Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

BEYONDPLANCK XI. Bayesian CMB analysis with sample-based end-to-end error propagation

We present posterior sample-based cosmic microwave background (CMB) constraints from Planck LFI and WMAP observations as derived through global end-to-end Bayesian processing within the BeyondPlanck framework. We first use these samples to study correlations between CMB, foreground, and instrumental parameters, and we identify a particularly strong degeneracy between CMB temperature fluctuations and free-free emission on intermediate angular scales (400 ≲ ℓ ≲ 600), which is mitigated through model reduction, masking, and resampling. We compare our posterior-based CMB results with previous Planck products, and find generally good agreement, although with notably higher noise due to our exclusion of HFI data. We find a best-fit CMB dipole amplitude of 3362.7 ± 1.4 µK, in excellent agreement with previous Planck results. The quoted dipole uncertainty is derived directly from the sampled posterior distribution, and does not involve any ad hoc contributions for Planck instrumental systematic effects. Similarly, we find a temperature quadrupole amplitude of ${σ}_{2}^{TT}$ = 229 ± 97 µK 2 , which is in good agreement with previous results in terms of the amplitude, but the uncertainty is an order of magnitude larger than the naive diagonal Fisher uncertainty. Relatedly, we find lower evidence for a possible alignment between the quadrupole and octopole than previously reported due to a much larger scatter in the individual quadrupole coefficients, caused both by marginalizing over a more complete set of systematic effects, but also by our more conservative analysis mask required to mitigate the free-free degeneracy. For higher multipoles, we find that the angular temperature power spectrum is generally in good agreement with both Planck and WMAP. At the same time, we note that this is the first time the sample-based asymptotically exact Blackwell-Rao estimator has been successfully established for multipoles up to ℓ ≤ 600, and it now accounts for the majority of the cosmologically important information. Overall, this analysis demonstrates the unique capabilities of the Bayesian approach with respect to end-to-end systematic uncertainty propagation, and we believe it can and should play an important role in the analysis of future CMB experiments. Cosmological parameter constraints are presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYONDPLANCK X. Planck Low Frequency Instrument frequency maps with sample-based error propagation

We present Planck Low Frequency Instrument (LFI) frequency sky maps derived within the BEYONDPLANCK framework. This framework draws samples from a global posterior distribution that includes instrumental, astrophysical, and cosmological parameters, and the main product is an entire ensemble of frequency sky map samples, each of which corresponds to one possible realization of the various modeled instrumental systematic corrections, including correlated noise, time-variable gain, as well as far sidelobe and bandpass corrections. This ensemble allows for computationally convenient end-to-end propagation of low-level instrumental uncertainties into higher-level science products, including astrophysical component maps, angular power spectra, and cosmological parameters. We show that the two dominant sources of LFI instrumental systematic uncertainties are correlated noise and gain fluctuations, and the products presented here support – for the first time – full Bayesian error propagation for these effects at full angular resolution. We compared our posterior mean maps with traditional frequency maps delivered by the Planck Collaboration, and find generally good agreement. The most important quality improvement is due to significantly lower calibration uncertainties in the new processing, as we find a fractional absolute calibration uncertainty at 70 GHz of Δg 0 /g 0 = 5 x 10 -5 , which is nominally 40 times smaller than that reported by Planck 2018. However, we also note that the original Planck 2018 estimate has a nontrivial statistical interpretation, and this further illustrates the advantage of the new framework in terms of producing self-consistent and well-defined error estimates of all involved quantities without the need of ad hoc uncertainty contributions. We describe how low-resolution data products, including dense pixel-pixel covariance matrices, may be produced from the posterior samples directly, without the need for computationally expensive analytic calculations or simulations. We conclude that posterior-based frequency map sampling provides unique capabilities in terms of low-level systematics modeling and error propagation, and may play an important role for future Cosmic Microwave Background (CMB) B-mode experiments aiming at nanokelvin precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Hard x-rays nanoscale fluorescence imaging of Earth and Planetary science samples

