Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

TU-H-CAMPUS-JeP1-04: Deformable Image Registration Performances in Pelvis Patients: Impact of CBCT Image Quality

Purpose: To investigate the accuracy and robustness, against image noise and artifacts (typical of CBCT images), of a commercial algorithm for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on real prostate patient images. Methods: The Anaconda DIR algorithm, implemented in RayStation was tested. Two specific Deformation Vector Fields (DVFs) were applied to the reference data set (CTref) using the ImSimQA software, obtaining two deformed CTs. For each dataset twenty-four different level of noise and/or capping artifacts were applied to simulate CBCT images. DIR was performed between CTref and each deformed CTs and CBCTs. In order to investigate the relationship between image quality parameters and the DIR results (expressed by a logit transform of the Dice Index) a bilinear regression was defined. Results: More than 550 DIR-mapped ROIs were analyzed. The Statistical analysis states that deformation strenght and artifacts were significant prognostic factors of DIR performances, while noise appeared to have a minor role in DIR process as implemented in RayStation as expected by the image similarity metric built in the registration algorithm. Capping artifacts reveals a determinant role for the accuracy of DIR results. Two optimal values for capping artifacts were found to obtain acceptable DIR results (DICE> 075/ 0.85). Various clinical CBCT acquisition protocol were reported to evaluate the significance of the study. Conclusion: This work illustrates the impact of image quality on DIR performance. Clinical issues like Adaptive Radiation Therapy (ART) and Dose Accumulation need accurate and robust DIR software. The RayStation DIR algorithm resulted robust against noise, but sensitive to image artifacts. This result highlights the need of robustness quality assurance against image noise and artifacts in the commissioning of a DIR commercial system and underlines the importance to adopt optimized protocols for CBCT image acquisitions in ART clinical implementation.

60 APPLIED LIFE SCIENCES↗

Nuclear Data Performance Testing Using Sensitive, but Less Frequently Used ICSBEP Benchmarks

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has published the International Handbook of Evaluated Criticality Safety Benchmark Experiments annually since 1995. The Handbook now spans over 51,000 pages with benchmark specifications for 4,283 critical, near critical, or subcritical configurations; 24 criticality alarm placement/shielding configurations with multiple dose points for each; and 200 configurations that have been categorized as fundamental physics measurements relevant to criticality safety applications. Benchmark data in the ICSBEP Handbook were originally intended for validation of criticality safety methods and data; however, the benchmark specifications are now used extensively for nuclear data testing. There are several, less frequently used benchmarks within the Handbook that are very sensitive to thorium and certain key structural and moderating materials. Calculated results for many of those benchmarks using modern nuclear data libraries suggest there is still room for improvement. These and other highly sensitive, but rarely quoted benchmarks are highlighted and data testing results provided using the Monte Carlo N-Particle Version 5 (MCNP5) code and continuous energy ENDF/B-V, VI.8, and VII.0, JEFF-3.1, and JENDL-3.3 nuclear data libraries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-T-376: The Efficiency of Calculating Photonuclear Reaction On High-Energy Photon Therapy by Monte Carlo Method

Purpose: Secondary-neutrons having harmful influences to a human body are generated by photonuclear reaction on high-energy photon therapy. Their characteristics are not known in detail since the calculation to evaluate them takes very long time. PHITS(Particle and Heavy Ion Transport code System) Monte Carlo code since versions 2.80 has the new parameter “pnimul” raising the probability of occurring photonuclear reaction forcibly to make the efficiency of calculation. We investigated the optimum value of “pnimul” on high-energy photon therapy. Methods: The geometry of accelerator head based on the specification of a Varian Clinac 21EX was used for PHITS ver. 2.80. The phantom (30 cm * 30 cm * 30 cm) filled the composition defined by ICRU(International Commission on Radiation Units) was placed at source-surface distance 100 cm. We calculated the neutron energy spectra in the surface of ICRU phantom with “pnimal” setting 1, 10, 100, 1000, 10000 and compared the total calculation time and the behavior of photon using PDD(Percentage Depth Dose) and OCR(Off-Center Ratio). Next, the cutoff energy of photon, electron and positron were investigated for the calculation efficiency with 4, 5, 6 and 7 MeV. Results: The calculation total time until the errors of neutron fluence become within 1% decreased as increasing “pnimul”. PDD and OCR showed no differences by the parameter. The calculation time setting the cutoff energy like 4, 5, 6 and 7 MeV decreased as increasing the cutoff energy. However, the errors of photon become within 1% did not decrease by the cutoff energy. Conclusion: The optimum values of “pnimul” and the cutoff energy were investigated on high-energy photon therapy. It is suggest that using the optimum “pnimul” makes the calculation efficiency. The study of the cutoff energy need more investigation.

