Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

SU-E-J-17: A Study of Accelerator-Induced Cerenkov Radiation as a Beam Diagnostic and Dosimetry Tool

Purpose: To investigate accelerator-induced Cerenkov radiation imaging as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams in a water phantom was imaged using a camera system comprised of a high-sensitivity thermoelectrically-cooled CCD camera coupled to a large aperture (f/0.75) objective lens with 16:1 magnification. This large format lens allows a significant amount of the available Cerenkov light to be collected and focused onto the CCD camera to form the image. Preliminary images, obtained with 6 MV photon beams, used an unshielded camera mounted horizontally with the beam normal to the water surface, and confirmed the detection of Cerenkov radiation. Several improvements were subsequently made including the addition of radiation shielding around the camera, and altering of the beam and camera angles to give a more favorable geometry for Cerenkov light collection. A detailed study was then undertaken over a range of electron and photon beam energies and dose rates to investigate the possibility of using this technique for beam diagnostics and dosimetry. Results: A series of images were obtained at a fixed dose rate over a range of electron energies from 6 to 20 MeV. The location of maximum intensity was found to vary linearly with the energy of the beam. A linear relationship was also found between the light observed from a fixed point on the central axis and the dose rate for both photon and electron beams. Conclusion: We have found that the analysis of images of beam-induced Cerenkov light in a water phantom has potential for use as a beam diagnostic and medical dosimetry tool. Our future goals include the calibration of the light output in terms of radiation dose and development of a tomographic system for 3D Cerenkov imaging in water phantoms and other media.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-37: Combining Proton Radiography and X-Ray CT Information to Better Estimate Relative Proton Stopping Power in a Clinical Environment

Purpose: In standard proton therapy clinical practice, proton stopping power uncertainties are in the order of 3.5%, which affects the ability of placing the proton Bragg peak at the edge of the tumor. The innovating idea of this project is to approach the uncertainty problem in RSP by using combined information from X-ray CT and proton radiography along a few beam angles. In addition, this project aims to quantify the systematic error introduced by the theoretical models (Janni, ICRU49, Bischel) for proton stopping power in media. Methods: A 3D phantom of 36 cm3 composed of 9 materials randomly placed is created. Measured RSP values are obtained using a Gammex phantom with a proton beam. Theoretical RSP values are calculated with Beth-Block equation in combination with three databases (Janni, ICRU49 and Bischel). Clinical RSP errors are simulated by introducing a systematic (1.5%, 2.5%, 3.5%) and a random error (+/−0.5%) to the theoretical RSP. A ray-tracing algorithm uses each of these RSP tables to calculate energy loss for proton crossing the phantom through various directions. For each direction, gradient descent (GD) method is done on the clinical RSP table to minimize the residual energy difference between the simulation with clinical RSP and with theoretical RSP. The possibility of a systematic material dependent error is investigated by comparing measured RSP to theoretical RSP as calculated from the three models. Results: Using 10,000 iterations on GD algorithm, RSP differences between theoretical values and clinical RSP have converged (<1%) for each error introduced. Results produced with ICRU49 have the smallest average difference (0.021%) to the measured RSP. Janni (1.168%) and Bischel (−0.372%) database shows larger systematic errors. Conclusion: Based on these results, ray-tracing optimisation using information from proton radiography and X-ray CT demonstrates a potential to improve the proton range accuracy in a clinical environment.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-47: Development of a High-Precision, Image-Guided Radiotherapy, Multi- Purpose Radiation Isocenter Quality-Assurance Calibration and Checking System

