Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Solar mirror soiling and heliostat inspection from a mobile imaging system and mobile platform

A system or method for an imaging system is provided for inspecting a heliostat. The imaging system includes a platform and a camera mounted on the platform and a heliostat having a plurality of mirrored facets. The camera is positioned to acquire a first image that serves as a reference image and a second image that is a reflected image from at least one facet. The camera stores image data associated with the first image and the second image, and wirelessly transmits the stored image data to a computing apparatus. The computing apparatus compares the first image with the second image and determines a performance parameter associated with the heliostat.

Yellowhair, Julius↗

Ghost imaging second harmonic generation microscopy

A system and methods for ghost imaging second harmonic generation microscopy. Imaging data is collected in parallel, providing faster imagine reconstruction and enabling reconstruction in scattering environments. Ghost imaging, split light beam interacting with a target and a second light beam unimpeded and not required to pass through the same background. A second harmonic generation image is reconstructed from the detected photons.

Wiederrecht, Gary P.↗

Imaging grain microstructure in a model ceramic energy material with optically generated coherent acoustic phonons

Characterization of microstructure, chemistry and function of advanced energy materials remains a challenge for instrumentation science with tremendous opportunity for new discoveries. This active area of research is starting to make considerable strides with examples ranging from methodologies that employ bright X-rays, electron microscopy and optical spectroscopy. However, further development of instruments, capable of multimodal measurements, is necessary to fully reveal complex microstructure evolution in realistic environments and dynamical systems that are far from equilibrium. In this regard, laser-based instruments have a unique advantage as multiple measurement methodologies are easily combined into a single instrument using standard optics. A new pump-probe method that uses optically generated acoustic phonons is expanding standard optical characterization by providing depth resolved information. Here we report on a noteworthy extension of this pump-probe method to image grain microstructure in ceria. Rich information regarding the orientation of individual crystallites is obtained by monitoring acoustic phonon velocities and noting how the polarization of the probe beam influences the detected signal amplitude. When paired with other optical microscopies, this methodology will provide new perspectives for optical characterization of ceramic materials.

36 MATERIALS SCIENCE↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Assessing the Need for Preprocedural Laboratory Tests and Stopping Non-steroidal Anti-inflammatory Drugs/Aspirin in Patients Undergoing Percutaneous Bone and Soft Tissue Biopsies

Purpose: Although image-guided biopsies of bone and soft tissue lesions have a low complication rate, there is limited data evaluating use of preprocedural laboratory tests. To address this issue, patients were not required to stop non-steroidal antiinflammatory drugs (NSAIDs) and aspirin or to obtain preprocedural laboratory tests [complete blood count (CBC) and international normalized ratio (INR)], except in special circumstances. The bleeding complication rate, rate of same day biopsies, and the time from when the biopsy was ordered to when it was performed were obtained. Materials and Methods: A total of 332 patients who underwent bone or soft tissue biopsies performed at our institution between 9/1/2017 and 1/9/2019 were prospectively analyzed. These data were compared to a retrospective biopsy cohort of 323 patients between 7/1/2015 and 7/1/2017. Data collected included method of image guidance and bleeding complication rate. The number of days from ordering to performing a biopsy and number of same day biopsies were recorded. Results: There were no bleeding complications in either cohort (OR 1.00, P = 1). The mean time from ordering to performing a bone biopsy was significantly decreased in the prospective group (6.6 days) compared to the retrospective group (8.1 days) (P = 0.012). There were more same day biopsies in the prospective cohort (11.4% vs. 3.4%) (P < 0.001). Conclusions: Preprocedural CBC and INR for bone and soft tissue biopsies can be safely eliminated in most patients. Biopsies performed while patients are taking NSAIDs/aspirin can safely be performed. Adopting revised preprocedural laboratory criteria can result in decreased time to completion of biopsies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Co-orchestration of multiple instruments to uncover structure–property relationships in combinatorial libraries

The rapid growth of automated and autonomous instrumentation brings forth opportunities for the co-orchestration of multimodal tools that are equipped with multiple sequential detection methods or several characterization techniques to explore identical samples. This is exemplified by combinatorial libraries that can be explored in multiple locations via multiple tools simultaneously or downstream characterization in automated synthesis systems. In co-orchestration approaches, information gained in one modality should accelerate the discovery of other modalities. Correspondingly, an orchestrating agent should select the measurement modality based on the anticipated knowledge gain and measurement cost. Herein, we propose and implement a co-orchestration approach for conducting measurements with complex observables, such as spectra or images. The method relies on combining dimensionality reduction by variational autoencoders with representation learning for control over the latent space structure and integration into an iterative workflow via multi-task Gaussian Processes (GPs). This approach further allows for the native incorporation of the system's physics via a probabilistic model as a mean function of the GPs. We illustrate this method for different modes of piezoresponse force microscopy and micro-Raman spectroscopy on a combinatorial Sm-BiFeO3 library. However, the proposed framework is general and can be extended to multiple measurement modalities and arbitrary dimensionality of the measured signals.

