Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear data validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Power Burst Facility: U(18)O2-CaO-ZrO2 Fuel Rods in Water

The Power Burst Facility (PBF) reactor operated from 1972 to 1985 on the SPERT Area I of the Idaho National Laboratory, then known as Nuclear Reactor Test Station. PBF was designed to provide experimental data to aid in defining thresholds for and modes of failure under postulated accident conditions. PBF reactor startup testing began in 1972. This evaluation focuses on two operational loading tests, chronologically numbered 1 and 2, published in a startup-test report in 1974 [1]. Data for these tests was used by one of the authors to validate a MCNP model for criticality safety purposes [2]. Although specific references to original documents are kept in the text, all the reactor parameters and test specific data presented here was adapted from that report. The tests were performed with operational fuel loadings, a stainless steel in-pile tube (IPT) mockup, a neutron source, four pulse chambers, two fission chambers, and one ion chamber. The reactor's four transition rods (TRs) and control rods (CRs) were present but TR boron was completely withdrawn below the core and CR boron was partially withdrawn above the core. Test configurations differ primarily in the number of shim rods, and consequently the number of fuel rods included in the core. The critical condition was approached by incrementally and uniformly withdrawing CR boron from the core. Based on the analysis of the experimental data and numerical calculations, both experiments are considered acceptable as criticality safety benchmarks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uniformly Ordered Binary Decision Algorithm for Benchmark Experiment Correlations in Whisper Validation

When performing a validation exercise for determining the upper subcritical limit of a nuclear criticality safety application, an analyst should select and perform a statistical analysis on a population of benchmark experiments that are neutronically similar to the application. The size of this population should be sufficiently large such that the statistical analysis has a high degree of confidence that the bias plus bias uncertainty (calculational margin) has been accurately quantified. A complication arises because many benchmark experiments share common components, leading to correlations in their measured effective multiplication factors. Correlations between benchmark experiments within the population reduces its predictive power. This motivates the need for methods that consider benchmark experiment correlations and ensure adequate statistical significance of results. The Whisper code is a statistical analysis pack- age that incorporates nuclear data sensitivity coefficients from MCNP to assess benchmark experiment similarity and then performs an extreme-value analysis to estimate the bias plus bias uncertainty. The original methodology in Whisper does not consider the effect of benchmark experiment correlations when making this estimation, and this summary proposes the uniformly ordered binary decision algorithm to address this shortcoming. The original methodology in Whisper computes similarity coefficients ck for an application compared to all benchmark experiments in its library and develops weighting factors for a selected population proportional to the ck values. The methodology can be interpreted as statistically emulating a validation exercise for a particular application where the weighting factors may be viewed as the likelihood that an analyst would include a particular benchmark experiment within the population. The effective sample size of the population is the expected or mean number of benchmark experiments in the population. The uniformly ordered binary decision algorithm identifies clusters of correlated benchmark experiments within the population and then computes adjusted weighting factors based on the magnitude of the correlation coefficients within the cluster to compute a reduced effective sample size accounting for the lower information content because of correlations. Benchmark experiments within the cluster are ordered randomly with equal probability and probabilistic decisions are made as to whether a benchmark. experiment within the cluster should treated as redundant with a previous one; if two redundant benchmark experiments are included, then the conservative worst case bias plus bias uncertainty is used and the pair is counted as a single benchmark experiment in the population. Results are provided for HEU solutions in a research version of the Whisper software using benchmark experiment correlations provided by DICE, the Database for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). These show that there can be a significant increase in the bias plus bias uncertainty because the effective sample size is reduced, and therefore the algorithm, needing to meet sample size requirements, expands the benchmark experiment population by accepting less similar benchmark experiments that would have otherwise not been included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mobility assessment of the BCC and carbide phases in the C-Nb, C-U and Nb-U systems

Uranium carbides with refractory metal additions are considered for Gen IV nuclear reactors and nuclear thermal propulsion as fuels for their high-temperature and corrosion resistant properties. Understanding kinetic effects that dictate microstructural evolution during fabrication and operating conditions is essential to advance technological development of these fuels. This work presents the development of an atomic mobility database for C-Nb-U systems based off available experimental data supported with ab-initio methods. The mobility assessments and uncertainty quantification (using Markov chain Monte Carlo) were conducted in the Kawin software. Carbon diffusion is considered dominant, as metal diffusion is much slower, with niobium diffusion being even slower and rate limiting than uranium metal. We provide a comprehensive and self-consistent thermo-kinetic database that is validated by diffusion couple simulations through Kawin. In conclusion, this enables prediction of microstructural and phase evolution critical for the development and lifetime assessment of next generation nuclear fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MALDI Orbitrap Mass Spectrometry Profiling of Dysregulated Sulfoglycosphingolipids in Renal Cell Carcinoma Tissues

