Magnetic Materials Characterization and Modeling for the Enhanced Design of Magnetic Shielding of Cryomodules in Particle Accelerators

Particle accelerators produce beams of high-energy particles, which are used for both fundamental and applied scientific research and are critical to the development of accelerator driven sub-critical reactor systems. An effective magnetic shield is very important to achieve higher quality factor (Qo) of the cryomodule of a particle accelerator. The allowed value of field inside the cavity due to all external fields (particularly the Earth’s magnetic field) is ~15 mG or less. The goal of this PhD dissertation is to comprehensively study the magnetic properties of commonly used magnetic shielding materials at both cryogenic and room temperatures. This knowledge can be used for the enhanced design of magnetic shields of cryomodes (CM) in particle accelerators. To this end, we first studied the temperature dependent magnetization behavior (M-H curves) of Amumetal and A4K under different annealing and deformation conditions. This characterized the effect of stress or deformation induced during the manufacturing processes and subsequent restoration of high permeability with appropriate heat treatment. Next, an energy based stochastic model for temperature dependent anhysteretic magnetization behavior of ferromagnetic materials was proposed and benchmarked against experimental data. We show that this model is able to simulate and explain the magnetic behavior of as rolled, deformed and annealed amumetal and A4K over a large range of temperatures. The experimental results for permeability are then used in a finite element model (FEM) in COMSOL to evaluate the shielding effectiveness of multiple shield designs at room temperature as well as cryogenic temperature. This work could serve as a guideline for future design, development and fabrication of magnetic shields of CMs.

Sah, Sanjay↗

Materials path toward improved energy efficiency for High Energy Physics accelerators

For nearly fifty years researchers working with particle accelerators have envisioned reducing their initial and operating costs by substituting the intermetallic compound Nb 3 Sn for Nb as the cavity interior surface. The goal has remained elusive, stymied especially by the fall of cavity quality factor (representing increasing energy consumption) with increasing gradient (the amount of accelerator need to reach an energy goal). While one research group reported making a few cavities free of the problem, no one has reported how this comes about or has reproduced the improvement. We believe that insufficient understanding is responsible. We report here findings of a detailed, systematic study of the formation of Nb 3 Sn coatings on Nb, relating structure and properties of the coating to the process parameters and substrate materials on the one hand, and RF surface impedance and SRF cavity performance on the other was carried out, focusing on the two step (nucleation – deposition) tin vapor diffusion process. Major outcomes are: The choice of initial surface preparation (BCP etc) has no discernable impact on any quality of the final coating; Though tin chloride serves as the coating nucleant, no trace could be found by any means of chlorine after nucleation or coating; No evidence was found for any substantive impact of the details of the nucleation on the ultimate coating, as long as it was done within the frequently used range; The coating forms as Nb 3 Sn crystals by tin from the vapor diffusing down grain boundaries to the Nb interface and growing there. Higher temperature and longer time lead to larger, but otherwise substantially identical crystals; All coatings exhibited roughness on the micron scale. Testing the effect of coating surface modification technologies in use by the community, only a carefully tailored electropolish showed significant benefit; and, Preliminary results indicate that Ti contamination may be associated with falling gradient. Two particular item appear promising for future work. The effect of surface topography in the range seen here on performance is significant for niobium. The nature and impact on Nb 3 Sn, if any, needs to be understood and managed. At what level Ti, Ta or other impurities affects the performance of Nb 3 Sn needs to be understood.

36 MATERIALS SCIENCE↗

Surface Treatments of Nb by Buffered Electropolishing

Buffered electropolishing (BEP) is a Nb surface treatment technique developed at Jefferson Lab1. Experimental results obtained from flat Nb samples show2-4 that BEP can produce a surface finish much smoother than that produced by the conventional electropolishing (EP), while Nb removal rate can be as high as 4.67 μm/min. This new technique has been applied to the treatments of Nb SRF single cell cavity employing a vertical polishing system5 constructed at JLab as well as a horizontal polishing system at CEA Saclay. Preliminary results show that the accelerating gradient can reach 32 MV/m for a large grain cavity and 26.7 MV/m for a regular grain cavity. In this presentation, the latest progresses from the international collaboration between Peking University, CEA Saclay, and JLab on BEP will be summarized.

