Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

Multifractal moments in heavy ion Pb-Pb collisions at 158 A GeV

In present work, we use the method of scaled factorial moments to search for intermittent behavior in Pb-Pb interactions at 158 A GeV. The analysis is done on photon distributions obtained using preshower photon multiplicity detector. Scaled factorial moments are used to study short range fluctuations in pseudorapidity distributions of photons. Scaled factorial moments are calculated using horizontal corrected and vertical analysis. The results are compared with simulation analysis using VENUS event generator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-64: A Programmable Moving Insert for the ArcCHECK Phantom for Dose Verification of Respiratory-Gated VMAT

Purpose: To present a customized programmable moving insert for the ArcCHECK™ phantom that can, in a single delivery, check both entrance dosimetry, while simultaneously verifying the delivery of respiratory-gated VMAT. Methods: The cylindrical motion phantom uses a computer-controlled stepping motor to move an insert inside a stationery sleeve. Insert motion is programmable and can include rotational motion in addition to linear motion along the axis of the cylinder. The sleeve fits securely in the bore of the ArcCHECK™. Interchangeable inserts, including an A1SL chamber, optically-stimulated luminescence dosimeters, radiochromic film, or 3D gels, allow this combination to be used for commissioning, routine quality assurance, and patient-specific dosimetric verification of respiratory-gated VMAT. Before clinical implementation, the effect of a moving insert on the ArcCHECK™ measurements was considered. First, the measured dose to the ArcCHECK™ containing multiple inserts in the static position was compared to the calculated dose during multiple VMAT treatment deliveries. Then, dose was measured under both sinusoidal and real-patient motion conditions to determine any effect of the moving inserts on the ArcCHECK™ measurements. Finally, dose was measured during gated VMAT delivery to the same inserts under the same motion conditions to examine any effect of various beam “on-and-off” and dose rate ramp “up-and-down”. Multiple comparisons between measured and calculated dose to different inserts were also considered. Results: The pass rate for the static delivery exceeded 98% for all measurements (3%/3mm), suggesting a valid setup for entrance dosimetry. The pass rate was not altered for any measurement delivered under motion conditions. A similar Result was observed under gated VMAT conditions, including agreement of measured and calculated dose to the various inserts. Conclusion: Incorporating a programmable moving insert within the ArcCHECK™ phantom provides an efficient verification of respiratory-gated VMAT delivery that is useful during commissioning, routine quality assurance, and patient-specific dose verification. Prototype phantom development and testing was performed in collaboration with Modus Medical Devices Inc. (London, ON). No financial support was granted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A pencil beam approach to proton computed tomography

Purpose: A new approach to proton computed tomography (pCT) is presented. In this approach, protons are not tracked one-by-one but a beam of particles is considered instead. The elements of the pCT reconstruction problem (residual energy and path) are redefined on the basis of this new approach. An analytical image reconstruction algorithm applicable to this scenario is also proposed. Methods: The pencil beam (PB) and its propagation in matter were modeled by making use of the generalization of the Fermi–Eyges theory to account for multiple Coulomb scattering (MCS). This model was integrated into the pCT reconstruction problem, allowing the definition of the mean beam path concept similar to the most likely path (MLP) used in the single-particle approach. A numerical validation of the model was performed. The algorithm of filtered backprojection along MLPs was adapted to the beam-by-beam approach. The acquisition of a perfect proton scan was simulated and the data were used to reconstruct images of the relative stopping power of the phantom with the single-proton and beam-by-beam approaches. The resulting images were compared in a qualitative way. Results: The parameters of the modeled PB (mean and spread) were compared to Monte Carlo results in order to validate the model. For a water target, good agreement was found for the mean value of the distributions. As far as the spread is concerned, depth-dependent discrepancies as large as 2%–3% were found. For a heterogeneous phantom, discrepancies in the distribution spread ranged from 6% to 8%. The image reconstructed with the beam-by-beam approach showed a high level of noise compared to the one reconstructed with the classical approach. Conclusions: The PB approach to proton imaging may allow technical challenges imposed by the current proton-by-proton method to be overcome. In this framework, an analytical algorithm is proposed. Further work will involve a detailed study of the performances and limitations of this approach in terms of image quality. The paper shows how to account for the MCS in the reconstruction step with this new approach when an analytical reconstruction algorithm is used.