Matrix-assisted laser desorption/ionization coupled with Orbitrap mass spectrometry (MALDI-Orbitrap-MS) is used for the clinical study of patients with renal cell carcinoma (RCC), as the most common type of kidney cancer. Significant changes in sulfoglycosphingolipid abundances between tumor and autologous normal kidney tissues are observed. First, sulfoglycosphingolipid species in studied RCC samples are identified using high mass accuracy full scan and tandem mass spectra. Subsequently, optimization, method validation, and statistical evaluation of MALDI-MS data for 158 tissues of 80 patients are discussed. More than 120 sulfoglycosphingolipids containing one to five hexosyl units are identified in human RCC samples based on the systematic study of their fragmentation behavior. Many of them are recorded here for the first time. Multivariate data analysis (MDA) methods, i.e., unsupervised principal component analysis (PCA) and supervised orthogonal partial least square discriminant analysis (OPLS-DA), are used for the visualization of differences between normal and tumor samples to reveal the most up- and downregulated lipids in tumor tissues. Obtained results are closely correlated with MALDI mass spectrometry imaging (MSI) and histologic staining. Important steps of the present MALDI-Orbitrap-MS approach are also discussed, such as the selection of best matrix, correct normalization, validation for semiquantitative study, and problems with possible isobaric interferences on closed masses in full scan mass spectra. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ROBUST ONLINE MONITORING FOR CALIBRATION ASSESSMENT OF TRANSMITTERS AND INSTRUMENTATION

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. Specifically, the next generation of OLM technology is expected to include newly developed advanced algorithms that improve monitoring of sensor/system performance and enable the use of plant data to derive information that currently cannot be measured. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this paper, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation – fault detection and selection of acceptance criteria • Virtual sensing – signal value prediction and acceptance criteria • Response-time assessment – fault detection and acceptance criteria selection A GP-based uncertainty quantification (UQ) method previously developed for UQ in OLM, was adapted for use in sensor-fault detection and virtual sensing. For signal validation, the various components to the OLM residual (which is computed using an AAKR model) were explicitly defined and modeled using a GP. Evaluation was conducted using flow loop data from multiple sources. Results using experimental data from laboratory-scale flow loops indicate that the approach, while capable of detecting sensor drift, may be incapable of discriminating between sensor drift and model inadequacy. This may be due to a simplification applied in the initial modeling, where the sensor degradation is assumed to be stationary. In the case of virtual sensors, the GP model was used in a predictive mode to estimate the correct sensor reading for sensors that may have failed. Results have indicated the viability of using this approach for virtual sensing. However, the GP model has proven to be computationally expensive, and so alternative algorithms for virtual sensing are being evaluated. Finally, automated approaches to performing noise analysis for extracting sensor response time were developed. Evaluation of this technique using laboratory-scale data indicates that it compares well with manual techniques previously used for noise analysis. Moreover, the automated and manual approaches for noise analysis also compare well with the current “gold standard”, hydraulic ramp testing, for response time monitoring. Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

calibration interval extension↗

Nucleon-induced inelastic scattering with statistical strength functions and the ECIS direct reaction code

Modern theoretical descriptions of inelastic scattering make use of multi-step direct reaction approaches together with transition potentials obtained from sophisticated nuclear structure models. Here we demonstrate how the complexity of such calculations can be reduced to permit simpler ones, also using the ECIS code, but providing an almost equally precise alternative to a much more detailed calculation. We have studied the transition form factors within the random phase approximation (RPA), where these are obtained as linear combinations of particle–hole states. At moderate to high excitation energies, where interference effects tend to disappear, we have proposed an independent particle–hole formalism in which particle–hole states are spread in energy with an appropriate strength function obtained from the RPA. The effects of more complex modes, such as 2p–2h ones, are simulated with widths calculated in a semi-classical context. In this work, we verify the validity of our approximations for pre-equilibrium proton-induced reactions on 90 Zr target. Our calculations provide a good description of the reaction data and point toward a simplification of the description of nucleon-induced reactions based on averages of microscopic details of the projectile–target interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine learning for ultrasonic nondestructive examination of welding defects: A systematic review