Purpose: To develop a system that can define the radiation isocenter and correlate this information with couch coordinates, laser alignment, optical distance indicator (ODI) settings, optical tracking system (OTS) calibrations, and mechanical isocenter walkout. Methods: Our team developed a multi-adapter, multi-purpose quality assurance (QA) and calibration device that uses an electronic portal imaging device (EPID) and in-house image-processing software to define the radiation isocenter, thereby allowing linear accelerator (Linac) components to be verified and calibrated. Motivated by the concept that each Linac component related to patient setup for image-guided radiotherapy based on cone-beam CT should be calibrated with respect to the radiation isocenter, we designed multiple concentric adapters of various materials and shapes to meet the needs of MV and KV radiation isocenter definition, laser alignment, and OTS calibration. The phantom's ability to accurately define the radiation isocenter was validated on 4 Elekta Linacs using a commercial ball bearing (BB) phantom as a reference. Radiation isocenter walkout and the accuracy of couch coordinates, ODI, and OTS were then quantified with the device. Results: The device was able to define the radiation isocenter within 0.3 mm. Radiation isocenter walkout was within ±1 mm at 4 cardinal angles. By switching adapters, we identified that the accuracy of the couch position digital readout, ODI, OTS, and mechanical isocenter walkout was within sub-mm. Conclusion: This multi-adapter, multi-purpose isocenter phantom can be used to accurately define the radiation isocenter and represents a potential paradigm shift in Linac QA. Moreover, multiple concentric adapters allowed for sub-mm accuracy for the other relevant components. This intuitive and user-friendly design is currently patent pending.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-73: Generation of Volumetric Images with a Respiratory Motion Model Based On An External Surrogate Signal

Purpose: Respiratory motion during radiotherapy treatment can differ significantly from motion observed during imaging for treatment planning. Our goal is to use an initial 4DCT scan and the trace of an external surrogate marker to generate 3D images of patient anatomy during treatment. Methods: Deformable image registration is performed on images from an initial 4DCT scan. The deformation vectors are used to develop a patient-specific linear relationship between the motion of each voxel and the trajectory of an external surrogate signal. Correlations in motion are taken into account with principal component analysis, reducing the number of free parameters. This model is tested with digital phantoms reproducing the breathing patterns of ten measured patient tumor trajectories, using five seconds of data to develop the model and the subsequent thirty seconds to test its predictions. The model is also tested with a breathing physical anthropomorphic phantom programmed to reproduce a patient breathing pattern. Results: The error (mean absolute, 95th percentile) over 30 seconds in the predicted tumor centroid position ranged from (0.8, 1.3) mm to (2.2, 4.3) mm for the ten patient breathing patterns. The model reproduced changes in both phase and amplitude of the breathing pattern. Agreement between prediction and truth over the entire image was confirmed by assessing the global voxel intensity RMS error. In the physical phantom, the error in the tumor centroid position was less than 1 mm for all images. Conclusion: We are able to reconstruct 3D images of patient anatomy with a model correlating internal respiratory motion with motion of an external surrogate marker, reproducing the expected tumor centroid position with an average accuracy of 1.4 mm. The images generated by this model could be used to improve dose calculations for treatment planning and delivered dose estimates. This work was partially funded by a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-J-207: Assessing the Validity of 4D-CT Based Target Volumes and Free Breathing CBCT Localization in Lung Stereotactic Ablative Radiation Therapy (SABR)

