Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

CCD imaging sensor with flashed backside metal film

A backside illuminated CCD imaging sensor for reading out image charges from wells of the array of pixels is significantly improved for blue, UV, far UV and low energy x-ray wavelengths (1-5000.ANG.) by so overthinning the backside as to place the depletion edge at the surface and depositing a thin transparent metal film of about 10.ANG. on a native-quality oxide film of less than about 30.ANG. grown on the thinned backside. The metal is selected to have a higher work function than that of the semiconductor to so bend the energy bands (at the interface of the semiconductor material and the oxide film) as to eliminate wells that would otherwise trap minority carriers. A bias voltage may be applied to extend the frontside depletion edge to the interface of the semiconductor material with the oxide film in the event there is not sufficient thinning. This metal film (flash gate), which improves and stabilizes the quantum efficiency of a CCD imaging sensor, will also improve the QE of any p-n junction photodetector.

Janesick, James R.↗

Reduced-Scale Transition-Edge Sensor Detectors for Solar and X-Ray Astrophysics

We have developed large-format, close-packed X-ray microcalorimeter arrays fabricated on solid substrates, designed to achieve high energy resolution with count rates up to a few hundred counts per second per pixel for X-ray photon energies upto 8 keV. Our most recent arrays feature 31-micron absorbers on a 35-micron pitch, reducing the size of pixels by about a factor of two. This change will enable an instrument with significantly higher angular resolution. In order to wire out large format arrays with an increased density of smaller pixels, we have reduced the lateral size of both the microstrip wiring and the Mo/Au transition-edge sensors (TES). We report on the key physical properties of these small TESs and the fine Nb leads attached, including the critical currents and weak-link properties associated with the longitudinal proximity effect.

Arrays↗

Closed-loop autonomous docking system

An autonomous docking system is provided which produces commands for the steering and propulsion system of a chase vehicle used in the docking of that chase vehicle with a target vehicle. The docking system comprises a passive optical target affixed to the target vehicle and comprising three reflective areas including a central area mounted on a short post, and tracking sensor and process controller apparatus carried by the chase vehicle. The latter apparatus comprises a laser diode array for illuminating the target so as to cause light to be reflected from the reflective areas of the target; a sensor for detecting the light reflected from the target and for producing an electrical output signal in accordance with an image of the reflected light; a signal processor for processing the electrical output signal in accordance with an image of the reflected light; a signal processor for processing the electrical output signal and for producing, based thereon, output signals relating to the relative range, roll, pitch, yaw, azimuth, and elevation of the chase and target vehicles; and a docking process controller, responsive to the output signals produced by the signal processor, for producing command signals for controlling the steering and propulsion system of the chase vehicle.

Dabney, Richard W.↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-J-91: Novel Epitaxial Silicon Array for Quality Assurance in Photon and Proton Therapy

Purpose: to demonstrate suitability of a novel silicon array for measuring the dose properties of highly conformal photon and proton beams. Methods: prototype under test is a 24cm long linear array prototype, although the underlying technology is suitable to construct 2D arrays as well. It is based on a 64pixels monolithic sensor with 1mm pixel pitch, made of epitaxial ptype silicon. Thanks to design modularity, more sensors can be placed side by side without breaking pixel pitch. Flattened and unflattened photon beams, as well as proton radiation from a cyclotron in pencil beam scanning mode, were considered. Measurements of beam characteristics as percentage depth doses, dose profiles, output factors and energy response, which are necessary to deliver radiation with high precision and reliability, were performed. Results: Dose rate independence with photons was verified in the dose per pulse range 0.03 to 2mGy. Results clearly indicate nondependence of the detector sensitivity both for flattened and unflattened beams, with a variation of at most 0.5percentage. OFs were obtained for field with a lateral size ranging from 0.8cm to 16cm and the results are in good agreement with ion chamber A1SL, max difference less than 1.5percentage. Field sizes and beam penumbra were measured and compared to EBT film results. Concerning proton beams, sensitivity independence on dose rate was verified by changing the beam current in the interval 2-130Gy/s. Field sizes and beam penumbra measurements are in agreement with data taken with a scintillating 2D array with 0.5mm resolution IBA Lynx, and a better penumbra definition than an array of ionization chambers IBA MatriXX is reached. Conclusion: The device is a novel and valuable tool for QA both for photon and proton dose delivery. All measurements demonstrated its capability to measure with high spatial resolution many crucial properties of the RT beam.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison and validation of acoustic response models for wind noise reduction pipe arrays