A hard x-ray nanoprobe has been implemented at the synchrotron in Grenoble, France, allowing nondestructive trace element imaging of thick samples. Its advantages are nanometer spatial resolution on samples of several tens of micrometer, very high flux, and achromaticity. Nanometer imaging of a cometary grain from the NASA Stardust mission shows the sensitivity and resolution gains obtained while radically changing our understanding of the composition of heterogeneous samples. The probe opens unique possibilities in the study of minute, fragile samples fundamental to the earth and planetary sciences, which until now were out of the reach of direct analytical methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamically Polarized Sample for Neutron Scattering At the Spallation Neutron Source

The recently constructed Spallation Neutron Source at the Oak Ridge National Laboratory is quickly becoming the world's leader in neutron scattering sciences. In addition to the world's most intense pulsed neutron source, we are continuously constructing state of the art neutron scattering instruments as well as sample environments to address today and tomorrow's challenges in materials research. The Dynamically Polarized Sample project at the SNS is aimed at taking maximum advantage of polarized neutron scattering from polarized samples, especially biological samples that are abundant in hydrogen. Polarized neutron scattering will allow us drastically increase the signal to noise ratio in experiments such as neutron protein crystallography. The DPS project is near completion and all key components have been tested. Here we report the current status of the project.

36 MATERIALS SCIENCE↗

Optimization and calibration of atomic force microscopy sensitivity in terms of tip-sample interactions in high-order dynamic atomic force microscopy

The mechanism of dynamic force modes has been successfully applied to many atomic force microscopy (AFM) applications, such as tapping mode and phase imaging. The high-order flexural vibration modes are recent advancement of AFM dynamic force modes. AFM optical lever detection sensitivity plays a major role in dynamic force modes because it determines the accuracy in mapping surface morphology, distinguishing various tip-surface interactions, and measuring the strength of the tip-surface interactions. In this work, we have analyzed optimization and calibration of the optical lever detection sensitivity for an AFM cantilever-tip ensemble vibrating in high-order flexural modes and simultaneously experiencing a wide range and variety of tip-sample interactions. It is found that the optimal detection sensitivity depends on the vibration mode, the ratio of the force constant of tip-sample interactions to the cantilever stiffness, as well as the incident laser spot size and its location on the cantilever. It is also found that the optimal detection sensitivity is less dependent on the strength of tip-sample interactions for high-order flexural modes relative to the fundamental mode, i.e., tapping mode. When the force constant of tip-sample interactions significantly exceeds the cantilever stiffness, the optimal detection sensitivity occurs only when the laser spot locates at a certain distance from the cantilever-tip end. Thus, in addition to the 'globally optimized detection sensitivity', the 'tip optimized detection sensitivity' is also determined. Finally, we have proposed a calibration method to determine the actual AFM detection sensitivity in high-order flexural vibration modes against the static end-load sensitivity that is obtained traditionally by measuring a force-distance curve on a hard substrate in the contact mode.

36 MATERIALS SCIENCE↗

Atomic Layer Deposited Al{sub 2}O{sub 3} as Characterized Reference Samples for Nanolayer Metrology

Plasma assisted Atomic Layer Deposition Al{sub 2}O{sub 3} samples were studied using an approach of complementary metrology using Ellipsometry, X-Ray Reflectivity, Atomic Force Microscopy, and Total Reflection X-Ray Fluorescence. For modeling the samples, an interfacial rough SiO{sub 2} layer has to be assumed. The excellent linearity of the ALD process was used to cross check Ellipsometry and X-Ray Reflectivity. In contrast to Ellipsometry, X-Ray Reflectivity showed a residual surface layer, identified as chlorine contaminated layer by TXRF. The samples are shown to be ideal candidates for calibration of X-ray fluorescence as the Al signal linearly depends on the film thickness or ALD cycles. Furthermore, the impact of self-absorption of thick layers for TXRF was shown by the samples.

