Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Theoretical study on the effect of the design of small (milli-Newton) thruster jets on molecular contamination for the space station

The self-induced molecular contamination around the space station could have adverse effects on space station components (for example solar panels) as well as scientific experiments that might be done on or near the space station. Aerospace engineers need to design a space station (SS) propulsion system that keeps the SS in a stable orbit and at the same time does not allow the propellant gases to interfere with the experiments of the user. One scenario that might accomplish the above requirements is to use an electrothermal propulsion system, resistojet, that will thrust continuously in the hundreds of milli-Newton range which will provide a constant altitude for the SS with a low g environment. As a first attempt to understand the contamination from such a propulsion system, a point source model was developed. The numerical results of the point source model are given. Number column densities for CO2 are presented as a function of direction of observation (line of sight), temperature of the exit gas, and mean exit velocity. All the results are for a constant exhaust rate of 5,000 kg/year. In addition, a mathematical model to study the effect of nozzle design on the induced molecular environment around the space station produced by simple gas propellants is described. The mathematical model would allow one to follow the expansion of the gas from the throat of a nozzle to the nozzle exit plane and then into the space external to the nozzle.

Riley, B. R.↗

In vitro cytogenetic studies of organic chemicals found as contaminants in spacecraft cabin atmospheres

Astronauts can be exposed during spaceflight to organic chemical contaminants in the spacecraft cabin atmosphere. Toxic exposures may cause lesions in the cellular DNA which are subsequently expressed as sister-chromatid exchanges (SCE). Analysis of SCE is a sensitive short-term assay technique to detect and quantitate exposures to DNA-damaging (mutagenic) substances. The increase in SCE incidence over baseline (control) levels is generally proportional to the concentration of the mutagen and to the duration of exposure. Dichloromethane (methylene chloride) was chosen for this study since it occurred as an atmospheric contaminant in ten of the first 12 STS flights, and has been reported to have toxic and mutagenic effects in various test systems. Glutaraldehyde was chosen because relatively few data are available on the toxicity or mutagenicity of this common biological fixative, which is carried on STS flights for use in biological experiments. The BHK-21 baby hamster kidney cell line was the in vitro test system used in this study. Neither dichloromethane (10 ppm to 500 ppm) nor glutaraldehyde (1 ppm to 10 ppm) increased SCE levels following 20-hour exposure of BHK-21 cells to the test chemicals.

Torres, J.↗

Analysis of TQCM surface contamination adsorbed during the Spacelab I Mission

The Temperature-Controlled Quartz Crystal Microbalance (TQCM) system was flown on the Spacelab I Mission as part of the Induced Environment Contamination Monitor to monitor surface contamination (SC) in the payload bay. SC on the five sensors of the TQCM was analyzed by means of IR spectroscopy, scanning electron spectroscopy, and energy dispersive X-ray fluorescence. The amount of SC ranged from 1.4 micrograms/sq cm for the -Z sensor to 39.9 micrograms/sq cm for the +X sensor. The IR analysis showed strong CH2, CH3, and carbonyl absorption bands, indicative of ester and polyester compounds found in adhesives, plasticizers, and tape. The particulates (mostly ranging from 1 micron to 20 microns in size) were mainly composed of Mg, Al, Al2O3, and Si, and probably originated in the solid rocket firings.

Mckeown, D.↗

Acoustic reflection contamination measurements in the 16-foot NASA Langley Transonic Wind Tunnel

The Propfan Test Assessment (PTA) contract, awarded recently to Lockheed by the NASA-Lewis Research Center, required a comprehesive series of near field acoustic measurements. These were to use transducers mounted on the surfaces on a one-ninth scale model of the Gulfstream G-II aircraft, modified to the PTA single propfan testbed configuration. The 16-foot Transonic Wind Tunnel at the NASA Langley Research Center was chosen as the facility to be used for these model acoustic tests. Since the tunnel was hard-walled, it is not clear to what extent the propfan noise signals, reaching the various transducers, might be contaminated by reflections from the walls. A Multidriver Acoustic Source was built, and using an impulse and time domain averaging technique, the reflection contaminations in the wind tunnel were measured at selected microphone locations. Results of the investigations of near field measurements exists, due to reflections from the hard walls of the wind tunnnel.

Burrin, R. H.↗

Contamination-Free Electrical-Discharge Machining

Contamination of parts by electrical-discharge machining (EDM) almost completely eliminated by reversing flow of coolant. Flow reversed from usual direction so coolant carries contaminants out through passage in electrode. Coolant for reverse flow is pressurized dichlorodifluoromethane vapor.

Schmidt, Mark G.↗

Chemical contamination remote sensing

A ground mobile laser test bed system was assembled to assess the feasibility of detection of various types of chemical contamination using Differential Scattering (DISC) and Differential Absorption (DIAL) Lidar techniques. Field experiments with the test bed system using chemical simulants were performed. Topographic reflection and range resolved DIAL detection of vapors as well as DISC detection of aerosols and surface contamination were achieved. Review of detection principles, design of the test bed system, and results of the experiments are discussed.