Recent years have seen a substantial increase in the application of machine learning (ML) for automated analysis of nondestructive examination (NDE) data. One of the applications of interest is the use of ML for the analysis of data from in-service inspection of welds in nuclear power and other industries. These types of inspections are performed in accordance with criteria described in the ASME Boiler and Pressure Vessel Code and require the use of reliable NDE techniques. The rapid growth in ML methods and the diversity of possible approaches indicate a need to assess the current capabilities of ML and automated data analysis for NDE and identify any gaps or shortcomings in current ML technologies as applied to the automated analysis of NDE data. In particular, there is a need to determine the impact of ML on the NDE reliability. This paper discusses the findings from a literature survey on the current state of ML for the automated analysis of data from ultrasonic NDE of weld flaws. It discusses an overview of ultrasonic NDE as used for weld inspections in nuclear power and other industries. Herein, data sets and ML models used in the literature are summarized, along with a generally applicable workflow for ML. Findings on the capabilities, limitations and potential gaps in feature selection, data selection, and ML model optimization are discussed. The paper identified several needs for quantifying and validating the performance of ML methods for ultrasonic NDE, including the need for common data sets.

36 MATERIALS SCIENCE↗

Alterations in the nuclear proteome of HIV-1 infected T-cells

Virus infection of a cell involves the appropriation of host factors and the innate defensive response of the cell. The identification of proteins critical for virus replication may lead to the development of novel, cell-based inhibitors. In this study we mapped the changes in T-cell nuclei during human immunodeficiency virus type 1 (HIV-1) at 20 hpi. Using a stringent data threshold, a total of 13 and 38 unique proteins were identified in infected and uninfected cells, respectively, across all biological replicates. An additional 15 proteins were found to be differentially regulated between infected and control nuclei. STRING analysis identified four clusters of protein–protein interactions in the data set related to nuclear architecture, RNA regulation, cell division, and cell homeostasis. Immunoblot analysis confirmed the differential expression of several proteins in both C8166-45 and Jurkat E6-1 T-cells. These data provide a map of the response in host cell nuclei upon HIV-1 infection. - Highlights: • We identify changes in the expression of nuclear proteins during HIV-1 infection. • 163 nuclear proteins were found differentially regulated during HIV-1 infection. • Bioinformatic analysis identified several nuclear pathways altered by HIV infection. • Candidate factors were validated in two independent cell lines.

60 APPLIED LIFE SCIENCES↗

Data acquisition and processing system of the electron cyclotron emission imaging system of the KSTAR tokamak

A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the large data production and flow. The system design is based on the layered structure scalable to the future extension to accommodate increasing data demands. Software architecture that allows a web-based monitoring of the operation status, remote experiment, and data analysis is discussed. The operating software will help machine operators and users validate the acquired data promptly, prepare next discharge, and enhance the experiment performance and data analysis in a distributed environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark Calculation for Turkey Point Unit 3 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

Benchmark calculations were performed for Turkey Point Unit 3 cycles 1–3 to validate the SCALE 6.3/Polaris–PARCS v3.4.2 code with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used in evaluating the SCALE/Polaris–PARCS code package’s uncertainties for pressurized water reactor physics analysis. That future analysis will include key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. The present document details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided with respect to the input and output files produced for the benchmark calculations. The benchmark results are summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Calculation for Surry Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

The benchmark calculations were performed for Surry Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–Purdue Advanced Reactor Core Simulator (PARCS) v3.4.2 with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Current status of MCNP6 as a simulation tool useful for space and accelerator applications

For the past several years, a major effort has been undertaken at Los Alamos National Laboratory (LANL) to develop the transport code MCNP6, the latest LANL Monte-Carlo transport code representing a merger and improvement of MCNP5 and MCNPX. We emphasize a description of the latest developments of MCNP6 at higher energies to improve its reliability in calculating rare-isotope production, high-energy cumulative particle production, and a gamut of reactions important for space-radiation shielding, cosmic-ray propagation, and accelerator applications. We present several examples of validation and verification of MCNP6 compared to a wide variety of intermediate- and high-energy experimental data on reactions induced by photons, mesons, nucleons, and nuclei at energies from tens of MeV to about 1 TeV/nucleon, and compare to results from other modern simulation tools.