36 MATERIALS SCIENCE↗

Automatic Phase Calibration for RF Cavities using Beam-Loading Signals

Precise calibration of the cavity phase signals is necessary for the operation of any particle accelerator. For many systems this requires human in the loop adjustments based on measurements of the beam parameters downstream. Some recent work has developed a scheme for the calibration of the cavity phase using beam measurements and beam-loading however this scheme is still a multi-step process that requires heavy automation or human in the loop. In this paper we analyze a new scheme that uses only RF signals reacting to beam-loading to calculate the phase of the beam relative to the cavity. This technique could be used in slow control loops to provide real-time adjustment of the cavity phase calibration without human intervention thereby increasing the stability and reliability of the accelerator.

43 PARTICLE ACCELERATORS↗

Measuring orbit responses with oscillating trajectories in the Fermilab Linac

Recording changes in beam transverse positions and longitudinal phase reported by Beam Position Monitors (BPMs) in response to a beam deflection by an upstream dipole corrector or RF cavity phase (orbit response) is a powerful tool for analysis of accelerator optics and assisting with machine tuning. In Fermilab Linac, orbit responses were recorded by oscillating the corrector currents and cavity phases in a sinusoidal manner parasitically during regular operation, simultaneously oscillating up to 19 correctors and 7 cavities at distinct frequencies, providing faster, drift-resistant measurements through frequency-domain analysis. This report describes the technique, including error estimations and consistency checks and shows examples of the measurements.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

Electrostatic hydrogen-cyclotron wave emission below the hydrogen-cyclotron frequency in the auroral acceleration region

A mechanism is suggested for the excitation of electrostatic ion-cyclotron waves at frequencies below the ion-cyclotron frequency in the midst of the auroral acceleration region, which is assumed to consist of downward moving double layers. The mechanism involves upward flowing ions interacting with a downward flowing background plasma. The upward flowing ions are the ion beams accelerated by the double layer. The downward motion of the background plasma corresponds to a plasma expansion into the density cavity that develops in connection with double layer formation in the acceleration region. The ion-cyclotron waves excited by the counterstreaming flows are doppler shifted to frequencies below the harmonics of the ion cyclotron frequency. It is suggested that such wave emissions could account for some very narrow-banded waves at frequencies below the hydrogen cyclotron frequency that were observed by the S3-3 satellite.

Singh, N.↗

Nb3Sn films for SRF cavities: genesis and RF properties

Understanding of Nb3Sn nucleation and growth is essential to the progress with Nb3Sn vapor diffusion coatings of SRF cavities. Samples representing different stages of Nb3Sn formation have been produced and examined to elucidate the effects of nucleation, growth, process conditions, and impurities. Nb3Sn films from few hundreds of nm up to ~15 µm were grown and characterized using AFM, SEM/EDS, XPS, EBSD, SIMS, and SAM. Microscopic examinations of samples suggest the mechanisms behind Nb3Sn thin film nucleation and growth. RF measurements of coated cavities were combined with material characterization of witness samples to adapt the coating process in "Siemens" coating configuration. Understanding obtained from sample studies, applied to cavities, resulted in Nb3Sn cavity with quality factor 2 ×1010 at 15 MV/m accelerating gradient at 4 K, without "Wuppertal" Q-slope. We discuss the genesis of the Nb3Sn thin film in a typical tin vapor diffusion process, and its consequences to the coating of SRF cavities.

Pudasaini, U.↗

The Advanced Photon Source pulsed deflecting cavity RF system.

The Advanced Photon Source Deflecting Cavity System for producing short X-ray pulses uses two multi-cell, S-band cavities to apply a deflecting voltage to the stored electron beam ahead of an undulator that supports a beamline utilizing picosecond X-rays. Two additional multi-cell cavities are then used to cancel out the perturbation and restore the electron beam to its nominal orbit. The pulsed rf system driving the deflecting cavities is described. Design tradeoffs are discussed with emphasis on topology considerations and digital control loops making use of sampling technology in a manner consistent with the present state of the art.