Carrico, J. P.↗

Genetic toxicity studies of organic chemicals found as contaminants in spacecraft cabin atmospheres

Astronauts can be exposed during spaceflight to organic chemical contaminants in the spacecraft cabin atmosphere. Toxic exposures may cause lesions in the cellular DNA which are subsequently expressed as sister-chromatid exchanges (SCE). Analysis of SCE is a sensitive short term assay techinque to detect and quantitate exposures to DNA damaging (mutagenic) substances. The increase in SCE incidence over baseline (control) levels is generally proportional to the concentration of the mutagen and to the duration of exposure. The BHK-21 baby hamster kidney cell line was the in vitro test system used. Test organics were added to the culture media for 18 hrs, in concentrations ranging from one to 20 ppm. Acetaldehyde and carbon disulfide were chosen for this study since they have occurred as atmospheric contaminants in many of the STS flights, and have been reported to have toxic and mutagenic effects in various test systems. Glutaraldehyde was chosen because few data are available on the mutagenicity of this common fixative, which is carried on STS flights for use in biological experiments. Acetaldehyde was a very strong inducer of SCE at concentrations of 2 ppm and above. Glutaraldehyde and carbon disulfide failed to induce SCE.

Torres, Joseph, Jr.↗

Contamination Barrier For Contour-Molding Material

Release agent prevents molding compound from adhering to or contaminating surface. Cleaning agent, Turco 4215 NCLT, forms barrier preventing silicone molding compound from sticking to surface and leaving contaminating residue. Also see MFS-29243.

Adams, James F.↗

Space station contamination considerations

The external induced environment generated by space station activity, or more specifically by gases, particles, and light background is discussed. These contaminant species must be controlled if sensitive systems, such as solar energy collectors or science experiments exposed to the external environment are to function properly. The requirements generally set limits on the level of gas species, matter deposited on surfaces and light background levels over various spectral regions. They also address environment monitoring and contamination controls during manufacturing. Limits on effluent release and system leakages are in turn derived from these requirements.

Leger, L.↗

Analysis of contamination data recorded by the IECM camera/photometer

The Camera/Photometer was one of the ten instruments comprising the Induced Environment Contamination Monitor (IECM) developed to monitor the contamination about the Space Shuttle Orbiter during early missions. This experiment consisted of two motion picture cameras, integrating photometers, and associated electronics enclosed in pressurized canisters and separated by 40 cm in order to make stereoscopic observation of particulates. The objectives of the experiment were to record the occurrence of particulates and to determine their velocities, sizes and origins, as well as to measure the background brightness due to unresolved particles. Particle tracks were detected on over 1800 data frames recorded during continuous operations throughout STS-2, -3, -4, and -9. This report discusses the analysis techniques employed in reducing subsequent results, with an emphasis placed on particle size and velocity data. It also describes the operation of the overall experiment and some of the results obtained.

Clifton, K. Stuart↗

Preliminary study of niobium alloy contamination by transport through helium

Transport of gaseous contaminants through the working fluid to or from sensitive refractory alloys is theoretically possible during long time operation of Brayton and Stirling space power generation systems which use a gas as the working fluid. A test was designed which could give an answer to whether transport of contaminants through the working fluid was a potential major problem. The findings of that preliminary study are summarized.

Scheuermann, C. M.↗

Space station particulate contamination environment

The origin of particulate contamination on the Space Station will mostly be from pre-launch operations. The adherence and subsequent release of these particles during space flight are discussed. Particle size, release velocity, and release direction are important in determining particle behavior in the vicinity of the vehicle. The particulate environment at the principal science instrument locations is compared to the space shuttle bay environment. Recommendations for possibly decreasing the particulate contamination are presented.

Miller, E. R.↗

Optical contamination measurements on early Shuttle missions

Two camera/photometers were included as part of the Induced Environment Contamination Monitor on STS-2,-3,-4, and -9 orbital missions to record photographically Shuttle-induced particulate and background contamination. The cameras collected stereoscopic data continuously during the on-orbit phases of these missions making exposures every 150 s. The results recorded throughout a 32-deg field-of-view indicate high particle concentrations during early mission operations. These decay to a quiescent rate of 500 particles of greater than 10-micron radius observed per orbit. Preliminary size and velocity distributions of measured particles are presented as are measurements of background brightness due to unresolved particles in the visible spectral region.

Clifton, K. Stuart↗

AIS radiometry and the problem of contamination from mixed spectral orders

The spectral radiance of test areas under solar illumination is ascertained in view of Airborne Imaging Spectrometer (AIS) data from Mono Lake, CA, establishing an atmospheric correction method for major absorbers on the basis of the spectrometric data themselves. The apparent low contrast of all atmospheric absorption bands leads to a study of contamination from overlapping spectral orders in the AIS data; this contamination is found unambiguously above 1500 nm with a magnitude that is a factor of 1.5-2.0 greater than the expected uncontaminated signal alone.

Conel, J. E.↗