60 APPLIED LIFE SCIENCES↗

Economic Model For GDP And Tangible-Assets Loss Estimation In The MACCS Offsite Consequence Analysis Code

The MELCOR Accident Consequence Code System (MACCS) code is the NRC code used to perform probabilistic health and economic consequence assessments for atmospheric releases of radionuclides. MACCS is used by U.S. nuclear power plant license renewal applicants to support the plant specific evaluation of severe accident mitigation alternatives (SAMA) analyses as part of an applicant's environmental report for license renewal. MACCS is also used in severe accident mitigation design alternatives (SAMDA) and severe accident consequence analyses for environmental impact statements (EISs) for new reactor applications. The NRC uses MACCS in its cost-benefit assessments supporting regulatory analyses that evaluate potential new regulatory requirements for nuclear power plants. NRC regulatory analysis guidelines recommend the use of MACCS to estimate the averted "offsite property damage" cost (benefit) and the averted offsite dose cost elements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors

Purpose: To assess intrafraction respiratory motion using a commercial kilovoltage imaging system for abdominal tumor patients with implanted fiducials and breathing constrained by pneumatic compression during stereotactic body radiation therapy (SBRT). Methods and Materials: A pneumatic compression belt limited respiratory motion in 19 patients with radiopaque fiducials in or near their tumor during SBRT for abdominal tumors. Kilovoltage images were acquired at 5- to 6-second intervals during treatment using a commercial system. Intrafractional fiducial displacements were measured using in-house software. The dosimetric effect of the observed displacements was calculated for 3 sessions for each patient. Results: Intrafraction displacement patterns varied between patients and between individual treatment sessions. Averaged over 19 patients, 73 sessions, 7.6% of craniocaudal displacements exceeded 0.5 cm, and 1.2% exceeded 0.75 cm. The calculated single-session dose to 95% of gross tumor volume differed from planned by an average of −1.2% (range, −11.1% to 4.8%) but only for 4 patients was the total 3-session calculated dose to 95% of gross tumor volume more than 3% different from planned. Conclusions: Our pneumatic compression limited intrafractional abdominal target motion, maintained target position established at setup, and was moderately effective in preserving coverage. Commercially available intrafractional imaging is useful for surveillance but can be made more effective and reliable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

SU-G-TeP1-15: Toward a Novel GPU Accelerated Deterministic Solution to the Linear Boltzmann Transport Equation

Purpose: To develop a Graphic Processor Unit (GPU) accelerated deterministic solution to the Linear Boltzmann Transport Equation (LBTE) for accurate dose calculations in radiotherapy (RT). A deterministic solution yields the potential for major speed improvements due to the sparse matrix-vector and vector-vector multiplications and would thus be of benefit to RT. Methods: In order to leverage the massively parallel architecture of GPUs, the first order LBTE was reformulated as a second order self-adjoint equation using the Least Squares Finite Element Method (LSFEM). This produces a symmetric positive-definite matrix which is efficiently solved using a parallelized conjugate gradient (CG) solver. The LSFEM formalism is applied in space, discrete ordinates is applied in angle, and the Multigroup method is applied in energy. The final linear system of equations produced is tightly coupled in space and angle. Our code written in CUDA-C was benchmarked on an Nvidia GeForce TITAN-X GPU against an Intel i7-6700K CPU. A spatial mesh of 30,950 tetrahedral elements was used with an S4 angular approximation. Results: To avoid repeating a full computationally intensive finite element matrix assembly at each Multigroup energy, a novel mapping algorithm was developed which minimized the operations required at each energy. Additionally, a parallelized memory mapping for the kronecker product between the sparse spatial and angular matrices, including Dirichlet boundary conditions, was created. Atomicity is preserved by graph-coloring overlapping nodes into separate kernel launches. The one-time mapping calculations for matrix assembly, kronecker product, and boundary condition application took 452±1ms on GPU. Matrix assembly for 16 energy groups took 556±3s on CPU, and 358±2ms on GPU using the mappings developed. The CG solver took 93±1s on CPU, and 468±2ms on GPU. Conclusion: Three computationally intensive subroutines in deterministically solving the LBTE have been formulated on GPU, resulting in two orders of magnitude speedup. Funding support from Natural Sciences and Engineering Research Council and Alberta Innovates Health Solutions. Dr. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

