Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Improved prescription for winding an electromagnet

We describe an improvement on the magnetic scalar potential approach to design an electromagnet, which incorporates the need to wind the coil as a helix. Any magnetic field that can be described by a magnetic scalar potential is produced with high fidelity within a Target region; all fields are confined within a larger Return. The helical winding only affects the field in the Return.

47 OTHER INSTRUMENTATION↗

Atom interferometry in space: Thermal management and magnetic shielding

Atom interferometry is an exciting tool to probe fundamental physics. It is considered especially apt to test the universality of free fall by using two different sorts of atoms. The increasing sensitivity required for this kind of experiment sets severe requirements on its environments, instrument control, and systematic effects. This can partially be mitigated by going to space as was proposed, for example, in the Spacetime Explorer and Quantum Equivalence Principle Space Test (STE-QUEST) mission. However, the requirements on the instrument are still very challenging. For example, the specifications of the STE-QUEST mission imply that the Feshbach coils of the atom interferometer are allowed to change their radius only by about 260 nm or 2.6 × 10{sup −4} % due to thermal expansion although they consume an average power of 22 W. Also Earth's magnetic field has to be suppressed by a factor of 10{sup 5}. We show in this article that with the right design such thermal and magnetic requirements can indeed be met and that these are not an impediment for the exciting physics possible with atom interferometers in space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum B{sub min}-field in single frequency heating mode is often ≤0.8B{sub ECR}, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact LaBr{sub 3}: Ce Gamma Ray Detector with Si-APD Readout

BrilLanCe 380 (LaBr{sub 3}:Ce) crystal scintillators available from Saint-Gobain Crystals have achieved 2.6% FWHM for 662 keV photons. This is accomplished with PMT light sensors. Attempts to have similarly good results with PIN photo-diodes and APDs have not been successful. PIN photodiodes do not have any gain and the signal to noise ratio is poor at room temperature. Similarly, even though APDs have sufficient gain, they have poor signal to noise at room temperature. Recently there have been improvements in APDs decreasing the internal noise and increasing their sensitivity, making them an excellent light sensor. With the improved APD, it is now possible to achieve performance with a solid state light sensor comparable to that of PMTs. We have measured 2.8% for 662 keV gamma rays at room temperature using an APD for a light sensor on a 20 mm long crystal of 1.6 cc volume. APDs have advantages of compactness, inherent ruggedness and minimal sensitivity to magnetic fields. Such a device is very practical for hand held and portable field measurement applications. (Performance reported in SGC literature.)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking Electromagnetic Energy With SQUIDs

A superconducting quantum interference device (SQUID) is a gadget used to measure extremely weak signals, specifically magnetic flux. It can detect subtle changes in energy, up to 100 billion times weaker than the electromagnetic energy required to move a compass needle. SQUIDs are used for a variety of testing procedures where extreme sensitivity is required and where the test instrument need not come into direct contact with the test subject. NASA uses SQUIDs for remote, noncontact sensing in a variety of venues, including monitoring the Earth s magnetic field and tracking brain activity of pilots. Scientists at NASA s Goddard Space Flight Center have been making extensive use of this technology, from astrophysical research, to tracking the navigational paths of bees in flight to determine if they are using internal compasses. These very sensitive measurement devices have a wide variety of uses within NASA and even more uses within the commercial realm.

Source record↗

2D image of local density and magnetic fluctuations from line-integrated interferometry-polarimetry measurements

Combined polarimetry-interferometry capability permits simultaneous measurement of line-integrated density and Faraday effect with fast time response (∼1 μs) and high sensitivity. Faraday effect fluctuations with phase shift of order 0.05° associated with global tearing modes are resolved with an uncertainty ∼0.01°. For physics investigations, local density fluctuations are obtained by inverting the line-integrated interferometry data. The local magnetic and current density fluctuations are then reconstructed using a parameterized fit of the polarimetry data. Reconstructed 2D images of density and magnetic field fluctuations in a poloidal cross section exhibit significantly different spatial structure. Combined with their relative phase, the magnetic-fluctuation-induced particle transport flux and its spatial distribution are resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quartz-based flat-crystal resonant inelastic x-ray scattering spectrometer with sub-10 meV energy resolution

Continued improvement of the energy resolution of resonant inelastic x-ray scattering (RIXS) spectrometers is crucial for fulfilling the potential of this technique in the study of electron dynamics in materials of fundamental and technological importance. In particular, RIXS is the only alternative tool to inelastic neutron scattering capable of providing fully momentum resolved information on dynamic spin structures of magnetic materials, but is limited to systems whose magnetic excitation energy scales are comparable to the energy resolution. The state-of-the-art spherical diced crystal analyzer optics provides energy resolution as good as 25 meV but has already reached its theoretical limit. For this study, we demonstrate a novel sub-10 meV RIXS spectrometer based on flat-crystal optics at the Ir-L3 absorption edge (11.215 keV) that achieves an analyzer energy resolution of 3.9 meV, very close to the theoretical value of 3.7 meV. In addition, the new spectrometer allows efficient polarization analysis without loss of energy resolution. The performance of the instrument is emonstrated using longitudinal acoustical and optical phonons in diamond, and magnon in Sr 3 Ir 2 O 7 . The novel sub-10 meV RIXS spectrometer thus provides a window into magnetic materials with small energy scales.