60 APPLIED LIFE SCIENCES↗

Charge-equilibrium and radiation of low-energy cosmic rays passing through interstellar medium

The charge equilibrium and radiation of an oxygen and an iron beam in the MeV per nucleon energy range, representing a typical beam of low-energy cosmic rays passing through the interstellar medium, is considered. Electron loss of the beam has been taken into account by means of the First Born approximation allowing for the target atom to remain unexcited, or to be excited to all possible states. Electron capture cross sections have been calculated by means of the scaled Oppenheimer-Brinkman-Kramers approximation, taking into account all atomic shells of the target atoms. Radiation of the beam due to electron capture into the excited states of the ion, collisional excitation and collisional inner-shell ionization of the ions has been considered. Effective X-ray production cross sections and multiplicities for the most energetic X-ray lines emitted by the Fe and O beams have been calculated.

Rule, D. W.↗

Development of molecular beam epitaxy technology for III–V compound semiconductor heterostructure devices

Molecular beam epitaxy (MBE) is a versatile ultrahigh vacuum technique for growing multiple epitaxial layers of semiconductor crystals with high precision. The extreme control of the MBE technique over composition variation, interface sharpness, impurity doping profiles, and epitaxial layer thickness to the atomic level makes it possible to demonstrate a wide variety of novel semiconductor structures. Since its invention nearly 40 years ago, the MBE technique has evolved from a laboratory apparatus for exploring new materials and novel devices to a favored tool for the mass production of III–V high-speed devices. This paper will review some of the past developments in this technology and propose an outlook of future developments.

36 MATERIALS SCIENCE↗

Electron-irradiation-induced crystallization at metallic amorphous/silicon oxide interfaces caused by electronic excitation

Irradiation-induced crystallization of an amorphous phase was stimulated at a Pd-Si amorphous/silicon oxide (a(Pd-Si)/SiO{sub x}) interface at 298 K by electron irradiation at acceleration voltages ranging between 25 kV and 200 kV. Under irradiation, a Pd-Si amorphous phase was initially formed at the crystalline face-centered cubic palladium/silicon oxide (Pd/SiO{sub x}) interface, followed by the formation of a Pd{sub 2}Si intermetallic compound through irradiation-induced crystallization. The irradiation-induced crystallization can be considered to be stimulated not by defect introduction through the electron knock-on effects and electron-beam heating, but by the electronic excitation mechanism. The observed irradiation-induced structural change at the a(Pd-Si)/SiO{sub x} and Pd/SiO{sub x} interfaces indicates multiple structural modifications at the metal/silicon oxide interfaces through electronic excitation induced by the electron-beam processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments

We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 Multiplication-Sign 10{sup 17} m{sup -3}, i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

43 PARTICLE ACCELERATORS↗

Patch-Based Convolutional Neural Networks for Multiple Microstructural Features Detection in FIB-SEM Micrographs of Irradiated Nuclear Fuel

Focused ion beam scanning electron microscopy (FIB-SEM) tomography has increasingly been utilized for acquiring three-dimensional (3D) microstructure features at the sub-micron scale in irradiated nuclear materials. This technique involves sequential ion beam slicing followed by electron beam imaging and compositional mapping using energy dispersive spectroscopy (EDS). Despite its growing use, several challenges persist. These include the time-intensive nature of data collection of EDS data, difficulties in distinguishing between various microstructures, and issues with image alignment. These challenges currently limit the broader application of FIB-SEM tomography in the field. To overcome these limitations, we propose using convolutional neural networks (CNNs) to automate microstructure identification in SEM images. Our study introduces a new framework for identifying microstructures in irradiated U-10Zr (wt. %) metallic fuel with limited annotated data. The framework includes the creation of a reliable annotated dataset with paired SEM and ground truth data from EDS maps, the applications of CNNs for microstructure identification, and the validation of model performance. Specifically, we employed the Segment Anything Model (SAM) to align SEM images with corresponding EDS maps and focused ion beam (FIB) tomography SEM data. We evaluate several models, including Patch-based U-Net, Attention U-Net, and Residual U-Net, finding that patch-based U-Net exhibits superior segmentation performance and consistency. This approach reduces reliance on EDS detectors and aids in accelerating nuclear material analysis process, highlighting the potential of advanced deep learning techniques to improve microstructural understanding in nuclear material. This is the first framework to integrate SAM and Patch-based CNN models for semantic segmentation of irradiated nuclear materials, with potential applicability to other tomography datasets.

