Search NASA⌕ Search

SEARCH · Search NASA

Results for “Continuous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Continuous Emulation and Multiscale Visualization of Traffic Flow Using Stationary Roadside Sensor Data

With the advent of the next-generation traffic monitoring systems, there has been a significant increase in the spatial-temporal resolution of vehicle mobility data in many cities. Effective analysis and visualization of such data can provide transportation planners with data-driven insights, which can facilitate the understanding of multiscale traffic dynamics. In this paper, we present a web-based traffic emulator for emulating and visualizing near-real-time and historical traffic flows on highways using data from road-side sensors. To construct a continuous traffic flow, the emulator adopts an analytical pipeline that can (a) integrate traffic data collected from discrete road-side radar detection sensors, (b) interpolate traffic conditions (vehicle speed and volume) on unmeasured road segments based on traffic flow theory, and (c) generate lane-specific vehicle trajectories and movements using a mathematically optimized representation of the road network. Our app also provides an integrated visual workflow that allows users to explore the interconnected traffic dynamics using an appropriate traffic flow visualization selected based on the level of detail. We devise two innovative geo-visualization techniques that utilize an animated strips-network representation and a lane usage matrix to visualize lane performances. To ensure a smooth emulation of large-scale traffic flow in an easy-to-access web environment, we implement the emulator using client-side GPU-accelerated techniques. Lastly, we close with a case study that visualizes traffic dynamics of two scenarios - an afternoon peak hour and a traffic accident - in Chattanooga, Tennessee. Our app visualizes the responses of traffic dynamics during different traffic conditions, and to the presence of the traffic accident at different spatial scales.

42 ENGINEERING↗

Transformations based on continuous piecewise-affine velocity fields

Here, we propose novel finite-dimensional spaces of well-behaved Rn → Rn transformations. The latter are obtained by (fast and highly-accurate) integration of continuous piecewise-affine velocity fields. The proposed method is simple yet highly expressive, effortlessly handles optional constraints (e.g., volume preservation and/or boundary conditions), and supports convenient modeling choices such as smoothing priors and coarse-to-fine analysis. Importantly, the proposed approach, partly due to its rapid likelihood evaluations and partly due to its other properties, facilitates tractable inference over rich transformation spaces, including using Markov-Chain Monte-Carlo methods. Its applications include, but are not limited to: monotonic regression (more generally, optimization over monotonic functions); modeling cumulative distribution functions or histograms; time-warping; image warping; image registration; real-time diffeomorphic image editing; data augmentation for image classifiers. Our GPU-based code is publicly available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kinetic and stoichiometric characterization of organoautotrophic growth of R alstonia eutropha on formic acid in fed‐batch and continuous cultures

Summary Formic acid, acting as both carbon and energy source, is a safe alternative to a carbon dioxide, hydrogen and dioxygen mix for studying the conversion of carbon through the C alvin– B enson– B assham ( CBB ) cycle into value‐added chemical compounds by non‐photosynthetic microorganisms. In this work, organoautotrophic growth of R alstonia eutropha on formic acid was studied using an approach combining stoichiometric modeling and controlled cultures in bioreactors. A strain deleted of its polyhydroxyalkanoate production pathway was used in order to carry out a physiological characterization. The maximal growth yield was determined at 0.16 C mole C mole −1 in a formate‐limited continuous culture. The measured yield corresponded to 76% to 85% of the theoretical yield (later confirmed in pH ‐controlled fed‐batch cultures). The stoichiometric study highlighted the imbalance between carbon and energy provided by formic acid and explained the low growth yields measured. Fed‐batch cultures were also used to determine the maximum specific growth rate (μ max = 0.18 h −1 ) and to study the impact of increasing formic acid concentrations on growth yields. High formic acid sensitivity was found in R eutropha since a linear decrease in the biomass yield with increasing residual formic acid concentrations was observed between 0 and 1.5 g l −1 .

Grunwald, Stephan↗

Integrating continuous hypermutation with high–throughput screening for optimization of cis,cis –muconic acid production in yeast

