Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Evaluating the effectiveness of impact assessment instruments: Theorising the nature and implications of their political constitution

The central role of impact assessment instruments globally in policy integration initiatives has been cemented in recent years. Associated with this trend, but also reflecting political emphasis on greater accountability in certain policy sectors and a renewed focus on economic competitiveness in Western countries, demand has increased for evidence that these instruments are effective (however defined). Resurgent interest in evaluation has not, however, been accompanied by the conceptual developments required to redress longstanding theoretical problems associated with such activities. In order to sharpen effectiveness evaluation theory for impact assessment instruments this article critically examines the neglected issue of their political constitution. Analytical examples are used to concretely explore the nature and significance of the politicisation of impact assessment. It is argued that raising awareness about the political character of impact assessment instruments, in itself, is a vital step in advancing effectiveness evaluation theory. Broader theoretical lessons on the framing of evaluation research are also drawn from the political analysis. We conclude that, at least within the contemporary research context, learning derived from analysing the meaning and implications of plural interpretations of effectiveness represents the most constructive strategy for advancing impact assessment and policy integration theory.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

In this study, a new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

42 ENGINEERING↗

Informed-Proteomics: open-source software package for top-down proteomics

Top-down proteomics involves the analysis of intact proteins. This approach is very attractive as it allows for analyzing proteins in their endogenous form without proteolysis, preserving valuable information about post-translation modifications, isoforms, proteolytic processing or their combinations collectively called proteoforms. Moreover, the quality of the top-down LC-MS/MS datasets is rapidly increasing due to advances in the liquid chromatography and mass spectrometry instrumentation and sample processing protocols. However, the top-down mass spectra are substantially more complex compare to the more conventional bottom-up data. To take full advantage of the increasing quality of the top-down LC-MS/MS datasets there is an urgent need to develop algorithms and software tools for confident proteoform identification and quantification. In this study we present a new open source software suite for top-down proteomics analysis consisting of an LC-MS feature finding algorithm, a database search algorithm, and an interactive results viewer. The presented tool along with several other popular tools were evaluated using human-in-mouse xenograft luminal and basal breast tumor samples that are known to have significant differences in protein abundance based on bottom-up analysis.

Environmental Molecular Sciences Laboratory↗

Spatial Proteomics towards cellular Resolution

Introduction: Spatial biology is an emerging interdisciplinary field facilitating biological discoveries through the use of spatial omics technologies. Recent advancements in spatial transcriptomics, spatial genomics (e.g. genetic mutations and epigenetic marks), multiplexed immunofluorescence, and spatial metabolomics/lipidomics have enabled high-resolution spatial profiling of gene expression, genetic variation, protein expression, and metabolites/lipids profiles in tissue. These developments contribute to a deeper understanding of the spatial organization within tissue microenvironments at the molecular level. Areas covered: This report provides an overview of the untargeted, bottom-up mass spectrometry (MS)-based spatial proteomics workflow. It highlights recent progress in tissue dissection, sample processing, bioinformatics, and liquid chromatography (LC)-MS technologies that are advancing spatial proteomics toward cellular resolution. Expert opinion: The field of untargeted MS-based spatial proteomics is rapidly evolving and holds great promise. To fully realize the potential of spatial proteomics, it is critical to advance data analysis and develop automated and intelligent tissue dissection at the cellular or subcellular level, along with high-throughput LC-MS analyses of thousands of samples. In conclusion, achieving these goals will necessitate significant advancements in tissue dissection technologies, LC-MS instrumentation, and computational tools.

59 BASIC BIOLOGICAL SCIENCES↗

Synchrotron-based X-ray diffraction of the lead apatite series Pb[subscript 10](PO[subscript 4])[subsript 6]Cl[subscript 2]-Pb[subscript 10](AsO[subscript 4])[subscript 6]Cl[subscript 2]

A number of compounds of the pyromorphite-mimetite solid solution series were synthesized at room temperature and analyzed with infrared spectroscopy and powder X-ray diffraction. High-resolution high-quality powder diffraction data were obtained by means of the state-of-the-art instrument at the 11-BM beamline of the Advanced Photon Source at Argonne National Laboratory, Argonne, IL, USA. The unit-cell dimensions, atomic position and atomic displacement parameters, as well as site occupancy for analyzed phases, were refined by the Rietveld method and reported herein for the first time. The results of this study indicate that the pyromorphite-mimetite series is continuous in near-Earth-surface environments. Detailed structural changes caused by P{sup 5+}-As{sup 5+} substitutions in minerals from the pyromorphite-mimetite solid solution series are reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ X-ray data collection and structure phasing of protein crystals at Structural Biology Center 19-ID