Purpose: Four-dimensional-computed-tomography(4D-CT) imaging for target-volume delineation and cone-beam-tomography(CBCT) for treatment localization are widely utilized in lung-SABR.Aim of this study was to perform a quantitative-assessment and inter-comparison of Internal-targetvolumes( ITV) drawn on various phases of breathing-cycle 4D-CT-scans, Maximum-intensity-projection(MIP), average-intensity-projection(AIP)and static CT-scans of lung-motion-phantom to simulate lung-SABR patient geometry. We also analyzed and compared the ITVs drawn on freebreathing- CBCT. Materials and Methods: 4D-CT-scans were acquired on Philips big-bore 16slice CT and Bellows-respiratory monitoring-system using retrospective phase-binning method. Each respiratory cycle divided into 10-phases. Quasar-Phantom with lung-inserts and 3cm-diameter nylonball to simulate tumor and was placed on respiratory-motion-platform for 4D-CT and CBCT-acquisition. Amplitudes of motions: 0.5,1.0,2.0,3.0cm in superior-inferior direction with breathing-cycle time of 6,5,4,6sec, respectively used.4D-CTs with 10-phases(0%to90%)for each excursion-set and 3D-CT for static-phantom exported to iPlan treatment-planningsystem( TPS).Tumor-volumes delineated in all phases of 4D-CT, MIP,AIP,CBCT scans using fixed-HU-threshold(−500to1000)values automatically.For each 4D-dataset ITV obtained by unifying the tumorcontours on all phases.CBCT-ITV-volumes were drawn in Eclipse-TPS. Results: Mean volume of tumor contours for all phases compared with static 3D-CT were 0.62±0.08%, 1.67±0.26%, 4.77±0.54% and 9.27±1.23% for 0.5cm,1cm,2cm,3cm excursions respectively. Differences of mean Union-ITV with MIP-ITV were close(≤2.4%).Mean Union-ITV from expected-theoretical values differed from −4.9% to 3.8%.Union-ITV and MIP-ITV were closer within 2.3%. AIP-ITVs were underestimated from 14 to 32% compared to union-ITV for all motion datasets. Differences of −5.9% to −44% and −5% to 6.7% for CBCT-ITV from MIP-ITV and AIP-ITV respectively.Motion excursions and centroid positions were within 2mm for 4D-CT and CBCT-ITVs to that of expected values. Conclusion: 4D-CT MIP-ITV and Union-ITV showed very good agreement that validates that ITV can be fast contoured on MIP.Contouring ITV in AIP must be avoided as it significantly underestimates the volume with all excursions. Free breathing CBCT-ITV showed good agreement with AIP-ITV but underestimated the MIP-ITV. Estimation of excursions and centroid values for 4D-CT and CBCT were in good agreement with expected values.

60 APPLIED LIFE SCIENCES↗

SU-E-J-244: Validation of a 6D-Robotic-Couch and Image Guidance Radiation Therapy (IGRT) System for Localization in World's First Single-Room Proton Therapy System

Purpose: The Mevion S250 proton therapy unit is equipped with a 6D-robotic couch and IGRT system (Verity). The patient alignment process allows corrections in six degrees of freedom: translation (x,y,z), pitch, roll, and yaw (θ,ϑ,ψ). Geometric accuracy of couch corrections and imaging vs. radiation isocenter coincidence were quantified before clinical implementation. Methods: A commercial phantom with sixteen 2mm tungsten BBs was rigidly couch-mounted and imaged with CT. Seventeen rigid translations/rotations of known magnitude were digitally applied to the original CT image using commercial software, validated with Varian OBI system. For each altered image, phantom was mounted on robotic couch in original position, then Verity 2D:2D match (PA-LLAT) was performed using DRRs from altered images. Corrections were recorded and applied, phantom was imaged a second time and residual corrections recorded. Physical measurements verified that applied couch corrections coincided with both physical couch shifts/rotations and known CT image translations/rotations. Additionally, image vs. radiation isocenter coicidence was quantified over couch treatment angles (±90° from setup position) using radiochromic film and an image-guided couch star-shot. Posterior-anterior and left-lateral kV radiographs were taken before each beam was delivered to verify imaging/radiation isocentricity. Results: Verity suggested couch corrections and known CT shifts/rotations agreed within ±1mm (average: Δ lat=0.5mm; Δ vert=0.4mm; Δ long=0.3mm) and ± 0.4° (average: Δ pitch=0.24° Δ roll=0.01°; Δ yaw=0.10°). Physical couch measurements and Verity applied corrections agreed within ± 1mm (average: Δlat=0.5mm; Δvert=0.4mm; Δlong=0.2mm) and ±0.2° (average: Δpitch=0.03°; Δ roll=0.04°; Δ yaw=0.04°). The directionality of all translations and rotations were qualitatively verified. The image vs. radiation isocenter coincidence was <1mm and radiation-isocenter precision was <1mm over the 180° of couch motion, as indicated by film analysis. Conclusion: The Verity IGRT software and 6D-couch combination on the Mevion S250 was verified as accurate within 1mm and 0.5°. This complies with the TG-142 standards for a stereotactic radiotherapy IGRT system. Rob Cessac is employed as Product Manager for Mevion Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-252: A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction

