Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

On the possibility to detect multipolar order in URu 2 Si 2 by the electric quadrupolar transition of resonant elastic x-ray scattering

Resonant elastic x-ray scattering is a powerful technique for measuring multipolar order parameters. In this paper, we theoretically and experimentally study the possibility of using this technique to detect the proposed multipolar order parameters in URu 2 Si 2 at the U- L 3 edge with the electric quadrupolar transition. Based on an atomic model, we calculate the azimuthal dependence of the quadrupolar transition at the U- L 3 edge. Our results illustrate the potential of this technique for distinguishing different multipolar order parameters. We then perform experiments on ultraclean single crystals of URu 2 Si 2 at the U- L 3 edge to search for the predicted signal, but do not detect any indications of multipolar moments within the experimental uncertainty. We also theoretically estimate the orders of magnitude of the cross section and the expected count rate of the quadrupolar transition and compare them to the dipolar transitions at the U- M 4 and U- L 3 edges, clarifying the difficulty in detecting higher order multipolar order parameters in URu 2 Si 2 in the current experimental setup.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Novel Measurement of the Anomalous Muon Spin Precession Frequency in the Muon $g-2$ Experiment at Fermilab

The Muon $g-2$ Experiment operated at Fermi National Accelerator Laboratory (FNAL, or Fermilab) between 2018 and 2023 to produce the world's most precise measurement of the muon's \textit{anomalous magnetic moment}, $a_\mu = \frac{g_\mu - 2}{2}$, which expresses the relative deviation in the muon's $g$-factor from a baseline theoretical expectation that $g_\mu = 2$. In the Standard Model of particle physics, $g_\mu > 2$ and hence $a_\mu > 0$ by a calculable amount that depends on all possible interactions between the muon and all other fundamental particles, including any potentially undiscovered interactions beyond the Standard Model. For this reason, measurements of the electron anomaly $a_e$ and later the muon anomaly $a_\mu$ have helped guide the development of the Standard Model since the inception of quantum field theory, and the measured value of $a_\mu$ provides a valuable constraint for new hypotheses that extend the Standard Model. As of 2006, the leading measurement and Standard Model prediction for $a_\mu$ exhibited tension at the level of about three standard deviations, motivating an improved measurement at Fermilab that could test the tension more precisely. The experiment functions by storing a polarized beam of $\mu^+$ in a uniform magnetic field, which simultaneously induces circular motion and spin precession. As the stored muons undergo the Michel decay $\mu^+ \to e^+ + \nu_e + \bar{\nu}_\mu$, mediated by the parity-violating weak interaction, the rest-frame $e^+$ emission direction is correlated with the parent $\mu^+$ spin orientation. Boosting into the laboratory frame encodes this correlation in the decay $e^+$ energy, which is higher when the emission (i.e. $\mu^+$ spin direction) is aligned with the $\mu^+$ momentum, and lower when opposite. Detectors then count the rate of high-energy decay $e^+$, which modulates at the difference between the $\mu^+$ revolution and spin precession frequencies. This observed frequency, called the \textit{anomalous spin precession frequency} $\omega_a$, is directly proportional to $a_\mu$. The extraction of $\omega_a$ proceeds by fitting the time spectrum of detected $e^+$, which requires precise modeling of the $\omega_a$ oscillation as well as any perturbations from beam dynamics and detector acceptance. Using the $\omega_a$ analysis presented in this work, based on Runs 4 -- 6 of the Muon $g-2$ Experiment at Fermilab, we find that $a_\mu = 0.001\,165\,920\,738(162)$ with a relative uncertainty of 139 parts per billion.

Barrett, Tyler [Cornell U.]↗

Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252 Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon-Counting Multikilohertz Microlaser Altimeters for Airborne and Spaceborne Topographic Measurements

We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.