pysrim: Automation, Analysis, and Plotting of SRIM Calculations

The behavior of ions traveling through a material is of great interest to many fields. For instance, radiation damage in nuclear materials and ion beam modification of materials are most concerned with understanding the formation and evolution of defects along the ion path (Was 2016). Some of the important properties that can be gleaned from investigating the initial damage from the ion include: numbers of interstitials and vacancies produced, energy deposited per unit length to electrons and atomic nuclei, track diameter, and implanted ion profile. These properties enable further simulations and allow computing a common unit of radiation damage dose, displacements per atom (dpa), which can be used to compare irradiation experiments with different ions (Backman et al. 2013) (Stoller et al. 2013). Additionally, the ejection of materials near the surface due to incident ions is important to sputtering and ion-beam analysis techniques, such as elastic recoil detection analysis (ERDA) and secondary ion mass spectrometry (SIMS) (Vickerman and Gilmore 2011). The interaction of ions within a material can be broken into two parts: electronic and nuclear stopping. Electronic stopping is the energy lost from the ion due to inelastic collisions with electrons along its path. Nuclear stopping is the energy lost due to elastic collisions between the ion and atomic nuclei within the material. The Stopping and Range of Ions in Matter (SRIM) code is a well known software in the radiation damage and ion-beam communities that allows the simulation, via Monte Carlo, of ions through a material by modeling the energy transfer through electronic and nuclear stopping (J. F. Ziegler, Ziegler, and Biersack 2010). SRIM was originally developed in 1985 and has had numerous updates on the electronic stopping powers since then, with the nuclear stopping well explained by the ZBL potential (J. F. Ziegler 1988). The executable SRIM is free to use for non-commercial use but the source code is not available to the community despite requests. While SRIM is a scientifically accurate code it does not get updated frequently and has many bugs from a usability standpoint.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo simulation of a compact microbeam radiotherapy system based on carbon nanotube field emission technology

Purpose: Microbeam radiation therapy (MRT) is an experimental radiotherapy technique that has shown potent antitumor effects with minimal damage to normal tissue in animal studies. This unique form of radiation is currently only produced in a few large synchrotron accelerator research facilities in the world. To promote widespread translational research on this promising treatment technology we have proposed and are in the initial development stages of a compact MRT system that is based on carbon nanotube field emission x-ray technology. We report on a Monte Carlo based feasibility study of the compact MRT system design. Methods: Monte Carlo calculations were performed using EGSnrc-based codes. The proposed small animal research MRT device design includes carbon nanotube cathodes shaped to match the corresponding MRT collimator apertures, a common reflection anode with filter, and a MRT collimator. Each collimator aperture is sized to deliver a beam width ranging from 30 to 200 {mu}m at 18.6 cm source-to-axis distance. Design parameters studied with Monte Carlo include electron energy, cathode design, anode angle, filtration, and collimator design. Calculations were performed for single and multibeam configurations. Results: Increasing the energy from 100 kVp to 160 kVp increased the photon fluence through the collimator by a factor of 1.7. Both energies produced a largely uniform fluence along the long dimension of the microbeam, with 5% decreases in intensity near the edges. The isocentric dose rate for 160 kVp was calculated to be 700 Gy/min/A in the center of a 3 cm diameter target. Scatter contributions resulting from collimator size were found to produce only small (<7%) changes in the dose rate for field widths greater than 50 {mu}m. Dose vs depth was weakly dependent on filtration material. The peak-to-valley ratio varied from 10 to 100 as the separation between adjacent microbeams varies from 150 to 1000 {mu}m. Conclusions: Monte Carlo simulations demonstrate that the proposed compact MRT system design is capable of delivering a sufficient dose rate and peak-to-valley ratio for small animal MRT studies.