ACCELERATORS↗

Jupiter: A Proposed Benchmark for Lead Void Worth with Plutonium

In the summer of 2017, a series of measurements were performed at the National Criticality Experiments Research Center (NCERC) in collaboration with the Japanese Atomic Energy Agency (JAEA) to measure the reactivity worth of voids in an array of lead and plutonium. This experiment, called Jupiter, measured multiple configurations of an array of aluminum boxes containing plutonium, aluminum, and lead plates. For some configurations, a selection of the lead interstitial plates were swapped with aluminum spacer frames to create “voids” in the lead interstitial material. Comparing the excess reactivity of the systems provides an empirical value of the lead void reactivity worth. These measurements were part of a larger collaboration to measure lead void reactivity worth with multiple nuclear material types and enrichments. This included other measurement series with both highly-enriched uranium (HEU), and a mixture of HEU and natural uranium to simulate low-enriched uranium (LEU). These data sets will be useful to the JAEA for a potential lead-bismuth cooled accelerator driven system. Additionally, there are not very many benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook sensitive to lead cross sections. Given that lead is widely used as a radiation shield and is part of new reactor designs, having more benchmarks in the ICSBEP handbook to better support cross section validation is important. Additional integral experiments could also aid in determining whether improvements have been made in new lead cross section evaluations. A benchmark evaluation for this experiment is being proposed in order to help fulfill these needs. Such evaluations contain both measured data, results from detailed transport code models, and analyses of the uncertainties associated with each. Examples of these uncertainties include the uncertainty in the measured excess reactivity, the composition of components, or their positioning within the model. This means it is easier to make comparisons between the measured and simulated data and better understand where improvements can be made to nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental validation of a high fidelity Monte Carlo neutron transport model of the MIT graphite exponential pile

High-fidelity modeling and simulation were performed for the MIT graphite exponential pile (MGEP) using Monte Carlo neutron transport codes OpenMC and MCNP, and the results were validated by experimental data. The MGEP is being used as the test bed for the design of an autonomous control system for the pile's neutron flux distribution. The main contribution of this work is to generate the training data sets of neutron flux distributions with different locations of control rods that perturb the neutron flux profiles. First, code -to-code cross verification between OpenMC and MCNP was performed to ensure consistency of the numerical modeling within statistical uncertainties. To validate the accuracy of this high-fidelity model, a series of neutron flux measurements were conducted using a Helium-3 (He-3) neutron detector on a mobile platform that is placed inside the pile. Second, the neutron flux profiles were measured in four vertical layers of interest, and compared to the corresponding simulation results. The comparison results shows that the root mean square error is less than 2.5% in the two upper layers, and less than 4.5% in all four measured layers. Here the results validated the accuracy of the modeling and simulation. Finally, the relative change of the neutron flux profiles from moving control rods was analyzed, which identified the layer that has the best sensitivity regarding the control rods movements. Thus, this work identified and provided training data sets of both simulated and experimental neutron flux profiles in the most sensitive layer, paving the path forward to the real-time experimental demonstration of the autonomous control system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Intelligent Experiments through Real-Time AI: Fast Data Processing and Autonomous Detector Control for High-Energy Nuclear Experiments