Purpose: A motion algorithm was developed to extract actual length, CT-numbers and motion amplitude of a mobile target imaged with cone-beam-CT (CBCT) retrospective to image-reconstruction. Methods: The motion model considered a mobile target moving with a sinusoidal motion and employed three measurable parameters: apparent length, CT number level and gradient of a mobile target obtained from CBCT images to extract information about the actual length and CT number value of the stationary target and motion amplitude. The algorithm was verified experimentally with a mobile phantom setup that has three targets with different sizes manufactured from homogenous tissue-equivalent gel material embedded into a thorax phantom. The phantom moved sinusoidal in one-direction using eight amplitudes (0–20mm) and a frequency of 15-cycles-per-minute. The model required imaging parameters such as slice thickness, imaging time. Results: This motion algorithm extracted three unknown parameters: length of the target, CT-number-level, motion amplitude for a mobile target retrospective to CBCT image reconstruction. The algorithm relates three unknown parameters to measurable apparent length, CT-number-level and gradient for well-defined mobile targets obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on actual length of the target and motion amplitude. The cumulative CT-number for a mobile target was dependent on CT-number-level of the stationary target and motion amplitude. The gradient of the CT-distribution of mobile target is dependent on the stationary CT-number-level, actual target length along the direction of motion, and motion amplitude. Motion frequency and phase did not affect the elongation and CT-number distributions of mobile targets when imaging time included several motion cycles. Conclusion: The motion algorithm developed in this study has potential applications in diagnostic CT imaging and radiotherapy to extract actual length, size and CT-numbers distorted by motion in CBCT imaging. The model provides further information about motion of the target.

60 APPLIED LIFE SCIENCES↗

SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation.

60 APPLIED LIFE SCIENCES↗

SU-E-J-271: A Feasibility Study to Utilize XR-QA2 Radiochromic Films as An Alternative Tool for Measuring Beam Parameters of Kilovoltage CBCT Systems

Purpose: The beam parameters of the x-ray beams used in image guidance are difficult to measure in water due to the low exposure. This study is to investigate if XR-QA2 radiochromic films can be used in obtaining beam parameters, such as beam profiles and outputs for kV-CBCT systems. Methods: The kV-CBCT beams were from a Varian OBI system. The films used were XR-QA2-GAFCHROMICTM films placed in the middle of two Plastic -Water slab phantoms at isocenter. The scanner used to analyze the films was an Epson Expression 1680 flat-bed scanner. Pre and 24 h-post-irradiated scans of films were obtained by using the reflective mode. The corresponding pixel-by-pixel dose in the films was obtained using a dose calibration equation as a function of net reflectance from the literature. Beam profiles of different scan protocols with and without bow-tie filters were measured. Monte Carlo simulations were used to compare the accuracy of the measured dose profiles. Results: The beam profiles measured from XR-QA2 films for different clinical default kV-CBCT scan protocols were benchmarked against Monte Carlo simulated profiles which have been validated by measurements performed in water phantom. We confirmed that a minimum post-irradiated time of 24 hours is necessary to pass to scan the films to account for light scatter stability. We found that the uncertainties of the results depend on the scan orientation of the film when analyzed in different directions. Conclusion: The XR-QA2 radiochromic films are sensitive to measure the x-ray beam profiles with irradiated dose ranging 1–5 cGy. The film measurements can be performed with an easy setup compared to ion chamber measurements in a water phantom. These films provide an alternative method to obtain the beam profiles for kV-CBCT beams.