Directed evolution is a powerful method to optimize proteins and metabolic reactions towards user-defined goals. It usually involves subjecting genes or pathways to iterative rounds of mutagenesis, selection and amplification. While powerful, systematic searches through large sequence-spaces is a labour-intensive task, and can be further limited by a priori knowledge about the optimal initial search space, and/or limits in terms of screening throughput. Here, we demonstrate an integrated directed evolution workflow for metabolic pathway enzymes that continuously generate enzyme variants using the recently developed orthogonal replication system, OrthoRep and screens for optimal performance in high-throughput using a transcription factor-based biosensor. We demonstrate the strengths of this workflow by evolving a rate-limiting enzymatic reaction of the biosynthetic pathway for cis,cis-muconic acid (CCM), a precursor used for bioplastic and coatings, in Saccharomyces cerevisiae. After two weeks of simply iterating between passaging of cells to generate variant enzymes via OrthoRep and high-throughput sorting of best-performing variants using a transcription factor-based biosensor for CCM, we ultimately identified variant enzymes improving CCM titers > 13-fold compared with reference enzymes. Taken together, the combination of synthetic biology tools as adopted in this study is an efficient approach to debottleneck repetitive workflows associated with directed evolution of metabolic enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Continuous cultivation of the lithoautotrophic nitrate‐reducing Fe( II )‐oxidizing culture KS in a chemostat bioreactor

Abstract Laboratory‐based studies on microbial Fe(II) oxidation are commonly performed for 5–10 days in small volumes with high substrate concentrations, resulting in geochemical gradients and volumetric effects caused by sampling. We used a chemostat to enable uninterrupted supply of medium and investigated autotrophic nitrate‐reducing Fe(II)‐oxidizing culture KS for 24 days. We analysed Fe‐ and N‐speciation, cell‐mineral associations, and the identity of minerals. Results were compared to batch systems (50 and 700 mL—static/shaken). The Fe(II) oxidation rate was highest in the chemostat with 7.57 mM Fe(II) d −1 , while the extent of oxidation was similar to the other experimental setups (average oxidation of 92% of all Fe(II)). Short‐range ordered Fe(III) phases, presumably ferrihydrite, precipitated and later goethite was detected in the chemostat. The 1 mM solid phase Fe(II) remained in the chemostat, up to 15 μM of reactive nitrite was measured, and 42% of visualized cells were partially or completely mineral‐encrusted, likely caused by abiotic oxidation of Fe(II) by nitrite. Despite (partial) encrustation, cells were still viable. Our results show that even with similar oxidation rates as in batch cultures, cultivating Fe(II)‐oxidizing microorganisms under continuous conditions reveals the importance of reactive nitrogen intermediates on Fe(II) oxidation, mineral formation and cell–mineral interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Model-averaged benchmark concentration estimates for continuous response data arising from epidemiological studies

Worker populations often provide data on adverse responses associated with exposure to potential hazards. The relationship between hazard exposure levels and adverse response can be modeled and then inverted to estimate the exposure associated with some specified response level. One concern is that this endpoint may be sensitive to the concentration metric and other variables included in the model. Further, it may be that the models yielding different risk endpoints are all providing relatively similar fits. We focus on evaluating the impact of exposure on a continuous response by constructing a model-averaged benchmark concentration from a weighted average of model-specific benchmark concentrations. A method for combining the estimates based on different models is applied to lung function in a cohort of miners exposed to coal dust. In this analysis, we see that a small number of the thousands of models considered survive a filtering criterion for use in averaging. Even after filtering, the models considered yield benchmark concentrations that differ by a factor of 2 to 9 depending on the concentration metric and covariates. The model-average BMC captures this uncertainty, and provides a useful strategy for addressing model uncertainty.

01 COAL, LIGNITE, AND PEAT↗

Prediction of continuous porosity gradients in ceramics using ZnO as a model material

Materials with gradient microstructures have a wide range of applications such as cutting tools, armor, and electronic devices. However, it is difficult to predict and control the gradient microstructure during processing. In the present work, a continuous porosity gradient was successfully achieved in ZnO material via spark plasma sintering with a large induced thermal gradient. The porosity is overestimated if isothermal prediction is applied. The current work proposed a more accurate prediction of the porosity by considering the stress-shielding effect caused by the thermal gradient. The shielding effect results from different stress states in the sample due to differential sintering: the hotter side of the specimen experiences a higher strain rate and more shrinkage while the colder side experiences a lower strain rate and less shrinkage simultaneously. Therefore, the axial strains are varied throughout the sample thickness. Using the constituent equations in advanced sintering analysis, the shield stress was calculated to be approximately 13 MPa for the viscoelastic assumption of sintering. To improve the accuracy of predicting porosity gradient, it is necessary to add a load to overcome the shield stress when the materials are sintered with a thermal gradient.

