Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

LANL Meteorological Program Improvements to Continue Meeting Annual 90 Percent Data Recovery Requirements

Recently, the Los Alamos National Laboratory (LANL) Environmental Protection and Compliance (EPC) and Safety Basis (SB) Divisions have collaborated on the latter’s use of the meteorological data as input into dispersion analysis used to determine receptor dose consequences as a result of an accidental release of radioactive material from a LANL nuclear facility. The dose consequence calculations are part of the Department of Energy (DOE) approved Documented Safety Analysis (DSA), which describes the processes, hazards, and controls of nuclear operations within certain facilities at LANL. The DOE approved DSA is required according to Title 10 of the Code of Federal Regulations Part 830 (10CFR830), “Nuclear Safety Management” and is developed in accordance with the 10CFR830, Subpart B “Safety Basis” safe harbor methodology identified as DOE Standard 3009-94, or successor document (DOE STD 3009-94).

54 ENVIRONMENTAL SCIENCES↗

Space Radiation Cancer Risk Projections and Uncertainties - 2010

Uncertainties in estimating health risks from galactic cosmic rays greatly limit space mission lengths and potential risk mitigation evaluations. NASA limits astronaut exposures to a 3% risk of exposure-induced death and protects against uncertainties using an assessment of 95% confidence intervals in the projection model. Revisions to this model for lifetime cancer risks from space radiation and new estimates of model uncertainties are described here. We review models of space environments and transport code predictions of organ exposures, and characterize uncertainties in these descriptions. We summarize recent analysis of low linear energy transfer radio-epidemiology data, including revision to Japanese A-bomb survivor dosimetry, longer follow-up of exposed cohorts, and reassessments of dose and dose-rate reduction effectiveness factors. We compare these projections and uncertainties with earlier estimates. Current understanding of radiation quality effects and recent data on factors of relative biological effectiveness and particle track structure are reviewed. Recent radiobiology experiment results provide new information on solid cancer and leukemia risks from heavy ions. We also consider deviations from the paradigm of linearity at low doses of heavy ions motivated by non-targeted effects models. New findings and knowledge are used to revise the NASA risk projection model for space radiation cancer risks.

Cucinotta, Francis A.↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program Mixing-Cell Model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS).

99 GENERAL AND MISCELLANEOUS↗

The first clinical implementation of electromagnetic transponder-guided MLC tracking

Purpose: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic transponder-guided MLC tracking which occurred on 28 November 2013 at the Northern Sydney Cancer Centre. Methods: An electromagnetic transponder-based positioning system (Calypso) was modified to send the target position output to in-house-developed MLC tracking code, which adjusts the leaf positions to optimally align the treatment beam with the real-time target position. Clinical process and quality assurance procedures were developed and performed. The first clinical implementation of electromagnetic transponder-guided MLC tracking was for a prostate cancer patient being treated with dual-arc VMAT (RapidArc). For the first fraction of the first patient treatment of electromagnetic transponder-guided MLC tracking we recorded the in-room time and transponder positions, and performed dose reconstruction to estimate the delivered dose and also the dose received had MLC tracking not been used. Results: The total in-room time was 21 min with 2 min of beam delivery. No additional time was needed for MLC tracking and there were no beam holds. The average prostate position from the initial setup was 1.2 mm, mostly an anterior shift. Dose reconstruction analysis of the delivered dose with MLC tracking showed similar isodose and target dose volume histograms to the planned treatment and a 4.6% increase in the fractional rectal V{sub 60}. Dose reconstruction without motion compensation showed a 30% increase in the fractional rectal V{sub 60} from that planned, even for the small motion. Conclusions: The real-time beam-target correction method, electromagnetic transponder-guided MLC tracking, has been translated to the clinic. This achievement represents a milestone in improving geometric and dosimetric accuracy, and by inference treatment outcomes, in cancer radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity differences between primary and lymphoma tumor by multi-scale image texture analysis. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned paper is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low Earth orbit for science, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low Earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with eight Teledyne µDosimeters over varying shielding effectivenesses. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 – AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat three unit (3U) models. Using NOVICE model radiation analysis coding, the shielding effectivenesses, based on a generic CubeSat 3U structure with four electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cm to 4.44 cm (0.550 g/cm 2 to 12.0 g/cm 2 ). For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID) increases by nearly a magnitude for thin-walled aluminum 0.550-g/cm 2 - 0.686-g/cm 2 (0.204-cm – 0.254-cm) typical CubeSat structures. The shielding effectiveness estimated by NOVICE Sigma, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one-year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from the Earth’s magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast to a thin-walled generic 3U CubeSat, the Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm 2 from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the mission value of the spacecraft versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein

Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions, which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. - Highlights: • Screened 146 serum samples for measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb). • MV nAb is prevalent in the sera. • CDV neutralizing activity is generally low or absent and when detected it is present in sera with high MV nAb titers. • A neutralization-resistant CDV mutant was isolated using human serum selection. • A mutation was identified in the receptor-binding region of CDV hemagglutinin protein that confers the neutralization resistance.

60 APPLIED LIFE SCIENCES↗

A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications

In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy, and in vivo dose monitoring. Investigations that have been performed using GEANT4 only are also mentioned to illustrate the potential of GATE. The very practical feature of GATE making it easy to model both a treatment and an imaging acquisition within the same frameworkis emphasized. The computational times associated with several applications are provided to illustrate the practical feasibility of the simulations using current computing facilities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing efficiency of BEAMnrc-simulated Co-60 beams using directional source biasing

Purpose: This study describes the implementation of a directional source biasing (DSB) scheme for efficiently simulating Cobalt-60 treatment heads using the BEAMnrc Monte Carlo code. Previous simulation of Co-60 beams with BEAMnrc was impractical because of the time required to track photons not directed into the treatment field and to simulate secondary charged particles. Methods: In DSB, efficiency is increased by splitting each photon emitted by the Co-60 source a user-defined number of times. Only those split primary photons directed into a user-defined splitting field (encompassing the treatment field) are sampled, yielding many low-weight photons directed into the field. Efficiency can be further increased by taking advantage of radial symmetry at the top of the treatment head to reduce the number of split primary photons tracked in this portion. There is also an option to generate contaminant electrons in DSB. Results: The DSB scheme in BEAMnrc increases the photon fluence calculation efficiency in a 10 × 10 cm{sup 2} Co-60 beam by a factor of 1800 with a concurrent increase in contaminant electron fluence calculation efficiency by a factor of 1200. Implementation of DSB in beampp, a C++ code for accelerator simulations based on EGSnrc and the C++ class library, egspp, increases photon fluence efficiency by a factor of 2800 and contaminant electron fluence efficiency by a factor of 1600. Optimum splitting numbers are in the range of 20 000–40 000. For dose calculations in a water phantom (0.5 × 0.5 × 0.5 cm{sup 3} voxels) this translates into a factor of ∼400 increase in dose calculation efficiency (all doses > 0.5 × D{sub max}). An example calculation of the ratio of dose to water to dose to chamber (the basis of the beam quality correction factor) to within 0.2% in a realistic chamber using a full simulation of a Co-60 treatment head as a source indicates the practicality of Co-60 simulations with DSB. Conclusions: The efficiency improvement resulting from DSB makes Monte Carlo commissioning of Co-60 beams and calculation of beam quality correction factors feasible.

60 APPLIED LIFE SCIENCES↗

Compendium of Single Event Transient (SET) and Total Ionizing Dose (TID) Test Results for Commonly Used Voltage Comparators

This data compendium reports single event transient (SET) and total ionizing dose (TID) test results for commonly used commercial-off-the-shelf (COTS) and radiation hardened voltage comparators targeted for possible use in space-based missions. Interesting trends in the variability of the radiation performance of these devices due to differences in lot date codes, manufacturers, circuit design, and test conditions are analyzed herein.