36 MATERIALS SCIENCE↗

Collection of solid and gaseous samples to diagnose inertial confinement fusion implosions

Collection of representative samples of debris following inertial confinement fusion implosions in order to diagnose implosion conditions and efficacy is a challenging endeavor because of the unique conditions within the target chamber such as unconverted laser light, intense pulse of x-rays, physical chunks of debris, and other ablative effects. We present collection of gas samples following an implosion for the first time. High collection fractions for noble gases were achieved. We also present collection of solid debris samples on flat plate collectors. Geometrical collection efficiencies for Au hohlraum material were achieved and collection of capsule debris (Be and Cu) was also observed. Asymmetric debris distributions were observed for Au and Be samples. Collection of Be capsule debris was higher for solid collectors viewing the capsule through the laser entrance hole in the hohlraum than for solid collectors viewing the capsule around the waist of the hohlraum. Collection of Au hohlraum material showed the opposite pattern: more Au debris was collected around the waist than through the laser entrance hole. The solid debris collectors were not optimized for minimal Cu backgrounds, which limited the conclusions about the symmetry of the Cu debris. The quality of the data limited conclusions on chemical fractionation effects within the burning, expanding, and then cooling plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The source-sample stage of the new two-dimensional angular correlation of annihilation radiation spectrometer at Technische Universitaet Muenchen

Angular correlation of annihilation radiation (ACAR) is a well established technique for the investigation of the electronic structure. A major limitation of ACAR studies is the available positron flux at a small spot on the sample. For this reason, the focus of this work is put on the discussion of a newly developed source-sample stage of the new 2D-ACAR spectrometer at Technische Universitaet Muenchen which uses an optimized static magnetic field configuration to guide the positrons onto the sample. The achieved spot diameter is d{sub FWHM}= 5.4 mm, with a high efficiency over the whole energy spectrum of the {sup 22}Na positron source. The implications of the performance of the source-sample stage are discussed with regard to 2D-ACAR measurements of single crystalline {alpha}-quartz, which serves as a model system for the determination of the total resolution. A value of (1.53 Multiplication-Sign 1.64) mrad{sup 2} FWHM was achieved at room temperature.

43 PARTICLE ACCELERATORS↗

Trace element content and magnetic properties of commercial HOPG samples studied by ion beam microscopy and SQUID magnetometry

In this study, the impurity concentration and magnetic response of nine highly oriented pyrolytic graphite (HOPG) samples with different grades and from different providers were determined using ion beam microscopy and SQUID magnetometry. Apart from sideface contaminations in the as-received state, bulk contamination of the samples in most cases consists of disk-shaped micron-sized particles made of Ti and V with an additional Fe contamination around the grain perimeter. The saturation magnetization typically increases with Fe concentration, however, there is no simple correlation between Fe content and magnetic moment. The saturation magnetization of one, respectively six, out of nine samples clearly exceeds the maximum contribution from pure Fe or Fe{sub 3}C. For most samples the temperature dependence of the remanence decreases linearly with T – a dependence found previously for defect-induced magnetism (DIM) in HOPG. We conclude that apart from magnetic impurities, additional contribution to the ferromagnetic magnetization exists in pristine HOPG in agreement with previous studies. A comparative study between the results of ion beam microscopy and the commonly used EDX analysis shows clearly that EDX is not a reliable method for quantitative trace elemental analysis in graphite, clarifying weaknesses and discrepancies in the element concentrations given in the recent literature.

36 MATERIALS SCIENCE↗

An in situ sample environment reaction cell for spatially resolved x-ray absorption spectroscopy studies of powders and small structured reactors

An easy-to-use sample environment reaction cell for X-ray based in situ studies of powders and small structured samples, e.g., powder, pellet, and monolith catalysts, is described. The design of the cell allows for flexible use of appropriate X-ray transparent windows, shielding the sample from ambient conditions, such that incident X-ray energies as low as 3 keV can be used. Thus, in situ X-ray absorption spectroscopy (XAS) measurements in either transmission or fluorescence mode are facilitated. Total gas flows up to about 500 ml{sub n}/min can be fed while the sample temperature is accurately controlled (at least) in the range of 25–500 °C. The gas feed is composed by a versatile gas-mixing system and the effluent gas flow composition is monitored with mass spectrometry (MS). These systems are described briefly. Results from simultaneous XAS/MS measurements during oxidation of carbon monoxide over a 4% Pt/Al{sub 2}O{sub 3} powder catalyst are used to illustrate the system performance in terms of transmission XAS. Also, 2.2% Pd/Al{sub 2}O{sub 3} and 2% Ag − Al{sub 2}O{sub 3} powder catalysts have been used to demonstrate X-ray absorption near-edge structure (XANES) spectroscopy in fluorescence mode. Further, a 2% Pt/Al{sub 2}O{sub 3} monolith catalyst was used ex situ for transmission XANES. The reaction cell opens for facile studies of structure-function relationships for model as well as realistic catalysts both in the form of powders, small pellets, and coated or extruded monoliths at near realistic conditions. The applicability of the cell for X-ray diffraction measurements is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Communication: Multiple atomistic force fields in a single enhanced sampling simulation