The detection capability of the infrasound component of the International Monitoring System (IMS) is tightly linked to the performance of its wind noise reduction systems. The wind noise reduction solution implemented at all IMS infrasound measurement systems consists of a spatial distribution of air inlets connected to the infrasound sensor through a network of pipes. This system, usually referred to as “pipe array,” has proven its efficiency in operational conditions. The objective of this paper is to present the results of the comparison and validation of three distinct acoustic response models for pipe arrays. The characteristics of the models and the results obtained for a defined set of pipe array configurations are described. A field experiment using a newly developed infrasound generator, dedicated to the validation of these models, is then presented. The comparison between the modeled and empirical acoustic responses shows that two of the three models can be confidently used to estimate pipe array acoustic responses. Lastly, this study paves the way to the deconvolution of IMS infrasound data from pipe array responses and to the optimization of pipe array design to IMS applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of InGaAs Linear Array for Applications to Remote Sensing

An Indium Gallium Arsenide linear photodiode array in the 1.1-2.5 micron spectral range was characterized. The array has 1024x1 pixels with a 25 micron pitch and was manufactured by Sensors Unlimited, Inc. Characterization and analysis of the electrical and optical properties of a camera system were carried out at room temperature to obtain detector performance parameters. The signal and noise were measured while the array was uniformly illuminated at varying exposure levels. A photon transfer curve was generated by plotting noise as a function of average signal to obtain the camera gain constant. The spectral responsivity was also measured, and the quantum efficiency, read noise and full-well capacity were determined. This paper describes the characterization procedure, analyzes the experimental results, and discusses the applications of the InGaAs linear array to future earth and planetary remote sensing mission.

Garcia, Christopher S.↗

On DESTINY Science Instrument Electrical and Electronics Subsystem Framework

Future space missions are going to require large focal planes with many sensing arrays and hundreds of millions of pixels all read out at high data rates'' . This will place unique demands on the electrical and electronics (EE) subsystem design and it will be critically important to have high technology readiness level (TRL) EE concepts ready to support such missions. One such omission is the Joint Dark Energy Mission (JDEM) charged with making precise measurements of the expansion rate of the universe to reveal vital clues about the nature of dark energy - a hypothetical form of energy that permeates all of space and tends to increase the rate of the expansion. One of three JDEM concept studies - the Dark Energy Space Telescope (DESTINY) was conducted in 2008 at the NASA's Goddard Space Flight Center (GSFC) in Greenbelt, Maryland. This paper presents the EE subsystem framework, which evolved from the DESTINY science instrument study. It describes the main challenges and implementation concepts related to the design of an EE subsystem featuring multiple focal planes populated with dozens of large arrays and millions of pixels. The focal planes are passively cooled to cryogenic temperatures (below 140 K). The sensor mosaic is controlled by a large number of Readout Integrated Circuits and Application Specific Integrated Circuits - the ROICs/ASICs in near proximity to their sensor focal planes. The ASICs, in turn, are serviced by a set of "warm" EE subsystem boxes performing Field Programmable Gate Array (FPGA) based digital signal processing (DSP) computations of complex algorithms, such as sampling-up-the-ramp algorithm (SUTR), over large volumes of fast data streams. The SUTR boxes are supported by the Instrument Control/Command and Data Handling box (ICDH Primary and Backup boxes) for lossless data compression, command and low volume telemetry handling, power conversion and for communications with the spacecraft. The paper outlines how the JDEM DESTINY concept instrument EE subsystem can be built now, a design; which is generally U.S. Government work not protected by U.S. copyright IEEEAC paper # 1429. Version 4. Updated October 19, 2009 applicable to a wide variety of missions using large focal planes with lar ge mosaics of sensors.