Bozovich, Amanda↗

SU-F-J-209: Quantification of Image-Guidance Benefit in Image-Guided Radiotherapy of Cancers

Purpose: Image-guidance has been widely used in radiation oncology for accurate radiotherapy. The goal of this study is to quantify the benefit of image-guidance in image-guided radiotherapy (IGRT) of cancers. Methods: In this study, a new index termed image-guidance benefit (IGB), was proposed to quantify the benefit of image-guidance in cancer radiotherapy. It is calculated as a ratio of the square sum of dose differences between planning dose matrix and actual delivery dose matrix post image-guidance to the square sum of dose summation between the two matrixes, summing over all dose scoring voxels. Ranging from 0 to 1, larger IGB values indicate larger benefit out of image-guidance. With IRB approval, the DICOM RT files and 3D couch shifts applied during IGRT of 2219 patients were collected, based on which patient-specific IGB values were calculated with an in-house MATLAB code. Results: In this study, the mean IGB value was found to be 0.0398 (0.000583–0.999) with a positive correlation between IGB value and 3D couch shift vector at 0.0435 per cm (P<0.0001). With 2 mm shift as a threshold above which an image-guidance is deemed clinically necessary, the corresponding mean IGB value was 0.00457, much less than 0.0398 (P<0.001). However, the IGB values of 56 cases based on couch shifts were less than those based on 2 mm shift. Conclusion: The IGB values were patient-specific and site-dependent. Using 2 mm shifts as criterion for applying image-guidance, the applied image-guidance procedures were found clinically necessary and highly beneficial in 97.5% of cancer patients. However, image-guidance procedures were found over-used in about 2.5% of cancer patients in our current practices of IGRT, which should be avoided as they added no benefit in improving delivery accuracy while increasing cancer risk.

60 APPLIED LIFE SCIENCES↗

MACCS Theory Manual

This report describes the models of the MACCS computer code as presented in MACCS Version 3.10.0. The purpose of MACCS is to simulate the impact of severe accidents at nuclear power plants on the surrounding environment. MACCS has been developed by Sandia National Laboratories for the U.S. Nuclear Regulatory Commission. From a given release of radioactive material into the atmosphere, MACCS estimates the extent and magnitude of radiological contamination, offsite doses, protective actions, socioeconomic impacts and costs, and health effects. Since the weather at the time of an accident is not predictable, MACCS supports various sampling options to run a representative set of simulations to evaluate weather variability. MACCS simulates atmospheric transport with a straight-line Gaussian plume segment model. From the estimated air and ground concentrations, MACCS models dose projections through several dose exposure pathways. These exposures can be offset by protective actions during the emergency response and long-term recovery of the accident. MACCS users directly specify the evacuation and sheltering area, while other protective actions (e.g., relocation, farmland restrictions, decontamination) are based on user-specified dose or concentration limits. While protective actions help reduce dose accumulation, they also cause social and economic impacts. MACCS models the extent of displaced individuals and land contamination, and the cost of offsite property damage, economic disruptions, and various accident expenditures caused by protective actions. Finally, from the dose accumulation, MACCS estimates early and stochastic health effects according to dose-response models. The purpose of consequence analyses is to be able to understand and estimate the impact of nuclear accidents. Consequence analysis is an essential tool to inform determinations of adequate protection of the public, to understand nuclear power hazards, to measure the value of regulations, and to help us appreciate the importance of nuclear safety. As such, MACCS has a variety of regulatory uses including environmental analyses (10 CFR 51.53, 52.47), regulatory cost-benefit analyses, backfit analyses (10 CFR 50.109), consequence analysis studies such as SOARCA (NUREG-1935), Level 3 PRA studies, and risk-informing of emergency planning (10 CFR 50 App. E and 50.47). This report updates the previous MACCS theory manual (NUREG/CR-4691 Vol. 2; Chanin, Sprung, Ritchie, & Jow, 1990) and accompanies the MACCS User's Guide (SAND-2021-1588) that describes the use and input requirements of the graphical user interface of MACCS known as WinMACCS. The MACCS User's Guide is also a reference guide that describes data input file formats, describes various software components in the MACCS code suite, and provides a set of example tutorials for running WinMACCS. Also, soon to be published is a MACCS input parameter guidance report (NUREG/CR-7270) that provides technical bases for commonly used MACCS input values. This page left blank

