Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512

Purpose: Silicon diode arrays are commonly implemented in radiation therapy quality assurance applications as they have a number of advantages including: real time operation (compared to the film) and high spatial resolution, large dynamic range and small size (compared to ionizing chambers). Most diode arrays have detector pitch that is too coarse for routine use in small field applications. The goal of this work is to characterize the two-dimensional monolithic silicon diode array named “MagicPlate-512” (MP512) designed for QA in stereotactic body radiation therapy (SBRT) and stereotactic radio surgery (SRS). Methods: MP512 is a silicon monolithic detector manufactured on ap-type substrate. An array contains of 512 pixels with size 0.5 × 0.5 mm{sup 2} and pitch 2 mm with an overall dimension of 52 × 52 mm{sup 2}. The MP512 monolithic detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of raisin to preserve the silicon detector from moisture and chemical contamination and to protect the bonding wires. Characterization of the silicon monolithic diode array response was performed, and included pixels response uniformity, dose linearity, percent depth dose, output factor, and beam profiling for beam sizes relevant to SBRT and SRS and depth dose response in comparison with ionization chamber. Results: MP512 shows a good dose linearity (R{sup 2} = 0.998) and repeatability within 0.2%. The measured depth dose response for field size of 10 × 10 cm{sup 2} agreed to within 1.3%, when compared to a CC13 ionization chamber for depths in PMMA up to 30 cm. The output factor of a 6 MV Varian 2100EX medical linac beam measured by MP512 at the isocenter agrees to within 2% when compared to PTW diamond, Scanditronix point EDD-2 diode and MOSkin detectors for field sizes down to 1 × 1 cm{sup 2}. An over response of 4% was observed for square beam size smaller than 1 cm when compared to EBT3 films, while the beam profiles (FWHM) of MP512 match to within 2% the data measured by radiochromic film. Conclusions: The response of the 2D detector array, MP512, has been evaluated. The properties of the array demonstrated suitability for use as in phantom dosimeter for QA in SRS and SBRT. Although MP512 matches film measurements down to 1 × 1 cm{sup 2} well, it showed a discrepancy of 4% in the determination of output factors of beams smaller than 0.5 × 0.5 cm{sup 2} due to the field perturbation generated by the large amount of silicon surrounding the central diode. MP512 is highly capable of measuring beam size (FWHM) and has a discrepancy of less than 1.3% when compared to EBT3 film. A reduction in the detector pitch to less than 2 mm would improve the penumbra reconstruction accuracy at the cost readout electronics complexity.

07 ISOTOPE AND RADIATION SOURCES↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review and Evaluation of Updated Research on the Health Effects Associated with Low-Dose Ionizing Radiation

Potential health effects of low levels of radiation have predominantly been based on those effects observed at high levels of radiation. The authors have reviewed more than 200 percent publications in radiobiology and epidermiology related to low dose radiation and concluded that recent radiobiological studies at low-doses; that doses <100 mSv in a single exposure appear to be too small to allow epidermiological detection of statistically significant excess cancers in the presence of naturally occurring cancers; that low dose radiation research should to holistic, systems-based approaches to develop models that define the shape of the dose-response relationships at low doses; and that these results should be combined with the latest epidermiology to produce a comprehensive understanding of radiation effects that addresses both damage, likely with a linear effect, and response, possibly with non-linear consequences.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

Performance of a continuously rotating half-wave plate on the POLARBEAR telescope

A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, I, Q and U, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of ~0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization (I→P) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the {\scshape Polarbear} experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the I→P leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz (ℓ ~ 39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.