60 APPLIED LIFE SCIENCES↗

SU-E-T-20: A Novel Hybrid CBCT, Bioluminescence and Fluorescence Tomography System for Preclinical Radiation Research

Purpose: A novel standalone bioluminescence and fluorescence tomography (BLT and FT) system equipped with high resolution CBCT has been built in our group. In this work, we present the system calibration method and validate our system in both phantom and in vivo environment. Methods: The CBCT is acquired by rotating the animal stage while keeping the x-ray source and detector panel static. The optical signal is reflected by the 3-mirror system to a multispectral filter set and then delivered to the CCD camera with f/1.4 lens mounted. Nine fibers passing through the stage and in contact with the mouse skin serve as the light sources for diffuse optical tomography (DOT) and FT. The anatomical information and optical properties acquired from the CBCT and DOT, respectively, are used as the priori information to improve the BLT/FT reconstruction accuracy. Flat field correction for the optical system was acquired at multiple wavelengths. A home-built phantom is used to register the optical and CBCT coordinates. An absolute calibration relating the CCD photon counts rate to the light fluence rate emitted at animal surface was developed to quantify the bioluminescence power or fluorophore concentration. Results: An optical inhomogeneous phantom with 2 light sources (3mm separation) imbedded is used to test the system. The optical signal is mapped onto the mesh generated from CBCT for optical reconstruction. Our preliminary results show that the center of mass can be reconstructed within 2.8mm accuracy. A live mouse with the light source imbedded is also used to validate our system. Liver or lung metastatic luminescence tumor model will be used for further testing. Conclusion: This hybrid system transforms preclinical research to a level that even sub-palpable volume of cells can be imaged rapidly and non-invasively, which largely extends the scope of radiobiological research. The research is supported by the NCI grant R01CA158100-01.

60 APPLIED LIFE SCIENCES↗

SU-E-T-68: Clinical Implementation of Total Skin Electron Beam Therapy: A New- York Presbyterian Hospital Experience

Purpose: Total skin electron beam therapy (TSET) is used in the treatment of rare skin diseases such as mycosis fungoides, the most common type of cutaneous T-cell lymphoma. We report our experience with clinical implementation of TSET. Methods: A modified six-dual-field irradiation technique was chosen to deliver TSET. A Varian Trilogy linear accelerator with a nominal 6 MeV beam using high dose rate total skin electron mode (HDTSe) was employed. The recommendations of AAPM task group report 23 were followed for the commissioning. An acrylic plate (energy degrader) of 3.2 mm depth was mounted on the HDTSe applicator. The nominal source to skin distance was set at 450 cm. The optimum tilt angle of the gantry was determined using NACP-02 ionization chamber embedded in certified therapy grade solid water. Percent depth dose measurements were performed using ionization chamber and radiochromic films embedded in solid water and anthropomorphic phantom. For absolute dose measurements, TG-51 formalism was employed. The dose distribution on the entire skin was measured by irradiating the anthropomorphic phantom, with TLDs attached, mimicking the real treatment. Results: The 3.2 mm acrylic plate mounted on the HDTSe applicator degraded the energy of the electron beam to 4.1 MeV in the treatment plane, located at an SSD of 450 cm. The optimum tilt angle was found to be ±20°. A single-dual field had a longitudinal uniformity, measured at a depth of dose maximum, of ±7% over a length of about 200 cm. For the entire treatment the multiplication factor was found to be 2.86. On the surface of the phantom, the dose varied from 108% to 93% of the prescription dose. Conclusion: We have successfully commissioned TSET meeting the guidelines of the TG report 23, and treated our first patient on February 25, 2014.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-69: Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)

