Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Spatially resolved strain measurements in Mo-alloy micropillars by differential aperture x-ray microscopy.

Spatially resolved strain distributions in the NiAl matrix and the {approx}550-1000 nm Mo fibers of a NiAl-Mo eutectic were investigated by microbeam x-ray diffraction. Position sensitive d-spacings for the individual phases were obtained from spatially resolved and energy-resolved Laue patterns. For embedded Mo fibers, the measured elastic strain is consistent with the predicted thermal mismatch strain between the NiAl and Mo phases. However, when the NiAl matrix is etched back to expose Mo micropillars, the d-spacing increases to that of unconstrained Mo, indicating release of the compressive residual strain in the Mo fibers.

36 MATERIALS SCIENCE↗

Laser Patterning of Diamond. Part I. Characterization of Surface Morphology

As the use of diamond as a material for electronic and research applications increases, methods of patterning diamond will be required. In this work, single- and polycrystalline synthetic diamond samples were exposed to laser beams of different energies, wavelengths, and pulse durations. The effects of this exposure were characterized using optical microscopy, scanning electron microscopy, and atomic force microscopy. The threshold ablation energy density for 266 nm radiation with {approx} 30 ps pulse duration was measured to be {approx} 14 J/cm{sup 2}. The threshold for {approx} 10 ns pulses at the same wavelength was similar, but the ablated area displayed larger surface damage. The surface damage and the threshold energy increase significantly for 532 and 1064 nm radiations. Ablation performed using 213 nm radiation produced the most uniform surface. Changes in the ablated surface are presented in detail.

43 PARTICLE ACCELERATORS↗

{sup 3}He alternative technologies: 1. Application of neutron image plate detector for powder diffractometry

Neutron image plate was used for recording powder diffraction pattern from a polycrystalline Fe rod, mounted on the High Q Diffractometer at Dhruva reactor and using neutron beam of {lambda}= 0.783 A and {Phi}= 3 x 10{sup 5} n/cm{sup 2}/sec. The Bragg peaks were sharp and well resolved. The overall resolution ({Delta}2{theta}/2{theta}) value was found be {approx}0.025.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially addressable design of gradient index structures through spatial light modulator based holographic lithography

In this paper, we present an achievable gradient refractive index in bi-continuous holographic structures that are formed through five-beam interference. We further present a theoretic approach for the realization of gradient index devices by engineering the phases of the interfering beams with a pixelated spatial light modulator. As an example, the design concept of a gradient index Luneburg lens is verified through full-wave electromagnetic simulations. These five beams with desired phases can be generated through programming gray level super-cells in a diffractive spatial light modulator. As a proof-of-concept, gradient index structures are demonstrated using synthesized and gradient phase patterns displayed in the spatial light modulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Both antireflection and superhydrophobicity structures achieved by direct laser interference nanomanufacturing

Inspired by nature, a number of techniques have been developed to fabricate the bionic structures of lotus leaves and moth eyes in order to realize the extraordinary functions of self-cleaning and antireflection. Compared with the existing technologies, we present a straightforward method to fabricate well-defined micro and nano artificial bio-structures in this work. The proposed method of direct laser interference nanomanufacturing (DLIN) takes a significant advantage of high efficiency as only a single technological procedure is needed without pretreatment, mask, and pattern transfer processes. Meanwhile, the corresponding structures show both antireflection and superhydrophobicity properties simultaneously. The developed four-beam nanosecond laser interference system configuring the TE-TE-TE-TE and TE-TE-TE-TM polarization modes was set up to generate periodic micro cone and hole structures with a huge number of nano features on the surface. The theoretical and experimental results have shown that the periodic microcone structure exhibits excellent properties with both a high contact angle (CA = 156.3°) and low omnidirectional reflectance (5.9–15.4%). Thus, DLIN is a novel and promising method suitable for mass production of self-cleaning and antireflection surface structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic properties of square Py nanowires: Irradiation dose and geometry dependence