79 ASTRONOMY AND ASTROPHYSICS↗

Response analysis of a laminar premixed M-flame to flow perturbations using a linearized compressible Navier-Stokes solver

The response of a laminar premixed methane-air flame subjected to flow perturbations around a steady state is examined experimentally and using a linearized compressible Navier-Stokes solver with a one-step chemistry mechanism to describe combustion. The unperturbed flame takes an M-shape stabilized both by a central bluff body and by the external rim of a cylindrical nozzle. This base flow is computed by a nonlinear direct simulation of the steady reacting flow, and the flame topology is shown to qualitatively correspond to experiments conducted under comparable conditions. The flame is then subjected to acoustic disturbances produced at different locations in the numerical domain, and its response is examined using the linearized solver. This linear numerical model then allows the componentwise investigation of the effects of flow disturbances on unsteady combustion and the feedback from the flame on the unsteady flow field. It is shown that a wrinkled reaction layer produces hydrodynamic disturbances in the fresh reactant flow field that superimpose on the acoustic field. This phenomenon, observed in several experiments, is fully interpreted here. The additional perturbations convected by the mean flow stem from the feedback of the perturbed flame sheet dynamics onto the flow field by a mechanism similar to that of a perturbed vortex sheet. The different regimes where this mechanism prevails are investigated by examining the phase and group velocities of flow disturbances along an axis oriented along the main direction of the flow in the fresh reactant flow field. It is shown that this mechanism dominates the low-frequency response of the wrinkled shape taken by the flame and, in particular, that it fully determines the dynamics of the flame tip from where the bulk of noise is radiated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic response analysis of geometrically non-linear structures subjected to high impact.

Description of an efficient digital computer method for the determination of the propagation of elastic stresses and deformations in certain geometrically nonlinear structures subjected to high impact loading. The finite-element matrix displacement approach utilizing curved quadrilateral shell elements in conjunction with a nodewise predictor-corrector method employing Runge-Kutta extrapolation techniques has been adopted for the present solution. The related computer program written in FORTRAN V for the UNIVAC 1108 computer has proved to be effective for the solution of a range of practical problems including rectangular and cylindrical panels. Numerical results are presented for a relevant structure, the cell container, and the negative electrode of an impact-resistant battery subjected to high impact, simulating its free landing on a planetary surface.

Gupta, K. K.↗

Recursive Inversion By Finite-Impulse-Response Filters

Recursive approximation gives least-squares best fit to exact response. Algorithm yields finite-impulse-response approximation of unknown single-input/single-output, causal, time-invariant, linear, real system, response of which is sequence of impulses. Applicable to such system-inversion problems as suppression of echoes and identification of target from its scatter response to incident impulse.

Bach, Ralph E., Jr.↗

Liquid Jet Response to Detonation Waves in a Linear Detonation Combustor

The impact of periodic detonation wave impact on a liquid fuel jet is investigated in a linear detonation combustor. The linear detonation combustor operated with gaseous natural gas and oxygen generates sustained, self-excited detonation waves that propagate along its length at approximately 8 kHz, representing a wave propagation frequency in typical rocket rotating detonation engines. The effect of the detonation wave on the dynamic injection and break-up of a single diesel jet injected into the combustion chamber at varying injection pressures is evaluated with chemiluminescence, fuel planar laser induced fluorescence and Mie scattering measurements at 100 kHz. The detonation wave significantly impacts the liquid jet trajectory with its deflection in both windward and leeward direction as the adverse pressure gradient across it changes between wave passages. The maximum recovery height of the liquid jet is observed to be consistent across all operating conditions, and dependent on the detonation wave strength in the chamber.

propulsion↗

2013 POLAR MARINE SCIENCE GORDON RESEARCH CONFERENCE AND GORDON RESEARCH SEMINAR (MARCH 10-15, 2013 - FOUR POINTS SHERATON, VENTURA CA)

As dynamic and thermodynamic processes associated with warming trends are impacting sea ice cover, oceanographic processes and atmosphere-ocean interactions across polar regions at unprecedented rate, observations and models show fundamentally different regional ecosystem responses. The non-linear and multi-directional biogeochemical responses of polar systems to atmospheric and oceanographic forcings emphasize the need to consider and reconcile observations and models at global and regional scales. The 9th GRC on Polar Marine Science will discuss recent developments and challenges emerging from contemporary and paleo-climate observations and models, encompassing regional and global scales. The GRC addresses the structure, functionalities and controls of polar marine systems through topics such as sea ice biogeochemistry, atmosphere-ocean forcings and interactions, food web trophodynamics, carbon and elemental cycling and fluxes, and a spectrum of ecological processes and interactions.