Purpose: Patient-specific QA for VMAT is incapable of providing full 3D dosimetric information and is labor intensive in the case of severe heterogeneities or small-aperture beams. A cloud-based Monte Carlo dose reconstruction method described here can perform the evaluation in entire 3D space and rapidly reveal the source of discrepancies between measured and planned dose. Methods: This QA technique consists of two integral parts: measurement using a phantom containing array of dosimeters, and a cloud-based voxel Monte Carlo algorithm (cVMC). After a VMAT plan was approved by a physician, a dose verification plan was created and delivered to the phantom using our Varian Trilogy or TrueBeam system. Actual delivery parameters (i.e., dose fraction, gantry angle, and MLC at control points) were extracted from Dynalog or trajectory files. Based on the delivery parameters, the 3D dose distribution in the phantom containing detector were recomputed using Eclipse dose calculation algorithms (AAA and AXB) and cVMC. Comparison and Gamma analysis is then conducted to evaluate the agreement between measured, recomputed, and planned dose distributions. To test the robustness of this method, we examined several representative VMAT treatments. Results: (1) The accuracy of cVMC dose calculation was validated via comparative studies. For cases that succeeded the patient specific QAs using commercial dosimetry systems such as Delta- 4, MAPCheck, and PTW Seven29 array, agreement between cVMC-recomputed, Eclipse-planned and measured doses was obtained with >90% of the points satisfying the 3%-and-3mm gamma index criteria. (2) The cVMC method incorporating Dynalog files was effective to reveal the root causes of the dosimetric discrepancies between Eclipse-planned and measured doses and provide a basis for solutions. Conclusion: The proposed method offers a highly robust and streamlined patient specific QA tool and provides a feasible solution for the rapidly increasing use of VMAT treatments in the clinic.

60 APPLIED LIFE SCIENCES↗

SU-E-T-110: Development of An Independent, Monte Carlo, Dose Calculation, Quality Assurance Tool for Clinical Trials

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Purpose: To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. Methods: A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray beams was developed. Energy spectra of two photon sources corresponding to primary photons created in the target and scattered photons originating in the linear accelerator head were determined by an optimization process that fit the relative fluence of 0.25 MeV energy bins to the product of Fatigue-Life and Fermi functions to match calculated percent depth dose (PDD) data with that measured in a water tank for a 10x10cm2 field. Off-axis effects were modeled by a 3rd degree polynomial used to describe the off-axis half-value layer as a function of off-axis angle and fitting the off-axis fluence to a piecewise linear function to match calculated dose profiles with measured dose profiles for a 40×40cm2 field. The model was validated by comparing calculated PDDs and dose profiles for field sizes ranging from 3×3cm2 to 30×30cm2 to those obtained from measurements. A benchmarking study compared calculated data to measurements for IMRT plans delivered to anthropomorphic phantoms. Results: Along the central axis of the beam 99.6% and 99.7% of all data passed the 2%/2mm gamma criterion for 6 and 10MV models, respectively. Dose profiles at depths of dmax, through 25cm agreed with measured data for 99.4% and 99.6% of data tested for 6 and 10MV models, respectively. A comparison of calculated dose to film measurement in a head and neck phantom showed an average of 85.3% and 90.5% of pixels passing a 3%/2mm gamma criterion for 6 and 10MV models respectively. Conclusion: A Monte Carlo multiple-source model for Elekta 6 and 10MV therapeutic x-ray beams has been developed as a quality assurance tool for clinical trials.

60 APPLIED LIFE SCIENCES↗

SU-E-T-111: Development of Proton Dosimetry System Using Fiber-Optic Cerenkov Radiation Sensor Array