Arrays of ferromagnetic patterned nanostructures with single particle lateral dimensions between 160 nm and 400 nm were created by electron-beam lithography. The fourfold particles with rectangular-shaped walls around a square open area were produced from permalloy. Their magnetic properties were measured using the longitudinal magneto-optical Kerr effect. The article reports about the angle-dependent coercive fields and the influence of the e-beam radiation dose on sample shapes. It is shown that a broad range of radiation dose intensities enables reliable creation of nanostructures with parameters relevant for the desired magnetization reversal scenario. The experimental results are finally compared with micromagnetic simulations to explain the findings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Symmetry of piezoelectric (1–x)Pb(Mg 1/3 Nb 2/3 )O₃-xPbTiO₃ (x=0.31) single crystal at different length scales in the morphotropic phase boundary region

We use probes of three different length scales to examine symmetry of (1–x)Pb(Mg 1/3 Nb 2/3 )O₃-xPbTiO₃ (PMN-xPT) single crystals in the morphotropic phase boundary (MPB) region at composition x = 0.31 (PMN-31% PT). On the macroscopic scale, x-ray diffraction (XRD) shows a mixture of strong and weak diffraction peaks of different widths. The closest match to XRD peak data is made with monoclinic Pm (M C ) symmetry. On the local scale of a few nanometers, convergent beam electron diffraction (CBED) studies, with a 1.6-nm electron probe, reveal no obvious symmetry. These CBED experimental patterns can be approximately matched with simulations based on monoclinic symmetry, which suggests locally distorted monoclinic structure. A monoclinic Cm (M A or M B )-like symmetry could also be obtained from certain regions of the crystal by using a larger electron probe size of several tens of nanometers in diameter. Thus the monoclinic symmetry of single crystal PMN-31%PT is developed only in parts of the crystal by averaging over locally distorted structure on the scale of few tens of nanometers. The macroscopic symmetry observed by XRD is a result of averaging from the local structure in PMN-31%PT single crystal. The lack of local symmetry at a few nanometers scale suggests that the polarization switching results from a change in local displacements, which are not restricted to specific symmetry planes or directions.

Kim, Kyou-Hyun↗

A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.

36 MATERIALS SCIENCE↗

SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported.

60 APPLIED LIFE SCIENCES↗

Ultrasonic simulation of MSBLS multipath fading for orbiter landing configuration

The on-shuttle antenna pattern of the MSBLS receiver, and the azimuth and elevation beamwidths were simulated by their corresponding ultrasonic transducer beams. The scanning rate for the azimuth and elevation beams was 1.75 degrees/second. The results were adjusted for full-scale maximum sinusoidal scan rates of 691 and 377 deg/sec for AZ and EL respectively. The rain drops were simulated by air bubbles, with a similar size distribution, in water. The rain volume was created along a part of the propagation path, and not on the runway, because it was found difficult to avoid an accumulation of bubbles on the runway surface and surroundings simulated by the model surface. Multipath fading from the ground, and its possible degrading effect on the orbiter received beam shape and the associated landing guidance parameters is discussed.

Hayre, H. S.↗

Most desirable terrain, e.g., flat vs valley location, part 5.1B

Ground reflections which are similar for all (Yagi) elements of a phased array and change the radiation pattern of the single elements are discussed. This consequently yields a change of the radiation pattern of the entire array. It is assumed that the radiation pattern of a Yagi antenna can be treated in a good approximation for the present purpose, similar to the pattern of a single dipole, if one confines to radiation angles which are roughly perpendicular to the main beam of the Yagi antenna.