60 APPLIED LIFE SCIENCES↗

Conditioned place preference and locomotor activity in response to methylphenidate, amphetamine and cocaine in mice lacking dopamine D4 receptors

Methylphenidate (MP) and amphetamine (AMPH) are the most frequently prescribed medications for the treatment of attention-deficit/hyperactivity disorder (ADHD). Both drugs are believed to derive their therapeutic benefit by virtue of their dopamine (DA)-enhancing effects, yet an explanation for the observation that some patients with ADHD respond well to one medication but not to the other remains elusive. The dopaminergic effects of MP and AMPH are also thought to underlie their reinforcing properties and ultimately their abuse. Polymorphisms in the human gene that codes for the DA D4 receptor (D4R) have been repeatedly associated with ADHD and may correlate with the therapeutic as well as the reinforcing effects of responses to these psychostimulant medications. Conditioned place preference (CPP) for MP, AMPH and cocaine were evaluated in wild-type (WT) mice and their genetically engineered littermates, congenic on the C57Bl/6J background, that completely lack D4Rs (knockout or KO). In addition, the locomotor activity in these mice during the conditioning phase of CPP was tested in the CPP chambers. D4 receptor KO and WT mice showed CPP and increased locomotor activity in response to each of the three psychostimulants tested. D4R differentially modulates the CPP responses to MP, AMPH and cocaine. While the D4R genotype affected CPP responses to MP (high dose only) and AMPH (low dose only) it had no effects on cocaine. Inasmuch as CPP is considered an indicator of sensitivity to reinforcing responses to drugs these data suggest a significant but limited role of D4Rs in modulating conditioning responses to MP and AMPH. In the locomotor test, D4 receptor KO mice displayed attenuated increases in AMPH-induced locomotor activity whereas responses to cocaine and MP did not differ. These results suggest distinct mechanisms for D4 receptor modulation of the reinforcing (perhaps via attenuating dopaminergic signalling) and locomotor properties of these stimulant drugs. Thus, individuals with D4 receptor polymorphisms might show enhanced reinforcing responses to MP and AMPH and attenuated locomotor response to AMPH.

59 BASIC BIOLOGICAL SCIENCES↗

RH-TRU Waste Content Codes (RH-TRUCON)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ab initio structure determination of nanocrystals of organic pharmaceutical compounds by electron diffraction at room temperature using a Timepix quantum area direct electron detector

A specialized quantum area detector for electron diffraction studies makes it possible to solve the structure of small organic compound nanocrystals in non-cryo conditions by direct methods. Until recently, structure determination by transmission electron microscopy of beam-sensitive three-dimensional nanocrystals required electron diffraction tomography data collection at liquid-nitrogen temperature, in order to reduce radiation damage. Here it is shown that the novel Timepix detector combines a high dynamic range with a very high signal-to-noise ratio and single-electron sensitivity, enabling ab initio phasing of beam-sensitive organic compounds. Low-dose electron diffraction data (∼0.013 e{sup −} Å{sup −2} s{sup −1}) were collected at room temperature with the rotation method. It was ascertained that the data were of sufficient quality for structure solution using direct methods using software developed for X-ray crystallography (XDS, SHELX) and for electron crystallography (ADT3D/PETS, SIR2014)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Summary Report for the NEPA Impact Analysis. Revision 1