36 MATERIALS SCIENCE↗

A comparative study of cerium oxides formed by pulsed laser ablation and continuous wave laser heating

Abstract The formation of Ce 2 O 3 from cerium metal requires complex reducing conditions. Alternatively, we show that different stoichiometries and structures of cerium oxides can be generated in high‐temperature laser experiments by varying the availability of oxygen and the use of either pulsed laser ablation (PLA) or continuous wave (CW) laser heating of cerium metal. X‐ray diffraction and Raman spectroscopy suggest that a low structural order Ce 2 O 3 /CeO 2 mixed structure is formed in a 1% O 2 atmosphere with PLA. For CW heating in a 1% O 2 environment, Raman measurements show the formation of crystalline A‐type Ce 2 O 3 in proximity to the point of laser impingement. These experiments were repeated in 18 O 2 and allowed us to report for the first time the corresponding Raman spectrum of Ce 2 18 O 3 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the continuity of solutions to anisotropic elliptic operators in the limiting case

Abstract We show that local weak solutions to anisotropic elliptic equations with bounded and measurable coefficients, whose prototype is are continuous. Our analysis exploits a particular intrinsic geometry that, within the limiting case on the exponents, allows for a reduction of the oscillation of the solution.

Ciani, Simone [Department of Mathematics, Universi↗

Continuous production of nanostructured particles using spatial atomic layer deposition

In this paper, the authors demonstrate a novel spatial atomic layer deposition (ALD) process based on pneumatic transport of nanoparticle agglomerates. Nanoclusters of platinum (Pt) of ∼1 nm diameter are deposited onto titania (TiO{sub 2}) P25 nanoparticles resulting to a continuous production of an active photocatalyst (0.12–0.31 wt. % of Pt) at a rate of about 1 g min{sup −1}. Tuning the precursor injection velocity (10–40 m s{sup −1}) enhances the contact between the precursor and the pneumatically transported support flows. Decreasing the chemisorption temperature (from 250 to 100 °C) results in more uniform distribution of the Pt nanoclusters as it decreases the reaction rate as compared to the rate of diffusion into the nanoparticle agglomerates. Utilizing this photocatalyst in the oxidation reaction of Acid Blue 9 showed a factor of five increase of the photocatalytic activity compared to the native P25 nanoparticles. The use of spatial particle ALD can be further expanded to deposition of nanoclusters on porous, micron-sized particles and to the production of core–shell nanoparticles enabling the robust and scalable manufacturing of nanostructured powders for catalysis and other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking

A proton beam delivery system on a gantry with continuous uniform scanning and dose layer stacking at the Midwest Proton Radiotherapy Institute has been commissioned and accepted for clinical use. This paper was motivated by a lack of guidance on the testing and characterization for clinical uniform scanning systems. As such, it describes how these tasks were performed with a uniform scanning beam delivery system. This paper reports the methods used and important dosimetric characteristics of radiation fields produced by the system. The commissioning data include the transverse and longitudinal dose distributions, penumbra, and absolute dose values. Using a 208 MeV cyclotron's proton beam, the system provides field sizes up to 20 and 30 cm in diameter for proton ranges in water up to 27 and 20 cm, respectively. The dose layer stacking method allows for the flexible construction of spread-out Bragg peaks with uniform modulation of up to 15 cm in water, at typical dose rates of 1-3 Gy/min. For measuring relative dose distributions, multielement ion chamber arrays, small-volume ion chambers, and radiographic films were employed. Measurements during the clinical commissioning of the system have shown that the lateral and longitudinal dose uniformity of 2.5% or better can be achieved for all clinically important field sizes and ranges. The measured transverse penumbra widths offer a slight improvement in comparison to those achieved with a double scattering beam spreading technique at the facility. Absolute dose measurements were done using calibrated ion chambers, thermoluminescent and alanine detectors. Dose intercomparisons conducted using various types of detectors traceable to a national standards laboratory indicate that the measured dosimetry data agree with each other within 5%.

43 PARTICLE ACCELERATORS↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

Kilovoltage energy imaging with a radiotherapy linac with a continuously variable energy range

Purpose: In this paper, the effect on image quality of significantly reducing the primary electron energy of a radiotherapy accelerator is investigated using a novel waveguide test piece. The waveguide contains a novel variable coupling device (rotovane), allowing for a wide continuously variable energy range of between 1.4 and 9 MeV suitable for both imaging and therapy.Method: Imaging at linac accelerating potentials close to 1 MV was investigated experimentally and via Monte Carlo simulations. An imaging beam line was designed, and planar and cone beam computed tomography images were obtained to enable qualitative and quantitative comparisons with kilovoltage and megavoltage imaging systems. The imaging beam had an electron energy of 1.4 MeV, which was incident on a water cooled electron window consisting of stainless steel, a 5 mm carbon electron absorber and 2.5 mm aluminium filtration. Images were acquired with an amorphous silicon detector sensitive to diagnostic x-ray energies. Results: The x-ray beam had an average energy of 220 keV and half value layer of 5.9 mm of copper. Cone beam CT images with the same contrast to noise ratio as a gantry mounted kilovoltage imaging system were obtained with doses as low as 2 cGy. This dose is equivalent to a single 6 MV portal image. While 12 times higher than a 100 kVp CBCT system (Elekta XVI), this dose is 140 times lower than a 6 MV cone beam imaging system and 6 times lower than previously published LowZ imaging beams operating at higher (4-5 MeV) energies. Conclusions: The novel coupling device provides for a wide range of electron energies that are suitable for kilovoltage quality imaging and therapy. The imaging system provides high contrast images from the therapy portal at low dose, approaching that of gantry mounted kilovoltage x-ray systems. Additionally, the system provides low dose imaging directly from the therapy portal, potentially allowing for target tracking during radiotherapy treatment. There is the scope with such a tuneable system for further energy reduction and subsequent improvement in image quality.