Rottger, J.↗

Near-field testing of the 30 GHz TRW proof-of-concept multibeam antenna

Near-field testing was conducted on the 30 GHz TRW proof-of-concept (POC) Multibeam Antenna (MBA). The TRW POC MBA is a dual offset Cassegrain reflector system using a 2.7 m main reflector. This configuration was selected to assess the ability to create both multiple fixed and scanned spot beams. The POC configuration investigated frequency reuse via spatial separation of beams, polarization selectivity and time division multiple access scanning at 30 GHz. Measurements of directivity, sidelobe level, and pattern were made at NASA Lewis Research Center's Near-Field Antenna Test Facility. Presented in this paper are complete results of these measurements. Included is a detailed discussion of all testing procedures and parameters. Results of additional testing used to evaluate diffraction effects of the subreflector and distortions of the main reflector are also presented.

Kunath, R. R., Jr.↗

Retroreflection Focusing Schlieren System

A retroreflective type focusing schlieren system which permits the light source to be positioned on the optic side of the system is introduced. The system includes an extended light source, as opposed to a point source, located adjacent to a beam splitter which projects light through the flow field onto a reflecting grating in the form of a grid which generates sheets of light that are directed back through the flow field and the beam splitter onto a primary lens behind which is located a cut-off grid having a grid pattern which corresponds to the grid pattern of the reflecting grating. The cut-off grid is adjustably positioned behind the primary lens and an image plane for imaging the turbulence is adjustably located behind the cut-off grid.

Heineck, James T.↗

Characterization of 4H <000-1> Silicon Carbide Films Grown by Solvent-Laser Heated Floating Zone

Commercially available bulk silicon carbide (SiC) has a high number (>2000/sq cm) of screw dislocations (SD) that have been linked to degradation of high-field power device electrical performance properties. Researchers at the NASA Glenn Research Center have proposed a method to mass-produce significantly higher quality bulk SiC. In order for this bulk growth method to become reality, growth of long single crystal SiC fibers must first be achieved. Therefore, a new growth method, Solvent-Laser Heated Floating Zone (Solvent-LHFZ), has been implemented. While some of the initial Solvent-LHFZ results have recently been reported, this paper focuses on further characterization of grown crystals and their growth fronts. To this end, secondary ion mass spectroscopy (SIMS) depth profiles, cross section analysis by focused ion beam (FIB) milling and mechanical polishing, and orientation and structural characterization by x-ray transmission Laue diffraction patterns and x-ray topography were used. Results paint a picture of a chaotic growth front, with Fe incorporation dependant on C concentration.

Woodworth, Andrew, A↗

Design tradeoff study for reflector antenna systems for the shuttle imaging microwave system

A general tradeoff is made of the symmetric Cassegrain antenna with regard to the possibility of meeting a 90% beam efficiency. The effects of aperture taper and blockage are calculated using an adjustable sidelobe circular distribution. Numerical integration is used. For the feed spillover calculation, a low sidelobe symmetric feed pattern is used with the equivalent parabola and numerical integration. Reflector cross polarization is calculated using double numerical integration. Reflector back lobes are estimated from radiation pattern envelopes of commercial common carrier dish antennas. The curves allow a range of f/D to be determined for a specified edge taper and blockage diameter ratio, and with a table of Cassegrain parameters, a range of possible designs that meet the 90% beam efficiency is obtained. It is shown that the feed and reflector design and implementation must be carefully done.