The Waste Isolation Pilot Plant (WIPP), located in southeastern New Mexico, has been developed by the U.S. Department of Energy (DOE) for the geologic (deep underground) disposal of defense-related transuranic (TRU) waste. Containment of TRU waste at the WIPP facility is derived from standards set forth in Title 40 of the Code of Federal Regulations (CFR), Part 191. The DOE assesses compliance with the containment standards according to the Certification Criteria in Title 40 CFR Part 194 by means of Performance Assessment (PA) calculations performed by Sandia National Laboratories (SNL). WIPP PA calculations estimate the probability of radionuclide releases from the repository to the accessible environment for a regulatory period of 10,000 years after facility closure. The DOE Carlsbad Field Office (CBFO) has initiated a National Environmental Policy Act (NEPA) action for a proposal to excavate and use additional transuranic (TRU) waste disposal panels at the WIPP facility. This report documents an analysis undertaken as part of an effort to evaluate the potential environmental consequences of the proposed action. Although not explicitly required for a NEPA analysis, evaluations of a dose indicator to hypothetical members of the public after final facility closure are presented in this report. The analysis is carried out in two stages: first, Performance Assessment (PA) calculations quantify the potential releases to the accessible environment over a 10,000-year post-closure period. Second, dose was evaluated for three hypothetical exposure pathways using the conservative radionuclide concentrations assumed to be released to the accessible environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Microreactor Safety Analysis Challenges and Recommendations for Utilization of the Comprehensive Reactor Analysis Bundle

To enable the broad deployment of microreactors in fundamentally new application regimes (i.e., mobile and autonomous operations), their safety must be indisputable in terms of possessing inherent resistance to severe offsite dose consequences. Therefore, mechanistic beyond-design-basis event source term calculations that demonstrate a sufficiently large margin of safety will be required to accommodate these new application regimes, which have no history of commercial regulation. Even for traditional reactor operation configurations, safety analysis expertise and familiarity with accident phenomena and conditions in microreactors—specifically those with heat pipe primary cooling arrangements—are lacking compared with other advanced reactor concepts and small modular reactors. Recently, modeling and simulation tools to account for unique heat pipe design aspects have been developed by Sandia National Laboratories with MELCOR and by the US Department of Energy’s (DOE’s) Office of Nuclear Energy Advanced Modeling and Simulation Program with BlueCRAB. However, further demonstration and assessment of potential knowledge gaps are needed to support these codes’ broad usage by the microreactor community. Through the DOE Microreactor Program, an initial assessment of these two tools and guidance on how an evaluation model could be constructed was performed and is reported herein. Moreover, a proposed approach for demonstrating an evaluation model using these two tools is outlined.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Genetic Background Modulates lncRNA-Coordinated Tissue Response to Low Dose Ionizing Radiation

Long noncoding RNAs (lncRNAs) are emerging as key regulators of diverse cell functions and processes. However, the relevance of lncRNAs in the cell and tissue response to ionizing radiation has not yet been characterized. Here we used microarray profiling to determine lncRNA and mRNA expression in mammary glands of BALB/c and SPRET/EiJ mice after low-dose ionizing radiation (LDIR) exposure. We found that unirradiated mammary tissues of these strains differed significantly in baseline expressions of 290 lncRNAs. LDIR exposure (10 cGy) induced a significant change in the expression of many lncRNAs. The vast majority of lncRNAs identified to be differentially expressed after LDIR in either BALB/c or SPRET/EiJ had a significantly correlated expression pattern with at least one LDIR responsive mRNA. Functional analysis revealed that the response to LDIR in BALB/c mice is highly dynamic with enrichment for genes involved in tissue injury, inflammatory responses, and mammary gland development at 2, 4, and 8 weeks after LDIR, respectively. Our study demonstrates that genetic background strongly influences the expression of lncRNAs and their response to radiation and that lncRNAs may coordinate the tissue response to LDIR exposure via regulation of coding mRNAs.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Dynamic data-driven multiscale modeling for predicting the degradation of a 316L stainless steel nuclear cladding material