58 GEOSCIENCES↗

Modern sensitivity analysis - 15651

Sensitivity analysis has been applied to complex models, such as performance assessment models, since at least the advent of computational tools to support such an approach to model evaluation. Initially, sensitivity analysis methods were applied to deterministic models and focused on changing one input variable at a time. Probabilistic modeling opened the door to evaluating changes in all input variables simultaneously. Standardized rank regression methods were primarily used in the last century to evaluate probabilistic models. These methods assume linearity in the rank response of the model to the inputs. At the very least this assumes monotonicity in the response, but for the most part the response needs to be near-linear. This is highly unlikely for performance assessment models that are based on differential equations, multiplication and division of variables that are usually not correlated, and conservatism that is not well understood. There are better statistical methods for evaluating highly non-linear and dynamic probabilistic models. Some of these methods were founded in the data mining industry. This century has seen a rapid development of the internet that led directly to the development of data mining techniques for massive databases. Although the goals were different, these techniques can be adapted to sensitivity analysis for complex probabilistic models, which, also, form large, or even massive, databases. These modern sensitivity analysis procedures assess the importance of every explanatory variable (input parameters) used in a probabilistic model. In practice, this means that for each endpoint of interest, every explanatory variable in the model is associated with a quantitative measure of importance. For a given explanatory variable, the importance value depends on the endpoint of interest. This global approach to sensitivity analysis allows all levels of interactions to be evaluated, so that the variation in the output can be measured at every level of possible interaction. The effects are collected together during sensitivity analysis processing, and then separated out to attribute the overall contribution of each input parameter to the model output. These global sensitivity analysis procedures have the ability to characterize non-linear and non-monotonic relationships between explanatory variables and endpoints of interest. This is critically important because of the need to characterize complex interactions among multiple explanatory variables in PA models that often have non-linear and non-monotonic effects. The options for sensitivity analysis are fully explored, including an evaluation of several methods when applying them to a well-known complex non-linear non-monotonic model. The results clearly demonstrate the relative benefit of using data mining methods over simple statistical approaches such as standardized rank regression. (authors)

97 MATHEMATICS AND COMPUTING↗

Finite element analysis of large transient elastic-plastic deformations of simple structures, with application to the engine rotor fragment containment/deflection problem

Assumed-displacement versions of the finite-element method are developed to predict large-deformation elastic-plastic transient deformations of structures. Both the conventional and a new improved finite-element variational formulation are derived. These formulations are then developed in detail for straight-beam and curved-beam elements undergoing (1) Bernoulli-Euler-Kirchhoff or (2) Timoshenko deformation behavior, in one plane. For each of these categories, several types of assumed-displacement finite elements are developed, and transient response predictions are compared with available exact solutions for small-deflection, linear-elastic transient responses. The present finite-element predictions for large-deflection elastic-plastic transient responses are evaluated via several beam and ring examples for which experimental measurements of transient strains and large transient deformations and independent finite-difference predictions are available.

Wu, R. W.↗

Development of a simplified analytical method for representing material cyclic response

Development of a simplified method for estimating structural inelastic stress and strain response to cyclic thermal loading is presented. The method assumes that high temperature structural response is the sum of time independent plastic and time dependent elastic/creep components. The local structural stress and strain response predicted by linear elastic analysis is modified by the simplified method to predict the inelastic response. The results with simulations by a nonlinear finite element analysis and used time independent plasticity and unified time dependent material model are compared.