Kizhner, Semion↗

Improved Underwater Excitation-Emission Matrix Fluorometer

A compact, high-resolution, two-dimensional excitation-emission matrix fluorometer (EEMF) has been designed and built specifically for use in identifying and measuring the concentrations of organic compounds, including polluting hydrocarbons, in natural underwater settings. Heretofore, most EEMFs have been designed and built for installation in laboratories, where they are used to analyze the contents of samples collected in the field and brought to the laboratories. Because the present EEMF can be operated in the field, it is better suited to measurement of spatially and temporally varying concentrations of substances of interest. In excitation-emission matrix (EEM) fluorometry, fluorescence is excited by irradiating a sample at one or more wavelengths, and the fluorescent emission from the sample is measured at multiple wavelengths. When excitation is provided at only one wavelength, the technique is termed one-dimensional (1D) EEM fluorometry because the resulting matrix of fluorescence emission data (the EEM) contains only one row or column. When excitation is provided at multiple wavelengths, the technique is termed two-dimensional (2D) EEM fluorometry because the resulting EEM contains multiple rows and columns. EEM fluorometry - especially the 2D variety - is well established as a means of simultaneously detecting numerous dissolved and particulate compounds in water. Each compound or pool of compounds has a unique spectral fluorescence signature, and each EEM is rich in information content, in that it can contain multiple fluorescence signatures. By use of deconvolution and/or other mixture-analyses techniques, it is often possible to isolate the spectral signature of compounds of interest, even when their fluorescence spectra overlap. What distinguishes the present 2D EEMF over prior laboratory-type 2D EEMFs are several improvements in packaging (including a sealed housing) and other aspects of design that render it suitable for use in natural underwater settings. In addition, the design of the present 2D EEMF incorporates improvements over the one prior commercial underwater 2D EEMF, developed in 1994 by the same company that developed the present one. Notable advanced features of the present EEMF include the following: 1) High sensitivity and spectral resolution are achieved by use of an off-the-shelf grating spectrometer equipped with a sensor in the form of a commercial astronomical- grade 256 532-pixel charge-coupled-device (CCD) array. 2) All of the power supply, timing, control, and readout circuits for the illumination source and the CCD, ancillary environmental monitoring sensors, and circuitry for controlling a shutter or filter motor are custom-designed and mounted compactly on three circuit boards below a fourth circuit board that holds the CCD (see figure). 3) The compactness of the grating spectrometer, CCD, and circuit assembly makes it possible to fit the entire instrument into a compact package that is intended to be maneuverable underwater by one person. 4) In mass production, the cost of the complete instrument would be relatively low - estimated at approximately $30,000 at 2005 prices.

Moore, Casey↗

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm{sup 2}. We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced optical position sensors for magnetically suspended wind tunnel models

A major concern to aerodynamicists has been the corruption of wind tunnel test data by model support structures, such as stings or struts. A technique for magnetically suspending wind tunnel models was considered by Tournier and Laurenceau (1957) in order to overcome this problem. This technique is now implemented with the aid of a Large Magnetic Suspension and Balance System (LMSBS) and advanced position sensors for measuring model attitude and position within the test section. Two different optical position sensors are discussed, taking into account a device based on the use of linear CCD arrays, and a device utilizing area CID cameras. Current techniques in image processing have been employed to develop target tracking algorithms capable of subpixel resolution for the sensors. The algorithms are discussed in detail, and some preliminary test results are reported.