97 MATHEMATICS AND COMPUTING↗

Development of a Space Radiation Monte-Carlo Computer Simulation Based on the FLUKE and Root Codes

The radiation environment in space is a complex problem to model. Trying to extrapolate the projections of that environment into all areas of the internal spacecraft geometry is even more daunting. With the support of our CERN colleagues, our research group in Houston is embarking on a project to develop a radiation transport tool that is tailored to the problem of taking the external radiation flux incident on any particular spacecraft and simulating the evolution of that flux through a geometrically accurate model of the spacecraft material. The output will be a prediction of the detailed nature of the resulting internal radiation environment within the spacecraft as well as its secondary albedo. Beyond doing the physics transport of the incident flux, the software tool we are developing will provide a self-contained stand-alone object-oriented analysis and visualization infrastructure. It will also include a graphical user interface and a set of input tools to facilitate the simulation of space missions in terms of nominal radiation models and mission trajectory profiles. The goal of this project is to produce a code that is considerably more accurate and user-friendly than existing Monte-Carlo-based tools for the evaluation of the space radiation environment. Furthermore, the code will be an essential complement to the currently existing analytic codes in the BRYNTRN/HZETRN family for the evaluation of radiation shielding. The code will be directly applicable to the simulation of environments in low earth orbit, on the lunar surface, on planetary surfaces (including the Earth) and in the interplanetary medium such as on a transit to Mars (and even in the interstellar medium). The software will include modules whose underlying physics base can continue to be enhanced and updated for physics content, as future data become available beyond the timeframe of the initial development now foreseen. This future maintenance will be available from the authors of FLUKA as part of their continuing efforts to support the users of the FLUKA code within the particle physics community. In keeping with the spirit of developing an evolving physics code, we are planning as part of this project, to participate in the efforts to validate the core FLUKA physics in ground-based accelerator test runs. The emphasis of these test runs will be the physics of greatest interest in the simulation of the space radiation environment. Such a tool will be of great value to planners, designers and operators of future space missions, as well as for the design of the vehicles and habitats to be used on such missions. It will also be of aid to future experiments of various kinds that may be affected at some level by the ambient radiation environment, or in the analysis of hybrid experiment designs that have been discussed for space-based astronomy and astrophysics. The tool will be of value to the Life Sciences personnel involved in the prediction and measurement of radiation doses experienced by the crewmembers on such missions. In addition, the tool will be of great use to the planners of experiments to measure and evaluate the space radiation environment itself. It can likewise be useful in the analysis of safe havens, hazard migration plans, and NASA's call for new research in composites and to NASA engineers modeling the radiation exposure of electronic circuits. This code will provide an important complimentary check on the predictions of analytic codes such as BRYNTRN/HZETRN that are presently used for many similar applications, and which have shortcomings that are more easily overcome with Monte Carlo type simulations. Finally, it is acknowledged that there are similar efforts based around the use of the GEANT4 Monte-Carlo transport code currently under development at CERN. It is our intention to make our software modular and sufficiently flexible to allow the parallel use of either FLUKA or GEANT4 as the physics transport engine.