43 PARTICLE ACCELERATORS↗

WAVEGUIDE COUPLER KICK TO BEAM BUNCH AND CURRENT DEPENDENCY ON SRF CAVITIES

JLAB SRF cavities employ waveguide type fundamental power couplers (FPC). The FPC design for the 7-cell upgrade cavities was optimized to minimize the dipole field kick. For continuous wave (CW) operation, the forwarding RF power will be at different magnitude to drive the different beam current and cavity gradient. This introduces some deviation from optimized FPC field for varying beam loading. This article analyzes the beam behavior both in centroid kick and head-tail kick under different beam loading conditions.

43 PARTICLE ACCELERATORS↗

Design and prototyping of HL-LHC double quarter wave crab cavities for SPS test

The LHC high luminosity project envisages the use of the crabbing technique for increasing and levelling the LHC luminosity. Double Quarter Wave (DQW) resonators are compact cavities especially designed to meet the technical and performance requirements for LHC beam crabbing. Two DQW crab cavities are under fabrication and will be tested with beam in the Super Proton Synchrotron (SPS) at CERN by 2017. This paper describes the design and prototyping of the DQW crab cavities for the SPS test.

43 PARTICLE ACCELERATORS↗

Impact of nitrogen and oxygen interstitials on niobium SRF cavity performance

Superconducting radio frequency (SRF) cavities are the leading technology for highly efficient particle acceleration, and their performance can be significantly enhanced through the controlled introduction of interstitial impurities into bulk niobium. Nitrogen doping has demonstrated a substantial reduction in surface resistance, which improves the quality factor of the cavities. More recently, oxygen doping has emerged as a promising alternative, demonstrating comparable reductions in surface resistance. In this study, we combine cavity measurements on 1.3 GHz niobium SRF cavities subjected to a range of nitrogen- and oxygen-based treatments with material characterizations performed on cavity cutouts processed under identical conditions. This approach allows us to quantitatively assess the contribution of each impurity to the reduction of surface resistance. We find that nitrogen is ten times more effective than oxygen in reducing surface resistance at 16 MV/m. We also observe an additive effect of O and N impurities in reducing RT. We discuss these results in the context of field-dependent nonequilibrium superconductivity, gap enhancement, and hydrogen trapping mechanisms.

Hu, H. [Chicago U.; Fermilab] (ORCID:0009000330621↗

A design study for photon diagnostics for the APS storage ring short-pulse x-ray source.

A short x-ray pulse source based on the crab cavity scheme proposed by Zholents is being developed at the Advanced Photon Source (APS). Photon diagnostics that visualize the electron bunches with transverse momentum chirp and verify the performance of the short x-ray pulse are required. We present a design study for the imaging diagnostics inside and outside of the crab cavity zone, utilizing both x-ray and visible synchrotron radiation. The diagnostics outside of the crab cavity zone will be used to map out stable operation parameters of the storage ring with crab cavities and to perform single-bunch, single- pass imaging of the chirped bunch, which facilitates optimizing the performance of the short-pulse source without disturbing other users around the ring.