The main concerns of biomolecular dynamics simulations are the convergence of the conformational sampling and the dependence of the results on the force fields. While the first issue can be addressed by employing enhanced sampling techniques such as simulated tempering or replica exchange molecular dynamics, repeating these simulations with different force fields is very time consuming. Here, we propose an automatic method that includes different force fields into a single advanced sampling simulation. Conformational sampling using three all-atom force fields is enhanced by simulated tempering and by formulating the weight parameters of the simulated tempering method in terms of the energy fluctuations, the system is able to perform random walk in both temperature and force field spaces. The method is first demonstrated on a 1D system and then validated by the folding of the 10-residue chignolin peptide in explicit water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of radon concentration in some water samples belonging to some adjoining areas of Pathankot, Punjab

The study of radon concentration was measured in some areas of Pathankot district, Punjab, India, from the health hazard point of view due to radon. The exposure to radon through drinking water is largely by inhalation and ingestion. RAD 7, an electronic solid state silicon detector (Durridgeco., USA) was used to measure the radon concentration in drinking water samples of the study area. The recorded values of radon concentration in these water samples are below the recommended limit by UNSCEAR and European commission. The recommended limit of radon concentration in water samples is 4 to 40 Bq/l given by UNSCEAR [1] and European commission has recommended the safe limit for radon concentration in water sample is 100 Bq/l [2].

54 ENVIRONMENTAL SCIENCES↗

Radon exhalation rates from some soil samples of Kharar, Punjab

Radon and its progeny are major contributors in the radiation dose received by general population of the world. Because radon is a noble gas, a large portion of it is free to migrate away from radium. The primary sources of radon in the houses are soils and rocks source emanations, emanation from building materials, and entry of radon into a structure from outdoor air. Keeping this in mind the study of radon exhalation rate from some soil samples of the Kharar, Punjab has been carried out using Can Technique. The equilibrium radon concentration in various soil samples of Kharar area of district Mohali varied from 12.7 Bqm{sup −3} to 82.9 Bqm{sup −3} with an average of 37.5 ± 27.0 Bqm{sup −3}. The radon mass exhalation rates from the soil samples varied from 0.45 to 2.9 mBq/kg/h with an average of 1.4 ± 0.9 mBq/kg/h and radon surface exhalation rates varied from 10.4 to 67.2 mBq/m{sup 2}/h with an average of 30.6 ± 21.8 mBq/m{sup 2}/h. The radon mass and surface exhalation rates of the soil samples of Kharar, Punjab were lower than that of the world wide average.

54 ENVIRONMENTAL SCIENCES↗

Using stepped anvils to make even insulation layers in laser-heated diamond-anvil cell samples

Here, we describe a method to make even insulation layers for high-pressure laser-heated diamond-anvil cell samples using stepped anvils. Moreover, the method works for both single-sided and double-sided laser heating using solid or fluid insulation. The stepped anvils are used as matched pairs or paired with a flat culet anvil to make gasket insulation layers and not actually used at high pressures; thus, their longevity is ensured. We also compare the radial temperature gradients and Soret diffusion of iron between self-insulating samples and samples produced with stepped anvils and find that less pronounced Soret diffusion occurs in samples with even insulation layers produced by stepped anvils.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding and eliminating artifact signals from diffusely scattered pump beam in measurements of rough samples by time-domain thermoreflectance (TDTR)