The aim of this project is to develop software and hardware for fast real-time data processing and autonomous detector control and calibration for the sPHENIX and the future EIC experiments. Below summarizes Georgia Tech team efforts in the past year: 1. We developed a real-time clustering algorithm and FPGA-based pipeline architecture for processing fired pixel data from ALPIDE sensors in sPHENIX experiments. Our Columnar Clustering Co-Design introduces a hardware-aware, stream-friendly approach that segments pixel data by column pairs using a Column Pair Clustering (CPC) strategy, followed by Cluster Stitching to merge adjacent subclusters. Implemented in Vitis HLS, the pipeline comprises five stages—read-in, subclustering, stitching, analysis, and write-out—connected by tagged HLS streams with custom end-of-event signaling for robust synchronization. We designed a pipelined dataflow model optimized for throughput, low latency, and minimal buffering, enabling scalable clustering across events of arbitrary size. Our system maintains spatial precision via center-of-mass and shape key extraction and efficiently handles edge cases such as fragmented or nested clusters. Compared against DBSCAN in both software and hardware, our approach demonstrates competitive performance under FPGA constraints. 2. We also conducted a comprehensive algorithm-to-hardware co-design of connected component analysis tailored for sPHENIX experiments, focusing on real-time, low-latency processing using FPGAs and High-Level Synthesis (HLS). Starting from a Python-based particle tracking pipeline, the team translated the core logic—graph traversal via DFS and Union-Find—into an HLS-compatible C++ model, replacing dynamic memory and recursion with static arrays and pipelined control flow. The final design includes a fully streamed and dataflow-compatible Union-Find kernel optimized across five iterations, incorporating loop pipelining, array partitioning, AXI/FIFO interface tuning, and function flattening. Experimental results show up to 14.8× speedup over the CPU baseline, reducing per-graph latency to 1.58 μs and demonstrating strong resource efficiency with only ~7k LUTs and zero BRAM usage. The design maintains functional correctness against the Python reference using a Python-based C-simulation framework and Mean Squared Error metrics. This work validates the potential of HLS-driven FPGA designs for edge-level HEP data acquisition, laying a scalable foundation for future integration with real-time detector pipelines and multi-graph processing systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Set-up for the Study of Chemical Fractionation and Aerosol Dynamics

Experimental investigations of chemical fractionation/phase partition and aerosol dynamics in high-temperature environment were reviewed and discussed. Particle composition and size distribution are the key data for aerosol dynamics predictive model and simulation. However, there were no particle size distribution available from the previous works. Nucleation, condensation, and coagulation are three key physical processes driving the fractionation or phase partition thereby the aerosol dynamics. A new approach was proposed to experimentally observe fractionation/phase partition and provide data for validating the predictive model for aerosol dynamics in the simulation of bomb debris formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and performance testing of a novel far field Gamma system to assay radioactive waste in 400 and 200 litre drums - 15339

A Far Field Gamma ray Measurement system has been developed for measuring and assaying both 400 and 200 litre waste drums with a wide range of activity at nuclear power stations. These include radioactive waste drums with surface dose-rates of less than 2 mSv/h (200 mrem/h) and, at the higher range of activity, 400 litre drums with surface dose-rates of up to 50 mSv/h (5 rem/h). The assay system incorporates an electro-mechanically cooled high purity Germanium profile detector and advanced digital spectroscopic analysis electronics. A novel optimised conical-trapezoidal collimator has been incorporated to reduce the effect of the radioactive background in addition to the conventional detector lead shield with tin and copper graded lining to reduce the effect of lead X-rays. Two features have been incorporated to reduce detector dead time and maintain detector resolution when measuring high activity drums. The first is the inclusion of two automated tungsten filters of different thickness as an integral part of the detector collimator. The filters are used in conjunction with an automated rail system on which the detector platform is mounted. The detector can be positioned at different distances from the drum surface in order to reduce detector dead time. The deployment of the filters and the adjustment of the drum - detector position are automatically controlled based on a user defined dose-rate limit table. The data is provided by two Geiger-Muller dose-rate detectors, which are used to measure the drum surface dose-rate. This data is subsequently used to adjust the detector position and in cases of higher dose-rate deploy one or other of the tungsten filters. The drum rotation platform incorporates a load cell to determine drum weight and hence the drum density. This information is used to calculate an attenuation correction based on the assumption of uniform drum density and uniform distribution of activity within the drum. Where the waste drums have a more complicated and known regular internal structure, such as a small radioactive region surrounded by an annulus of shielding material, the analysis algorithms incorporated into the far field geometry and attenuation correction spectroscopic data analysis code are able to make a more accurate determination of drum activity than would be possible assuming a completely uniform drum. The detector energy and efficiency calibration is achieved using a point source with multiple gamma ray energy peaks. The response of the high purity Germanium detector is also modelled using the Monte Carlo Neutron Photon code and the model is benchmarked using the measured point source calibration data. The performance of the instrument has been determined for a range of uniform density matrix drums containing a set of Eu-152 line or rod sources located in re-entrant tubes positioned on an equal volume basis. When rotated, the test drums with volume distributed line sources simulate waste drums of different density each with a uniformly distributed radioactive source. The measurements have been validated using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