47 OTHER INSTRUMENTATION↗

PSF–NET: A Nonparametric Point-spread Function Model for Ground-based Optical Telescopes

Ground-based optical telescopes are seriously affected by atmospheric turbulence induced aberrations. Understanding properties of these aberrations is important both for instrument design and image restoration method development. Because the point-spread function can reflect performance of the whole optic system, it is appropriate to use the point-spread function to describe atmospheric turbulence induced aberrations. Assuming point-spread functions induced by the atmospheric turbulence with the same profile belong to the same manifold space, we propose a nonparametric point-spread function—PSF–NET. The PSF–NET has a cycle convolutional neural network structure and is a statistical representation of the manifold space of PSFs induced by the atmospheric turbulence with the same profile. Testing the PSF–NET with simulated and real observation data, we find that a well trained PSF–NET can restore any short exposure images blurred by atmospheric turbulence with the same profile. Besides, we further use the impulse response of the PSF–NET, which can be viewed as the statistical mean PSF, to analyze interpretation properties of the PSF–NET. We find that variations of statistical mean PSFs are caused by variations of the atmospheric turbulence profile: as the difference of the atmospheric turbulence profile increases, the difference between statistical mean PSFs also increases. The PSF–NET proposed in this paper provides a new way to analyze atmospheric turbulence induced aberrations, which would benefit the development of new observation methods for ground-based optical telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Scatter and Blur Corrections for High-Energy X-Ray Radiography

High-energy X-ray radiography is useful as a highly penetrating method for imaging through dense materials. However, the primary modes of interaction of X-rays at these energies involve scattering or the production of secondary high-energy photons, which can interfere with the image. In addition, detector blurring, often resulting from scatter within the detector, can reduce image sharpness. Both of these processes can be mitigated with the use of convolution kernels, with the main challenge being that the proper kernel to use is not known, particularly for the scatter contribution. By radiographing solid slabs of uniform attenuation, we show that point spread functions and material-specific point scatter functions can be determined to significantly reduce the effect of detector blurring and object scatter. Constraining the fits to the slabs and uniform transmission within the slabs is sufficient to recover these functions. A functional form that reproduces the angular distribution of high-energy bremsstrahlung X-rays is presented for recovering point scatter functions. In conclusion, the method is applied to radiographs of objects from bremsstrahlung X-ray sources operating at 4- and 7.5-MV endpoint energies and a significant increase in sharpness is observed.

Blind deconvolution↗

Real time processor for array speckle interferometry

The authors are constructing a real-time processor to acquire image frames, perform array flat-fielding, execute a 64 x 64 element two-dimensional complex FFT (fast Fourier transform) and average the power spectrum, all within the 25 ms coherence time for speckles at near-IR (infrared) wavelength. The processor will be a compact unit controlled by a PC with real-time display and data storage capability. This will provide the ability to optimize observations and obtain results on the telescope rather than waiting several weeks before the data can be analyzed and viewed with offline methods. The image acquisition and processing, design criteria, and processor architecture are described.

Chin, Gordon↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic structure orientation as a map of in-plane antiferroelectricity in β'-In 2 Se 3

Antiferroelectric (AFE) materials are excellent candidates for sensors, capacitors, and data storage due to their electrical switchability and high-energy storage capacity. However, imaging the nanoscale landscape of AFE domains is notoriously inaccessible, which has hindered development and intentional tuning of AFE materials. Here, we demonstrate that polarization-dependent photoemission electron microscopy can resolve the arrangement and orientation of in-plane AFE domains on the nanoscale, despite the absence of a net lattice polarization. Through direct determination of electronic transition orientations and analysis of domain boundary constraints, we establish that antiferroelectricity in β'-In 2 Se 3 is a robust property from the scale of tens of nanometers to tens of micrometers. Ultimately, the method for imaging AFE domain organization presented here opens the door to investigations of the influence of domain formation and orientation on charge transport and dynamics.

36 MATERIALS SCIENCE↗

Endophyte-Promoted Phosphorus Solubilization in Populus

Phosphorus is an important plant nutrient, but in soils the majority of phosphorus, present in the form of a phosphate, forms metal complexes in soil making it relatively unavailable to plants. Therefore, inorganic phosphate solubilization is an important process of plant growth promotion by plant associated bacteria and fungi. Non nodulating plant species have been shown to thrive in low-nutrient environments, in some instances by relying on plant associated microorganisms called endophytes. These microorganisms live within the plant and help supply nutrients for the plant. Despite their potential enormous environmental importance, there are a limited number of studies looking at the direct molecular impact of phosphate solubilizing endophytic bacteria on the host plant. In this work, we studied the impact of two endophyte strains of wild poplar (Populus trichocarpa) that solubilize phosphate. Using a combination of x-ray imaging, spectroscopy methods, and proteomics we report direct evidence of endophyte-promoted phosphorus uptake in poplar. We found that the solubilized phosphate inside the plant may react and become insoluble again suggesting that the phosphate could be re-released within the plant by endophytes. Using synchrotron x-ray fluorescence spectromicroscopy combined with x-ray absorption near-edge structure, we visualized the nutrient phosphorus inside poplar roots inoculated by the selected endophytes and found the phosphorus in both forms of organic and inorganic phosphates inside the root. Tomography-based root imaging revealed a markedly different root biomass and root architecture for poplar samples inoculated with the phosphate solubilizing bacteria strains. Proteomics characterization on poplar roots coupled with protein network analysis revealed novel proteins and metabolic pathways with possible involvement in endophyte enriched phosphorus uptake. These findings suggest an important role of endophytes for phosphorus acquisition and provide a deeper understanding of the critical symbiotic associations between poplar and the endophytic bacteria.