A prototype of a 96-well plate scanner for in situ data collection has been developed at the Structural Biology Center (SBC) beamline 19-ID, located at the Advanced Photon Source, USA. The applicability of this instrument for protein crystal diffraction screening and data collection at ambient temperature has been demonstrated. Several different protein crystals, including selenium-labeled, were used for data collection and successful SAD phasing. Without the common procedure of crystal handling and subsequent cryo-cooling for data collection at T = 100 K, crystals in a crystallization buffer show remarkably low mosaicity (<0.1°) until deterioration by radiation damage occurs. Data presented here show that cryo-cooling can cause some unexpected structural changes. Based on the results of this study, the integration of the plate scanner into the 19-ID end-station with automated controls is being prepared. With improvement of hardware and software, in situ data collection will become available for the SBC user program including remote access.

59 BASIC BIOLOGICAL SCIENCES↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

DAQs Quick Start Guide

DAQs is a Windows® computer app designed to communicate with the Advanced List Mode Module (ALMM), MC-15, and instrumentation based off these platforms. The ALMM communicates with DAQS over the Ethernet using TCP/IP. If you register the IPv4 address of the ALMM on the local network the ALMM can be operated remotely. However, if the ALMM is not connected to the local network then the computer running DAQs will need to be connected directly to the ALMM or an additional Ethernet adapter will need to be installed on the acquisition computer. The IPv4 address can be changed in the rei.ini file located on the µSD card. Please see the appendices for more information on the rei.ini file. This document is intended to be a quick start guide on how to get an ALMM connected to a computer and how to start a data acquisition. DAQs has much more capability than is presented in this document.

97 MATHEMATICS AND COMPUTING↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Requirements for high quality X-ray spectroscopy in an Explorer class mission

Through the use of simulated X-ray spectra the question of instrument requirements for a spectrograph that could significantly advance X-ray astronomy is addressed. It it concluded that resolution (lambda/delta lambda) in the range of 200 to 500, and effective collecting area in excess of 200 sq cm are required. One design, based on the objective reflection grating concept, which would meet these stringent requirements in an Explorer class mission is presented.

Cash, W. C., Jr.↗

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.↗

Avionics/crew station integration

The U.S. Navy has been encouraging advanced development concepts aimed at increasing the aircraft instrumentation performance for multi-platform applications of 1990's weapons systems. The three areas covered by the Navy's research and development effort are: System Integration, Technology, and Human Factors. The System Integration objectives are to produce a system architecture easily adaptable to many platforms. Technology objectives are to determine the state of the art for displays, electronics, and controls. The Human Factors objectives are to determine the proper human-machine interfaces so that the ultimate crew station will be capable of providing the pilot with the proper display and controls performance to satisfy the diverse requirements of a fighter, attack, ASW, fixed-wing, rotary-wing, and V/STOL platforms in both a one-man crew or two-man crew matrix. All data/control interface among units of this crew station and other platform subsystems will be via digital data buses and video multiplex buses. No individual discrete signal, data, or control lines will be needed. This paper discusses the six interfaces necessary to ensure the optimum development of this crew station, the predicted platform mission improvements, and the requisite life-cycle cost considerations. This concept will serve as a basis for planning the integration of the necessary hardware and software features in current and future weapons systems.

Mulley, W. G.↗

Observations of deep convection from an airborne high-frequency (92 and 183 GHz) passive microwave radiometer

Spencer et al. (1983) have reported that very low Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) brightness temperatures at 37 GHz over land coincide with heavy thunderstorm rainfall, while Wilheit et al. (1982) used an aircraft-mounted radiometer operating at 92 and 183 GHz to observe convective precipitation associated with a tropical storm over the ocean. A scanning version of the instrument employed by Wilheit et al. is the Advanced Microwave Moisture Sounder (AMMS). The present paper has the objective to summarize the preliminary results of AMMS observations of convective raining clouds and to determine whether empirical relationships between rain rate and microwave brightness temperature, such as those developed for 37 GHz satellite data by Spencer et al., can be extended to higher microwave frequencies.