36 - MATERIALS SCIENCE↗

Beamline Volume Relief Analysis for the PIP-II SSR2 Cryomodule at Fermilab

The beam volume of the Pre-Production Single Spoke Resonator type 2 (ppSSR2) cryomodule [1] for the Proton Improvement Plan-II (PIP-II) [2] project will be protected against over-pressurization using a burst disk. This contribution focuses on the analysis of the relief of such trapped volume during a catastrophic scenario with multiple systems failures. An analytical model, able to predict the pressure in the beam volume depending of the various boundary conditions, has been developed and will be presented along with the results.

43 PARTICLE ACCELERATORS↗

Parallel general purpose multiobjective optimization framework with application to electron beam dynamics

Particle accelerators are invaluable tools for research in the basic and applied sciences, such as materials science, chemistry, the biosciences, particle physics, nuclear physics and medicine. The design, commissioning, and operation of accelerator facilities is a nontrivial task, due to the large number of control parameters and the complex interplay of several conflicting design goals. The Argonne Wakefield Accelerator facility has some unique challenges resulting from its purpose to carry out advanced accelerator R&D. Individual experiments often have challenging beam requirements, and the physical configuration of the beam lines is often changed to accommodate the variety of supported experiments. The need for rapid deployment of different operational settings further complicates the optimization work that must be done for multiple constraints and challenging operational regimes. One example of this is an independently staged two-beam acceleration experiment which requires the construction of an additional beam line (this is now in progress). The high charge drive beam, well into the space charge regime, must be threaded through small aperture (17.6 mm) decelerating structures. In addition, the bunch length must be sufficiently short to maximize power generation in the decelerator. We propose to tackle this problem by means of multiobjective optimization algorithms which also facilitate a parallel deployment. In order to compute solutions in a meaningful time frame, a fast and scalable software framework is required. In this paper, we present a general-purpose framework for simulation-based multiobjective optimization methods that allows the automatic investigation of optimal sets of machine parameters. Using evolutionary algorithms as the optimizer and opal as the forward solver, validation experiments and results of multiobjective optimization problems in the domain of beam dynamics are presented. Optimized solutions for the new high charge drive beam line found by the framework were used to finish the design of a two beam acceleration experiment. The selected solution along with the associated beam parameters is presented.

43 PARTICLE ACCELERATORS↗

Large-Area Material and Junction Damage in c–Si Solar Cells by Potential-Induced Degradation

This paper reports a new potential-induced degradation (PID) mechanism for crystalline silicon (c-Si), where Na diffuses everywhere and causes large-area material and junction degradation with point defects. Multiple characterization techniques are combined - Kelvin probe force microscopy, electron-beam induced current, dark lock-in thermography, transmission electron microscopy, time-of-flight secondary-ion mass spectrometry, and microwave photoconductance decay - as well as density functional theory (DFT) calculations. These characterization techniques and theoretical calculations are complementary in various aspects of a material's chemical, structural, electrical, and optoelectrical nature, as well as in atomic, nanometer, micrometer, millimeter, and cell and module scales. All results point consistently to a new discovery: substantial large-area deterioration of materials and junctions play a major role in c-Si PID (in addition to the previously reported local shunting defect caused by Na diffusion to planar defects). Furthermore, this new finding reveals a key PID component and leads to a new strategy for tailoring c-Si photovoltaics to ultimately resolve the PID issue.

14 SOLAR ENERGY↗

Molecular-beam epitaxy of heterostructures of wide-gap II–VI compounds for low-threshold lasers with optical and electron pumping

The paper presents basic approaches in designing and growing by molecular beam epitaxy of (Zn,Mg)(S,Se)-based laser heterostructures with multiple CdSe quantum dot (QD) sheets or ZnCdSe quantum wells (QW). The method of calculation of compensating short-period ZnSSe/ZnSe superlattices (SLs) in both active and waveguide regions of laser heterostructures possessing the different waveguide thickness and different number of active regions is presented. The method allowing reduction of the density of nonequilibrium point defects in the active region of the II–VI laser structures has been proposed. It utilizes the migration enhanced epitaxy mode in growing the ZnSe QW confining the CdSe QD sheet. The threshold power density as low as P{sub thr} ∼ 0.8 kW/cm{sup 2} at T = 300 K has been demonstrated for laser heterostructure with single CdSe QD sheet and asymmetric graded-index waveguide with strain-compensating SLs.