36 MATERIALS SCIENCE↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Three-dimensional coherent X-ray diffraction imaging via deep convolutional neural networks

Abstract As a critical component of coherent X-ray diffraction imaging (CDI), phase retrieval has been extensively applied in X-ray structural science to recover the 3D morphological information inside measured particles. Despite meeting all the oversampling requirements of Sayre and Shannon, current phase retrieval approaches still have trouble achieving a unique inversion of experimental data in the presence of noise. Here, we propose to overcome this limitation by incorporating a 3D Machine Learning (ML) model combining (optional) supervised learning with transfer learning. The trained ML model can rapidly provide an immediate result with high accuracy which could benefit real-time experiments, and the predicted result can be further refined with transfer learning. More significantly, the proposed ML model can be used without any prior training to learn the missing phases of an image based on minimization of an appropriate ‘loss function’ alone. We demonstrate significantly improved performance with experimental Bragg CDI data over traditional iterative phase retrieval algorithms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Convexity properties of images under nonlinear integral operators

Conditions are obtained for the image of a given set under a general completely continuous nonlinear integral operator to have convex closure. These results are used to establish the uniqueness of quasi-solutions of nonlinear integral equations of the first kind and to prove the solvability of equations of the first kind on a dense subset of the right-hand sides. Bibliography: 11 titles.

97 MATHEMATICS AND COMPUTING↗

SU-G-IeP1-09: MRI Evaluation of a Direction-Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer On 3T

Purpose: To assess image quality and artifact extent of a novel direction modulated brachytherapy (DMBT) tandem applicator on a 3T MRI using various clinical imaging sequences. Methods: The tandem applicator is composed of a tungsten alloy with 6 peripheral grooves covered with a PEEK tip. An MR-compatible phantom with similar dimensions to the female pelvis was manufactured. To visually assess the spatial shift of the applicator’s tip, a mountable radial-fiducial with 4 plastic rods, each of 3mm diameter, was designed to tightly fit on the applicator. The rods are separated by 16 mm and mounted at 90-degree relative to one another. The pelvis phantom was filled with a solution of MnCl2 to mimic T2 relaxation time of the cervix (60-80 ms at 3T).Imaging was performed on a 3T Philips Achieva using a 16-channel Torso coil array. Four MR sequences were tested: T2-weighted fast spin-echo (T2w-FSE), proton density weighted FSE (PDw-FSE), T1-weighted FSE (T1w-FSE) and T1 weighted spoiled gradient echo (T1w-GE). The spatial resolution was kept the same between all sequences: 0.6 × 0.6 × 3 mm{sup 3} with no slice gaps. Para-sagittal images were acquired with the applicator fixed at a 30-degree angle anterior to the B0- field to mimic clinical settings. Results: Minimal artifacts were observed on T2w-FSE, PDw-FSE and T1-FSE, while significant artifacts were seen on T1w-GE images. Artifacts induced in all 3 FSE sequences did not hinder accurate localisation of the tip and the applicator boundaries. The drift of the applicator’s centreline from the radial fiducials was measured and found to be < 1 mm for the 3 FSE sequences. Conclusion: The tungsten–based DMBT applicator can be potentially used on 3T with various clinical sequences without inducing significant artifacts. Further validation on patients as well as the evaluation of relative SNR among the different sequences is required.

60 APPLIED LIFE SCIENCES↗

An Investigation of the Wear Performance of Aged Inconel 718 Superalloy by the Fuzzy Logic Approach

In this study, the effects of δ, γ′ and γ″ phases on the microstructure and wear behavior of Inconel 718 alloy, produced by powder metallurgy technique, were analyzed experimentally and a fuzzy logic model was developed for the weight loss prediction after the wear tests. Aging process was carried out in two stages: firstly at 720 °C for 8 h and then at 620 °C for 6-10 h. Wear tests were performed at five different sliding distances (400-2000 m) for 1 ms{sup −1} sliding speed under 30 to 60 N loads. Weight loss prediction model was developed by using fuzzy logic method. SEM images of Inconel 718 alloy aged for 6, 8 and 10 h at 620 °C show intermetallic precipitates formed around particle boundaries. XRD examinations showed orthorhombic δ (Ni{sub 3}Nb), BCT γ″ (Ni{sub 3}Nb), FCC γ′ Ni{sub 3}(Al,Ti) hexagonal Laves (Fe{sub 2}Nb) phases formed in the structure with the same chemical composition and different crystal lattice. Accurate estimates were obtained in the developed fuzzy logic model. It was illustrated that this fuzzy logic model can be used successfully for the prediction of weight loss in wear tests of Inconel 718 alloy that was produced by powder metallurgy method.

36 MATERIALS SCIENCE↗