Degnan, John J.↗

Visualization and modeling of inhibition of IL-1β and TNF-α mRNA transcription at the single-cell level

Abstract IL-1β and TNF-α are canonical immune response mediators that play key regulatory roles in a wide range of inflammatory responses to both chronic and acute conditions. Here we employ an automated microscopy platform for the analysis of messenger RNA (mRNA) expression of IL-1β and TNF-α at the single-cell level. The amount of IL-1β and TNF-α mRNA expressed in a human monocytic leukemia cell line (THP-1) is visualized and counted using single-molecule fluorescent in-situ hybridization (smFISH) following exposure of the cells to lipopolysaccharide (LPS), an outer-membrane component of Gram-negative bacteria. We show that the small molecule inhibitors MG132 (a 26S proteasome inhibitor used to block NF-κB signaling) and U0126 (a MAPK Kinase inhibitor used to block CCAAT-enhancer-binding proteins C/EBP) successfully block IL-1β and TNF-α mRNA expression. Based upon this single-cell mRNA expression data, we screened 36 different mathematical models of gene expression, and found two similar models that capture the effects by which the drugs U0126 and MG132 affect the rates at which the genes transition into highly activated states. When their parameters were informed by the action of each drug independently, both models were able to predict the effects of the combined drug treatment. From our data and models, we postulate that IL-1β is activated by both NF-κB and C/EBP, while TNF-α is predominantly activated by NF-κB. Our combined single-cell experimental and modeling efforts show the interconnection between these two genes and demonstrates how the single-cell responses, including the distribution shapes, mean expression, and kinetics of gene expression, change with inhibition.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron multiplicity ,easurements With 3 He alternative: Straw neutron detectors

Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10 B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions of neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3 He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10 B (in the form of enriched boron carbide: 10 B 4 C) for neutron detection instead of 3 He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mathematical efficiency calibration with uncertain source geometries using smart optimization

The In Situ Object Counting Software (ISOCS), a mathematical method developed by CANBERRA, is a well established technique for computing High Purity Germanium (HPGe) detector efficiencies for a wide variety of source shapes and sizes. In the ISOCS method, the user needs to input the geometry related parameters such as: the source dimensions, matrix composition and density, along with the source-to-detector distance. In many applications, the source dimensions, the matrix material and density may not be well known. Under such circumstances, the efficiencies may not be very accurate since the modeled source geometry may not be very representative of the measured geometry. CANBERRA developed an efficiency optimization software known as 'Advanced ISOCS' that varies the not well known parameters within user specified intervals and determines the optimal efficiency shape and magnitude based on available benchmarks in the measured spectra. The benchmarks could be results from isotopic codes such as MGAU, MGA, IGA, or FRAM, activities from multi-line nuclides, and multiple counts of the same item taken in different geometries (from the side, bottom, top etc). The efficiency optimization is carried out using either a random search based on standard probability distributions, or using numerical techniques that carry out a more directed (referred to as 'smart' in this paper) search. Measurements were carried out using representative source geometries and radionuclide distributions. The radionuclide activities were determined using the optimum efficiency and compared against the true activities. The 'Advanced ISOCS' method has many applications among which are: Safeguards, Decommissioning and Decontamination, Non-Destructive Assay systems and Nuclear reactor outages maintenance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FermI large area telescope third source catalog