Time-domain thermoreflectance (TDTR) is a pump-probe technique frequently applied to measure the thermal transport properties of bulk materials, nanostructures, and interfaces. One of the limitations of TDTR is that it can only be employed to samples with a fairly smooth surface. For rough samples, artifact signals are collected when the pump beam in TDTR measurements is diffusely scattered by the rough surface into the photodetector, rendering the TDTR measurements invalid. In this paper, we systemically studied the factors affecting the artifact signals due to the pump beam leaked into the photodetector and thus established the origin of the artifact signals. We find that signals from the leaked pump beam are modulated by the probe beam due to the phase rotation induced in the photodetector by the illumination of the probe beam. As a result of the modulation, artifact signals due to the leaked pump beam are registered in TDTR measurements as the out-of-phase signals. We then developed a simple approach to eliminate the artifact signals due to the leaked pump beam. We verify our leak-pump correction approach by measuring the thermal conductivity of a rough InN sample, when the signals from the leaked pump beam are significant. We also discuss the advantages of our new method over the two-tint approach and its limitations. Our new approach enables measurements of the thermal conductivity of rough samples using TDTR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid sampling of stochastic displacements in Brownian dynamics simulations

Here, we present a new method for sampling stochastic displacements in Brownian Dynamics (BD) simulations of colloidal scale particles. The method relies on a new formulation for Ewald summation of the Rotne-Prager-Yamakawa (RPY) tensor, which guarantees that the real-space and wave-space contributions to the tensor are independently symmetric and positive-definite for all possible particle configurations. Brownian displacements are drawn from a superposition of two independent samples: a wave-space (far-field or long-ranged) contribution, computed using techniques from fluctuating hydrodynamics and non-uniform fast Fourier transforms; and a real-space (near-field or short-ranged) correction, computed using a Krylov subspace method. The combined computational complexity of drawing these two independent samples scales linearly with the number of particles. The proposed method circumvents the super-linear scaling exhibited by all known iterative sampling methods applied directly to the RPY tensor that results from the power law growth of the condition number of tensor with the number of particles. For geometrically dense microstructures (fractal dimension equal three), the performance is independent of volume fraction, while for tenuous microstructures (fractal dimension less than three), such as gels and polymer solutions, the performance improves with decreasing volume fraction. This is in stark contrast with other related linear-scaling methods such as the force coupling method and the fluctuating immersed boundary method, for which performance degrades with decreasing volume fraction. Calculations for hard sphere dispersions and colloidal gels are illustrated and used to explore the role of microstructure on performance of the algorithm. In practice, the logarithmic part of the predicted scaling is not observed and the algorithm scales linearly for up to 4×10 6 particles, obtaining speed ups of over an order of magnitude over existing iterative methods, and making the cost of computing Brownian displacements comparable to the cost of computing deterministic displacements in BD simulations. Finally, a high-performance implementation employing non-uniform fast Fourier transforms implemented on graphics processing units and integrated with the software package HOOMD-blue is used for benchmarking.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical rare event sampling for extreme mesoscale weather

Extreme mesoscale weather, including tropical cyclones, squall lines, and floods, can be enormously damaging and yet challenging to simulate; hence, there is a pressing need for more efficient simulation strategies. Here, we present a new rare event sampling algorithm called quantile diffusion Monte Carlo (quantile DMC). Quantile DMC is a simple-to-use algorithm that can sample extreme tail behavior for a wide class of processes. We demonstrate the advantages of quantile DMC compared to other sampling methods and discuss practical aspects of implementing quantile DMC. To test the feasibility of quantile DMC for extreme mesoscale weather, we sample extremely intense realizations of two historical tropical cyclones, 2010 Hurricane Earl and 2015 Hurricane Joaquin. Our results demonstrate quantile DMC’s potential to provide low-variance extreme weather statistics while highlighting the work that is necessary for quantile DMC to attain greater efficiency in future applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sample shape and boundary dependence of measured transverse thermal properties

In spite of increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of $D_{xy}$ or $κ_{xy}$. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring $D_{xy}$ based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.

36 MATERIALS SCIENCE↗