Pinsky, L. S.↗

On determining dose rate constants spectroscopically

Purpose: To investigate several aspects of the Chen and Nath spectroscopic method of determining the dose rate constants of {sup 125}I and {sup 103}Pd seeds [Z. Chen and R. Nath, Phys. Med. Biol. 55, 6089-6104 (2010)] including the accuracy of using a line or dual-point source approximation as done in their method, and the accuracy of ignoring the effects of the scattered photons in the spectra. Additionally, the authors investigate the accuracy of the literature's many different spectra for bare, i.e., unencapsulated {sup 125}I and {sup 103}Pd sources. Methods: Spectra generated by 14 {sup 125}I and 6 {sup 103}Pd seeds were calculated in vacuo at 10 cm from the source in a 2.7 Multiplication-Sign 2.7 Multiplication-Sign 0.05 cm{sup 3} voxel using the EGSnrc BrachyDose Monte Carlo code. Calculated spectra used the initial photon spectra recommended by AAPM's TG-43U1 and NCRP (National Council of Radiation Protection and Measurements) Report 58 for the {sup 125}I seeds, or TG-43U1 and NNDC(2000) (National Nuclear Data Center, 2000) for {sup 103}Pd seeds. The emitted spectra were treated as coming from a line or dual-point source in a Monte Carlo simulation to calculate the dose rate constant. The TG-43U1 definition of the dose rate constant was used. These calculations were performed using the full spectrum including scattered photons or using only the main peaks in the spectrum as done experimentally. Statistical uncertainties on the air kerma/history and the dose rate/history were Less-Than-Or-Slanted-Equal-To 0.2%. The dose rate constants were also calculated using Monte Carlo simulations of the full seed model. Results: The ratio of the intensity of the 31 keV line relative to that of the main peak in {sup 125}I spectra is, on average, 6.8% higher when calculated with the NCRP Report 58 initial spectrum vs that calculated with TG-43U1 initial spectrum. The {sup 103}Pd spectra exhibit an average 6.2% decrease in the 22.9 keV line relative to the main peak when calculated with the TG-43U1 rather than the NNDC(2000) initial spectrum. The measured values from three different investigations are in much better agreement with the calculations using the NCRP Report 58 and NNDC(2000) initial spectra with average discrepancies of 0.9% and 1.7% for the {sup 125}I and {sup 103}Pd seeds, respectively. However, there are no differences in the calculated TG-43U1 brachytherapy parameters using either initial spectrum in both cases. Similarly, there were no differences outside the statistical uncertainties of 0.1% or 0.2%, in the average energy, air kerma/history, dose rate/history, and dose rate constant when calculated using either the full photon spectrum or the main-peaks-only spectrum. Conclusions: Our calculated dose rate constants based on using the calculated on-axis spectrum and a line or dual-point source model are in excellent agreement (0.5% on average) with the values of Chen and Nath, verifying the accuracy of their more approximate method of going from the spectrum to the dose rate constant. However, the dose rate constants based on full seed models differ by between +4.6% and -1.5% from those based on the line or dual-point source approximations. These results suggest that the main value of spectroscopic measurements is to verify full Monte Carlo models of the seeds by comparison to the calculated spectra.

60 APPLIED LIFE SCIENCES↗

Radiation Crosslinking of Modifying Super Absorbent (Polyacrylamide/Gelatin) Hydrogel as Fertilizers Carrier and Soil Conditioner

A novel approach is developed for preparing a highly porous super absorbent hydrogel (SAH). Synthetic and natural hydrogel based acrylamide (Am) and gelatin (G) were polymerized and crosslinked by gamma radiation. Three hydrogels compositions have been prepared in weight ratio 1:2, 1.5:1.5 and 2:1 (wt:wt) for 30% PAAM/G and exposed to gamma radiation at dose of 30 kGy. The effect of chemical modifications on increasing the swelling power of polyacrylamide gelatin (PAAM/G) has been evaluated. The alkaline hydrolysis of PAAM/G hydrogel with concentrated NaOH converts amid groups CONH{sub 2} to carboxylic groups COONa. The modified hydrogels will take the codes PAAM-COOH/G, PAAM-COONa/G and PAAM-COOK/G that dramatically increased the degree of swelling from 220 to 720 (g/g). Furthermore, studies on the slow release ability of three kinds of fertilizer (K, P and urea) loaded on modified PAAM-COOH/G and evaluated the ability of SAH hydrogels to absorb and then gradually release water and fertilizer. A mathematical model for fertilizer release from PAAM-COOK/G was applied to calculate the diffusion coefficient D. The main aim of this article is performed the effect of soil amendment with PAAM-COOK/G on eliminating water stress was tested for bean plant (Vicia faba) irrigation cycles in drought-prone environments. The growth of bean plant was monitored by measuring the highest and size of leaves and bean seed. The effect of water stress was monitored also, by measuring the intensity of chlorophyll for both SAH and control soil. The results indicated that the chemical modification of (PAAM/G) into (PAAM-COOK/G) could greatly improve water absorbency. The experimental data indicated that the SAH has a positive effect to use as fertilizers carrier and soil conditioner.