We present the third Fermi Large Area Telescope (LAT) source catalog (3FGL) of sources in the 100 MeV–300 GeV range. Based on the first 4 yr of science data from the Fermi Gamma-ray Space Telescope mission, it is the deepest yet in this energy range. Relative to the Second Fermi LAT catalog, the 3FGL catalog incorporates twice as much data, as well as a number of analysis improvements, including improved calibrations at the event reconstruction level, an updated model for Galactic diffuse γ-ray emission, a refined procedure for source detection, and improved methods for associating LAT sources with potential counterparts at other wavelengths. The 3FGL catalog includes 3033 sources above 4σ significance, with source location regions, spectral properties, and monthly light curves for each. Of these, 78 are flagged as potentially being due to imperfections in the model for Galactic diffuse emission. Twenty-five sources are modeled explicitly as spatially extended, and overall 238 sources are considered as identified based on angular extent or correlated variability (periodic or otherwise) observed at other wavelengths. For 1010 sources we have not found plausible counterparts at other wavelengths. More than 1100 of the identified or associated sources are active galaxies of the blazar class; several other classes of non-blazar active galaxies are also represented in the 3FGL. Pulsars represent the largest Galactic source class. From source counts of Galactic sources we estimate that the contribution of unresolved sources to the Galactic diffuse emission is ∼3% at 1 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Overlapping qubits from non-isometric maps and de Sitter tensor networks

The emergence of a local effective theory from a more fundamental theory of quantum gravity with seemingly fewer degrees of freedom is a major puzzle of theoretical physics. A recent approach to this problem is to consider general features of the Hilbert space maps relating these theories. In this work, we construct approximately local observables, or overlapping qubits, from such non-isometric maps. We show that local processes in effective theories can be spoofed with a quantum system with fewer degrees of freedom, with deviations from actual locality identifiable as features of quantum gravity. For a concrete example, we construct two tensor network models of de Sitter space-time, demonstrating how exponential expansion and local physics can be spoofed for a long period before breaking down. Our results highlight the connection between overlapping qubits, Hilbert space dimension verification, degree-of-freedom counting in black holes, holography, and approximate locality in quantum gravity.

Quantum information↗

THE MAJOR AND MINOR GALAXY MERGER RATES AT z < 1.5

Calculating the galaxy merger rate requires both a census of galaxies identified as merger candidates and a cosmologically averaged 'observability' timescale (T{sub obs}(z)) for identifying galaxy mergers. While many have counted galaxy mergers using a variety of techniques, (T{sub obs}(z)) for these techniques have been poorly constrained. We address this problem by calibrating three merger rate estimators with a suite of hydrodynamic merger simulations and three galaxy formation models. We estimate (T{sub obs}(z)) for (1) close galaxy pairs with a range of projected separations, (2) the morphology indicator G - M{sub 20}, and (3) the morphology indicator asymmetry A. Then, we apply these timescales to the observed merger fractions at z < 1.5 from the recent literature. When our physically motivated timescales are adopted, the observed galaxy merger rates become largely consistent. The remaining differences between the galaxy merger rates are explained by the differences in the ranges of the mass ratio measured by different techniques and differing parent galaxy selection. The major merger rate per unit comoving volume for samples selected with constant number density evolves much more strongly with redshift ({proportional_to}(1 + z){sup +3.0{+-}1.1}) than samples selected with constant stellar mass or passively evolving luminosity ({proportional_to}(1 + z){sup +0.1{+-}0.4}). We calculate the minor merger rate (1:4 <M{sub sat}/M{sub primary} {approx}< 1:10) by subtracting the major merger rate from close pairs from the 'total' merger rate determined by G - M{sub 20}. The implied minor merger rate is {approx}3 times the major merger rate at z {approx} 0.7 and shows little evolution with redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