43 PARTICLE ACCELERATORS↗

A contactless approach for respiratory gating in PET using continuous-wave radar

Purpose: Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient’s torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. Methods: The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient’s torso. A 24 GHz carrier frequency was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [{sup 18}F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. Results: The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69–0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53–0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin. Conclusions: Accurate respiratory signals were obtained successfully by the proposed method with high spatial and temporal resolution. By working without contact and passing through clothing and blankets, this approach minimizes preparation time and increases the convenience of the patient during the scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal pulse sequence modifications and no additional scan time, improving ASL’s clinical applicability.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-13: Continuous Intra-Fractional Monitoring of the Prostate Using Dynamic KV Collimation and Tube Current Modulation

Purpose: The focus of this work is to improve the available kV image quality for continuous intra-fraction monitoring of the prostate. This is investigated using a novel blade collimation system enabling modulated volume-of-interest (VOI) imaging of prostate fiducial markers. Methods: A four-blade dynamic kV collimator was used to track a VOI during gantry rotation. Planar image quality was investigated as a function of collimator dimension, while maintaining the same dose to isocenter, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert. A sample prostate anatomy was defined in the planning system, including three fiducial markers within the CTV. The VOI margin around each marker was set to be 2σ of the population covariance matrix characterizing prostate motion. DRRs were used to calculate the kV attenuation for each VOI as a function of angle. The optimal marker and tube current were determined using kV attenuation. Monte Carlo simulations were used to calculate the imaging dose to the phantom and MV scatter dose to the imaging panel. Results: Preliminary measurements show an increase in CNR by a factor of 1.3 with the VOI method, when decreasing from an 6×6 to 2×2 cm{sup 2} field. Attenuation calculations show a change in kV fluence at the detector by a factor of 21.6 with fiducial optimization; resultant tube current modulation increases maximum dose by a factor of 1.4 compared to no modulation. MV scatter contribution to the kV detector changes by approximately a factor of two over a complete gantry rotation. Conclusion: The dynamic collimation system allows single fiducial marker tracking at a very low dose, with reduction of scatter and improvement of image quality, compared to imaging the entire prostate. The approach is compatible with tube current modulation, which enables consistent image quality throughout the range of gantry rotation. This project was funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Design of continuously graded elastic acoustic cloaks

Here, this letter demonstrates the design of continuously graded elastic cylinders to achieve passive cloaking from harmonic acoustic excitation, both at single frequencies and over extended bandwidths. The constitutive parameters in a multilayered, constant-density cylinder are selected in a partial differential equation-constrained optimization problem, such that the residual between the pressure field from an unobstructed spreading wave in a fluid and the pressure field produced by the cylindrical inclusion is minimized. The radial variation in bulk modulus appears fundamental to the cloaking behavior, while the shear modulus distribution plays a secondary role. Such structures could be realized with functionally-graded elastic materials.

42 ENGINEERING↗

Polyolefin blends with co-continuous architectures enabled by dynamic covalent crosslinking

Blending polymers produces brittle materials due to macrophase separation and poor interfacial adhesion, which is exemplified by mixtures of polyolefins. This presents a formidable challenge for the mechanical recycling of mixed plastic waste. Here, we demonstrate that dynamic covalent crosslinking of immiscible polyolefin blends creates macrophase separated co-continuous architectures, yet they display excellent mechanical properties, which challenges the conventional wisdom regarding morphology-property relationships in polymer blend compatibilization. We find that the position and orientation of dynamic crosslinks and their influence on crystallinity are key to understanding the structure-morphology-property relationships. In particular, high-resolution microscopy imaging reveals alignment of crystallite planes with strong orientational preference, particularly at polymer-polymer interfaces, which contribute to material performance. We further demonstrate that changes in crosslinker density and valency allow the properties of binary and ternary polyolefin blends to be tuned in a modular fashion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