Moreno, V.↗

Effect of Injection Dynamics on Wave Propagation in a Linear Detonation Combustor

Injector response to self-excited and sustained detonation wave propagation in an optically-accessible nonpremixed natural gas-oxygen linear detonation combustor is investigated. 100 kHz measurements of planar laser induced fluorescence (PLIF) of trace quantities of acetone injected into the fuel supply and simultaneous OH∗ chemiluminescence measurements were used to correlate the effect on injection dynamics on detonation wave structure and propagation. Measurements over a range of equivalence ratios (0.61-1.48) revealed wave propagation through regions of high fuel stratification in the axial and transverse direction of reactant injection. Consequently, the propagation of the detonation wave along the channel is through a flow-field with significant variation in fuel mass fraction, reactivity, and sound speeds. At lean conditions, wave propagation frequency is generally lower (∼6 kHz) resulting in longer time between wave passages for mixing and pre-heat resulting in steeper detonation wave-fronts anchored near the injector exit plane. Conversely, at rich equivalence ratios the wave frequency is higher (∼10 kHz) resulting in shorter intra-cycle period for reactant fill and mixing resulting waves lifted from the injection plane that are more compact. Higher chemiluminescence intensity in the post-wave region with deflagrative combustion is observed in these cases. Phase averaged representation of the acetone-PLIF measurements indicate that the fraction of time between wave passages available for reactant fill, mixing and pre-heat is consistent across all equivalence ratios.

Propulsion↗

Effect of Injection Dynamics on Detonation Wave Propagation in a Linear Detonation Combustor

Injector response to self-excited and sustained detonation wave propagation in an optically-accessible nonpremixed natural gas-oxygen linear detonation combustor is investigated. 100 kHz measurements of planar laser induced fluorescence (PLIF) of trace quantities of acetone injected into the fuel supply and simultaneous OH∗ chemiluminescence measurements were used to correlate the effect on injection dynamics on detonation wave structure and propagation. Measurements over a range of equivalence ratios (0.61-1.48) revealed wave propagation through regions of high fuel stratification in the axial and transverse direction of reactant injection. Consequently, the propagation of the detonation wave along the channel is through a flow-field with significant variation in fuel mass fraction, reactivity, and sound speeds. At lean conditions, wave propagation frequency is generally lower (∼6 kHz) resulting in longer time between wave passages for mixing and pre-heat resulting in steeper detonation wave-fronts anchored near the injector exit plane. Conversely, at rich equivalence ratios the wave frequency is higher (∼10 kHz) resulting in shorter intra-cycle period for reactant fill and mixing resulting waves lifted from the injection plane that are more compact. Higher chemiluminescence intensity in the post-wave region with deflagrative combustion is observed in these cases. Phase averaged representation of the acetone-PLIF measurements indicate that the fraction of time between wave passages available for reactant fill, mixing and pre-heat is consistent across all equivalence ratios.

Propulsion↗

Deformation Behavior of Solid-Solution-Strengthened Mg-9wt%Al Alloy: In-Situ Neutron Diffraction and Elastic-Viscoplastic Self-Consistent Modeling

In situ neutron diffraction and elastic viscoplastic self-consistent (EVPSC) modeling have been employed to understand the deformation mechanisms of the loading unloading process under uniaxial tension in a solid-solution-strengthened extruded Mg 9 wt.% Al alloy. The initial texture measured by neutron diffraction shows that the {00.2} basal planes in most grains are tilted around 20 30 from the extrusion axis, indicating that basal slip should be easily activated in a majority of grains under tension. Non-linear stress strain responses are observed during unloading and reloading after the material is fully plastically deformed under tension. In situ neutron diffraction measurements have also demonstrated the non-linear behavior of lattice strains during unloading and reloading, revealing that load redistribution continuously occurs between soft and hard grain orientations. The predicted macroscopic stress strain curve and the lattice strain evolution by the EVPSC model are in good agreement with the experimental data. The EVPSC model provides the relative activities of the available slip and twinning modes, as well as the elastic and plastic strains of the various grain families. It is suggested that the non-linear phenomena in the macroscopic stress strain responses and microscopic lattice strains during unloading and reloading are due to plastic deformation by the operation of basal a slip in the soft grain orientations (e.g. {10.1}, {11.2} and {10.2} grain families).

Lee, Sooyeol↗