36 MATERIALS SCIENCE↗

Multi-collector Isotope Ratio Mass Spectrometer -- Operational Performance Report

This report describes the operational testing of a new magnetic sector mass spectrometer that utilizes seven full-sized discrete dynode electron multipliers operating simultaneously. The instrument includes a newly developed ion dispersion lens that enables the mass dispersed individual isotope beams to be separated sufficiently to allow a full-sized discrete dynode pulse counting multiplier to be used to measure each isotope beam. The performance of the instrument was measured using SRM 996 (244Pu spike) at loadings of 2.4 and 12 fg on resin beads and with SRM 4350B Columbia River Sediment samples. The measured limit of detection (3s) for 240Pu was 3.4 attograms for SRM 996. The limit of quantitation (LOQ), defined as 10 s, was 11.2 attograms. The measured concentration of 239Pu in the CRS standard was 152 ± 6 fg/g.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SXR-XUV Diagnostics for Edge and Core of Magnetically Confined Plasmas

The present report summarizes the results obtained during a one-year extension of DoE grant “SXR-XUV Diagnostics for Edge and Core of Magnetically Confined Plasmas”, at Johns Hopkins University, aimed at completing the development of a new type of magnetic fusion plasma diagnostic, the XUV Transmission Grating Imaging Radiometer (TGIR). The TGIR enables simultaneous spatially and spectrally resolved measurements of the XUV/VUV radiated power from impurities in fusion plasmas, with high speed. The instrument was successfully developed and qualified in the laboratory and in experiments on a tokamak. Its future applications will be diagnostic of the impurity content and transport in the divertor and edge of advanced magnetic fusion experiments, such as NSTX Upgrade.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The vector magnetograph of the Sayan Solar Observatory

The problem of choosing an optimum scheme for the electrooptical analyzer of polarization and related control principles are discussed. An electrooptical deflector, which is advantageously used to employ a single photodetector and to remove systematic errors inherent in magnetographs with two photodetectors in the wings of the line is discussed, as well as adjustment errors of optical elements of the polarization analyzer and errors of control voltages. A method for measuring the telescope's polarization matrix, reduction of magnetographic measurements for instrumental polarization and calibration of magnetograph channels are examined. Questions of evaluating scattered light and of reducing magnetic field measurements are also considered as a computational procedure for the magnetic field vector parameters is briefly outlined. Computer control of the solar magnetograph and of the processing and control system software is discussed.

Grigoryev, V. M.↗

Three-Axis Superconducting Gravity Gradiometer

Gravity gradients measured even on accelerating platforms. Three-axis superconducting gravity gradiometer based on flux quantization and Meissner effect in superconductors and employs superconducting quantum interference device as amplifier. Incorporates several magnetically levitated proof masses. Gradiometer design integrates accelerometers for operation in differential mode. Principal use in commercial instruments for measurement of Earth-gravity gradients in geo-physical surveying and exploration for oil.

Paik, Ho Jung↗

Ring current development during the great geomagnetic storm of February 1986

The variations of the ring current energy density and composition during the great magnetic storm of February 1986 were investigated using particle measurements obtained by the charge-energy-mass instrument on the AMPTE Charge Composition Explorer spacecraft. The ring current composition of this storm, which had a complicated main phase and a minimum Dst of -312 nT on February 9, was followed for five days from the prestorm quiet time to the early recovery phase. Results suggested that the very rapid initial Dst recovery (tau of about 9.3 hrs) in this storm resulted largely from the rapid loss of 75- to 100-keV O(+) via charge exchange in the inner portion of the ring current. It is proposed that a major O(+) + N(+) ring current component generally exists near the maximum phase of great storms.

Hamilton, D. C.↗

Toroidal standing waves excited by a storm sudden commencement - DE 1 observations

A 74-nT sudden commencement on July 13, 1982, was observed in the magnetosphere, with instruments on the Dynamics Explorer 1 satellite. Inbound, near L = 4.5, the satellite was located at 1524 magnetic local time and 20 deg magnetic latitude. The sudden commmencement established a strong, east-west oscillation, with 100-s period, which was observed in the magnetic field, the electric field, and the plasma flow velocity records. There was also a compressional component of this 100-s oscillation and a rapidly damped 300-s compressional pulsation. The compressional oscillations may be an evidence of cavity resonances, excited by the sudden commencement. The cavity waves may, in turn, couple to toroidal waves in field line resonance at the satellite location. In addition, the sudden commencement caused the onset of waves with frequencies from 0.1 up to at least 0.5 Hz. The observations are compared with similar reports from earlier pulsations related to sudden commencements.