36 MATERIALS SCIENCE↗

SU-F-T-660: Evaluating the Benefit of Using Dual-Function Fiducial Markers for In-Situ Delivery of Radiosenistizing Gold Nanoparticles During Image-Guided Radiotherapy

Purpose: Dual-function fiducials loaded with radiosensitizers, like gold nanoparticles (GNP), offer an innovative approach for ensuring geometric accuracy during image-guided radiotherapy (IGRT) and significantly increasing therapeutic efficacy due to controlled in-situ release of the radiosensitizers. This study retrospectively investigates the dosimetric benefit of using up to two such dual-function fiducial markers instead of traditional single function fiducials during IGRT. Methods: A computational code was developed to investigate the dosimetric benefit for 10 real patient tumor volumes of up to 6.5 cm diameter. The intra-tumoral space-time biodistribution of the GNP was modeled as in previous studies based on Fick’s second law. The corresponding dose-enhancement for each tumor voxel due to the GNP was also calculated for clinical 6MV beam configurations. Various loading concentrations (25–50 mg/g) were studied, as a function of GNP size, to determine potential for clinically significant dose enhancement. The time between initial implantation of dual-function fiducials to the beginning of radiotherapy was assumed to be 14 days as typical for many clinics. Results: A single dual-function fiducial could achieve at least a DEF of 1.2 for patients with tumors less than 1.4 cm diameter after 14 days. Replacing two single function fiducials with dual-function ones at the same locations achieved at least the required minimal DEF for tumors that are 2 cm diameter in 3 patients. The results also revealed dosimetrically better fiducial locations which could enable significant DEF when using one or two dual function fiducials. 2 nm sizes showed the most feasibility. Conclusion: The results highlight the potential of tumor sub-volume radiation boosting using GNP released from fiducials, and the ability to customize the DEF throughout the tumor by using two dual-function fiducials, varying the initial concentration and nanoparticle size. The results demonstrate potential for employing dual-function fiducials in the development of GNP-aided radiotherapy.

60 APPLIED LIFE SCIENCES↗

Criticality Accident Alarm System Shielding Benchmark: Integral Experiment Request 498, Critical Engineering Decision 1 Report

This report supports Critical/Subcritical Experiment Decision 1 (CED-1) for Integral Experiment Request (IER) 498, a shielding benchmark produced using the Godiva IV critical assembly at the National Critical Experiments Research Center (NCERC). Shielding benchmarks are datasets collected to provide a comparison for computer models that simulate the effect of shielding on radiation transmission from a source to a detector. The purpose of a CED-1 report is to produce a conceptual design for an integral experiment and to identify the long lead-time items. The design presented in this report favors certain detailed design options such as material selections. However, alternative options can be selected as the project evolves. Dimensions are specified only as needed to evaluate feasibility and performance. Development of Criticality Accident Alarm System (CAAS) shielding benchmarks supports two main programmatic needs. The first need is to improve confidence in models of facilities that house nuclear material handling operations. Better models can support effective CAAS detector placement when criticality may result in dose, and it enables more accurate analysis of criticality accident impacts at various locations in a facility. A key quantity that can be verified is the secondary gamma production caused by neutron interactions with various materials. The second programmatic need supported by shielding benchmarks is the ongoing development of methods being integrated into nuclear simulation codes such as the Monte Carlo N-Particle (MCNP) transport code and the SCALE code system used in efforts funded by the Nuclear Criticality Safety Program (NCSP). Previous work performed under the International Criticality Safety Benchmark Experimental Program (ICSBEP) to produce shielding benchmark data is primarily limited to a set of measurements at the SILENE critical assembly at the Valduc facility in France. The experiment used an open configuration and a burst mode operation, which limited detector options to thermoluminescent dosimeters (TLDs) and activation foils. Because TLDs do not record gamma spectra, it was difficult to verify the gamma energy spectrum from the experiment. In this work, the Godiva IV assembly will be used because it is a fast system capable of producing a wide range of source strengths, including super-prompt critical bursts. The room return for the facility is expected to be substantial and challenging to characterize, so a more closed, shielded experimental configuration is considered. Furthermore, because the physics of radiation transport outside the assembly does not change between the burst mode and the delayed critical mode, it is anticipated that most measurements will be made with the Godiva IV assembly in delayed critical mode, operating within a range that will allow electronic counters to collect accurate data. Scoping calculations concluded that a workable room return shield is comprised of 40 cm of 5% borated polyethylene backed by 7 cm of lead. This configuration was shown to produce a ratio of signal–to–room return of over 100 for up to 2 mean free paths of shield sample material, and over 10 for up to 4 mean free paths of shield sample material, ensuring that useful results can be obtained. With no shielding sample in the room return shield, it was shown that the neutron and gamma spectra do not appreciably change with a change in room size. This scoping calculation does not preclude the use of tungsten powder in a binder, some other effective gamma shielding material, or a hybrid design. Dose rates for various source intensities at an unshielded detector are listed herein to inform detector selection during CED-2, and calibration chains are identified. Preliminary estimates of costs and schedules are outlined but remain to be verified. Values could double or triple as estimates become more accurate and are principally included here to demonstrate feasibility. Preliminary estimates indicate that the apparatus can be installed within a feasible schedule and budget. Two measurements per day are assumed. Producing a shielding benchmark at NCERC using the Godiva IV assembly has been shown to be feasible, with manageable uncertainties and risks. A clear, continuing need for shielding benchmark data remains present, and this report identifies and evaluates a method for creating integrated shielding benchmark datasets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study