Purpose: We had developed and evaluated a new dosimetric system for proton therapy using array of fiber-optic Cerenkov radiation sensor (FOCRS) which can measure a percent depth dose (PDD) instantly. In this study, the Bragg peaks and spread out Bragg peak (SOBP) of the proton beams measured by FOCRS array were compared with those measured by an ion chamber. Methods and Method: We fabricated an optical fiber array of FOCRS in a handmade phantom which is composed of poly-methyl methacrylate (PMMA). There are 75 holes of 1mm diameter inside the phantom which is designed to be exposed in direction of beam when it is emerged in water phantom. The proton beam irradiation was carried out using IBA cyclotron PROTEUS 235 at national cancer center in Korea and a commercial data acquisition system was used to digitize the analog signal. Results: The measured Bragg peak and SOBP for the proton ranges of 7∼ 20 cm were well matched with the result from ion chamber. The comparison results show that the depth of proton beam ranges and the width of SOBP measured by array of FOCRS are comparable with the measurement from multi-layer ion chamber (MLIC) although there are some uncertainty in the measurement of FOCRS array for some specific beam ranges. Conclusion: The newly developed FOCRS array based dosimetric system for proton therapy can efficiently reduce the time and effort needed for proton beam range measurement compared to the conventional method and has the potential to be used for the proton pencil beam application.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-133: Dosimetric Impact of Scan Orientation Relative to Target Motion During Spot Scanning Proton Therapy

Purpose: This study seeks to evaluate the dosimetric effects of intra-fraction motion during spot scanning proton beam therapy as a function of beam-scan orientation and target motion amplitude. Method: Multiple 4DCT scans were collected of a dynamic anthropomorphic phantom mimicking respiration amplitudes of 0 (static), 0.5, 1.0, and 1.5 cm. A spot-scanning treatment plan was developed on the maximum intensity projection image set, using an inverse-planning approach. Dynamic phantom motion was continuous throughout treatment plan delivery.The target nodule was designed to accommodate film and thermoluminescent dosimeters (TLD). Film and TLDs were uniquely labeled by location within the target. The phantom was localized on the treatment table using the clinically available orthogonal kV on-board imaging device. Film inserts provided data for dose uniformity; TLDs provided a 3% precision estimate of absolute dose. An inhouse script was developed to modify the delivery order of the beam spots, to orient the scanning direction parallel or perpendicular to target motion.TLD detector characterization and analysis was performed by the Imaging and Radiation Oncology Core group (IROC)-Houston. Film inserts, exhibiting a spatial resolution of 1mm, were analyzed to determine dose homogeneity within the radiation target. Results: Parallel scanning and target motions exhibited reduced target dose heterogeneity, relative to perpendicular scanning orientation. The average percent deviation in absolute dose for the motion deliveries relative to the static delivery was 4.9±1.1% for parallel scanning, and 11.7±3.5% (p<<0.05) for perpendicularly oriented scanning. Individual delivery dose deviations were not necessarily correlated to amplitude of motion for either scan orientation. Conclusions: Results demonstrate a quantifiable difference in dose heterogeneity as a function of scan orientation, more so than target amplitude. Comparison to the analyzed planar dose of a single field hint that multiple-field delivery alters intra-fraction beam-target motion synchronization and may mitigate heterogeneity, though further study is warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-137: Dosimetric Validation for Pinnacle, Acuros, AAA, and Brainlab Algorithms with Induced Inhomogenieties

Purpose: To compare the dosimetric accuracy of the Eclipse 11.0 Acuros XB and Anisotropic Analytical Algorithm (AAA), Pinnacle-3 9.2 Collapsed Cone Convolution, and the iPlan 4.1 Monte Carlo (MC) and Pencil Beam (PB) algorithms using measurement as the gold standard. Methods: Ion chamber and diode measurements were taken for 6, 10, and 18 MV beams in a phantom made up of slab densities corresponding to solid water, lung, and bone. The phantom was setup at source-to-surface distance of 100 cm, and the field sizes were 3.0 × 3.0, 5.0 × 5.0, and 10.0 × 10.0 cm2. Data from the planning systems were computed along the central axis of the beam. The measurements were taken using a pinpoint chamber and edge diode for interface regions. Results: The best agreement between data from the algorithms and our measurements occurs away from the slab interfaces. For the 6 MV beam, iPlan 4.1 MC software performs the best with 1.7% absolute average percent difference from measurement. For the 10 MV beam, iPlan 4.1 PB performs the best with 2.7% absolute average percent difference from measurement. For the 18 MV beam, Acuros performs the best with 2.0% absolute average percent difference from measurement. It is interesting to note that the steepest drop in dose occurred the at lung heterogeneity-solid water interface of the18 MV, 3.0 × 3.0 cm2 field size setup. In this situation, Acuros and AAA performed best with an average percent difference within −1.1% of measurement, followed by iPlan 4.1 MC, which was within 4.9%. Conclusion: This study shows that all of the algorithms perform reasonably well in computing dose in a heterogeneous slab phantom. Moreover, Acuros and AAA perform particularly well at the lung-solid water interfaces for higher energy beams and small field sizes.