Here, we have developed a long short-term memory stacked ensemble (LSTM-SE) surrogate modeling approach that can provide rapid predictions of microstructural evolution and the resultant mechanical properties of American Iron and Steel Institute (AISI) 316L series stainless steel (316LSS) fuel cladding under conditions of varying temperature and radiation dose rate. To acquire training data, we developed and implemented a kinetic Monte Carlo (KMC) model to simulate precipitation kinetics of M 23 C 6 , γ', and G phases within SS316L cladding. Experimentally reported precipitation kinetics of SS316L in literature were linked to the kinetic parameters of the simulated precipitation in our KMC model. The model was then used to simulate microstructure evolution under synthetically generated treatments of varying temperature and radiation dose rate, for periods of up to 3000 hours. Changes in volume fraction, number density, and particle size of precipitates were recorded, and particle area fractions were correlated using statistical methods to develop the surrogate model. Simultaneously, the mechanical properties of the simulated microstructures were evaluated using microstructure-based finite element method (FEM) analysis to determine the elastic modulus, yield stress, ultimate tensile strength, and elongation to failure of the aged microstructures. Using this approach, our surrogate model can predict precipitation behavior within 0.25% volume fraction and mechanical properties within 6% relative error from the values predicted by the KMC and FEM models using 50 training simulations as input. The trained recurrent neural network-based model can return estimations of precipitation kinetics and mechanical properties ~1000 times faster than the physics-based codes. This work demonstrates, as a proof of concept, that reactor material service lifetimes under variable service conditions can be predicted for a statistics-based model from a practicably obtainable dataset.

36 MATERIALS SCIENCE↗

Post-Remediation Radiological Dose Assessment, Linde Site, Tonawanda, New York

A post-remediation radiological dose assessment was conducted for the Formerly Utilized Sites Remedial Action Program (FUSRAP) Linde Site by using the measured residual concentrations of the radionuclides of concern following the completion of the soils remedial action. The site’s FUSRAP-related contaminants of concern (COCs) are radionuclides associated with uranium processing activities conducted by the Manhattan Engineer District (MED) in support of the Nation’s early atomic energy and weapons program and include radium-226 (Ra-226), thorium-230 (Th-230), and total uranium (Utotal). Remedial actions to address Linde Site soils and structures were conducted in accordance with the Record of Decision for the Linde Site, Tonawanda, New York (ROD) (USACE 2000a). In the ROD, the U.S. Army Corps of Engineers (USACE) determined that the cleanup standards found in Title 40, Part 192 of the Code of Federal Regulations (40 CFR Part 192), the standards for cleanup of uranium mill sites designated under the Uranium Mill Tailings Radiation Control Act (UMTRCA), and the Nuclear Regulatory Commission (NRC) standards for decommissioning of licensed uranium and thorium mills, found in 10 CFR Part 40, Appendix A, Criterion 6(6), are Applicable or Relevant and Appropriate Requirements (ARARs) for cleanup of MED-related contamination at the Linde Site. The major elements of this remedy will involve excavation of the soils with COCs above soil cleanup levels and placement of clean materials to meet the other criteria of 40 CFR Part 192.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamic Data-Driven Multiscale Modeling for Predicting Microstructure and Mechanical Properties of 316L Stainless Steel

We have developed a long short-term memory stacked ensemble (LSTM-SE) surrogate modeling approach that can provide rapid predictions of microstructural evolution and the resultant mechanical properties of American Iron and Steel Institute (AISI) 316L series stainless steel (316LSS) fuel cladding under conditions of varying temperature and radiation dose rate. To acquire training data, we developed and implemented a kinetic Monte Carlo (KMC) model to simulate precipitation kinetics of M 23 C 6 , γ', and G phases within SS316L cladding. Experimentally reported precipitation kinetics of SS316L in literature were linked to the kinetic parameters of the simulated precipitation in our KMC model. The model was then used to simulate microstructure evolution under synthetically generated treatments of varying temperature and radiation dose rate, for periods of up to 3000 hours. Changes in volume fraction, number density, and particle size of precipitates were recorded, and particle area fractions were correlated using statistical methods to develop the surrogate model. Simultaneously, the mechanical properties of the simulated microstructures were evaluated using microstructure-based finite element method (FEM) analysis to determine the elastic modulus, yield stress, ultimate tensile strength, and elongation to failure of the aged microstructures. Using this approach, our surrogate model can predict precipitation behavior within 0.25% volume fraction and mechanical properties within 6% relative error from the values predicted by the KMC and FEM models using 50 training simulations as input. The trained recurrent neural network-based model can return estimations of precipitation kinetics and mechanical properties ~1000 times faster than the physics-based codes. This work demonstrates, as a proof of concept, that reactor material service lifetimes under variable service conditions can be predicted for a statistics-based model from a practicably obtainable dataset.

36 MATERIALS SCIENCE↗