Cahill, L. J., Jr.↗

High-speed pitch angle sorter

A high-speed method was developed to compress the two-dimensional angular distribution of space particles gathered by space plasma instrumentation into the angle distribution, where the pitch angle is polar angle with respect to the ambient magnetic field. The pitch angle sorter can handle rates of up to 2 MHz and it is designed to accommodate high angular resolution plasma analyzers that are placed on a rotating spacecraft. This compression is achieved by relying on digitally encoded lookup tables to eliminate all arithmetic operations while applying the high symmetry of this compression to reduce the amount of digital memory.

Keller, John W.↗

Thermal mechanical analysis of sprag clutches

Work done at Case Western Reserve University on the Thermal Mechanical analysis of sprag helicopter clutches is reported. The report is presented in two parts. The first part is a description of a test rig for the measurement of the heat generated by high speed sprag clutch assemblies during cyclic torsional loading. The second part describes a finite element modeling procedure for sliding contact. The test rig provides a cyclic torsional load of 756 inch-pounds at 5000 rpm using a four-square arrangement. The sprag clutch test unit was placed between the high speed pinions of the circulating power loop. The test unit was designed to have replaceable inner ad outer races, which contain the instrumentation to monitor the sprag clutch. The torque loading device was chosen to be a water cooled magnetic clutch, which is controlled either manually or through a computer. In the second part, a Generalized Eulerian-Lagrangian formulation for non-linear dynamic problems is developed for solid materials. This formulation is derived from the basic laws and axioms of continuum mechanics. The novel aspect of this method is that we are able to investigate the physics in the spatial region of interest as material flows through it without having to follow material points. A finite element approximation to the governing equations is developed. Iterative Methods for the solution of the discrete finite element equations are explored. A FORTRAN program to implement this formulation is developed and a number of solutions to problems of sliding contact are presented.

Mullen, Robert L.↗

High temperature superconductors for magnetic suspension applications

High temperature superconductors (HTS) hold the promise for applications in magnetic levitation bearings, vibration damping, and torque coupling. Traditional magnetic suspension systems require active feedback and vibration controls in which power consumption and low frequency vibration are among the major engineering concerns. HTS materials have been demonstrated to be an enabling approach towards such problems due to their flux trapping properties. In our laboratory at TCSUH, we have been conducting a series of experiments to explore various mechanical applications using HTS. We have constructed a 30 lb. model flywheel levitated by a hybrid superconducting magnetic bearing (HSMB). We are also developing a levitated and vibration-dampled platform for high precision instrumentation. These applications would be ideal for space usages where ambient temperature is adequate for HTS to operate properly under greatly reduced cryogenic requirements. We will give a general overview of these potential applications and discuss the operating principles of the HTS devices we have developed.

Mcmichael, C. K.↗

Demonstration of high sensitivity laser ranging system

We report on a high sensitivity semiconductor laser ranging system developed for the Gravity and Magnetic Earth Surveyor (GAMES) for measuring variations in the planet's gravity field. The GAMES laser ranging instrument (LRI) consists of a pair of co-orbiting satellites, one which contains the laser transmitter and receiver and one with a passive retro-reflector mounted in an drag-stabilized housing. The LRI will range up to 200 km in space to the retro-reflector satellite. As the spacecraft pair pass over the spatial variations in the gravity field, they experience along-track accelerations which change their relative velocity. These time displaced velocity changes are sensed by the LRI with a resolution of 20-50 microns/sec. In addition, the pair may at any given time be drifting together or apart at a rate of up to 1 m/sec, introducing a Doppler shift into the ranging signals. An AlGaAs laser transmitter intensity modulated at 2 GHz and 10 MHz is used as fine and medium ranging channels. Range is measured by comparing phase difference between the transmit and received signals at each frequency. A separate laser modulated with a digital code, not reported in this paper, will be used for coarse ranging to unambiguously determine the distance up to 200 km.

Millar, Pamela S.↗

Book Review: Physics of the Space Environment

Space physics, narrowly defined as the study of Earth's plasma environment, has had an identity crisis throughout its relatively brief existence as a discipline. - The limited and often serendipitous nature of the data requires the research style of an astrophysicist. However, the in situ observations and instrumentation that are central to the field are quite different from the remote observations and instrumentation of astronomy. Compared to neutral gases, the wealth of additional phenomena and the complexity associated with magnetized plasmas and their interaction leaves little in common with the atmospheric scientist. Although the phenomena studied in space physics are ultimately important to astrophysics, the intimate measurements of plasma properties provide a greater commonality with the plasma physicist. Space physics has experienced something of a renaissance in the past few years. The interdisciplinary umbrella "Solar-Terrestrial Physics" or "Sun-Earth Connection" has stimulated an increasing interaction of space physicists, solar physicists and atmospheric scientists. Spectacular images of the Sun from Yohkoh and SOHO and solar-activity-related damage to communications satellites have increased the public's awareness of and interest in "space weather". The dangers of energetic particles and currents in space to technological systems and to future space exploration have elevated space physics observations from interesting scientific measurements that can be included on a space probe to critically important measurements that must be made.

Holman, Gordon D.↗