboratory (MSL) trajectory reconstruction effort at NASA Langley Research Center, free-flight aeroballistic experiments of instrumented MSL scale models was conducted at Aberdeen Proving Ground in Maryland. The models carried an inertial measurement unit (IMU) and a flush air data system (FADS) similar to the MSL Entry Atmospheric Data System (MEADS) that provided data types similar to those from the MSL entry. Multiple sources of redundant data were available, including tracking radar and on-board magnetometers. These experimental data enabled the testing and validation of the various tools and methodologies that will be used for MSL trajectory reconstruction. The aerodynamic parameters Mach number, angle of attack, and sideslip angle were estimated using minimum variance with a priori to combine the pressure data and pre-flight computational fluid dynamics (CFD) data. Both linear and non-linear pressure model terms were also estimated for each pressure transducer as a measure of the errors introduced by CFD and transducer calibration. Parameter uncertainties were estimated using a "consider parameters" approach.

Lugo, Rafael A.↗

Visual end-effector position error compensation for planetary robotics

This paper describes a vision-guided manipulation algorithm that improves arm end-effector positioning to subpixel accuracy and meets the highly restrictive imaging and computational constraints of a planetary robotic flight system. Analytical, simulation-based, and experimental analyses of the algorithm's effectiveness and sensitivity to camera and arm model error is presented along with results on several prototype research systems and ground-in-the-loop technology experiments on the Mars Exploration Rover (MER) vehicles. A computationally efficient and robust subpixel end-effector fiducial detector that is instrumental to the algorithm's ability to achieve high accuracy is also described along with its validation results on MER data.

Nickels, Kevin↗

ENDF/B-VIII.0 Augmented Covariance Data: The first iteration

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.