36 MATERIALS SCIENCE↗

Measuring correlations between beam loss and residual radiation in the Fermilab Main Injector

In order to control beam loss for high intensity operation of the Fermilab Main Injector, electronics has been implemented to provide detailed loss measurements using gas-filled ionization monitors. Software to enhance routine operation and studies has been developed and losses are logged for each acceleration cycle. A systematic study of residual radiation at selected locations in the accelerator tunnel have been carried out by logging residual radiation at each of 142 bar-coded locations. We report on fits of the residual radiation measurements to half-life weighted sums of the beam loss data using a few characteristic lifetimes. The data are now available over a multi-year period including residual radiation measurements repeated multiple times during three extended facility shutdown periods. Measurement intervals of a few weeks combined with variable delays between beam off time and the residual measurement permits sensitivity to lifetimes from hours to years. The results allow planning for work in radiation areas to be based on calibrated analytic models.

43 PARTICLE ACCELERATORS↗

Identifying Longitudinal Jitter Sources in the LCLS Linac

The Linac Coherent Light Source (LCLS) at SLAC is an x-ray Free Electron Laser (FEL) with wavelengths of 0.15 nm to 1.5 nm. The electron beam stability is important for good lasing. While the transverse jitter of the beam is about 10-20% of the rms beam sizes, the jitter in the longitudinal phase space is a multiple of the energy spread and bunch length. At the lower energy of 4.3 GeV (corresponding to the longest wavelength of 1.5 nm) the relative energy jitter can be 0.125%, while the rms energy spread is with 0.025% five times smaller. An even bigger ratio exists for the arrival time jitter of 50 fs and the bunch duration of about 5 fs (rms) in the low charge (20 pC) operating mode. Although the impact to the experiments is reduced by providing pulse-by-pulse data of the measured energy and arrival time, it would be nice to understand and mitigate the root causes of this jitter. The thyratron of the high power supply of the RF klystrons is one of the main contributors. Another suspect is the multi-pacting in the RF loads. Phase measurements down to 0.01 degree (equals 10 fs) along the RF pulse were achieved, giving hints to the impact of the different sources.

43 PARTICLE ACCELERATORS↗

Laser beam combiner for Thomson scattering core LIDAR

The light detection and ranging Thomson scattering (TS) diagnostic is advantageous since it only requires a single view port into the tokamak. This technique requires a short pulse laser at high energy, usually showing a limited repetition rate. Having multiple lasers will increase the repetition rate. This paper presents a scanning mirror as a laser beam combiner. Measurements of the position accuracy and jitter show that the pointing stability of the laser beam is within {+-}25 {mu}rad for over tens of seconds. A control feedback loop is implemented to demonstrate the long term stability. Such a system could be applied for ITER and JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System tests with electric thruster beam and accelerator directly powered from laboratory solar arrays

Laboratory high voltage solar arrays were operated directly connected to power the beam and accelerator loads of an 8-centimeter ion thruster. The beam array comprised conventional 2 by 2 centimeter solar cells; the accelerator array comprised multiple junction edge-illuminated solar cells. Conventional laboratory power supplies powered the thruster's other loads. Tests were made to evaluate thruster performance and to investigate possible electrical interactions between the solar arrays and the thruster. Thruster performance was the same as with conventional laboratory beam and accelerator power supplies. Most of the thruster beam short circuits that occurred during solar array operation were cleared spontaneously without automatic or manual intervention. No spontaneous clearing occurred during conventional power supply operation.

Stover, J. B.↗

Electron acceleration through two successive electron beam driven wakefield acceleration stages

Structure based wakefield acceleration may provide a viable approach for accelerating sufficiently large numbers of electrons and positrons at the high gradient needed to meet the luminosity, efficiency, and cost requirements of a future linear collider. An important step in proving its viability is the demonstration of acceleration in multiple stages. Here we show the results of the first experimental demonstration of staged two beam wakefield acceleration, conducted at the Argonne Wakefield Accelerator Facility (AWA), in which a 0.5 nC electron bunch gained equal amounts of energy in two stages (~2.4 MeV per stage, corresponding to an average acceleration gradient of ~70 MeV/m). Meanwhile 150MeV/m of acceleration in a single stage has been achieved. The demonstration experiment should be scalable to staged-acceleration at gradients of the order of 200 to 300 MeV/m. Furthermore, such a development would considerably reduce both the cost and footprint of both a future high-energy physics (HEP) collider, as well as future X-ray light sources.

43 PARTICLE ACCELERATORS↗