Purpose: To determine detector-specific output correction factors,k{sub Q} {sub c{sub l{sub i{sub n}}}} {sub ,Q} {sub m{sub s{sub r}}} {sup f{sub {sup {sub c}{sub l}{sub i}{sub n}{sub {sup ,f{sub {sup {sub m}{sub s}{sub r}{sub ,}}}}}}}} in 6 MV small photon beams for air and liquid ionization chambers, silicon diodes, and diamond detectors from two manufacturers. Methods: Field output factors, defined according to the international formalism published byAlfonso et al. [Med. Phys. 35, 5179–5186 (2008)], relate the dosimetry of small photon beams to that of the machine-specific reference field; they include a correction to measured ratios of detector readings, conventionally used as output factors in broad beams. Output correction factors were calculated with the PENELOPE Monte Carlo (MC) system with a statistical uncertainty (type-A) of 0.15% or lower. The geometries of the detectors were coded using blueprints provided by the manufacturers, and phase-space files for field sizes between 0.5 × 0.5 cm{sup 2} and 10 × 10 cm{sup 2} from a Varian Clinac iX 6 MV linac used as sources. The output correction factors were determined scoring the absorbed dose within a detector and to a small water volume in the absence of the detector, both at a depth of 10 cm, for each small field and for the reference beam of 10 × 10 cm{sup 2}. Results: The Monte Carlo calculated output correction factors for the liquid ionization chamber and the diamond detector were within about ±1% of unity even for the smallest field sizes. Corrections were found to be significant for small air ionization chambers due to their cavity dimensions, as expected. The correction factors for silicon diodes varied with the detector type (shielded or unshielded), confirming the findings by other authors; different corrections for the detectors from the two manufacturers were obtained. The differences in the calculated factors for the various detectors were analyzed thoroughly and whenever possible the results were compared to published data, often calculated for different accelerators and using the EGSnrc MC system. The differences were used to estimate a type-B uncertainty for the correction factors. Together with the type-A uncertainty from the Monte Carlo calculations, an estimation of the combined standard uncertainty was made, assigned to the mean correction factors from various estimates. Conclusions: The present work provides a consistent and specific set of data for the output correction factors of a broad set of detectors in a Varian Clinac iX 6 MV accelerator and contributes to improving the understanding of the physics of small photon beams. The correction factors cannot in general be neglected for any detector and, as expected, their magnitude increases with decreasing field size. Due to the reduced number of clinical accelerator types currently available, it is suggested that detector output correction factors be given specifically for linac models and field sizes, rather than for a beam quality specifier that necessarily varies with the accelerator type and field size due to the different electron spot dimensions and photon collimation systems used by each accelerator model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