60 APPLIED LIFE SCIENCES↗

SU-E-T-164: Evaluation of Electron Dose Distribution Using Two Algorithms

Purpose: To appreciate the difference of electron dose distributions calculated from the Monte Carlo and Electron 3D algorithms of radiotherapy in a heterogeneous phantom. Methods: A phantom consisted of two different materials (lungs mimicked by low-density cork and others by polystyrene) with an 11x16 cm field size (SSD = 100 cm) was utilized to estimate the two-dimensional dose distributions under 6 and 18 MeV beams. On behalf of two different types of tissue, the heterogeneous phantom was comprised of 3 identical slabs in the longitudinal direction with a thickness of 1 cm for each slab and 2 with a thickness of 2.5 cm. The Monte Carlo/MCTP application package constituted of five codes was performed to simulate the electron beams of a Varian Clinac 23IX. A 20x20 cm2 type III (open walled) applicator was used in these simulations. It has been shown elsewhere that the agreement of the phase space data between the calculation results of MCTP application package and the measured data were within 2% on depth-dose and transverse profiles, as well as output factor calculations. The electron 3D algorithm owned by Pinnacle 8.0m and the MCTP application package were applied for the two-dimensional dose distributions calculation. The curves at 50% and 100%-prescribed dose were observed for 6 and 18 MeV beams, respectively. Results: The MC calculations results were compared with the electron 3D calculations in terms of two-dimensional dose distributions for 6 and 18 MeV beams showed excellent agreement except in distal boundary where it was the very junction of the high and low-density region. Conclusions: The Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues. Conclusion: A case study showed that the Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues.

60 APPLIED LIFE SCIENCES↗

SU-E-T-184: Feasibility of Superabsorbent Polymers as a Buildup Material

Purpose: To investigate the feasibility of superabsorbent polymers as a buildup material for radiation therapy Methods: A standard bolus, a layered damp towel, and a superabsorbent polymer (SAP) phantom were created and scanned to compare the Hounsfield units of each buildup material. A single field plan was developed on Eclipse TPS with AAA dose calculation algorithm to examine dose buildup. Relative film dosimetery (EBT3) was performed to evaluate the surface dose with each buildup material. Each buildup material had an approximate thickness of 0.5 cm and 100 monitor units with 6MV were delivered with solid water placed underneath film to simulate backscatter and more realistic surface dose. Results: The average HU units of the bolus, wet towel, and SAP phantom were 75 (SD=3), -378 (SD=113), -198 (SD=45) respectively. AAA dose calculation demonstrated sufficient dose buildup in all three materials. The relative surfaces doses to film were 23.7% without buildup, 87.5% with 0.5 cm bolus, 92.4% for the SAP phantom, and 87.1% for the damp towel. Conclusion: We demonstrate that superabsorbent polymers can provide sufficient dose buildup. Furthermore, due to the form in which SAPs are traditionally manufactured, this material is less expensive conforms more easily to irregular surfaces than standard sheets of bolus. Also, as a substance which is designed to absorb and retain water efficiently, SAPs are much more comfortable and more consistent than damp towels.

60 APPLIED LIFE SCIENCES↗