Hakkarinen, I. M.↗

Unified constitutive materials model development and evaluation for high-temperature structural analysis applications

Unified constitutive material models were developed for structural analyses of aircraft gas turbine engine hot section components with particular application to an isotropic material used for combustor liners. Differential forms of models independently developed were considered in this study. These models combine the interactions of time-dependent (creep) and time-independent (plasticity) inelastic behavior of a material. Predicted stress-strain responses from these models were evaluated against cyclic isothermal and nonisothermal test results for uniaxial specimens of a nickel-base superalloy. The unified models were implemented in a nonlinear structural analysis code. Two unique NASA Lewis test facilities were used in the evaluation of the models for complex geometry specimens and evaluation of advanced temperature and high-temperature strain measurement instrumentation. Predicted nonlinear structural responses from one of the models for a flat plate and a segment of a conventional combustor liner are presented.

Thompson, R. L.↗

Aeronautical facility requirements into the 2,000's

This paper delineates and speculates upon aeronautical systems, trends, and requirements into the 2,000's and indicates ground facility capability enhancements which are needed to support these devlopments. New facility capabilities required include (1) higher Reynolds number at low speeds especially for the high-lift and vortex hazard problems, (2) low-disturbance, high-speed aerodynamic and hypersonic propulsion facilities for transition and mixing studies, (3) large-scale and relatively long test-time hypersonic propulsion tunnels to allow multidisciplinary integration, (4) a large-scale, high-speed acoustics facility for en route noise minimization, (5) a large-scale ballistic range for planetary entry studies, and (6) development of advanced (full simultaneous 3-space and time) nonintrusive instrumentation for CFD transition/turbulence modeling/code validation and interacting flow physics determination.

Beach, H. L., Jr.↗

Preliminary assessment of a supersonic STOVL flight research and demonstration aircraft

NASA Ames has conducted a conceptual design study of a supersonic short takeoff and vertical landing (STOVL) flight research and demonstration aircraft sized according to current technology levels. The aircraft would provide the capability for demonstrating advanced technologies required for STOVL and would be instrumented to provide temperature, pressure, and noise data for power-induced-effects research. The propulsion concept for the single-engine aircraft studied operates in mixed flow without thrust augmentation during power-lift flight. The study aircraft is full scale to facilitate STOVL propulsion-system component validation and power-induced aerodynamics research. Performance is sufficient to permit investigation and validation of vertical landing and hover, accelerating and decelerating transitions, short takeoff, reduced-weight vertical takeoff, and supersonic flight. Mission and maneuver capability is sufficient to demonstrate the operational utility of this class of aircraft. Aircraft mission and technology sensitivities were also examined.

Samuels, Jeffrey J.↗

Advanced Transport Operating Systems Program

NASA-Langley's Advanced Transport Operating Systems Program employs a heavily instrumented, B 737-100 as its Transport Systems Research Vehicle (TRSV). The TRSV has been used during the demonstration trials of the Time Reference Scanning Beam Microwave Landing System (TRSB MLS), the '4D flight-management' concept, ATC data links, and airborne windshear sensors. The credibility obtainable from successful flight test experiments is often a critical factor in the granting of substantial commitments for commercial implementation by the FAA and industry. In the case of the TRSB MLS, flight test demonstrations were decisive to its selection as the standard landing system by the ICAO.

White, John J.↗

Infrared (8-14 microns) remote sensing of soil particle size

Particle size of soils plays a significant role in erosion potential and other mechanical properties. Most soils are dominated by the residual mineral quartz, which displays prominent reststrahlen bands in the 8-14 microns atmospheric window. The Earth Observing System will likely provide world-wide multispectral imagery in the 8-14 microns region via the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument. The ratio of ASTER bands 10/14 can be used to estimate particle size in soils, if other ASTER bands are used to minimize the confusion factors provided by soil moisture, vegetation cover, soil organic content, and the presence of abundant minerals other than quartz. Use of band ratios minimizes the effects of poor surface temperature estimates, but maximizes the need for high signal-to-noise data.

Salisbury, John W.↗