Lafleur, S.↗

A simple method for verifying the deployment of the TOMS-EP solar arrays

The Total Ozone Mapping Spectrometer-Earth Probe (TOMS-EP) mission relies upon a successful deployment of the spacecraft's solar arrays. Several methods of verification are being employed to ascertain the solar array deployment status, with each requiring differing amounts of data. This paper describes a robust attitude-independent verification method that utilizes telemetry from the coarse Sun sensors (CSS's) and the three-axis magnetometers (TAM's) to determine the solar array deployment status - and it can do so with only a few, not necessarily contiguous, points of data. The method developed assumes that the solar arrays are deployed. Telemetry data from the CSS and TAM are converted to the Sun and magnetic field vectors in spacecraft body coordinates, and the angle between them is calculated. Deployment is indicated if this angle is within a certain error tolerance of the angle between the reference Sun and magnetic field vectors. Although several other methods can indicate a non-deployed state, with this method there is a 70% confidence level in confirming deployment as well as a nearly 100% certainty in confirming a non-deployed state. In addition, the spacecraft attitude (which is not known during the first orbit after launch) is not needed for this algorithm because the angle between the Sun and magnetic field vectors is independent of the spacecraft attitude. This technique can be applied to any spacecraft with a TAM and with CSS's mounted on the solar array(s).

Koppersmith, James R.↗

TEMPERATURE MONITORING OPTIONS AVAILABLE AT THE IDAHO NATIONAL LABORATORY ADVANCED TEST REACTOR

As part of the Advanced Test Reactor National Scientific User Facility (ATR NSUF) program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced sensors for irradiation testing. To meet recent customer requests, an array of temperature monitoring options is now available to ATR users. The method selected is determined by test requirements and budget. Melt wires are the simplest and least expensive option for monitoring temperature. INL has recently verified the melting temperature of a collection of materials with melt temperatures ranging from 100 to 1000 C with a differential scanning calorimeter installed at INL’s High Temperature Test Laboratory (HTTL). INL encapsulates these melt wires in quartz or metal tubes. In the case of quartz tubes, multiple wires can be encapsulated in a single 1.6 mm diameter tube. The second option available to ATR users is a silicon carbide temperature monitor. The benefit of this option is that a single small monitor (typically 1 mm x 1 mm x 10 mm or 1 mm diameter x 10 mm length) can be used to detect peak irradiation temperatures ranging from 200 to 800 C. Equipment has been installed at INL’s HTTL to complete post-irradiation resistivity measurements on SiC monitors, a technique that has been found to yield the most accurate temperatures from these monitors. For instrumented tests, thermocouples may be used. In addition to Type-K and Type-N thermocouples, a High Temperature Irradiation Resistant ThermoCouple (HTIR-TC) was developed at the HTTL that contains commercially-available doped molybdenum paired with a niobium alloy thermoelements. Long duration high temperature tests, in furnaces and in the ATR and other MTRs, demonstrate that the HTIR-TC is accurate up to 1800 C and insensitive to thermal neutron interactions. Thus, degradation observed at temperatures above 1100 C with Type K and N thermocouples and decalibration due to transmutation with tungsten-rhenium and platinum rhodium thermocouples can be avoided. INL is also developing an Ultrasonic Thermometry (UT) capability. In addition to small size, UT’s offer several potential advantages over other temperature sensors. Measurements may be made near the melting point of the sensor material, potentially allowing monitoring of temperatures up to 3000 C. In addition, because no electrical insulation is required, shunting effects are avoided. Most attractive, however, is the ability to introduce acoustic discontinuities to the sensor, as this enables temperature measurements at several points along the sensor length. As discussed in this paper, the suite of temperature monitors offered by INL is not only available to ATR users, but also to users at other MTRs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless Technologies Implications for Power Systems

Wireless technologies have advanced well beyond simple SCADA radio systems and point-to-point links. The current applications supported by industrial-grade wireless sensors and systems range from field measurements (classic I/O) to voice, video, asset tracking, mobile operators, etc. Which such a wide array of supported applications, the belief that wireless technology will only impact power systems in terms of wireless sensors is shortsighted. This paper, coauthored by a group of individuals intimately involved in the general realm of industrial wireless , presents a simple snapshot of current radio technologies that are used (or seriously contemplated for use) in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flex-PCB Quench Antenna Developments at FNAL