TESTING FOR A LARGE LOCAL VOID BY INVESTIGATING THE NEAR-INFRARED GALAXY LUMINOSITY FUNCTION

Recent cosmological modeling efforts have shown that a local underdensity on scales of a few hundred Mpc (out to z {approx} 0.1) could produce the apparent acceleration of the expansion of the universe observed via Type Ia supernovae. Several studies of galaxy counts in the near-infrared (NIR) have found that the local universe appears underdense by {approx}25%-50% compared with regions a few hundred Mpc distant. Galaxy counts at low redshifts sample primarily L {approx} L* galaxies. Thus, if the local universe is underdense, then the normalization of the NIR galaxy luminosity function (LF) at z > 0.1 should be higher than that measured for z < 0.1. Here we present a highly complete (>90%) spectroscopic sample of 1436 galaxies selected in the H band (1.6 {mu}m) to study the normalization of the NIR LF at 0.1 < z < 0.3 and address the question of whether or not we reside in a large local underdensity. Our survey sample consists of all galaxies brighter than 18th magnitude in the H band drawn from six widely separated fields at high Galactic latitudes, which cover a total of {approx}2 deg{sup 2} on the sky. We find that for the combination of our six fields, the product {phi}*L* at 0.1 < z < 0.3 is {approx}30% higher than that measured at lower redshifts. While our statistical errors in this measurement are on the {approx}10% level, we find the systematics due to cosmic variance may be larger still. We investigate the effects of cosmic variance on our measurement using the COSMOS cone mock catalogs from the Millennium Simulation and recent empirical estimates of cosmic variance. We find that our survey is subject to systematic uncertainties due to cosmic variance at the 15% level (1{sigma}), representing an improvement by a factor of {approx}2 over previous studies in this redshift range. We conclude that observations cannot yet rule out the possibility that the local universe is underdense at z < 0.1. The fields studied in this work have a large amount of publicly available ancillary data and we make available the images and catalogs used here.

79 ASTRONOMY AND ASTROPHYSICS↗

Active galactic nucleus black hole mass estimates in the era of time domain astronomy

We investigate the dependence of the normalization of the high-frequency part of the X-ray and optical power spectral densities (PSDs) on black hole mass for a sample of 39 active galactic nuclei (AGNs) with black hole masses estimated from reverberation mapping or dynamical modeling. We obtained new Swift observations of PG 1426+015, which has the largest estimated black hole mass of the AGNs in our sample. We develop a novel statistical method to estimate the PSD from a light curve of photon counts with arbitrary sampling, eliminating the need to bin a light curve to achieve Gaussian statistics, and we use this technique to estimate the X-ray variability parameters for the faint AGNs in our sample. We find that the normalization of the high-frequency X-ray PSD is inversely proportional to black hole mass. We discuss how to use this scaling relationship to obtain black hole mass estimates from the short timescale X-ray variability amplitude with precision ∼0.38 dex. The amplitude of optical variability on timescales of days is also anticorrelated with black hole mass, but with larger scatter. Instead, the optical variability amplitude exhibits the strongest anticorrelation with luminosity. We conclude with a discussion of the implications of our results for estimating black hole mass from the amplitude of AGN variability.

79 ASTRONOMY AND ASTROPHYSICS↗

COX-2/sEH Dual Inhibitor PTUPB Potentiates the Antitumor Efficacy of Cisplatin

Cisplatin-based therapy is highly toxic, but moderately effective in most cancers. Concurrent inhibition of cyclooxygenase-2 (COX-2) and soluble epoxide hydrolase (sEH) results in antitumor activity and has organ-protective effects. The goal of this paper was to determine the antitumor activity of PTUPB, an orally bioavailable COX-2/sEH dual inhibitor, in combination with cisplatin and gemcitabine (GC) therapy. NSG mice bearing bladder cancer patient-derived xenografts were treated with vehicle, PTUPB, cisplatin, GC, or combinations thereof. Mouse experiments were performed with two different PDX models. PTUPB potentiated cisplatin and GC therapy, resulting in significantly reduced tumor growth and prolonged survival. PTUPB plus cisplatin was no more toxic than cisplatin single-agent treatment as assessed by body weight, histochemical staining of major organs, blood counts, and chemistry. The combination of PTUPB and cisplatin increased apoptosis and decreased phosphorylation in the MAPK/ERK and PI3K/AKT/mTOR pathways compared with controls. PTUPB treatment did not alter platinum–DNA adduct levels, which is the most critical step in platinum-induced cell death. The in vitro study using the combination index method showed modest synergy between PTUPB and platinum agents only in 5637 cell line among several cell lines examined. However, PTUPB is very active in vivo by inhibiting angiogenesis. Finally, PTUPB potentiated the antitumor activity of cisplatin-based treatment without increasing toxicity in vivo and has potential for further development as a combination chemotherapy partner.