Hansen, R. C.↗

Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography

Purpose: The purpose of this work is to improve the noise power spectrum (NPS), and thus the detective quantum efficiency (DQE), of computed radiography (CR) images by correcting for spatial gain variations specific to individual imaging plates. CR devices have not traditionally employed gain-map corrections, unlike the case with flat-panel detectors, because of the multiplicity of plates used with each reader. The lack of gain-map correction has limited the DQE(f) at higher exposures with CR. This current work describes a feasible solution to generating plate-specific gain maps. Methods: Ten high-exposure open field images were taken with an RQA5 spectrum, using a sixth generation CR plate suspended in air without a cassette. Image values were converted to exposure, the plates registered using fiducial dots on the plate, the ten images averaged, and then high-pass filtered to remove low frequency contributions from field inhomogeneity. A gain-map was then produced by converting all pixel values in the average into fractions with mean of one. The resultant gain-map of the plate was used to normalize subsequent single images to correct for spatial gain fluctuation. To validate performance, the normalized NPS (NNPS) for all images was calculated both with and without the gain-map correction. Variations in the quality of correction due to exposure levels, beam voltage/spectrum, CR reader used, and registration were investigated. Results: The NNPS with plate-specific gain-map correction showed improvement over the noncorrected case over the range of frequencies from 0.15 to 2.5 mm{sup -1}. At high exposure (40 mR), NNPS was 50%-90% better with gain-map correction than without. A small further improvement in NNPS was seen from carefully registering the gain-map with subsequent images using small fiducial dots, because of slight misregistration during scanning. Further improvement was seen in the NNPS from scaling the gain map about the mean to account for different beam spectra. Conclusions: This study demonstrates that a simple gain-map can be used to correct for the fixed-pattern noise in a given plate and thus improve the DQE of CR imaging. Such a method could easily be implemented by manufacturers because each plate has a unique bar code and the gain-map for all plates associated with a reader could be stored for future retrieval. These experiments indicated that an improvement in NPS (and hence, DQE) is possible, depending on exposure level, over a wide range of frequencies with this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery

Purpose: To efficiently deliver respiratory-gated radiation during synchrotron-based pulsed heavy-ion radiotherapy, a novel respiratory guidance method combining a personalized audio-visual biofeedback (BFB) system, breath hold (BH), and synchrotron-based gating was designed to help patients synchronize their respiratory patterns with synchrotron pulses and to overcome typical limitations such as low efficiency, residual motion, and discomfort. Methods: In-house software was developed to acquire body surface marker positions and display BFB, gating signals, and real-time beam profiles on a LED screen. Patients were prompted to perform short BHs or short deep breath holds (SDBH) with the aid of BFB following a personalized standard BH/SDBH (stBH/stSDBH) guiding curve or their own representative BH/SDBH (reBH/reSDBH) guiding curve. A practical simulation was performed for a group of 15 volunteers to evaluate the feasibility and effectiveness of this method. Effective dose rates (EDRs), mean absolute errors between the guiding curves and the measured curves, and mean absolute deviations of the measured curves were obtained within 10%–50% duty cycles (DCs) that were synchronized with the synchrotron’s flat-top phase. Results: All maneuvers for an individual volunteer took approximately half an hour, and no one experienced discomfort during the maneuvers. Using the respiratory guidance methods, the magnitude of residual motion was almost ten times less than during nongated irradiation, and increases in the average effective dose rate by factors of 2.39–4.65, 2.39–4.59, 1.73–3.50, and 1.73–3.55 for the stBH, reBH, stSDBH, and reSDBH guiding maneuvers, respectively, were observed in contrast with conventional free breathing-based gated irradiation, depending on the respiratory-gated duty cycle settings. Conclusions: The proposed respiratory guidance method with personalized BFB was confirmed to be feasible in a group of volunteers. Increased effective dose rate and improved overall treatment precision were observed compared to conventional free breathing-based, respiratory-gated irradiation. Because breathing guidance curves could be established based on the respective average respiratory period and amplitude for each patient, it may be easier for patients to cooperate using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of faceted nanopores in magnesium

In this paper, using high resolution transmission electron microscopy, we showed the fabrication of faceted nanopores with various shapes in magnesium by focused electron beam (e-beam). The characteristics of nanopore shapes and the crystallographic planes corresponding to the edges of the nanopores were discussed in detail. Interestingly, by manipulating the e-beam (e.g., irradiation direction and duration), the nanopore shape and size could be effectively controlled along different directions. Our results provide important insight into the nanopore patterning in metallic materials and are of fundamental importance concerning the relevant applications, such as nanopore-based sensor, etc.

36 MATERIALS SCIENCE↗