We report flexible printed-circuit-board-based quench antenna arrays have been developed at FNAL since 2017. They proved to be low-noise, low-cost, sensitive, and non-invasive sensors for quench characterization in superconducting magnets, having the potential to extend even to quench detection. Starting with applications of small area sensors of this type, we have explored feasibility for operations at high pressure, and have invested in multi-channel quench antenna arrays covering the complete area of the innermost magnet layer of the conductor. We've also tested and optimized sensor geometry and relative orientations to increase sensitivity and spatial resolution. Beyond developments of warm and cold bore antennas, we've progressed to concepts which attach quench antennas to the conductor surfaces of accelerator magnets. Multiple programs and projects at FNAL and collaborating institutions benefited from this work already and our plans target further extensions of capabilities and applicability of these devices. In this paper we present the logic behind the development steps taken so far, status of our work and direction of near-term research on quench antennas at Fermilab.

43 PARTICLE ACCELERATORS↗

Gyro and accelerometer failure detection and identification in redundant sensor systems.

An algorithm for failure detection and identification for redundant non-orthogonal arrays of single degree of freedom gyros and accelerometers is described which is optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Handheld multi-sensor biometric imaging device and processing pipeline

A handheld biometric imaging device having an array of cameras configured to simultaneously capture face, iris and fingerprint biometrics of a subject. The device includes a plurality of visible-light cameras and a plurality of infrared-light cameras capable of being triggered simultaneously to obtain a plurality of images from which a 3D image of the light field can be constructed. The device includes a plurality of visible-light illuminators and a plurality of infrared-light illuminators that allow images of a subject to be captured under different lighting profiles. The device may include an onboard control system that is capable of reconstructing a face region, an iris region and a fingerprint region from the 3D light-field image, and then extract a corresponding face template, an iris template, and a fingerprint template from the respective reconstructed regions. The extracted face, iris, and fingerprint templates may be used for enrollment and/or comparison against a biometric-template database associated with one or more watchlists.

Bolme, David S.↗

Directionally Sensitive Silicon Radiation Sensor (VCELL)

Sensors are a mission critical element in many NASA programs and require some very unique properties such as small size, low power, high reliability, low weight. Low cost sensors offer the possibility of technology transfer to the public domain for commercial applications. One sensor application that is important to many NASA programs is the ability to point at a radiation source, such as the sun. Such sensors may be an integral part of the guidance and control systems in space platforms and in remote exploratory vehicles. Sun/solar pointing is also important for ground-based systems such as solar arrays. These systems are not required to be small and lightweight. However, if a sensor with a sun pointing capability was developed that is very small, rugged, lightweight and at the same time low cost, it certainly could be used in existing and perhaps many new ground based applications. The objective of the VCELL (Directionally Sensitive Silicon Radiation Sensor) research is to develop a new and very unique silicon based directionally sensitive radiation sensor which can be fabricated using conventional monolithic IC technologies and which will meet the above requirements. The proposed sensor is a novel silicon chip that is directionally sensitive to incident radiation, providing azimuth and elevation information on the incident radiation. The resulting sensor chip will be appropriate for integration into a silicon IC or useful in a hybrid structure to be interfaced with a standard IEEE 1451 bus interface IC to create an Intelligent Sensor. It is presently estimated that it will require about three man-years of effort to complete the VCELL research and development. This includes the optical, electrical, mechanical and silicon fabrication and testing as well as computer simulations and theoretical analysis and modeling including testing in simulated space environments. This report summarizes the sensor research completed this summer as part of the Summer Faculty Fellowship Program. The primary effort was focused on activity necessary to fabricate prototype sensor.

Koy B. Cook↗