43 PARTICLE ACCELERATORS↗

A Resonant Cavity Approach to Non-Invasive, Pulse-to-Pulse EmittanceMeasurement

We present a resonant cavity approach for non-invasive, pulse-to-pulse, beam emittance measurements of non-circular multi-bunch beams. In a resonant cavity, desired field components can be enhanced up to Q{sub L{lambda}}/{pi}, where Q{sub L{lambda}} is the loaded quality factor of the resonant mode {lambda}, when the cavity resonant mode matches the bunch frequency of a bunch-train beam pulse. In particular, a quad-cavity, with its quadrupole mode (TM{sub 220} for rectangular cavities) at beam operating frequency, rotated 45{sup o} with respect to the beamline, extracts the beam quadrupole moment exclusively, utilizing the symmetry of the cavity and some simple networks to suppress common modes. Six successive beam quadrupole moment measurements, performed at different betatron phases in a linear transport system determine the beam emittance, i.e. the beam size and shape in the beam's phase space, if the beam current and position at these points are known. In the presence of x-y beam coupling, ten measurements are required. One measurement alone provides the rms-beam size of a large aspect ratio beam. The resolution for such a measurement of rms-beam size with the rectangular quad-cavity monitor presented in this article is estimated to be on the order of ten microns. A prototype quad-cavity was fabricated and preliminary beam tests were performed at the Next Linear Collider Test Accelerator (NLCTA) at the Stanford Linear Accelerator Center (SLAC). Results were mainly limited by beam jitter and uncertainty in the beam position measurement at the cavity location. This motivated the development of a position-emittance integrated monitor.

43 PARTICLE ACCELERATORS↗

Fluid Physics in a Fluctuating Acceleration Environment

Our program of research aims at developing a stochastic description of the residual acceleration field onboard spacecraft (g-jitter) to describe in quantitative detail its effect on fluid motion. Our main premise is that such a statistical description is necessary in those cases in which the characteristic time scales of the process under investigation are long compared with the correlation time of g-jitter. Although a clear separation between time scales makes this approach feasible, there remain several difficulties of practical nature: (i), g-jitter time series are not statistically stationary but rather show definite dependences on factors such as active or rest crew periods; (ii), it is very difficult to extract reliably the low frequency range of the power spectrum of the acceleration field. This range controls the magnitude of diffusive processes; and (iii), models used to date are Gaussian, but there is evidence that large amplitude disturbances occur much more frequently than a Gaussian distribution would predict. The lack of stationarity does not constitute a severe limitation in practice, since the intensity of the stochastic components changes very slowly during space missions (perhaps over times of the order of hours). A separate analysis of large amplitude disturbances has not been undertaken yet, but it does not seem difficult a priori to devise models that may describe this range better than a Gaussian distribution. The effect of low frequency components, on the other hand, is more difficult to ascertain, partly due to the difficulty associated with measuring them, and partly because they may be indistinguishable from slowly changing averages. This latter effect is further complicated by the lack of statistical stationarity of the time series. Recent work has focused on the effect of stochastic modulation on the onset of oscillatory instabilities as an example of resonant interaction between the driving acceleration and normal modes of the system, and on cavity flow as an example of how an oscillatory response under periodic driving becomes diffusive if the forcing is random instead. This paper describes three different topics that illustrate behavior that is peculiar to a stochastic acceleration field. In the first case, we show that g-jitter can induce effective attractive or repulsive forces between a pair of spherical particles that are suspended in an incompressible fluid of different density provided that the momentum diffusion length is larger than the interparticle separation (as in the case in most colloidal suspensions). Second, a stochastic modulation of the control parameter in the vicinity of a pitchfork or supercritical bifurcation is known not to affect the location of the threshold. We show, however, that resonance between the modulation and linearly stable modes close to onset can lead to a shift in threshold. Finally, we discuss the classical problem of vorticity diffusion away from a plane boundary that is being vibrated along its own plane. Periodic motion with zero average vorticity production results in an exponential decay of the vorticity away from the boundary. Random vibration, on the other hand, results in power law decay away from the boundary even if vorticity production averages to zero.

Drolet, Francois↗

Statistical Modeling of Peak Accelerating Gradients in LCLS-II and LCLS-II-HE

In this report, we study the vertical test gradient performance and the gradient degradation between vertical test and cryomodule test for the 1.3 GHz LCLS-II cavities. We develop a model of peak gradient statistics, and use our understanding of the LCLS-II results and the changes implemented for LCLS-II-HE to estimate the expected gradient statistics for the new machine. Finally, we lay out a plan to ensure that the LCLS-II-HE cryomodule gradient specifications are met while minimizing cavity disqualification by introducing a variable acceptance threshold for the accelerating gradient.