60 APPLIED LIFE SCIENCES↗

Development of an ideal observer that incorporates nuisance parameters and processes list-mode data

Observer models were developed to process data in list-mode format in order to perform binary discrimination tasks for use in an arms-control-treaty context. Data used in this study was generated using GEANT4 Monte Carlo simulations for photons using custom models of plutonium inspection objects and a radiation imaging system. We evaluated observer model performance and then presented using the area under the receiver operating characteristic curve. Lastly, we studied the ideal observer under both signal-known-exactly conditions and in the presence of unknowns such as object orientation and absolute count-rate variability; when these additional sources of randomness were present, their incorporation into the observer yielded superior performance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data Files for "The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure"

This dataset includes modeling results from The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure, including region-specific (i.e., national, state, and core-based statistical area [cities and towns]) electric vehicle supply equipment port count requirements in 2025 and 2030 for multiple scenarios described in the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation of MFiX-PIC

This work is aimed at verification and validation (V&V) of particle-in-cell (PIC) approach in the National Energy Technology Laboratory’s (NETL) Multiphase Flow with Interphase eXchanges (MFiX-PIC) which was officially released in April 2019. Under verification, the results from MFiX-PIC are compared with exact or analytical solutions, while experimental results are used for benchmarking under validation. The test suite consists of the following cases: Terminal velocity. Particle advection in time-varying flow field. Particle settling in a dense medium. Evaporation. Rayleigh-Taylor instability. Minimum fluidization. Mini-circulating fluidized bed. The cases reported in a format consistent with the existing Verification and Validation Manual (Musser et al., 2018) explore a wide range of flow velocities and concentration regimes. Only one case considered in this work verifies the implementation of heat and mass transfer routines in MFiX-PIC, while a few other studies are currently underway to further expand the validation space in reacting flows. This study highlights the need for a rigorous analysis to objectively quantify the effect of model parameters. In addition, there is a scarcity of high-quality experimental data in the literature suitable for validating PIC methodology. Future efforts would include performing experiments which provide results for a valuable database. While designing such experiments, particle count should be significant to have sufficient particles per parcel while maintaining an optimal parcel to cell volume ratio. Also, datasets should have objectively assessed experimental uncertainty whereby confidence interval in those measurements become more explicit.

42 ENGINEERING↗

Data Files for “The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure"

This data set includes modeling results from “The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure” including region-specific [i.e., national, state, and core-based statistical area (CBSA)—cities/towns] electric vehicle supply equipment (EVSE) port count requirements in 2025 and 2030 for multiple scenarios described in the study. Please cite as: Wood, E., B. Borlaug, M. Moniot, D.-Y. Lee, Y. Ge, F. Yang, and Z. Liu. 2023. The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-85654.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The use of a panel code on high lift configurations of a swept forward wing

A study was done on high lift configurations of a generic swept forward wing using a panel code prediction method. A survey was done of existing codes available at Ames, frow which the program VSAERO was chosen. The results of VSAERO were compared with data obtained from the Ames 7- by 10-foot wind tunnel. The results of the comparison in lift were good (within 3.5%). The comparison of the pressure coefficients was also good. The pitching moment coefficients obtained by VSAERO were not in good agreement with experiment. VSAERO's ability to predict drag is questionable and cannot be counted on for accurate trends. Further studies were done on the effects of a leading edge glove, canards, leading edge sweeps and various wing twists on spanwise loading and trim lift with encouraging results. An unsuccessful attempt was made to model spanwise blowing and boundary layer control on the trailing edge flap. The potential results of VSAERO were compared with experimental data of flap deflections with boundary layer control to check the first order effects.

Scheib, J. S.↗